Complete Parameter List

Full Parameter List of Copter latest V4.7.0 dev

You can change and check the parameters for another version:

This is a complete list of the parameters which can be set (e.g. via the MAVLink protocol) to control vehicle behaviour. They are stored in persistent storage on the vehicle.

This list is automatically generated from the latest ardupilot source code, and so may contain parameters which are not yet in the stable released versions of the code.

ArduCopter Parameters

FORMAT_VERSION: Eeprom format version number

Note: This parameter is for advanced users

This value is incremented when changes are made to the eeprom format

SYSID_MYGCS: My ground station number

Note: This parameter is for advanced users

Allows restricting radio overrides to only come from my ground station

Increment

Range

1

1 to 255

PILOT_THR_FILT: Throttle filter cutoff

Note: This parameter is for advanced users

Throttle filter cutoff (Hz) - active whenever altitude control is inactive - 0 to disable

Increment

Range

Units

.5

0 to 10

hertz

PILOT_TKOFF_ALT: Pilot takeoff altitude

Altitude that altitude control modes will climb to when a takeoff is triggered with the throttle stick.

Increment

Range

Units

10

0.0 to 1000.0

centimeters

PILOT_THR_BHV: Throttle stick behavior

Bitmask containing various throttle stick options. TX with sprung throttle can set PILOT_THR_BHV to "1" so motor feedback when landed starts from mid-stick instead of bottom of stick.

Bitmask

Bit

Meaning

0

Feedback from mid stick

1

High throttle cancels landing

2

Disarm on land detection

TELEM_DELAY: Telemetry startup delay

Note: This parameter is for advanced users

The amount of time (in seconds) to delay radio telemetry to prevent an Xbee bricking on power up

Increment

Range

Units

1

0 to 30

seconds

GCS_PID_MASK: GCS PID tuning mask

Note: This parameter is for advanced users

bitmask of PIDs to send MAVLink PID_TUNING messages for

Bitmask

Bit

Meaning

0

Roll

1

Pitch

2

Yaw

3

AccelZ

RTL_ALT: RTL Altitude

The minimum alt above home the vehicle will climb to before returning. If the vehicle is flying higher than this value it will return at its current altitude.

Increment

Range

Units

1

30 to 300000

centimeters

RTL_CONE_SLOPE: RTL cone slope

Defines a cone above home which determines maximum climb

Increment

Range

Values

.1

0.5 to 10.0

Value

Meaning

0

Disabled

1

Shallow

3

Steep

RTL_SPEED: RTL speed

Defines the speed in cm/s which the aircraft will attempt to maintain horizontally while flying home. If this is set to zero, WPNAV_SPEED will be used instead.

Increment

Range

Units

50

0 to 2000

centimeters per second

RTL_ALT_FINAL: RTL Final Altitude

This is the altitude the vehicle will move to as the final stage of Returning to Launch or after completing a mission. Set to zero to land.

Increment

Range

Units

1

0 to 1000

centimeters

RTL_CLIMB_MIN: RTL minimum climb

The vehicle will climb this many cm during the initial climb portion of the RTL

Increment

Range

Units

10

0 to 3000

centimeters

RTL_LOIT_TIME: RTL loiter time

Time (in milliseconds) to loiter above home before beginning final descent

Increment

Range

Units

1000

0 to 60000

milliseconds

RTL_ALT_TYPE: RTL mode altitude type

RTL altitude type. Set to 1 for Terrain following during RTL and then set WPNAV_RFND_USE=1 to use rangefinder or WPNAV_RFND_USE=0 to use Terrain database

Values

Value

Meaning

0

Relative to Home

1

Terrain

FS_GCS_ENABLE: Ground Station Failsafe Enable

Controls whether failsafe will be invoked (and what action to take) when connection with Ground station is lost for at least 5 seconds. See FS_OPTIONS param for additional actions, or for cases allowing Mission continuation, when GCS failsafe is enabled.

Values

Value

Meaning

0

Disabled/NoAction

1

RTL

2

RTL or Continue with Mission in Auto Mode (Removed in 4.0+-see FS_OPTIONS)

3

SmartRTL or RTL

4

SmartRTL or Land

5

Land

6

Auto DO_LAND_START or RTL

7

Brake or Land

GPS_HDOP_GOOD: GPS Hdop Good

Note: This parameter is for advanced users

GPS Hdop value at or below this value represent a good position. Used for pre-arm checks

Range

100 to 900

SUPER_SIMPLE: Super Simple Mode

Bitmask to enable Super Simple mode for some flight modes. Setting this to Disabled(0) will disable Super Simple Mode. The bitmask is for flight mode switch positions

Bitmask

Bit

Meaning

0

SwitchPos1

1

SwitchPos2

2

SwitchPos3

3

SwitchPos4

4

SwitchPos5

5

SwitchPos6

WP_YAW_BEHAVIOR: Yaw behaviour during missions

Determines how the autopilot controls the yaw during missions and RTL

Values

Value

Meaning

0

Never change yaw

1

Face next waypoint

2

Face next waypoint except RTL

3

Face along GPS course

LAND_SPEED: Land speed

The descent speed for the final stage of landing in cm/s

Increment

Range

Units

10

30 to 200

centimeters per second

LAND_SPEED_HIGH: Land speed high

The descent speed for the first stage of landing in cm/s. If this is zero then WPNAV_SPEED_DN is used

Increment

Range

Units

10

0 to 500

centimeters per second

PILOT_SPEED_UP: Pilot maximum vertical speed ascending

The maximum vertical ascending velocity the pilot may request in cm/s

Increment

Range

Units

10

50 to 500

centimeters per second

PILOT_ACCEL_Z: Pilot vertical acceleration

The vertical acceleration used when pilot is controlling the altitude

Increment

Range

Units

10

50 to 500

centimeters per square second

FS_THR_ENABLE: Throttle Failsafe Enable

The throttle failsafe allows you to configure a software failsafe activated by a setting on the throttle input channel

Values

Value

Meaning

0

Disabled

1

Enabled always RTL

2

Enabled Continue with Mission in Auto Mode (Removed in 4.0+)

3

Enabled always Land

4

Enabled always SmartRTL or RTL

5

Enabled always SmartRTL or Land

6

Enabled Auto DO_LAND_START or RTL

7

Enabled always Brake or Land

FS_THR_VALUE: Throttle Failsafe Value

The PWM level in microseconds on channel 3 below which throttle failsafe triggers

Increment

Range

Units

1

910 to 1100

PWM in microseconds

THR_DZ: Throttle deadzone

The deadzone above and below mid throttle in PWM microseconds. Used in AltHold, Loiter, PosHold flight modes

Increment

Range

Units

1

0 to 300

PWM in microseconds

FLTMODE1: Flight Mode 1

Flight mode when pwm of Flightmode channel(FLTMODE_CH) is <= 1230

Values

Value

Meaning

0

Stabilize

1

Acro

2

AltHold

3

Auto

4

Guided

5

Loiter

6

RTL

7

Circle

9

Land

11

Drift

13

Sport

14

Flip

15

AutoTune

16

PosHold

17

Brake

18

Throw

19

Avoid_ADSB

20

Guided_NoGPS

21

Smart_RTL

22

FlowHold

23

Follow

24

ZigZag

25

SystemID

26

Heli_Autorotate

27

Auto RTL

28

Turtle

FLTMODE2: Flight Mode 2

Flight mode when pwm of Flightmode channel(FLTMODE_CH) is >1230, <= 1360

Values

Value

Meaning

0

Stabilize

1

Acro

2

AltHold

3

Auto

4

Guided

5

Loiter

6

RTL

7

Circle

9

Land

11

Drift

13

Sport

14

Flip

15

AutoTune

16

PosHold

17

Brake

18

Throw

19

Avoid_ADSB

20

Guided_NoGPS

21

Smart_RTL

22

FlowHold

23

Follow

24

ZigZag

25

SystemID

26

Heli_Autorotate

27

Auto RTL

28

Turtle

FLTMODE3: Flight Mode 3

Flight mode when pwm of Flightmode channel(FLTMODE_CH) is >1360, <= 1490

Values

Value

Meaning

0

Stabilize

1

Acro

2

AltHold

3

Auto

4

Guided

5

Loiter

6

RTL

7

Circle

9

Land

11

Drift

13

Sport

14

Flip

15

AutoTune

16

PosHold

17

Brake

18

Throw

19

Avoid_ADSB

20

Guided_NoGPS

21

Smart_RTL

22

FlowHold

23

Follow

24

ZigZag

25

SystemID

26

Heli_Autorotate

27

Auto RTL

28

Turtle

FLTMODE4: Flight Mode 4

Flight mode when pwm of Flightmode channel(FLTMODE_CH) is >1490, <= 1620

Values

Value

Meaning

0

Stabilize

1

Acro

2

AltHold

3

Auto

4

Guided

5

Loiter

6

RTL

7

Circle

9

Land

11

Drift

13

Sport

14

Flip

15

AutoTune

16

PosHold

17

Brake

18

Throw

19

Avoid_ADSB

20

Guided_NoGPS

21

Smart_RTL

22

FlowHold

23

Follow

24

ZigZag

25

SystemID

26

Heli_Autorotate

27

Auto RTL

28

Turtle

FLTMODE5: Flight Mode 5

Flight mode when pwm of Flightmode channel(FLTMODE_CH) is >1620, <= 1749

Values

Value

Meaning

0

Stabilize

1

Acro

2

AltHold

3

Auto

4

Guided

5

Loiter

6

RTL

7

Circle

9

Land

11

Drift

13

Sport

14

Flip

15

AutoTune

16

PosHold

17

Brake

18

Throw

19

Avoid_ADSB

20

Guided_NoGPS

21

Smart_RTL

22

FlowHold

23

Follow

24

ZigZag

25

SystemID

26

Heli_Autorotate

27

Auto RTL

28

Turtle

FLTMODE6: Flight Mode 6

Flight mode when pwm of Flightmode channel(FLTMODE_CH) is >=1750

Values

Value

Meaning

0

Stabilize

1

Acro

2

AltHold

3

Auto

4

Guided

5

Loiter

6

RTL

7

Circle

9

Land

11

Drift

13

Sport

14

Flip

15

AutoTune

16

PosHold

17

Brake

18

Throw

19

Avoid_ADSB

20

Guided_NoGPS

21

Smart_RTL

22

FlowHold

23

Follow

24

ZigZag

25

SystemID

26

Heli_Autorotate

27

Auto RTL

28

Turtle

FLTMODE_CH: Flightmode channel

Note: This parameter is for advanced users

RC Channel to use for flight mode control

Values

Value

Meaning

0

Disabled

5

Channel5

6

Channel6

7

Channel7

8

Channel8

9

Channel9

10

Channel 10

11

Channel 11

12

Channel 12

13

Channel 13

14

Channel 14

15

Channel 15

INITIAL_MODE: Initial flight mode

Note: This parameter is for advanced users

This selects the mode to start in on boot. This is useful for when you want to start in AUTO mode on boot without a receiver.

Values

Value

Meaning

0

Stabilize

1

Acro

2

AltHold

3

Auto

4

Guided

5

Loiter

6

RTL

7

Circle

9

Land

11

Drift

13

Sport

14

Flip

15

AutoTune

16

PosHold

17

Brake

18

Throw

19

Avoid_ADSB

20

Guided_NoGPS

21

Smart_RTL

22

FlowHold

23

Follow

24

ZigZag

25

SystemID

26

Heli_Autorotate

SIMPLE: Simple mode bitmask

Note: This parameter is for advanced users

Bitmask which holds which flight modes use simple heading mode (eg bit 0 = 1 means Flight Mode 0 uses simple mode). The bitmask is for flightmode switch positions.

Bitmask

Bit

Meaning

0

SwitchPos1

1

SwitchPos2

2

SwitchPos3

3

SwitchPos4

4

SwitchPos5

5

SwitchPos6

LOG_BITMASK: Log bitmask

Bitmap of what on-board log types to enable. This value is made up of the sum of each of the log types you want to be saved. It is usually best just to enable all basiclog types by setting this to 65535.

Bitmask

Bit

Meaning

0

Fast Attitude

1

Medium Attitude

2

GPS

3

System Performance

4

Control Tuning

5

Navigation Tuning

6

RC input

7

IMU

8

Mission Commands

9

Battery Monitor

10

RC output

11

Optical Flow

12

PID

13

Compass

15

Camera

17

Motors

18

Fast IMU

19

Raw IMU

20

Video Stabilization

21

Fast harmonic notch logging

ESC_CALIBRATION: ESC Calibration

Note: This parameter is for advanced users

Controls whether ArduCopter will enter ESC calibration on the next restart. Do not adjust this parameter manually.

Values

Value

Meaning

0

Normal Start-up

1

Start-up in ESC Calibration mode if throttle high

2

Start-up in ESC Calibration mode regardless of throttle

3

Start-up and automatically calibrate ESCs

9

Disabled

TUNE: Channel 6 Tuning

Controls which parameters (normally PID gains) are being tuned with transmitter's channel 6 knob

Values

Value

Meaning

0

None

1

Stab Roll/Pitch kP

4

Rate Roll/Pitch kP

5

Rate Roll/Pitch kI

21

Rate Roll/Pitch kD

3

Stab Yaw kP

6

Rate Yaw kP

26

Rate Yaw kD

56

Rate Yaw Filter

55

Motor Yaw Headroom

14

AltHold kP

7

Throttle Rate kP

34

Throttle Accel kP

35

Throttle Accel kI

36

Throttle Accel kD

12

Loiter Pos kP

22

Velocity XY kP

28

Velocity XY kI

10

WP Speed

25

Acro Roll/Pitch deg/s

40

Acro Yaw deg/s

45

RC Feel

13

Heli Ext Gyro

38

Declination

39

Circle Rate

46

Rate Pitch kP

47

Rate Pitch kI

48

Rate Pitch kD

49

Rate Roll kP

50

Rate Roll kI

51

Rate Roll kD

52

Rate Pitch FF

53

Rate Roll FF

54

Rate Yaw FF

58

SysID Magnitude

59

PSC Angle Max

FRAME_TYPE: Frame Type (+, X, V, etc)

Note: Reboot required after change

Controls motor mixing for multicopters. Not used for Tri or Traditional Helicopters.

Values

Value

Meaning

0

Plus

1

X

2

V

3

H

4

V-Tail

5

A-Tail

10

Y6B

11

Y6F

12

BetaFlightX

13

DJIX

14

ClockwiseX

15

I

18

BetaFlightXReversed

19

Y4

DISARM_DELAY: Disarm delay

Note: This parameter is for advanced users

Delay before automatic disarm in seconds after landing touchdown detection. A value of zero disables auto disarm. If Emergency Motor stop active, delay time is half this value.

Range

Units

0 to 127

seconds

ANGLE_MAX: Angle Max

Note: This parameter is for advanced users

Maximum lean angle in all flight modes

Increment

Range

Units

10

1000 to 8000

centidegrees

PHLD_BRAKE_RATE: PosHold braking rate

Note: This parameter is for advanced users

PosHold flight mode's rotation rate during braking in deg/sec

Range

Units

4 to 12

degrees per second

PHLD_BRAKE_ANGLE: PosHold braking angle max

Note: This parameter is for advanced users

PosHold flight mode's max lean angle during braking in centi-degrees

Increment

Range

Units

10

2000 to 4500

centidegrees

LAND_REPOSITION: Land repositioning

Note: This parameter is for advanced users

Enables user input during LAND mode, the landing phase of RTL, and auto mode landings.

Values

Value

Meaning

0

No repositioning

1

Repositioning

FS_EKF_ACTION: EKF Failsafe Action

Note: This parameter is for advanced users

Controls the action that will be taken when an EKF failsafe is invoked

Values

Value

Meaning

1

Land

2

AltHold

3

Land even in Stabilize

FS_EKF_THRESH: EKF failsafe variance threshold

Note: This parameter is for advanced users

Allows setting the maximum acceptable compass, velocity, position and height variances. Used in arming check and EKF failsafe.

Values

Value

Meaning

0.6

Strict

0.8

Default

1.0

Relaxed

FS_CRASH_CHECK: Crash check enable

Note: This parameter is for advanced users

This enables automatic crash checking. When enabled the motors will disarm if a crash is detected.

Values

Value

Meaning

0

Disabled

1

Enabled

RC_SPEED: ESC Update Speed

Note: This parameter is for advanced users

This is the speed in Hertz that your ESCs will receive updates

Increment

Range

Units

1

50 to 490

hertz

ACRO_BAL_ROLL: Acro Balance Roll

Note: This parameter is for advanced users

rate at which roll angle returns to level in acro and sport mode. A higher value causes the vehicle to return to level faster. For helicopter sets the decay rate of the virtual flybar in the roll axis. A higher value causes faster decay of desired to actual attitude.

Increment

Range

0.1

0 to 3

ACRO_BAL_PITCH: Acro Balance Pitch

Note: This parameter is for advanced users

rate at which pitch angle returns to level in acro and sport mode. A higher value causes the vehicle to return to level faster. For helicopter sets the decay rate of the virtual flybar in the pitch axis. A higher value causes faster decay of desired to actual attitude.

Increment

Range

0.1

0 to 3

ACRO_TRAINER: Acro Trainer

Note: This parameter is for advanced users

Type of trainer used in acro mode

Values

Value

Meaning

0

Disabled

1

Leveling

2

Leveling and Limited

THROW_MOT_START: Start motors before throwing is detected

Used by Throw mode. Controls whether motors will run at the speed set by MOT_SPIN_MIN or will be stopped when armed and waiting for the throw.

Values

Value

Meaning

0

Stopped

1

Running

THROW_ALT_MIN: Throw mode minimum altitude

Note: This parameter is for advanced users

Minimum altitude above which Throw mode will detect a throw or a drop - 0 to disable the check

Units

meters

THROW_ALT_MAX: Throw mode maximum altitude

Note: This parameter is for advanced users

Maximum altitude under which Throw mode will detect a throw or a drop - 0 to disable the check

Units

meters

THROW_NEXTMODE: Throw mode's follow up mode

Vehicle will switch to this mode after the throw is successfully completed. Default is to stay in throw mode (18)

Values

Value

Meaning

3

Auto

4

Guided

5

LOITER

6

RTL

9

Land

17

Brake

18

Throw

THROW_TYPE: Type of Type

Used by Throw mode. Specifies whether Copter is thrown upward or dropped.

Values

Value

Meaning

0

Upward Throw

1

Drop

GND_EFFECT_COMP: Ground Effect Compensation Enable/Disable

Note: This parameter is for advanced users

Ground Effect Compensation Enable/Disable

Values

Value

Meaning

0

Disabled

1

Enabled

DEV_OPTIONS: Development options

Note: This parameter is for advanced users

Bitmask of developer options. The meanings of the bit fields in this parameter may vary at any time. Developers should check the source code for current meaning

Bitmask

Bit

Meaning

0

ADSBMavlinkProcessing

1

DevOptionVFR_HUDRelativeAlt

ACRO_THR_MID: Acro Thr Mid

Note: This parameter is for advanced users

Acro Throttle Mid

Range

0 to 1

SYSID_ENFORCE: GCS sysid enforcement

Note: This parameter is for advanced users

This controls whether packets from other than the expected GCS system ID will be accepted

Values

Value

Meaning

0

NotEnforced

1

Enforced

FRAME_CLASS: Frame Class

Note: Reboot required after change

Controls major frame class for multicopter component

Values

Value

Meaning

0

Undefined

1

Quad

2

Hexa

3

Octa

4

OctaQuad

5

Y6

6

Heli

7

Tri

8

SingleCopter

9

CoaxCopter

10

BiCopter

11

Heli_Dual

12

DodecaHexa

13

HeliQuad

14

Deca

15

Scripting Matrix

16

6DoF Scripting

17

Dynamic Scripting Matrix

PILOT_SPEED_DN: Pilot maximum vertical speed descending

The maximum vertical descending velocity the pilot may request in cm/s. If 0 PILOT_SPEED_UP value is used.

Increment

Range

Units

10

0 to 500

centimeters per second

LAND_ALT_LOW: Land alt low

Note: This parameter is for advanced users

Altitude during Landing at which vehicle slows to LAND_SPEED

Increment

Range

Units

10

100 to 10000

centimeters

TUNE_MIN: Tuning minimum

Minimum value that the parameter currently being tuned with the transmitter's channel 6 knob will be set to

TUNE_MAX: Tuning maximum

Maximum value that the parameter currently being tuned with the transmitter's channel 6 knob will be set to

FS_VIBE_ENABLE: Vibration Failsafe enable

This enables the vibration failsafe which will use modified altitude estimation and control during high vibrations

Values

Value

Meaning

0

Disabled

1

Enabled

FS_OPTIONS: Failsafe options bitmask

Note: This parameter is for advanced users

Bitmask of additional options for battery, radio, & GCS failsafes. 0 (default) disables all options.

Bitmask

Bit

Meaning

0

Continue if in Auto on RC failsafe

1

Continue if in Auto on GCS failsafe

2

Continue if in Guided on RC failsafe

3

Continue if landing on any failsafe

4

Continue if in pilot controlled modes on GCS failsafe

5

Release Gripper

ACRO_OPTIONS: Acro mode options

Note: This parameter is for advanced users

A range of options that can be applied to change acro mode behaviour. Air-mode enables ATC_THR_MIX_MAN at all times (air-mode has no effect on helicopters). Rate Loop Only disables the use of angle stabilization and uses angular rate stabilization only.

Bitmask

Bit

Meaning

0

Air-mode

1

Rate Loop Only

AUTO_OPTIONS: Auto mode options

Note: This parameter is for advanced users

A range of options that can be applied to change auto mode behaviour. Allow Arming allows the copter to be armed in Auto. Allow Takeoff Without Raising Throttle allows takeoff without the pilot having to raise the throttle. Ignore pilot yaw overrides the pilot's yaw stick being used while in auto.

Bitmask

Bit

Meaning

0

Allow Arming

1

Allow Takeoff Without Raising Throttle

2

Ignore pilot yaw

7

Allow weathervaning

GUID_OPTIONS: Guided mode options

Note: This parameter is for advanced users

Options that can be applied to change guided mode behaviour

Bitmask

Bit

Meaning

0

Allow Arming from Transmitter

2

Ignore pilot yaw

3

SetAttitudeTarget interprets Thrust As Thrust

4

Do not stabilize PositionXY

5

Do not stabilize VelocityXY

6

Waypoint navigation used for position targets

7

Allow weathervaning

FS_GCS_TIMEOUT: GCS failsafe timeout

Timeout before triggering the GCS failsafe

Increment

Range

Units

1

2 to 120

seconds

RTL_OPTIONS: RTL mode options

Note: This parameter is for advanced users

Options that can be applied to change RTL mode behaviour

Bitmask

Bit

Meaning

2

Ignore pilot yaw

FLIGHT_OPTIONS: Flight mode options

Note: This parameter is for advanced users

Flight mode specific options

Bitmask

Bit

Meaning

0

Disable thrust loss check

1

Disable yaw imbalance warning

2

Release gripper on thrust loss

3

Require position for arming

RNGFND_FILT: Rangefinder filter

Note: Reboot required after change

Rangefinder filter to smooth distance. Set to zero to disable filtering

Increment

Range

Units

0.05

0 to 5

hertz

GUID_TIMEOUT: Guided mode timeout

Note: This parameter is for advanced users

Guided mode timeout after which vehicle will stop or return to level if no updates are received from caller. Only applicable during any combination of velocity, acceleration, angle control, and/or angular rate control

Range

Units

0.1 to 5

seconds

SURFTRAK_MODE: Surface Tracking Mode

Note: This parameter is for advanced users
Note: Reboot required after change

set which surface to track in surface tracking

Values

Value

Meaning

0

Do not track

1

Ground

2

Ceiling

FS_DR_ENABLE: DeadReckon Failsafe Action

Failsafe action taken immediately as deadreckoning starts. Deadreckoning starts when EKF loses position and velocity source and relies only on wind estimates

Values

Value

Meaning

0

Disabled/NoAction

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

6

Auto DO_LAND_START or RTL

FS_DR_TIMEOUT: DeadReckon Failsafe Timeout

DeadReckoning is available for this many seconds after losing position and/or velocity source. After this timeout elapses the EKF failsafe will trigger in modes requiring a position estimate

Range

0 to 120

ACRO_RP_RATE: Acro Roll and Pitch Rate

Acro mode maximum roll and pitch rate. Higher values mean faster rate of rotation

Range

Units

1 to 1080

degrees per second

ACRO_RP_EXPO: Acro Roll/Pitch Expo

Note: This parameter is for advanced users

Acro roll/pitch Expo to allow faster rotation when stick at edges

Range

Values

-0.5 to 0.95

Value

Meaning

0

Disabled

0.1

Very Low

0.2

Low

0.3

Medium

0.4

High

0.5

Very High

ACRO_RP_RATE_TC: Acro roll/pitch rate control input time constant

Acro roll and pitch rate control input time constant. Low numbers lead to sharper response, higher numbers to softer response

Increment

Range

Units

Values

0.01

0 to 1

seconds

Value

Meaning

0.5

Very Soft

0.2

Soft

0.15

Medium

0.1

Crisp

0.05

Very Crisp

ACRO_Y_RATE: Acro Yaw Rate

Acro mode maximum yaw rate. Higher value means faster rate of rotation

Range

Units

1 to 360

degrees per second

ACRO_Y_EXPO: Acro Yaw Expo

Note: This parameter is for advanced users

Acro yaw expo to allow faster rotation when stick at edges

Range

Values

-1.0 to 0.95

Value

Meaning

0

Disabled

0.1

Very Low

0.2

Low

0.3

Medium

0.4

High

0.5

Very High

ACRO_Y_RATE_TC: Acro yaw rate control input time constant

Acro yaw rate control input time constant. Low numbers lead to sharper response, higher numbers to softer response

Increment

Range

Units

Values

0.01

0 to 1

seconds

Value

Meaning

0.5

Very Soft

0.2

Soft

0.15

Medium

0.1

Crisp

0.05

Very Crisp

PILOT_Y_RATE: Pilot controlled yaw rate

Pilot controlled yaw rate max. Used in all pilot controlled modes except Acro

Range

Units

1 to 360

degrees per second

PILOT_Y_EXPO: Pilot controlled yaw expo

Note: This parameter is for advanced users

Pilot controlled yaw expo to allow faster rotation when stick at edges

Range

Values

-0.5 to 1.0

Value

Meaning

0

Disabled

0.1

Very Low

0.2

Low

0.3

Medium

0.4

High

0.5

Very High

PILOT_Y_RATE_TC: Pilot yaw rate control input time constant

Pilot yaw rate control input time constant. Low numbers lead to sharper response, higher numbers to softer response

Increment

Range

Units

Values

0.01

0 to 1

seconds

Value

Meaning

0.5

Very Soft

0.2

Soft

0.15

Medium

0.1

Crisp

0.05

Very Crisp

TKOFF_SLEW_TIME: Slew time of throttle during take-off

Time to slew the throttle from minimum to maximum while checking for a succsessful takeoff.

Range

Units

0.25 to 5.0

seconds

TKOFF_RPM_MIN: Takeoff Check RPM minimum

Takeoff is not permitted until motors report at least this RPM. Set to zero to disable check

Range

0 to 10000

PLDP_THRESH: Payload Place thrust ratio threshold

Ratio of vertical thrust during decent below which payload touchdown will trigger.

Range

0.5 to 0.9

PLDP_RNG_MAX: Payload Place maximum range finder altitude

Maximum range finder altitude in m to trigger payload touchdown, set to zero to disable.

Range

Units

0 to 100

meters

PLDP_DELAY: Payload Place climb delay

Delay after release, in seconds, before aircraft starts to climb back to starting altitude.

Range

Units

0 to 120

seconds

PLDP_SPEED_DN: Payload Place decent speed

The maximum vertical decent velocity in m/s. If 0 LAND_SPEED value is used.

Range

Units

0 to 5

meters per second

SURFTRAK_TC: Surface Tracking Filter Time Constant

Note: This parameter is for advanced users

Time to achieve 63.2% of the surface altitude measurement change. If 0 filtering is disabled

Range

Units

0 to 5

seconds

TKOFF_THR_MAX: Takeoff maximum throttle during take-off ramp up

Note: This parameter is for advanced users

Takeoff maximum throttle allowed before controllers assume the aircraft is airborne during the takeoff process.

Range

0.0 to 0.9

TKOFF_RPM_MAX: Takeoff Check RPM maximum

Takeoff is not permitted until motors report no more than this RPM. Set to zero to disable check

Range

0 to 10000

FS_EKF_FILT: EKF Failsafe filter cutoff

Note: This parameter is for advanced users

EKF Failsafe filter cutoff frequency. EKF variances are filtered using this value to avoid spurious failsafes from transient high variances. A higher value means the failsafe is more likely to trigger.

Range

Units

0 to 10

hertz

VEHICLE Parameters

FLTMODE_GCSBLOCK: Flight mode block from GCS

Bitmask of flight modes to disable for GCS selection. Mode can still be accessed via RC or failsafe.

Bitmask

Bit

Meaning

0

Stabilize

1

Acro

2

AltHold

3

Auto

4

Guided

5

Loiter

6

Circle

7

Drift

8

Sport

9

Flip

10

AutoTune

11

PosHold

12

Brake

13

Throw

14

Avoid_ADSB

15

Guided_NoGPS

16

Smart_RTL

17

FlowHold

18

Follow

19

ZigZag

20

SystemID

21

Heli_Autorotate

22

Auto RTL

23

Turtle

ADSB_ Parameters

ADSB_TYPE: ADSB Type

Note: Reboot required after change

Type of ADS-B hardware for ADSB-in and ADSB-out configuration and operation. If any type is selected then MAVLink based ADSB-in messages will always be enabled

Values

Value

Meaning

0

Disabled

1

uAvionix-MAVLink

2

Sagetech

3

uAvionix-UCP

4

Sagetech MX Series

ADSB_LIST_MAX: ADSB vehicle list size

Note: This parameter is for advanced users
Note: Reboot required after change

ADSB list size of nearest vehicles. Longer lists take longer to refresh with lower SRx_ADSB values.

Range

1 to 100

ADSB_LIST_RADIUS: ADSB vehicle list radius filter

Note: This parameter is for advanced users

ADSB vehicle list radius filter. Vehicles detected outside this radius will be completely ignored. They will not show up in the SRx_ADSB stream to the GCS and will not be considered in any avoidance calculations. A value of 0 will disable this filter.

Range

Units

0 to 100000

meters

ADSB_ICAO_ID: ICAO_ID vehicle identification number

Note: This parameter is for advanced users

ICAO_ID unique vehicle identification number of this aircraft. This is an integer limited to 24bits. If set to 0 then one will be randomly generated. If set to -1 then static information is not sent, transceiver is assumed pre-programmed.

Range

-1 to 16777215

ADSB_EMIT_TYPE: Emitter type

Note: This parameter is for advanced users

ADSB classification for the type of vehicle emitting the transponder signal. Default value is 14 (UAV).

Values

Value

Meaning

0

NoInfo

1

Light

2

Small

3

Large

4

HighVortexlarge

5

Heavy

6

HighlyManuv

7

Rotocraft

8

RESERVED

9

Glider

10

LightAir

11

Parachute

12

UltraLight

13

RESERVED

14

UAV

15

Space

16

RESERVED

17

EmergencySurface

18

ServiceSurface

19

PointObstacle

ADSB_LEN_WIDTH: Aircraft length and width

Note: This parameter is for advanced users

Aircraft length and width dimension options in Length and Width in meters. In most cases, use a value of 1 for smallest size.

Values

Value

Meaning

0

NO_DATA

1

L15W23

2

L25W28P5

3

L25W34

4

L35W33

5

L35W38

6

L45W39P5

7

L45W45

8

L55W45

9

L55W52

10

L65W59P5

11

L65W67

12

L75W72P5

13

L75W80

14

L85W80

15

L85W90

ADSB_OFFSET_LAT: GPS antenna lateral offset

Note: This parameter is for advanced users

GPS antenna lateral offset. This describes the physical location offset from center of the GPS antenna on the aircraft.

Values

Value

Meaning

0

NoData

1

Left2m

2

Left4m

3

Left6m

4

Center

5

Right2m

6

Right4m

7

Right6m

ADSB_OFFSET_LON: GPS antenna longitudinal offset

Note: This parameter is for advanced users

GPS antenna longitudinal offset. This is usually set to 1, Applied By Sensor

Values

Value

Meaning

0

NO_DATA

1

AppliedBySensor

ADSB_RF_SELECT: Transceiver RF selection

Note: This parameter is for advanced users

Transceiver RF selection for Rx enable and/or Tx enable. This only effects devices that can Tx and/or Rx. Rx-only devices should override this to always be Rx-only.

Bitmask

Bit

Meaning

0

Rx

1

Tx

ADSB_SQUAWK: Squawk code

Note: This parameter is for advanced users

VFR squawk (Mode 3/A) code is a pre-programmed default code when the pilot is flying VFR and not in contact with ATC. In the USA, the VFR squawk code is octal 1200 (hex 0x280, decimal 640) and in most parts of Europe the VFR squawk code is octal 7000. If an invalid octal number is set then it will be reset to 1200.

Range

Units

0 to 7777

octal

ADSB_RF_CAPABLE: RF capabilities

Note: This parameter is for advanced users

Describes your hardware RF In/Out capabilities.

Bitmask

Bit

Meaning

0

UAT_in

1

1090ES_in

2

UAT_out

3

1090ES_out

ADSB_LIST_ALT: ADSB vehicle list altitude filter

Note: This parameter is for advanced users

ADSB vehicle list altitude filter. Vehicles detected above this altitude will be completely ignored. They will not show up in the SRx_ADSB stream to the GCS and will not be considered in any avoidance calculations. A value of 0 will disable this filter.

Range

Units

0 to 32767

meters

ADSB_ICAO_SPECL: ICAO_ID of special vehicle

Note: This parameter is for advanced users

ICAO_ID of special vehicle that ignores ADSB_LIST_RADIUS and ADSB_LIST_ALT. The vehicle is always tracked. Use 0 to disable.

ADSB_LOG: ADS-B logging

Note: This parameter is for advanced users

0: no logging, 1: log only special ID, 2:log all

Values

Value

Meaning

0

no logging

1

log only special ID

2

log all

ADSB_OPTIONS: ADS-B Options

Note: This parameter is for advanced users

Options for emergency failsafe codes and device capabilities

Bitmask

Bit

Meaning

0

Ping200X Send GPS

1

Squawk 7400 on RC failsafe

2

Squawk 7400 on GCS failsafe

3

Sagetech MXS use External Config

AFS_ Parameters

AFS_ENABLE: Enable Advanced Failsafe

Note: This parameter is for advanced users

This enables the advanced failsafe system. If this is set to zero (disable) then all the other AFS options have no effect

AFS_MAN_PIN: Manual Pin

Note: This parameter is for advanced users

This sets a digital output pin to set high when in manual mode. See the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

AFS_HB_PIN: Heartbeat Pin

Note: This parameter is for advanced users

This sets a digital output pin which is cycled at 10Hz when termination is not activated. Note that if a FS_TERM_PIN is set then the heartbeat pin will continue to cycle at 10Hz when termination is activated, to allow the termination board to distinguish between autopilot crash and termination. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

AFS_WP_COMMS: Comms Waypoint

Note: This parameter is for advanced users

Waypoint number to navigate to on comms loss

AFS_WP_GPS_LOSS: GPS Loss Waypoint

Note: This parameter is for advanced users

Waypoint number to navigate to on GPS lock loss

AFS_TERMINATE: Force Terminate

Note: This parameter is for advanced users

Can be set in flight to force termination of the heartbeat signal

AFS_TERM_ACTION: Terminate action

Note: This parameter is for advanced users

This can be used to force an action on flight termination. Normally this is handled by an external failsafe board, but you can setup ArduPilot to handle it here. Please consult the wiki for more information on the possible values of the parameter

AFS_TERM_PIN: Terminate Pin

Note: This parameter is for advanced users

This sets a digital output pin to set high on flight termination. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

AFS_AMSL_LIMIT: AMSL limit

Note: This parameter is for advanced users

This sets the AMSL (above mean sea level) altitude limit. If the pressure altitude determined by QNH exceeds this limit then flight termination will be forced. Note that this limit is in meters, whereas pressure altitude limits are often quoted in feet. A value of zero disables the pressure altitude limit.

Units

meters

AFS_AMSL_ERR_GPS: Error margin for GPS based AMSL limit

Note: This parameter is for advanced users

This sets margin for error in GPS derived altitude limit. This error margin is only used if the barometer has failed. If the barometer fails then the GPS will be used to enforce the AMSL_LIMIT, but this margin will be subtracted from the AMSL_LIMIT first, to ensure that even with the given amount of GPS altitude error the pressure altitude is not breached. OBC users should set this to comply with their D2 safety case. A value of -1 will mean that barometer failure will lead to immediate termination.

Units

meters

AFS_QNH_PRESSURE: QNH pressure

Note: This parameter is for advanced users

This sets the QNH pressure in millibars to be used for pressure altitude in the altitude limit. A value of zero disables the altitude limit.

Units

hectopascal

AFS_MAX_GPS_LOSS: Maximum number of GPS loss events

Note: This parameter is for advanced users

Maximum number of GPS loss events before the aircraft stops returning to mission on GPS recovery. Use zero to allow for any number of GPS loss events.

AFS_MAX_COM_LOSS: Maximum number of comms loss events

Note: This parameter is for advanced users

Maximum number of comms loss events before the aircraft stops returning to mission on comms recovery. Use zero to allow for any number of comms loss events.

AFS_GEOFENCE: Enable geofence Advanced Failsafe

Note: This parameter is for advanced users

This enables the geofence part of the AFS. Will only be in effect if AFS_ENABLE is also 1

AFS_RC: Enable RC Advanced Failsafe

Note: This parameter is for advanced users

This enables the RC part of the AFS. Will only be in effect if AFS_ENABLE is also 1

AFS_RC_MAN_ONLY: Enable RC Termination only in manual control modes

Note: This parameter is for advanced users

If this parameter is set to 1, then an RC loss will only cause the plane to terminate in manual control modes. If it is 0, then the plane will terminate in any flight mode.

AFS_DUAL_LOSS: Enable dual loss terminate due to failure of both GCS and GPS simultaneously

Note: This parameter is for advanced users

This enables the dual loss termination part of the AFS system. If this parameter is 1 and both GPS and the ground control station fail simultaneously, this will be considered a "dual loss" and cause termination.

AFS_RC_FAIL_TIME: RC failure time

Note: This parameter is for advanced users

This is the time in seconds in manual mode that failsafe termination will activate if RC input is lost. For the OBC rules this should be (1.5). Use 0 to disable.

Units

seconds

AFS_MAX_RANGE: Max allowed range

Note: This parameter is for advanced users

This is the maximum range of the vehicle in kilometers from first arming. If the vehicle goes beyond this range then the TERM_ACTION is performed. A value of zero disables this feature.

Units

kilometers

AFS_OPTIONS: AFS options

See description for each bitmask bit description

Bitmask

Bit

Meaning

0

Continue the mission even after comms are recovered (does not go to the mission item at the time comms were lost)

1

Enable AFS for all autonomous modes (not just AUTO)

AFS_GCS_TIMEOUT: GCS timeout

Note: This parameter is for advanced users

The time (in seconds) of persistent data link loss before GCS failsafe occurs.

Units

seconds

AHRS_ Parameters

AHRS_GPS_GAIN: AHRS GPS gain

Note: This parameter is for advanced users

This controls how much to use the GPS to correct the attitude. This should never be set to zero for a plane as it would result in the plane losing control in turns. For a plane please use the default value of 1.0.

Increment

Range

.01

0.0 to 1.0

AHRS_GPS_USE: AHRS use GPS for DCM navigation and position-down

Note: This parameter is for advanced users

This controls whether to use dead-reckoning or GPS based navigation. If set to 0 then the GPS won't be used for navigation, and only dead reckoning will be used. A value of zero should never be used for normal flight. Currently this affects only the DCM-based AHRS: the EKF uses GPS according to its own parameters. A value of 2 means to use GPS for height as well as position - both in DCM estimation and when determining altitude-above-home.

Values

Value

Meaning

0

Disabled

1

Use GPS for DCM position

2

Use GPS for DCM position and height

AHRS_YAW_P: Yaw P

Note: This parameter is for advanced users

This controls the weight the compass or GPS has on the heading. A higher value means the heading will track the yaw source (GPS or compass) more rapidly.

Increment

Range

.01

0.1 to 0.4

AHRS_RP_P: AHRS RP_P

Note: This parameter is for advanced users

This controls how fast the accelerometers correct the attitude

Increment

Range

.01

0.1 to 0.4

AHRS_WIND_MAX: Maximum wind

Note: This parameter is for advanced users

This sets the maximum allowable difference between ground speed and airspeed. A value of zero means to use the airspeed as is. This allows the plane to cope with a failing airspeed sensor by clipping it to groundspeed plus/minus this limit. See ARSPD_OPTIONS and ARSPD_WIND_MAX to disable airspeed sensors.

Increment

Range

Units

1

0 to 127

meters per second

AHRS_TRIM_X: AHRS Trim Roll

Compensates for the roll angle difference between the control board and the frame. Positive values make the vehicle roll right.

Increment

Range

Units

0.01

-0.1745 to +0.1745

radians

AHRS_TRIM_Y: AHRS Trim Pitch

Compensates for the pitch angle difference between the control board and the frame. Positive values make the vehicle pitch up/back.

Increment

Range

Units

0.01

-0.1745 to +0.1745

radians

AHRS_TRIM_Z: AHRS Trim Yaw

Note: This parameter is for advanced users

Not Used

Increment

Range

Units

0.01

-0.1745 to +0.1745

radians

AHRS_ORIENTATION: Board Orientation

Note: This parameter is for advanced users

Overall board orientation relative to the standard orientation for the board type. This rotates the IMU and compass readings to allow the board to be oriented in your vehicle at any 90 or 45 degree angle. The label for each option is specified in the order of rotations for that orientation. This option takes affect on next boot. After changing you will need to re-level your vehicle. Firmware versions 4.2 and prior can use a CUSTOM (100) rotation to set the AHRS_CUSTOM_ROLL/PIT/YAW angles for AHRS orientation. Later versions provide two general custom rotations which can be used, Custom 1 and Custom 2, with CUST_ROT1_ROLL/PIT/YAW or CUST_ROT2_ROLL/PIT/YAW angles.

Values

Value

Meaning

0

None

1

Yaw45

2

Yaw90

3

Yaw135

4

Yaw180

5

Yaw225

6

Yaw270

7

Yaw315

8

Roll180

9

Yaw45Roll180

10

Yaw90Roll180

11

Yaw135Roll180

12

Pitch180

13

Yaw225Roll180

14

Yaw270Roll180

15

Yaw315Roll180

16

Roll90

17

Yaw45Roll90

18

Yaw90Roll90

19

Yaw135Roll90

20

Roll270

21

Yaw45Roll270

22

Yaw90Roll270

23

Yaw135Roll270

24

Pitch90

25

Pitch270

26

Yaw90Pitch180

27

Yaw270Pitch180

28

Pitch90Roll90

29

Pitch90Roll180

30

Pitch90Roll270

31

Pitch180Roll90

32

Pitch180Roll270

33

Pitch270Roll90

34

Pitch270Roll180

35

Pitch270Roll270

36

Yaw90Pitch180Roll90

37

Yaw270Roll90

38

Yaw293Pitch68Roll180

39

Pitch315

40

Pitch315Roll90

42

Roll45

43

Roll315

100

Custom 4.1 and older

101

Custom 1

102

Custom 2

AHRS_COMP_BETA: AHRS Velocity Complementary Filter Beta Coefficient

Note: This parameter is for advanced users

This controls the time constant for the cross-over frequency used to fuse AHRS (airspeed and heading) and GPS data to estimate ground velocity. Time constant is 0.1/beta. A larger time constant will use GPS data less and a small time constant will use air data less.

Increment

Range

.01

0.001 to 0.5

AHRS_GPS_MINSATS: AHRS GPS Minimum satellites

Note: This parameter is for advanced users

Minimum number of satellites visible to use GPS for velocity based corrections attitude correction. This defaults to 6, which is about the point at which the velocity numbers from a GPS become too unreliable for accurate correction of the accelerometers.

Increment

Range

1

0 to 10

AHRS_EKF_TYPE: Use NavEKF Kalman filter for attitude and position estimation

Note: This parameter is for advanced users

This controls which NavEKF Kalman filter version is used for attitude and position estimation

Values

Value

Meaning

0

Disabled

2

Enable EKF2

3

Enable EKF3

11

ExternalAHRS

AHRS_CUSTOM_ROLL: Board orientation roll offset

Note: This parameter is for advanced users

Autopilot mounting position roll offset. Positive values = roll right, negative values = roll left. This parameter is only used when AHRS_ORIENTATION is set to CUSTOM.

Increment

Range

Units

1

-180 to 180

degrees

AHRS_CUSTOM_PIT: Board orientation pitch offset

Note: This parameter is for advanced users

Autopilot mounting position pitch offset. Positive values = pitch up, negative values = pitch down. This parameter is only used when AHRS_ORIENTATION is set to CUSTOM.

Increment

Range

Units

1

-180 to 180

degrees

AHRS_CUSTOM_YAW: Board orientation yaw offset

Note: This parameter is for advanced users

Autopilot mounting position yaw offset. Positive values = yaw right, negative values = yaw left. This parameter is only used when AHRS_ORIENTATION is set to CUSTOM.

Increment

Range

Units

1

-180 to 180

degrees

AHRS_OPTIONS: Optional AHRS behaviour

Note: This parameter is for advanced users

This controls optional AHRS behaviour. Setting DisableDCMFallbackFW will change the AHRS behaviour for fixed wing aircraft in fly-forward flight to not fall back to DCM when the EKF stops navigating. Setting DisableDCMFallbackVTOL will change the AHRS behaviour for fixed wing aircraft in non fly-forward (VTOL) flight to not fall back to DCM when the EKF stops navigating. Setting DontDisableAirspeedUsingEKF disables the EKF based innovation check for airspeed consistency

Bitmask

Bit

Meaning

0

DisableDCMFallbackFW

1

DisableDCMFallbackVTOL

2

DontDisableAirspeedUsingEKF

AIS_ Parameters

AIS_TYPE: AIS receiver type

Note: Reboot required after change

AIS receiver type

Values

Value

Meaning

0

None

1

NMEA AIVDM message

AIS_LIST_MAX: AIS vessel list size

Note: This parameter is for advanced users

AIS list size of nearest vessels. Longer lists take longer to refresh with lower SRx_ADSB values.

Range

1 to 100

AIS_TIME_OUT: AIS vessel time out

Note: This parameter is for advanced users

if no updates are received in this time a vessel will be removed from the list

Range

Units

1 to 2000

seconds

AIS_LOGGING: AIS logging options

Note: This parameter is for advanced users

Bitmask of AIS logging options

Bitmask

Bit

Meaning

0

Log all AIVDM messages

1

Log only unsupported AIVDM messages

2

Log decoded messages

ARMING_ Parameters

ARMING_ACCTHRESH: Accelerometer error threshold

Note: This parameter is for advanced users

Accelerometer error threshold used to determine inconsistent accelerometers. Compares this error range to other accelerometers to detect a hardware or calibration error. Lower value means tighter check and harder to pass arming check. Not all accelerometers are created equal.

Range

Units

0.25 to 3.0

meters per square second

ARMING_RUDDER: Arming with Rudder enable/disable

Note: This parameter is for advanced users

Allow arm/disarm by rudder input. When enabled arming can be done with right rudder, disarming with left rudder. Rudder arming only works with throttle at zero +- deadzone (RCx_DZ). Depending on vehicle type, arming in certain modes is prevented. See the wiki for each vehicle. Caution is recommended when arming if it is allowed in an auto-throttle mode!

Values

Value

Meaning

0

Disabled

1

ArmingOnly

2

ArmOrDisarm

ARMING_MIS_ITEMS: Required mission items

Note: This parameter is for advanced users

Bitmask of mission items that are required to be planned in order to arm the aircraft

Bitmask

Bit

Meaning

0

Land

1

VTOL Land

2

DO_LAND_START

3

Takeoff

4

VTOL Takeoff

5

Rallypoint

6

RTL

ARMING_CHECK: Arm Checks to Perform (bitmask)

Checks prior to arming motor. This is a bitmask of checks that will be performed before allowing arming. For most users it is recommended to leave this at the default of 1 (all checks enabled). You can select whatever checks you prefer by adding together the values of each check type to set this parameter. For example, to only allow arming when you have GPS lock and no RC failsafe you would set ARMING_CHECK to 72.

Bitmask

Bit

Meaning

0

All

1

Barometer

2

Compass

3

GPS lock

4

INS

5

Parameters

6

RC Channels

7

Board voltage

8

Battery Level

10

Logging Available

11

Hardware safety switch

12

GPS Configuration

13

System

14

Mission

15

Rangefinder

16

Camera

17

AuxAuth

18

VisualOdometry

19

FFT

ARMING_OPTIONS: Arming options

Note: This parameter is for advanced users

Options that can be applied to change arming behaviour

Bitmask

Bit

Meaning

0

Disable prearm display

1

Do not send status text on state change

ARMING_MAGTHRESH: Compass magnetic field strength error threshold vs earth magnetic model

Note: This parameter is for advanced users

Compass magnetic field strength error threshold vs earth magnetic model. X and y axis are compared using this threhold, Z axis uses 2x this threshold. 0 to disable check

Range

Units

0 to 500

milligauss

ARMING_CRSDP_IGN: Disable CrashDump Arming check

Note: This parameter is for advanced users

Must have value "1" if crashdump data is present on the system, or a prearm failure will be raised. Do not set this parameter unless the risks of doing so are fully understood. The presence of a crash dump means that the firmware currently installed has suffered a critical software failure which resulted in the autopilot immediately rebooting. The crashdump file gives diagnostic information which can help in finding the issue, please contact the ArduPIlot support team. If this crashdump data is present, the vehicle is likely unsafe to fly. Check the ArduPilot documentation for more details.

Values

Value

Meaning

0

Crash Dump arming check active

1

Crash Dump arming check deactivated

AROT_ Parameters

AROT_ENABLE: Enable settings for RSC Setpoint

Note: This parameter is for advanced users

Allows you to enable (1) or disable (0) the autonomous autorotation capability.

Values

Value

Meaning

0

Disabled

1

Enabled

AROT_HS_P: P gain for head speed controller

Note: This parameter is for advanced users

Increase value to increase sensitivity of head speed controller during autonomous autorotation.

Increment

Range

0.01

0.3 to 1

AROT_HS_SET_PT: Target Head Speed

Note: This parameter is for advanced users

The target head speed in RPM during autorotation. Start by setting to desired hover speed and tune from there as necessary.

Increment

Range

Units

1

1000 to 2800

Revolutions Per Minute

AROT_TARG_SP: Target Glide Ground Speed

Note: This parameter is for advanced users

Target ground speed in cm/s for the autorotation controller to try and achieve/ maintain during the glide phase.

Increment

Range

Units

50

800 to 2000

centimeters per second

AROT_COL_FILT_E: Entry Phase Collective Filter

Note: This parameter is for advanced users

Cut-off frequency for collective low pass filter. For the entry phase. Acts as a following trim. Must be higher than AROT_COL_FILT_G.

Increment

Range

Units

0.01

0.2 to 0.5

hertz

AROT_COL_FILT_G: Glide Phase Collective Filter

Note: This parameter is for advanced users

Cut-off frequency for collective low pass filter. For the glide phase. Acts as a following trim. Must be lower than AROT_COL_FILT_E.

Increment

Range

Units

0.01

0.03 to 0.15

hertz

AROT_AS_ACC_MAX: Forward Acceleration Limit

Note: This parameter is for advanced users

Maximum forward acceleration to apply in speed controller.

Increment

Range

Units

10

30 to 60

centimeters per square second

AROT_HS_SENSOR: Main Rotor RPM Sensor

Note: This parameter is for advanced users

Allocate the RPM sensor instance to use for measuring head speed. RPM1 = 0. RPM2 = 1.

Increment

Range

Units

0.1

0.5 to 3

seconds

AROT_FW_V_P: Velocity (horizontal) P gain

Note: This parameter is for advanced users

Velocity (horizontal) P gain. Determines the proportion of the target acceleration based on the velocity error.

Increment

Range

0.1

0.1 to 6.0

AROT_FW_V_FF: Velocity (horizontal) feed forward

Note: This parameter is for advanced users

Velocity (horizontal) input filter. Corrects the target acceleration proportionally to the desired velocity.

Increment

Range

0.01

0 to 1

ARSPD Parameters

ARSPD_ENABLE: Airspeed Enable

Enable airspeed sensor support

Values

Value

Meaning

0

Disable

1

Enable

ARSPD_TUBE_ORDER: Control pitot tube order

Note: This parameter is for advanced users

This parameter allows you to control whether the order in which the tubes are attached to your pitot tube matters. If you set this to 0 then the first (often the top) connector on the sensor needs to be the stagnation pressure (the pressure at the tip of the pitot tube). If set to 1 then the second (often the bottom) connector needs to be the stagnation pressure. If set to 2 (the default) then the airspeed driver will accept either order. The reason you may wish to specify the order is it will allow your airspeed sensor to detect if the aircraft is receiving excessive pressure on the static port compared to the stagnation port such as during a stall, which would otherwise be seen as a positive airspeed.

Values

Value

Meaning

0

Normal

1

Swapped

2

Auto Detect

ARSPD_PRIMARY: Primary airspeed sensor

Note: This parameter is for advanced users

This selects which airspeed sensor will be the primary if multiple sensors are found

Values

Value

Meaning

0

FirstSensor

1

2ndSensor

ARSPD_OPTIONS: Airspeed options bitmask

Note: This parameter is for advanced users

This parameter and function is not used by this vehicle. Always set to 0.

Bitmask

Bit

Meaning

0

SpeedMismatchDisable

1

AllowSpeedMismatchRecovery

2

DisableVoltageCorrection

3

UseEkf3Consistency

4

ReportOffset

ARSPD_WIND_MAX: Maximum airspeed and ground speed difference

Note: This parameter is for advanced users

This parameter and function is not used by this vehicle. Always set to 0.

Units

meters per second

ARSPD_WIND_WARN: Airspeed and GPS speed difference that gives a warning

Note: This parameter is for advanced users

This parameter and function is not used by this vehicle. Always set to 0.

Units

meters per second

ARSPD_WIND_GATE: Re-enable Consistency Check Gate Size

Note: This parameter is for advanced users

This parameter and function is not used by this vehicle.

Range

0.0 to 10.0

ARSPD_OFF_PCNT: Maximum offset cal speed error

Note: This parameter is for advanced users

The maximum percentage speed change in airspeed reports that is allowed due to offset changes between calibrations before a warning is issued. This potential speed error is in percent of AIRSPEED_MIN. 0 disables. Helps warn of calibrations without pitot being covered.

Range

Units

0.0 to 10.0

percent

ARSPD2_ Parameters

ARSPD2_TYPE: Airspeed type

Type of airspeed sensor

Values

Value

Meaning

0

None

1

I2C-MS4525D0

2

Analog

3

I2C-MS5525

4

I2C-MS5525 (0x76)

5

I2C-MS5525 (0x77)

6

I2C-SDP3X

7

I2C-DLVR-5in

8

DroneCAN

9

I2C-DLVR-10in

10

I2C-DLVR-20in

11

I2C-DLVR-30in

12

I2C-DLVR-60in

13

NMEA water speed

14

MSP

15

ASP5033

16

ExternalAHRS

100

SITL

ARSPD2_USE: Airspeed use

This parameter is not used by this vehicle. Always set to 0.

Values

Value

Meaning

0

DoNotUse

1

Use

2

UseWhenZeroThrottle

ARSPD2_OFFSET: Airspeed offset

Note: This parameter is for advanced users

Airspeed calibration offset

Increment

0.1

ARSPD2_RATIO: Airspeed ratio

Note: This parameter is for advanced users

Calibrates pitot tube pressure to velocity. Increasing this value will indicate a higher airspeed at any given dynamic pressure.

Increment

0.1

ARSPD2_PIN: Airspeed pin

Note: This parameter is for advanced users

The pin number that the airspeed sensor is connected to for analog sensors. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

ARSPD2_AUTOCAL: This parameter and function is not used by this vehicle. Always set to 0.

Note: This parameter is for advanced users

Enables automatic adjustment of airspeed ratio during a calibration flight based on estimation of ground speed and true airspeed. New ratio saved every 2 minutes if change is > 5%. Should not be left enabled.

ARSPD2_TUBE_ORDR: Control pitot tube order

Note: This parameter is for advanced users

This parameter allows you to control whether the order in which the tubes are attached to your pitot tube matters. If you set this to 0 then the first (often the top) connector on the sensor needs to be the stagnation pressure (the pressure at the tip of the pitot tube). If set to 1 then the second (often the bottom) connector needs to be the stagnation pressure. If set to 2 (the default) then the airspeed driver will accept either order. The reason you may wish to specify the order is it will allow your airspeed sensor to detect if the aircraft is receiving excessive pressure on the static port compared to the stagnation port such as during a stall, which would otherwise be seen as a positive airspeed.

Values

Value

Meaning

0

Normal

1

Swapped

2

Auto Detect

ARSPD2_SKIP_CAL: Skip airspeed offset calibration on startup

Note: This parameter is for advanced users

This parameter allows you to skip airspeed offset calibration on startup, instead using the offset from the last calibration. This may be desirable if the offset variance between flights for your sensor is low and you want to avoid having to cover the pitot tube on each boot.

Values

Value

Meaning

0

Disable

1

Enable

ARSPD2_PSI_RANGE: The PSI range of the device

Note: This parameter is for advanced users

This parameter allows you to set the PSI (pounds per square inch) range for your sensor. You should not change this unless you examine the datasheet for your device

ARSPD2_BUS: Airspeed I2C bus

Note: This parameter is for advanced users
Note: Reboot required after change

Bus number of the I2C bus where the airspeed sensor is connected. May not correspond to board's I2C bus number labels. Retry another bus and reboot if airspeed sensor fails to initialize.

Values

Value

Meaning

0

Bus0

1

Bus1

2

Bus2

ARSPD2_DEVID: Airspeed ID

Note: This parameter is for advanced users

Airspeed sensor ID, taking into account its type, bus and instance

ReadOnly

True

ARSPD_ Parameters

ARSPD_TYPE: Airspeed type

Type of airspeed sensor

Values

Value

Meaning

0

None

1

I2C-MS4525D0

2

Analog

3

I2C-MS5525

4

I2C-MS5525 (0x76)

5

I2C-MS5525 (0x77)

6

I2C-SDP3X

7

I2C-DLVR-5in

8

DroneCAN

9

I2C-DLVR-10in

10

I2C-DLVR-20in

11

I2C-DLVR-30in

12

I2C-DLVR-60in

13

NMEA water speed

14

MSP

15

ASP5033

16

ExternalAHRS

100

SITL

ARSPD_USE: Airspeed use

This parameter is not used by this vehicle. Always set to 0.

Values

Value

Meaning

0

DoNotUse

1

Use

2

UseWhenZeroThrottle

ARSPD_OFFSET: Airspeed offset

Note: This parameter is for advanced users

Airspeed calibration offset

Increment

0.1

ARSPD_RATIO: Airspeed ratio

Note: This parameter is for advanced users

Calibrates pitot tube pressure to velocity. Increasing this value will indicate a higher airspeed at any given dynamic pressure.

Increment

0.1

ARSPD_PIN: Airspeed pin

Note: This parameter is for advanced users

The pin number that the airspeed sensor is connected to for analog sensors. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

ARSPD_AUTOCAL: This parameter and function is not used by this vehicle. Always set to 0.

Note: This parameter is for advanced users

Enables automatic adjustment of airspeed ratio during a calibration flight based on estimation of ground speed and true airspeed. New ratio saved every 2 minutes if change is > 5%. Should not be left enabled.

ARSPD_TUBE_ORDR: Control pitot tube order

Note: This parameter is for advanced users

This parameter allows you to control whether the order in which the tubes are attached to your pitot tube matters. If you set this to 0 then the first (often the top) connector on the sensor needs to be the stagnation pressure (the pressure at the tip of the pitot tube). If set to 1 then the second (often the bottom) connector needs to be the stagnation pressure. If set to 2 (the default) then the airspeed driver will accept either order. The reason you may wish to specify the order is it will allow your airspeed sensor to detect if the aircraft is receiving excessive pressure on the static port compared to the stagnation port such as during a stall, which would otherwise be seen as a positive airspeed.

Values

Value

Meaning

0

Normal

1

Swapped

2

Auto Detect

ARSPD_SKIP_CAL: Skip airspeed offset calibration on startup

Note: This parameter is for advanced users

This parameter allows you to skip airspeed offset calibration on startup, instead using the offset from the last calibration. This may be desirable if the offset variance between flights for your sensor is low and you want to avoid having to cover the pitot tube on each boot.

Values

Value

Meaning

0

Disable

1

Enable

ARSPD_PSI_RANGE: The PSI range of the device

Note: This parameter is for advanced users

This parameter allows you to set the PSI (pounds per square inch) range for your sensor. You should not change this unless you examine the datasheet for your device

ARSPD_BUS: Airspeed I2C bus

Note: This parameter is for advanced users
Note: Reboot required after change

Bus number of the I2C bus where the airspeed sensor is connected. May not correspond to board's I2C bus number labels. Retry another bus and reboot if airspeed sensor fails to initialize.

Values

Value

Meaning

0

Bus0

1

Bus1

2

Bus2

ARSPD_DEVID: Airspeed ID

Note: This parameter is for advanced users

Airspeed sensor ID, taking into account its type, bus and instance

ReadOnly

True

ATC_ Parameters

ATC_SLEW_YAW: Yaw target slew rate

Note: This parameter is for advanced users

Maximum rate the yaw target can be updated in RTL and Auto flight modes

Increment

Range

Units

100

500 to 18000

centidegrees per second

ATC_ACCEL_Y_MAX: Acceleration Max for Yaw

Note: This parameter is for advanced users

Maximum acceleration in yaw axis

Increment

Range

Units

Values

1000

0 to 72000

centidegrees per square second

Value

Meaning

0

Disabled

9000

VerySlow

18000

Slow

36000

Medium

54000

Fast

ATC_RATE_FF_ENAB: Rate Feedforward Enable

Note: This parameter is for advanced users

Controls whether body-frame rate feedforward is enabled or disabled

Values

Value

Meaning

0

Disabled

1

Enabled

ATC_ACCEL_R_MAX: Acceleration Max for Roll

Note: This parameter is for advanced users

Maximum acceleration in roll axis

Increment

Range

Units

Values

1000

0 to 180000

centidegrees per square second

Value

Meaning

0

Disabled

30000

VerySlow

72000

Slow

108000

Medium

162000

Fast

ATC_ACCEL_P_MAX: Acceleration Max for Pitch

Note: This parameter is for advanced users

Maximum acceleration in pitch axis

Increment

Range

Units

Values

1000

0 to 180000

centidegrees per square second

Value

Meaning

0

Disabled

30000

VerySlow

72000

Slow

108000

Medium

162000

Fast

ATC_ANGLE_BOOST: Angle Boost

Note: This parameter is for advanced users

Angle Boost increases output throttle as the vehicle leans to reduce loss of altitude

Values

Value

Meaning

0

Disabled

1

Enabled

ATC_ANG_RLL_P: Roll axis angle controller P gain

Roll axis angle controller P gain. Converts the error between the desired roll angle and actual angle to a desired roll rate

Range

3.000 to 12.000

ATC_ANG_PIT_P: Pitch axis angle controller P gain

Pitch axis angle controller P gain. Converts the error between the desired pitch angle and actual angle to a desired pitch rate

Range

3.000 to 12.000

ATC_ANG_YAW_P: Yaw axis angle controller P gain

Yaw axis angle controller P gain. Converts the error between the desired yaw angle and actual angle to a desired yaw rate

Range

3.000 to 12.000

ATC_ANG_LIM_TC: Angle Limit (to maintain altitude) Time Constant

Note: This parameter is for advanced users

Angle Limit (to maintain altitude) Time Constant

Range

0.5 to 10.0

ATC_RATE_R_MAX: Angular Velocity Max for Roll

Note: This parameter is for advanced users

Maximum angular velocity in roll axis

Increment

Range

Units

Values

1

0 to 1080

degrees per second

Value

Meaning

0

Disabled

60

Slow

180

Medium

360

Fast

ATC_RATE_P_MAX: Angular Velocity Max for Pitch

Note: This parameter is for advanced users

Maximum angular velocity in pitch axis

Increment

Range

Units

Values

1

0 to 1080

degrees per second

Value

Meaning

0

Disabled

60

Slow

180

Medium

360

Fast

ATC_RATE_Y_MAX: Angular Velocity Max for Yaw

Note: This parameter is for advanced users

Maximum angular velocity in yaw axis

Increment

Range

Units

Values

1

0 to 1080

degrees per second

Value

Meaning

0

Disabled

60

Slow

180

Medium

360

Fast

ATC_INPUT_TC: Attitude control input time constant

Attitude control input time constant. Low numbers lead to sharper response, higher numbers to softer response

Increment

Range

Units

Values

0.01

0 to 1

seconds

Value

Meaning

0.5

Very Soft

0.2

Soft

0.15

Medium

0.1

Crisp

0.05

Very Crisp

ATC_LAND_R_MULT: Landed roll gain multiplier

Note: This parameter is for advanced users

Roll gain multiplier active when landed. A factor of 1.0 means no reduction in gain while landed. Reduce this factor to reduce ground oscitation in the roll axis.

Range

0.25 to 1.0

ATC_LAND_P_MULT: Landed pitch gain multiplier

Note: This parameter is for advanced users

Pitch gain multiplier active when landed. A factor of 1.0 means no reduction in gain while landed. Reduce this factor to reduce ground oscitation in the pitch axis.

Range

0.25 to 1.0

ATC_LAND_Y_MULT: Landed yaw gain multiplier

Note: This parameter is for advanced users

Yaw gain multiplier active when landed. A factor of 1.0 means no reduction in gain while landed. Reduce this factor to reduce ground oscitation in the yaw axis.

Range

0.25 to 1.0

ATC_RAT_RLL_P (AC_AttitudeControl_Multi): Roll axis rate controller P gain

Roll axis rate controller P gain. Corrects in proportion to the difference between the desired roll rate vs actual roll rate

Increment

Range

0.005

0.01 to 0.5

ATC_RAT_RLL_I (AC_AttitudeControl_Multi): Roll axis rate controller I gain

Roll axis rate controller I gain. Corrects long-term difference in desired roll rate vs actual roll rate

Increment

Range

0.01

0.01 to 2.0

ATC_RAT_RLL_IMAX (AC_AttitudeControl_Multi): Roll axis rate controller I gain maximum

Roll axis rate controller I gain maximum. Constrains the maximum that the I term will output

Increment

Range

0.01

0 to 1

ATC_RAT_RLL_D (AC_AttitudeControl_Multi): Roll axis rate controller D gain

Roll axis rate controller D gain. Compensates for short-term change in desired roll rate vs actual roll rate

Increment

Range

0.001

0.0 to 0.05

ATC_RAT_RLL_FF (AC_AttitudeControl_Multi): Roll axis rate controller feed forward

Roll axis rate controller feed forward

Increment

Range

0.001

0 to 0.5

ATC_RAT_RLL_FLTT (AC_AttitudeControl_Multi): Roll axis rate controller target frequency in Hz

Roll axis rate controller target frequency in Hz

Increment

Range

Units

1

5 to 100

hertz

ATC_RAT_RLL_FLTE (AC_AttitudeControl_Multi): Roll axis rate controller error frequency in Hz

Roll axis rate controller error frequency in Hz

Increment

Range

Units

1

0 to 100

hertz

ATC_RAT_RLL_FLTD (AC_AttitudeControl_Multi): Roll axis rate controller derivative frequency in Hz

Roll axis rate controller derivative frequency in Hz

Increment

Range

Units

1

5 to 100

hertz

ATC_RAT_RLL_SMAX (AC_AttitudeControl_Multi): Roll slew rate limit

Note: This parameter is for advanced users

Sets an upper limit on the slew rate produced by the combined P and D gains. If the amplitude of the control action produced by the rate feedback exceeds this value, then the D+P gain is reduced to respect the limit. This limits the amplitude of high frequency oscillations caused by an excessive gain. The limit should be set to no more than 25% of the actuators maximum slew rate to allow for load effects. Note: The gain will not be reduced to less than 10% of the nominal value. A value of zero will disable this feature.

Increment

Range

0.5

0 to 200

ATC_RAT_RLL_PDMX: Roll axis rate controller PD sum maximum

Roll axis rate controller PD sum maximum. The maximum/minimum value that the sum of the P and D term can output

Increment

Range

0.01

0 to 1

ATC_RAT_RLL_D_FF (AC_AttitudeControl_Multi): Roll Derivative FeedForward Gain

Note: This parameter is for advanced users

FF D Gain which produces an output that is proportional to the rate of change of the target

Increment

Range

0.0001

0 to 0.02

ATC_RAT_RLL_NTF (AC_AttitudeControl_Multi): Roll Target notch filter index

Note: This parameter is for advanced users

Roll Target notch filter index

Range

1 to 8

ATC_RAT_RLL_NEF (AC_AttitudeControl_Multi): Roll Error notch filter index

Note: This parameter is for advanced users

Roll Error notch filter index

Range

1 to 8

ATC_RAT_PIT_P (AC_AttitudeControl_Multi): Pitch axis rate controller P gain

Pitch axis rate controller P gain. Corrects in proportion to the difference between the desired pitch rate vs actual pitch rate output

Increment

Range

0.005

0.01 to 0.50

ATC_RAT_PIT_I (AC_AttitudeControl_Multi): Pitch axis rate controller I gain

Pitch axis rate controller I gain. Corrects long-term difference in desired pitch rate vs actual pitch rate

Increment

Range

0.01

0.01 to 2.0

ATC_RAT_PIT_IMAX (AC_AttitudeControl_Multi): Pitch axis rate controller I gain maximum

Pitch axis rate controller I gain maximum. Constrains the maximum that the I term will output

Increment

Range

0.01

0 to 1

ATC_RAT_PIT_D (AC_AttitudeControl_Multi): Pitch axis rate controller D gain

Pitch axis rate controller D gain. Compensates for short-term change in desired pitch rate vs actual pitch rate

Increment

Range

0.001

0.0 to 0.05

ATC_RAT_PIT_FF (AC_AttitudeControl_Multi): Pitch axis rate controller feed forward

Pitch axis rate controller feed forward

Increment

Range

0.001

0 to 0.5

ATC_RAT_PIT_FLTT (AC_AttitudeControl_Multi): Pitch axis rate controller target frequency in Hz

Pitch axis rate controller target frequency in Hz

Increment

Range

Units

1

5 to 100

hertz

ATC_RAT_PIT_FLTE (AC_AttitudeControl_Multi): Pitch axis rate controller error frequency in Hz

Pitch axis rate controller error frequency in Hz

Increment

Range

Units

1

0 to 100

hertz

ATC_RAT_PIT_FLTD (AC_AttitudeControl_Multi): Pitch axis rate controller derivative frequency in Hz

Pitch axis rate controller derivative frequency in Hz

Increment

Range

Units

1

5 to 100

hertz

ATC_RAT_PIT_SMAX (AC_AttitudeControl_Multi): Pitch slew rate limit

Note: This parameter is for advanced users

Sets an upper limit on the slew rate produced by the combined P and D gains. If the amplitude of the control action produced by the rate feedback exceeds this value, then the D+P gain is reduced to respect the limit. This limits the amplitude of high frequency oscillations caused by an excessive gain. The limit should be set to no more than 25% of the actuators maximum slew rate to allow for load effects. Note: The gain will not be reduced to less than 10% of the nominal value. A value of zero will disable this feature.

Increment

Range

0.5

0 to 200

ATC_RAT_PIT_PDMX: Pitch axis rate controller PD sum maximum

Pitch axis rate controller PD sum maximum. The maximum/minimum value that the sum of the P and D term can output

Increment

Range

0.01

0 to 1

ATC_RAT_PIT_D_FF (AC_AttitudeControl_Multi): Pitch Derivative FeedForward Gain

Note: This parameter is for advanced users

FF D Gain which produces an output that is proportional to the rate of change of the target

Increment

Range

0.0001

0 to 0.02

ATC_RAT_PIT_NTF (AC_AttitudeControl_Multi): Pitch Target notch filter index

Note: This parameter is for advanced users

Pitch Target notch filter index

Range

1 to 8

ATC_RAT_PIT_NEF (AC_AttitudeControl_Multi): Pitch Error notch filter index

Note: This parameter is for advanced users

Pitch Error notch filter index

Range

1 to 8

ATC_RAT_YAW_P (AC_AttitudeControl_Multi): Yaw axis rate controller P gain

Yaw axis rate controller P gain. Corrects in proportion to the difference between the desired yaw rate vs actual yaw rate

Increment

Range

0.005

0.10 to 2.50

ATC_RAT_YAW_I (AC_AttitudeControl_Multi): Yaw axis rate controller I gain

Yaw axis rate controller I gain. Corrects long-term difference in desired yaw rate vs actual yaw rate

Increment

Range

0.01

0.010 to 1.0

ATC_RAT_YAW_IMAX (AC_AttitudeControl_Multi): Yaw axis rate controller I gain maximum

Yaw axis rate controller I gain maximum. Constrains the maximum that the I term will output

Increment

Range

0.01

0 to 1

ATC_RAT_YAW_D (AC_AttitudeControl_Multi): Yaw axis rate controller D gain

Yaw axis rate controller D gain. Compensates for short-term change in desired yaw rate vs actual yaw rate

Increment

Range

0.001

0.000 to 0.02

ATC_RAT_YAW_FF (AC_AttitudeControl_Multi): Yaw axis rate controller feed forward

Yaw axis rate controller feed forward

Increment

Range

0.001

0 to 0.5

ATC_RAT_YAW_FLTT (AC_AttitudeControl_Multi): Yaw axis rate controller target frequency in Hz

Yaw axis rate controller target frequency in Hz

Increment

Range

Units

1

1 to 50

hertz

ATC_RAT_YAW_FLTE (AC_AttitudeControl_Multi): Yaw axis rate controller error frequency in Hz

Yaw axis rate controller error frequency in Hz

Increment

Range

Units

1

0 to 20

hertz

ATC_RAT_YAW_FLTD (AC_AttitudeControl_Multi): Yaw axis rate controller derivative frequency in Hz

Yaw axis rate controller derivative frequency in Hz

Increment

Range

Units

1

5 to 50

hertz

ATC_RAT_YAW_SMAX (AC_AttitudeControl_Multi): Yaw slew rate limit

Note: This parameter is for advanced users

Sets an upper limit on the slew rate produced by the combined P and D gains. If the amplitude of the control action produced by the rate feedback exceeds this value, then the D+P gain is reduced to respect the limit. This limits the amplitude of high frequency oscillations caused by an excessive gain. The limit should be set to no more than 25% of the actuators maximum slew rate to allow for load effects. Note: The gain will not be reduced to less than 10% of the nominal value. A value of zero will disable this feature.

Increment

Range

0.5

0 to 200

ATC_RAT_YAW_PDMX: Yaw axis rate controller PD sum maximum

Yaw axis rate controller PD sum maximum. The maximum/minimum value that the sum of the P and D term can output

Increment

Range

0.01

0 to 1

ATC_RAT_YAW_D_FF (AC_AttitudeControl_Multi): Yaw Derivative FeedForward Gain

Note: This parameter is for advanced users

FF D Gain which produces an output that is proportional to the rate of change of the target

Increment

Range

0.0001

0 to 0.02

ATC_RAT_YAW_NTF (AC_AttitudeControl_Multi): Yaw Target notch filter index

Note: This parameter is for advanced users

Yaw Target notch filter index

Range

Units

1 to 8

hertz

ATC_RAT_YAW_NEF (AC_AttitudeControl_Multi): Yaw Error notch filter index

Note: This parameter is for advanced users

Yaw Error notch filter index

Range

1 to 8

ATC_THR_MIX_MIN: Throttle Mix Minimum

Note: This parameter is for advanced users

Throttle vs attitude control prioritisation used when landing (higher values mean we prioritise attitude control over throttle)

Range

0.1 to 0.25

ATC_THR_MIX_MAX: Throttle Mix Maximum

Note: This parameter is for advanced users

Throttle vs attitude control prioritisation used during active flight (higher values mean we prioritise attitude control over throttle)

Range

0.5 to 0.9

ATC_THR_MIX_MAN: Throttle Mix Manual

Note: This parameter is for advanced users

Throttle vs attitude control prioritisation used during manual flight (higher values mean we prioritise attitude control over throttle)

Range

0.1 to 0.9

ATC_THR_G_BOOST: Throttle-gain boost

Note: This parameter is for advanced users

Throttle-gain boost ratio. A value of 0 means no boosting is applied, a value of 1 means full boosting is applied. Describes the ratio increase that is applied to angle P and PD on pitch and roll.

Range

0 to 1

ATC_HOVR_ROL_TRM: Hover Roll Trim

Note: This parameter is for advanced users

Trim the hover roll angle to counter tail rotor thrust in a hover

Increment

Range

Units

10

0 to 1000

centidegrees

ATC_RAT_RLL_P (AC_AttitudeControl_Heli): Roll axis rate controller P gain

Roll axis rate controller P gain. Corrects in proportion to the difference between the desired roll rate vs actual roll rate

Increment

Range

0.005

0.0 to 0.35

ATC_RAT_RLL_I (AC_AttitudeControl_Heli): Roll axis rate controller I gain

Roll axis rate controller I gain. Corrects long-term difference in desired roll rate vs actual roll rate

Increment

Range

0.01

0.0 to 0.6

ATC_RAT_RLL_IMAX (AC_AttitudeControl_Heli): Roll axis rate controller I gain maximum

Roll axis rate controller I gain maximum. Constrains the maximum that the I term will output

Increment

Range

0.01

0 to 1

ATC_RAT_RLL_ILMI: Roll axis rate controller I-term leak minimum

Note: This parameter is for advanced users

Point below which I-term will not leak down

Range

0 to 1

ATC_RAT_RLL_D (AC_AttitudeControl_Heli): Roll axis rate controller D gain

Roll axis rate controller D gain. Compensates for short-term change in desired roll rate vs actual roll rate

Increment

Range

0.001

0.0 to 0.03

ATC_RAT_RLL_FF (AC_AttitudeControl_Heli): Roll axis rate controller feed forward

Roll axis rate controller feed forward

Increment

Range

0.001

0.05 to 0.5

ATC_RAT_RLL_FLTT (AC_AttitudeControl_Heli): Roll axis rate controller target frequency in Hz

Roll axis rate controller target frequency in Hz

Increment

Range

Units

1

5 to 50

hertz

ATC_RAT_RLL_FLTE (AC_AttitudeControl_Heli): Roll axis rate controller error frequency in Hz

Roll axis rate controller error frequency in Hz

Increment

Range

Units

1

5 to 50

hertz

ATC_RAT_RLL_FLTD (AC_AttitudeControl_Heli): Roll axis rate controller derivative frequency in Hz

Roll axis rate controller derivative frequency in Hz

Increment

Range

Units

1

0 to 50

hertz

ATC_RAT_RLL_SMAX (AC_AttitudeControl_Heli): Roll slew rate limit

Note: This parameter is for advanced users

Sets an upper limit on the slew rate produced by the combined P and D gains. If the amplitude of the control action produced by the rate feedback exceeds this value, then the D+P gain is reduced to respect the limit. This limits the amplitude of high frequency oscillations caused by an excessive gain. The limit should be set to no more than 25% of the actuators maximum slew rate to allow for load effects. Note: The gain will not be reduced to less than 10% of the nominal value. A value of zero will disable this feature.

Increment

Range

0.5

0 to 200

ATC_RAT_RLL_D_FF (AC_AttitudeControl_Heli): Roll Derivative FeedForward Gain

Note: This parameter is for advanced users

FF D Gain which produces an output that is proportional to the rate of change of the target

Increment

Range

0.0001

0 to 0.02

ATC_RAT_RLL_NTF (AC_AttitudeControl_Heli): Roll Target notch filter index

Note: This parameter is for advanced users

Roll Target notch filter index

Range

1 to 8

ATC_RAT_RLL_NEF (AC_AttitudeControl_Heli): Roll Error notch filter index

Note: This parameter is for advanced users

Roll Error notch filter index

Range

1 to 8

ATC_RAT_PIT_P (AC_AttitudeControl_Heli): Pitch axis rate controller P gain

Pitch axis rate controller P gain. Corrects in proportion to the difference between the desired pitch rate vs actual pitch rate

Increment

Range

0.005

0.0 to 0.35

ATC_RAT_PIT_I (AC_AttitudeControl_Heli): Pitch axis rate controller I gain

Pitch axis rate controller I gain. Corrects long-term difference in desired pitch rate vs actual pitch rate

Increment

Range

0.01

0.0 to 0.6

ATC_RAT_PIT_IMAX (AC_AttitudeControl_Heli): Pitch axis rate controller I gain maximum

Pitch axis rate controller I gain maximum. Constrains the maximum that the I term will output

Increment

Range

0.01

0 to 1

ATC_RAT_PIT_ILMI: Pitch axis rate controller I-term leak minimum

Note: This parameter is for advanced users

Point below which I-term will not leak down

Range

0 to 1

ATC_RAT_PIT_D (AC_AttitudeControl_Heli): Pitch axis rate controller D gain

Pitch axis rate controller D gain. Compensates for short-term change in desired pitch rate vs actual pitch rate

Increment

Range

0.001

0.0 to 0.03

ATC_RAT_PIT_FF (AC_AttitudeControl_Heli): Pitch axis rate controller feed forward

Pitch axis rate controller feed forward

Increment

Range

0.001

0.05 to 0.5

ATC_RAT_PIT_FLTT (AC_AttitudeControl_Heli): Pitch axis rate controller target frequency in Hz

Pitch axis rate controller target frequency in Hz

Increment

Range

Units

1

5 to 50

hertz

ATC_RAT_PIT_FLTE (AC_AttitudeControl_Heli): Pitch axis rate controller error frequency in Hz

Pitch axis rate controller error frequency in Hz

Increment

Range

Units

1

5 to 50

hertz

ATC_RAT_PIT_FLTD (AC_AttitudeControl_Heli): Pitch axis rate controller derivative frequency in Hz

Pitch axis rate controller derivative frequency in Hz

Increment

Range

Units

1

0 to 50

hertz

ATC_RAT_PIT_SMAX (AC_AttitudeControl_Heli): Pitch slew rate limit

Note: This parameter is for advanced users

Sets an upper limit on the slew rate produced by the combined P and D gains. If the amplitude of the control action produced by the rate feedback exceeds this value, then the D+P gain is reduced to respect the limit. This limits the amplitude of high frequency oscillations caused by an excessive gain. The limit should be set to no more than 25% of the actuators maximum slew rate to allow for load effects. Note: The gain will not be reduced to less than 10% of the nominal value. A value of zero will disable this feature.

Increment

Range

0.5

0 to 200

ATC_RAT_PIT_D_FF (AC_AttitudeControl_Heli): Pitch Derivative FeedForward Gain

Note: This parameter is for advanced users

FF D Gain which produces an output that is proportional to the rate of change of the target

Increment

Range

0.0001

0 to 0.02

ATC_RAT_PIT_NTF (AC_AttitudeControl_Heli): Pitch Target notch filter index

Note: This parameter is for advanced users

Pitch Target notch filter index

Range

1 to 8

ATC_RAT_PIT_NEF (AC_AttitudeControl_Heli): Pitch Error notch filter index

Note: This parameter is for advanced users

Pitch Error notch filter index

Range

1 to 8

ATC_RAT_YAW_P (AC_AttitudeControl_Heli): Yaw axis rate controller P gain

Yaw axis rate controller P gain. Corrects in proportion to the difference between the desired yaw rate vs actual yaw rate

Increment

Range

0.005

0.180 to 0.60

ATC_RAT_YAW_I (AC_AttitudeControl_Heli): Yaw axis rate controller I gain

Yaw axis rate controller I gain. Corrects long-term difference in desired yaw rate vs actual yaw rate

Increment

Range

0.01

0.01 to 0.2

ATC_RAT_YAW_IMAX (AC_AttitudeControl_Heli): Yaw axis rate controller I gain maximum

Yaw axis rate controller I gain maximum. Constrains the maximum that the I term will output

Increment

Range

0.01

0 to 1

ATC_RAT_YAW_ILMI: Yaw axis rate controller I-term leak minimum

Note: This parameter is for advanced users

Point below which I-term will not leak down

Range

0 to 1

ATC_RAT_YAW_D (AC_AttitudeControl_Heli): Yaw axis rate controller D gain

Yaw axis rate controller D gain. Compensates for short-term change in desired yaw rate vs actual yaw rate

Increment

Range

0.001

0.000 to 0.02

ATC_RAT_YAW_FF (AC_AttitudeControl_Heli): Yaw axis rate controller feed forward

Yaw axis rate controller feed forward

Increment

Range

0.001

0 to 0.5

ATC_RAT_YAW_FLTT (AC_AttitudeControl_Heli): Yaw axis rate controller target frequency in Hz

Yaw axis rate controller target frequency in Hz

Increment

Range

Units

1

5 to 50

hertz

ATC_RAT_YAW_FLTE (AC_AttitudeControl_Heli): Yaw axis rate controller error frequency in Hz

Yaw axis rate controller error frequency in Hz

Increment

Range

Units

1

5 to 50

hertz

ATC_RAT_YAW_FLTD (AC_AttitudeControl_Heli): Yaw axis rate controller derivative frequency in Hz

Yaw axis rate controller derivative frequency in Hz

Increment

Range

Units

1

0 to 50

hertz

ATC_RAT_YAW_SMAX (AC_AttitudeControl_Heli): Yaw slew rate limit

Note: This parameter is for advanced users

Sets an upper limit on the slew rate produced by the combined P and D gains. If the amplitude of the control action produced by the rate feedback exceeds this value, then the D+P gain is reduced to respect the limit. This limits the amplitude of high frequency oscillations caused by an excessive gain. The limit should be set to no more than 25% of the actuators maximum slew rate to allow for load effects. Note: The gain will not be reduced to less than 10% of the nominal value. A value of zero will disable this feature.

Increment

Range

0.5

0 to 200

ATC_RAT_YAW_D_FF (AC_AttitudeControl_Heli): Yaw Derivative FeedForward Gain

Note: This parameter is for advanced users

FF D Gain which produces an output that is proportional to the rate of change of the target

Increment

Range

0.0001

0 to 0.02

ATC_RAT_YAW_NTF (AC_AttitudeControl_Heli): Yaw Target notch filter index

Note: This parameter is for advanced users

Yaw Target notch filter index

Range

Units

1 to 8

hertz

ATC_RAT_YAW_NEF (AC_AttitudeControl_Heli): Yaw Error notch filter index

Note: This parameter is for advanced users

Yaw Error notch filter index

Range

1 to 8

ATC_PIRO_COMP: Piro Comp Enable

Note: This parameter is for advanced users

Pirouette compensation enabled

Values

Value

Meaning

0

Disabled

1

Enabled

AUTOTUNE_ Parameters

AUTOTUNE_AXES (AC_AutoTune_Multi): Autotune axis bitmask

1-byte bitmap of axes to autotune

Bitmask

Bit

Meaning

0

Roll

1

Pitch

2

Yaw

3

YawD

AUTOTUNE_AGGR: Autotune aggressiveness

Autotune aggressiveness. Defines the bounce back used to detect size of the D term.

Range

0.05 to 0.10

AUTOTUNE_MIN_D: AutoTune minimum D

Defines the minimum D gain

Range

0.0001 to 0.005

AUTOTUNE_AXES (AC_AutoTune_Heli): Autotune axis bitmask

1-byte bitmap of axes to autotune

Bitmask

Bit

Meaning

0

Roll

1

Pitch

2

Yaw

AUTOTUNE_SEQ: AutoTune Sequence Bitmask

2-byte bitmask to select what tuning should be performed. Max gain automatically performed if Rate D is selected. Values: 7:All,1:VFF Only,2:Rate D/Rate P Only(incl max gain),4:Angle P Only,8:Max Gain Only,16:Tune Check,3:VFF and Rate D/Rate P(incl max gain),5:VFF and Angle P,6:Rate D/Rate P(incl max gain) and angle P

Bitmask

Bit

Meaning

0

VFF

1

Rate D/Rate P(incl max gain)

2

Angle P

3

Max Gain Only

4

Tune Check

AUTOTUNE_FRQ_MIN: AutoTune minimum sweep frequency

Defines the start frequency for sweeps and dwells

Range

10 to 30

AUTOTUNE_FRQ_MAX: AutoTune maximum sweep frequency

Defines the end frequency for sweeps and dwells

Range

50 to 120

AUTOTUNE_GN_MAX: AutoTune maximum response gain

Defines the response gain (output/input) to tune

Range

1 to 2.5

AUTOTUNE_VELXY_P: AutoTune velocity xy P gain

Velocity xy P gain used to hold position during Max Gain, Rate P, and Rate D frequency sweeps

Range

0 to 1

AUTOTUNE_ACC_MAX: AutoTune maximum allowable angular acceleration

maximum angular acceleration in deg/s/s allowed during autotune maneuvers

Range

1 to 4000

AUTOTUNE_RAT_MAX: Autotune maximum allowable angular rate

maximum angular rate in deg/s allowed during autotune maneuvers

Range

0 to 500

AVD_ Parameters

AVD_ENABLE: Enable Avoidance using ADSB

Note: This parameter is for advanced users

Enable Avoidance using ADSB

Values

Value

Meaning

0

Disabled

1

Enabled

AVD_F_ACTION: Collision Avoidance Behavior

Note: This parameter is for advanced users

Specifies aircraft behaviour when a collision is imminent

Values

Value

Meaning

0

None

1

Report

2

Climb Or Descend

3

Move Horizontally

4

Move Perpendicularly in 3D

5

RTL

6

Hover

AVD_W_ACTION: Collision Avoidance Behavior - Warn

Note: This parameter is for advanced users

Specifies aircraft behaviour when a collision may occur

Values

Value

Meaning

0

None

1

Report

AVD_F_RCVRY: Recovery behaviour after a fail event

Note: This parameter is for advanced users

Determines what the aircraft will do after a fail event is resolved

Values

Value

Meaning

0

Remain in AVOID_ADSB

1

Resume previous flight mode

2

RTL

3

Resume if AUTO else Loiter

AVD_OBS_MAX: Maximum number of obstacles to track

Note: This parameter is for advanced users

Maximum number of obstacles to track

AVD_W_TIME: Time Horizon Warn

Note: This parameter is for advanced users

Aircraft velocity vectors are multiplied by this time to determine closest approach. If this results in an approach closer than W_DIST_XY or W_DIST_Z then W_ACTION is undertaken (assuming F_ACTION is not undertaken)

Units

seconds

AVD_F_TIME: Time Horizon Fail

Note: This parameter is for advanced users

Aircraft velocity vectors are multiplied by this time to determine closest approach. If this results in an approach closer than F_DIST_XY or F_DIST_Z then F_ACTION is undertaken

Units

seconds

AVD_W_DIST_XY: Distance Warn XY

Note: This parameter is for advanced users

Closest allowed projected distance before W_ACTION is undertaken

Units

meters

AVD_F_DIST_XY: Distance Fail XY

Note: This parameter is for advanced users

Closest allowed projected distance before F_ACTION is undertaken

Units

meters

AVD_W_DIST_Z: Distance Warn Z

Note: This parameter is for advanced users

Closest allowed projected distance before BEHAVIOUR_W is undertaken

Units

meters

AVD_F_DIST_Z: Distance Fail Z

Note: This parameter is for advanced users

Closest allowed projected distance before BEHAVIOUR_F is undertaken

Units

meters

AVD_F_ALT_MIN: ADS-B avoidance minimum altitude

Note: This parameter is for advanced users

Minimum AMSL (above mean sea level) altitude for ADS-B avoidance. If the vehicle is below this altitude, no avoidance action will take place. Useful to prevent ADS-B avoidance from activating while below the tree line or around structures. Default of 0 is no minimum.

Units

meters

AVOID_ Parameters

AVOID_ENABLE: Avoidance control enable/disable

Enabled/disable avoidance input sources

Bitmask

Bit

Meaning

0

UseFence

1

UseProximitySensor

2

UseBeaconFence

AVOID_ANGLE_MAX: Avoidance max lean angle in non-GPS flight modes

Max lean angle used to avoid obstacles while in non-GPS modes

Increment

Range

Units

10

0 to 4500

centidegrees

AVOID_DIST_MAX: Avoidance distance maximum in non-GPS flight modes

Distance from object at which obstacle avoidance will begin in non-GPS modes

Range

Units

1 to 30

meters

AVOID_MARGIN: Avoidance distance margin in GPS modes

Vehicle will attempt to stay at least this distance (in meters) from objects while in GPS modes

Range

Units

1 to 10

meters

AVOID_BEHAVE: Avoidance behaviour

Avoidance behaviour (slide or stop)

Values

Value

Meaning

0

Slide

1

Stop

AVOID_BACKUP_SPD: Avoidance maximum horizontal backup speed

Maximum speed that will be used to back away from obstacles horizontally in position control modes (m/s). Set zero to disable horizontal backup.

Range

Units

0 to 2

meters per second

AVOID_ALT_MIN: Avoidance minimum altitude

Minimum altitude above which proximity based avoidance will start working. This requires a valid downward facing rangefinder reading to work. Set zero to disable

Range

Units

0 to 6

meters

AVOID_ACCEL_MAX: Avoidance maximum acceleration

Maximum acceleration with which obstacles will be avoided with. Set zero to disable acceleration limits

Range

Units

0 to 9

meters per square second

AVOID_BACKUP_DZ: Avoidance deadzone between stopping and backing away from obstacle

Distance beyond AVOID_MARGIN parameter, after which vehicle will backaway from obstacles. Increase this parameter if you see vehicle going back and forth in front of obstacle.

Range

Units

0 to 2

meters

AVOID_BACKZ_SPD: Avoidance maximum vertical backup speed

Maximum speed that will be used to back away from obstacles vertically in height control modes (m/s). Set zero to disable vertical backup.

Range

Units

0 to 2

meters per second

BARO Parameters

BARO1_GND_PRESS: Ground Pressure

Note: This parameter is for advanced users

calibrated ground pressure in Pascals

Increment

ReadOnly

Units

Volatile

1

True

pascal

True

BARO_GND_TEMP: ground temperature

Note: This parameter is for advanced users

User provided ambient ground temperature in degrees Celsius. This is used to improve the calculation of the altitude the vehicle is at. This parameter is not persistent and will be reset to 0 every time the vehicle is rebooted. A value of 0 means use the internal measurement ambient temperature.

Increment

Units

Volatile

1

degrees Celsius

True

BARO_ALT_OFFSET: altitude offset

Note: This parameter is for advanced users

altitude offset in meters added to barometric altitude. This is used to allow for automatic adjustment of the base barometric altitude by a ground station equipped with a barometer. The value is added to the barometric altitude read by the aircraft. It is automatically reset to 0 when the barometer is calibrated on each reboot or when a preflight calibration is performed.

Increment

Units

0.1

meters

BARO_PRIMARY: Primary barometer

Note: This parameter is for advanced users

This selects which barometer will be the primary if multiple barometers are found

Values

Value

Meaning

0

FirstBaro

1

2ndBaro

2

3rdBaro

BARO_EXT_BUS: External baro bus

Note: This parameter is for advanced users

This selects the bus number for looking for an I2C barometer. When set to -1 it will probe all external i2c buses based on the BARO_PROBE_EXT parameter.

Values

Value

Meaning

-1

Disabled

0

Bus0

1

Bus1

6

Bus6

BARO2_GND_PRESS: Ground Pressure

Note: This parameter is for advanced users

calibrated ground pressure in Pascals

Increment

ReadOnly

Units

Volatile

1

True

pascal

True

BARO3_GND_PRESS: Absolute Pressure

Note: This parameter is for advanced users

calibrated ground pressure in Pascals

Increment

ReadOnly

Units

Volatile

1

True

pascal

True

BARO_FLTR_RNG: Range in which sample is accepted

This sets the range around the average value that new samples must be within to be accepted. This can help reduce the impact of noise on sensors that are on long I2C cables. The value is a percentage from the average value. A value of zero disables this filter.

Increment

Range

Units

1

0 to 100

percent

BARO_PROBE_EXT: External barometers to probe

Note: This parameter is for advanced users

This sets which types of external i2c barometer to look for. It is a bitmask of barometer types. The I2C buses to probe is based on BARO_EXT_BUS. If BARO_EXT_BUS is -1 then it will probe all external buses, otherwise it will probe just the bus number given in BARO_EXT_BUS.

Bitmask

Bit

Meaning

0

BMP085

1

BMP280

2

MS5611

3

MS5607

4

MS5637

5

FBM320

6

DPS280

7

LPS25H

8

Keller

9

MS5837

10

BMP388

11

SPL06

12

MSP

13

BMP581

BARO1_DEVID: Baro ID

Note: This parameter is for advanced users

Barometer sensor ID, taking into account its type, bus and instance

ReadOnly

True

BARO2_DEVID: Baro ID2

Note: This parameter is for advanced users

Barometer2 sensor ID, taking into account its type, bus and instance

ReadOnly

True

BARO3_DEVID: Baro ID3

Note: This parameter is for advanced users

Barometer3 sensor ID, taking into account its type, bus and instance

ReadOnly

True

BARO_FIELD_ELV: field elevation

Note: This parameter is for advanced users

User provided field elevation in meters. This is used to improve the calculation of the altitude the vehicle is at. This parameter is not persistent and will be reset to 0 every time the vehicle is rebooted. Changes to this parameter will only be used when disarmed. A value of 0 means the EKF origin height is used for takeoff height above sea level.

Increment

Units

Volatile

0.1

meters

True

BARO_ALTERR_MAX: Altitude error maximum

Note: This parameter is for advanced users

This is the maximum acceptable altitude discrepancy between GPS altitude and barometric presssure altitude calculated against a standard atmosphere for arming checks to pass. If you are getting an arming error due to this parameter then you may have a faulty or substituted barometer. A common issue is vendors replacing a MS5611 in a "Pixhawk" with a MS5607. If you have that issue then please see BARO_OPTIONS parameter to force the MS5611 to be treated as a MS5607. This check is disabled if the value is zero.

Increment

Range

Units

1

0 to 5000

meters

BARO_OPTIONS: Barometer options

Note: This parameter is for advanced users

Barometer options

Bitmask

Bit

Meaning

0

Treat MS5611 as MS5607

BARO1_WCF_ Parameters

BARO1_WCF_ENABLE: Wind coefficient enable

Note: This parameter is for advanced users

This enables the use of wind coefficients for barometer compensation

Values

Value

Meaning

0

Disabled

1

Enabled

BARO1_WCF_FWD: Pressure error coefficient in positive X direction (forward)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a positive wind relative velocity along the X body axis. If the baro height estimate rises during forwards flight, then this will be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO1_WCF_BCK: Pressure error coefficient in negative X direction (backwards)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a negative wind relative velocity along the X body axis. If the baro height estimate rises during backwards flight, then this will be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO1_WCF_RGT: Pressure error coefficient in positive Y direction (right)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a positive wind relative velocity along the Y body axis. If the baro height estimate rises during sideways flight to the right, then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO1_WCF_LFT: Pressure error coefficient in negative Y direction (left)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a negative wind relative velocity along the Y body axis. If the baro height estimate rises during sideways flight to the left, then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO1_WCF_UP: Pressure error coefficient in positive Z direction (up)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a positive wind relative velocity along the Z body axis. If the baro height estimate rises above truth height during climbing flight (or forward flight with a high forwards lean angle), then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO1_WCF_DN: Pressure error coefficient in negative Z direction (down)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a negative wind relative velocity along the Z body axis. If the baro height estimate rises above truth height during descending flight (or forward flight with a high backwards lean angle, eg braking manoeuvre), then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO2_WCF_ Parameters

BARO2_WCF_ENABLE: Wind coefficient enable

Note: This parameter is for advanced users

This enables the use of wind coefficients for barometer compensation

Values

Value

Meaning

0

Disabled

1

Enabled

BARO2_WCF_FWD: Pressure error coefficient in positive X direction (forward)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a positive wind relative velocity along the X body axis. If the baro height estimate rises during forwards flight, then this will be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO2_WCF_BCK: Pressure error coefficient in negative X direction (backwards)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a negative wind relative velocity along the X body axis. If the baro height estimate rises during backwards flight, then this will be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO2_WCF_RGT: Pressure error coefficient in positive Y direction (right)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a positive wind relative velocity along the Y body axis. If the baro height estimate rises during sideways flight to the right, then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO2_WCF_LFT: Pressure error coefficient in negative Y direction (left)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a negative wind relative velocity along the Y body axis. If the baro height estimate rises during sideways flight to the left, then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO2_WCF_UP: Pressure error coefficient in positive Z direction (up)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a positive wind relative velocity along the Z body axis. If the baro height estimate rises above truth height during climbing flight (or forward flight with a high forwards lean angle), then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO2_WCF_DN: Pressure error coefficient in negative Z direction (down)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a negative wind relative velocity along the Z body axis. If the baro height estimate rises above truth height during descending flight (or forward flight with a high backwards lean angle, eg braking manoeuvre), then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO3_WCF_ Parameters

BARO3_WCF_ENABLE: Wind coefficient enable

Note: This parameter is for advanced users

This enables the use of wind coefficients for barometer compensation

Values

Value

Meaning

0

Disabled

1

Enabled

BARO3_WCF_FWD: Pressure error coefficient in positive X direction (forward)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a positive wind relative velocity along the X body axis. If the baro height estimate rises during forwards flight, then this will be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO3_WCF_BCK: Pressure error coefficient in negative X direction (backwards)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a negative wind relative velocity along the X body axis. If the baro height estimate rises during backwards flight, then this will be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO3_WCF_RGT: Pressure error coefficient in positive Y direction (right)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a positive wind relative velocity along the Y body axis. If the baro height estimate rises during sideways flight to the right, then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO3_WCF_LFT: Pressure error coefficient in negative Y direction (left)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a negative wind relative velocity along the Y body axis. If the baro height estimate rises during sideways flight to the left, then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO3_WCF_UP: Pressure error coefficient in positive Z direction (up)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a positive wind relative velocity along the Z body axis. If the baro height estimate rises above truth height during climbing flight (or forward flight with a high forwards lean angle), then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BARO3_WCF_DN: Pressure error coefficient in negative Z direction (down)

Note: This parameter is for advanced users

This is the ratio of static pressure error to dynamic pressure generated by a negative wind relative velocity along the Z body axis. If the baro height estimate rises above truth height during descending flight (or forward flight with a high backwards lean angle, eg braking manoeuvre), then this should be a negative number. Multirotors can use this feature only if using EKF3 and if the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters have been tuned.

Increment

Range

0.05

-1.0 to 1.0

BATT2_ Parameters

BATT2_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATT2_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATT2_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATT2_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATT2_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATT2_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT2_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT2_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATT2_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT2_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATT2_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT2_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT2_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATT2_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT2_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATT2_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT2_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT2_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATT2_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATT2_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATT2_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATT2_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATT2_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT2_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATT2_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATT2_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATT2_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATT2_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATT2_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATT2_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT2_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATT2_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATT2_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATT2_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATT2_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATT2_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATT2_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT2_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATT2_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATT2_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATT2_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATT2_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATT2_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT2_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATT2_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATT2_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATT2_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATT3_ Parameters

BATT3_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATT3_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATT3_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATT3_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATT3_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATT3_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT3_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT3_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATT3_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT3_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATT3_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT3_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT3_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATT3_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT3_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATT3_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT3_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT3_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATT3_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATT3_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATT3_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATT3_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATT3_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT3_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATT3_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATT3_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATT3_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATT3_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATT3_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATT3_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT3_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATT3_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATT3_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATT3_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATT3_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATT3_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATT3_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT3_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATT3_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATT3_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATT3_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATT3_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATT3_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT3_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATT3_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATT3_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATT3_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATT4_ Parameters

BATT4_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATT4_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATT4_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATT4_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATT4_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATT4_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT4_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT4_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATT4_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT4_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATT4_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT4_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT4_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATT4_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT4_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATT4_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT4_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT4_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATT4_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATT4_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATT4_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATT4_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATT4_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT4_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATT4_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATT4_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATT4_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATT4_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATT4_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATT4_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT4_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATT4_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATT4_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATT4_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATT4_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATT4_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATT4_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT4_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATT4_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATT4_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATT4_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATT4_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATT4_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT4_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATT4_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATT4_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATT4_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATT5_ Parameters

BATT5_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATT5_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATT5_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATT5_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATT5_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATT5_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT5_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT5_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATT5_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT5_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATT5_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT5_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT5_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATT5_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT5_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATT5_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT5_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT5_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATT5_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATT5_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATT5_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATT5_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATT5_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT5_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATT5_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATT5_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATT5_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATT5_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATT5_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATT5_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT5_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATT5_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATT5_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATT5_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATT5_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATT5_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATT5_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT5_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATT5_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATT5_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATT5_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATT5_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATT5_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT5_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATT5_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATT5_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATT5_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATT6_ Parameters

BATT6_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATT6_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATT6_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATT6_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATT6_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATT6_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT6_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT6_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATT6_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT6_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATT6_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT6_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT6_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATT6_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT6_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATT6_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT6_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT6_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATT6_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATT6_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATT6_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATT6_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATT6_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT6_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATT6_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATT6_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATT6_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATT6_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATT6_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATT6_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT6_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATT6_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATT6_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATT6_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATT6_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATT6_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATT6_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT6_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATT6_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATT6_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATT6_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATT6_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATT6_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT6_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATT6_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATT6_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATT6_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATT7_ Parameters

BATT7_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATT7_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATT7_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATT7_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATT7_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATT7_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT7_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT7_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATT7_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT7_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATT7_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT7_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT7_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATT7_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT7_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATT7_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT7_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT7_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATT7_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATT7_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATT7_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATT7_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATT7_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT7_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATT7_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATT7_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATT7_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATT7_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATT7_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATT7_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT7_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATT7_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATT7_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATT7_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATT7_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATT7_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATT7_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT7_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATT7_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATT7_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATT7_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATT7_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATT7_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT7_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATT7_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATT7_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATT7_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATT8_ Parameters

BATT8_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATT8_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATT8_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATT8_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATT8_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATT8_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT8_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT8_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATT8_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT8_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATT8_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT8_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT8_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATT8_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT8_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATT8_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT8_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT8_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATT8_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATT8_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATT8_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATT8_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATT8_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT8_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATT8_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATT8_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATT8_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATT8_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATT8_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATT8_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT8_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATT8_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATT8_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATT8_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATT8_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATT8_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATT8_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT8_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATT8_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATT8_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATT8_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATT8_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATT8_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT8_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATT8_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATT8_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATT8_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATT9_ Parameters

BATT9_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATT9_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATT9_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATT9_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATT9_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATT9_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT9_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT9_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATT9_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT9_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATT9_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT9_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT9_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATT9_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT9_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATT9_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT9_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT9_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATT9_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATT9_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATT9_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATT9_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATT9_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT9_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATT9_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATT9_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATT9_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATT9_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATT9_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATT9_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT9_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATT9_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATT9_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATT9_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATT9_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATT9_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATT9_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT9_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATT9_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATT9_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATT9_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATT9_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATT9_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT9_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATT9_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATT9_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATT9_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATTA_ Parameters

BATTA_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATTA_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATTA_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATTA_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATTA_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATTA_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTA_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTA_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATTA_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTA_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATTA_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTA_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTA_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATTA_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTA_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATTA_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTA_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTA_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATTA_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATTA_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATTA_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATTA_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATTA_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTA_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATTA_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATTA_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATTA_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATTA_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATTA_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATTA_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTA_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATTA_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATTA_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATTA_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATTA_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATTA_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATTA_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTA_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATTA_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATTA_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATTA_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATTA_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATTA_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTA_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATTA_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATTA_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATTA_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATTB_ Parameters

BATTB_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATTB_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATTB_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATTB_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATTB_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATTB_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTB_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTB_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATTB_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTB_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATTB_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTB_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTB_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATTB_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTB_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATTB_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTB_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTB_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATTB_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATTB_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATTB_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATTB_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATTB_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTB_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATTB_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATTB_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATTB_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATTB_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATTB_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATTB_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTB_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATTB_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATTB_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATTB_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATTB_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATTB_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATTB_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTB_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATTB_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATTB_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATTB_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATTB_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATTB_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTB_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATTB_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATTB_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATTB_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATTC_ Parameters

BATTC_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATTC_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATTC_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATTC_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATTC_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATTC_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTC_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTC_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATTC_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTC_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATTC_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTC_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTC_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATTC_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTC_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATTC_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTC_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTC_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATTC_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATTC_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATTC_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATTC_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATTC_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTC_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATTC_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATTC_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATTC_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATTC_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATTC_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATTC_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTC_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATTC_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATTC_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATTC_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATTC_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATTC_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATTC_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTC_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATTC_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATTC_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATTC_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATTC_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATTC_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTC_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATTC_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATTC_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATTC_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATTD_ Parameters

BATTD_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATTD_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATTD_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATTD_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATTD_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATTD_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTD_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTD_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATTD_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTD_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATTD_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTD_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTD_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATTD_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTD_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATTD_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTD_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTD_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATTD_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATTD_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATTD_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATTD_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATTD_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTD_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATTD_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATTD_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATTD_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATTD_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATTD_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATTD_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTD_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATTD_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATTD_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATTD_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATTD_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATTD_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATTD_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTD_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATTD_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATTD_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATTD_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATTD_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATTD_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTD_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATTD_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATTD_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATTD_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATTE_ Parameters

BATTE_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATTE_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATTE_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATTE_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATTE_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATTE_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTE_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTE_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATTE_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTE_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATTE_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTE_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTE_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATTE_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTE_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATTE_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTE_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTE_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATTE_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATTE_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATTE_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATTE_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATTE_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTE_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATTE_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATTE_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATTE_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATTE_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATTE_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATTE_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTE_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATTE_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATTE_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATTE_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATTE_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATTE_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATTE_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTE_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATTE_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATTE_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATTE_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATTE_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATTE_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTE_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATTE_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATTE_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATTE_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATTF_ Parameters

BATTF_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATTF_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATTF_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATTF_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATTF_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATTF_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTF_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTF_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATTF_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTF_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATTF_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTF_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTF_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATTF_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTF_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATTF_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTF_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTF_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATTF_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATTF_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATTF_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATTF_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATTF_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTF_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATTF_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATTF_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATTF_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATTF_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATTF_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATTF_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTF_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATTF_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATTF_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATTF_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATTF_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATTF_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATTF_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTF_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATTF_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATTF_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATTF_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATTF_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATTF_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTF_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATTF_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATTF_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATTF_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATTG_ Parameters

BATTG_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATTG_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATTG_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATTG_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATTG_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATTG_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTG_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTG_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATTG_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTG_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATTG_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATTG_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATTG_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATTG_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATTG_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATTG_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTG_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATTG_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATTG_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATTG_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATTG_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATTG_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATTG_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTG_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATTG_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATTG_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATTG_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATTG_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATTG_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATTG_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTG_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATTG_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATTG_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATTG_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATTG_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATTG_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATTG_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATTG_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATTG_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATTG_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATTG_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATTG_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATTG_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATTG_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATTG_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATTG_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATTG_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BATT_ Parameters

BATT_MONITOR: Battery monitoring

Note: Reboot required after change

Controls enabling monitoring of the battery's voltage and current

Values

Value

Meaning

0

Disabled

3

Analog Voltage Only

4

Analog Voltage and Current

5

Solo

6

Bebop

7

SMBus-Generic

8

DroneCAN-BatteryInfo

9

ESC

10

Sum Of Selected Monitors

11

FuelFlow

12

FuelLevelPWM

13

SMBUS-SUI3

14

SMBUS-SUI6

15

NeoDesign

16

SMBus-Maxell

17

Generator-Elec

18

Generator-Fuel

19

Rotoye

20

MPPT

21

INA2XX

22

LTC2946

23

Torqeedo

24

FuelLevelAnalog

25

Synthetic Current and Analog Voltage

26

INA239_SPI

27

EFI

28

AD7091R5

29

Scripting

BATT_CAPACITY: Battery capacity

Capacity of the battery in mAh when full

Increment

Units

50

milliampere hour

BATT_SERIAL_NUM: Battery serial number

Note: This parameter is for advanced users

Battery serial number, automatically filled in for SMBus batteries, otherwise will be -1. With DroneCan it is the battery_id.

BATT_LOW_TIMER: Low voltage timeout

Note: This parameter is for advanced users

This is the timeout in seconds before a low voltage event will be triggered. For aircraft with low C batteries it may be necessary to raise this in order to cope with low voltage on long takeoffs. A value of zero disables low voltage errors.

Increment

Range

Units

1

0 to 120

seconds

BATT_FS_VOLTSRC: Failsafe voltage source

Note: This parameter is for advanced users

Voltage type used for detection of low voltage event

Values

Value

Meaning

0

Raw Voltage

1

Sag Compensated Voltage

BATT_LOW_VOLT: Low battery voltage

Battery voltage that triggers a low battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT_FS_LOW_ACT parameter.

Increment

Units

0.1

volt

BATT_LOW_MAH: Low battery capacity

Battery capacity at which the low battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT_FS_LOW_ACT parameter.

Increment

Units

50

milliampere hour

BATT_CRT_VOLT: Critical battery voltage

Battery voltage that triggers a critical battery failsafe. Set to 0 to disable. If the battery voltage drops below this voltage continuously for more then the period specified by the BATT_LOW_TIMER parameter then the vehicle will perform the failsafe specified by the BATT_FS_CRT_ACT parameter.

Increment

Units

0.1

volt

BATT_CRT_MAH: Battery critical capacity

Battery capacity at which the critical battery failsafe is triggered. Set to 0 to disable battery remaining failsafe. If the battery capacity drops below this level the vehicle will perform the failsafe specified by the BATT_FS_CRT_ACT parameter.

Increment

Units

50

milliampere hour

BATT_FS_LOW_ACT: Low battery failsafe action

What action the vehicle should perform if it hits a low battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT_FS_CRT_ACT: Critical battery failsafe action

What action the vehicle should perform if it hits a critical battery failsafe

Values

Value

Meaning

0

None

1

Land

2

RTL

3

SmartRTL or RTL

4

SmartRTL or Land

5

Terminate

6

Auto DO_LAND_START or RTL

BATT_ARM_VOLT: Required arming voltage

Note: This parameter is for advanced users

Battery voltage level which is required to arm the aircraft. Set to 0 to allow arming at any voltage.

Increment

Units

0.1

volt

BATT_ARM_MAH: Required arming remaining capacity

Note: This parameter is for advanced users

Battery capacity remaining which is required to arm the aircraft. Set to 0 to allow arming at any capacity. Note that execept for smart batteries rebooting the vehicle will always reset the remaining capacity estimate, which can lead to this check not providing sufficent protection, it is recommended to always use this in conjunction with the BATT_ARM_VOLT parameter.

Increment

Units

50

milliampere hour

BATT_OPTIONS: Battery monitor options

Note: This parameter is for advanced users

This sets options to change the behaviour of the battery monitor

Bitmask

Bit

Meaning

0

Ignore DroneCAN SoC

1

MPPT reports input voltage and current

2

MPPT Powered off when disarmed

3

MPPT Powered on when armed

4

MPPT Powered off at boot

5

MPPT Powered on at boot

6

Send resistance compensated voltage to GCS

7

Allow DroneCAN InfoAux to be from a different CAN node

9

Sum monitor measures minimum voltage instead of average

BATT_ESC_INDEX: ESC Telemetry Index to write to

Note: This parameter is for advanced users

ESC Telemetry Index to write voltage, current, consumption and temperature data to. Use 0 to disable.

Increment

Range

1

0 to 10

BATT_VOLT_PIN: Battery Voltage sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for voltage monitoring.

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT_CURR_PIN: Battery Current sensing pin

Note: Reboot required after change

Sets the analog input pin that should be used for current monitoring.

Values

Value

Meaning

-1

Disabled

3

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

4

CubeOrange_PM2/Navigator

14

Pixhawk2_PM2

15

CubeOrange

17

Durandal

101

PX4-v1

BATT_VOLT_MULT: Voltage Multiplier

Note: This parameter is for advanced users

Used to convert the voltage of the voltage sensing pin (BATT_VOLT_PIN) to the actual battery's voltage (pin_voltage * VOLT_MULT). For the 3DR Power brick with a Pixhawk, this should be set to 10.1. For the Pixhawk with the 3DR 4in1 ESC this should be 12.02. For the PX using the PX4IO power supply this should be set to 1.

BATT_AMP_PERVLT: Amps per volt

Number of amps that a 1V reading on the current sensor corresponds to. With a Pixhawk using the 3DR Power brick this should be set to 17. For the Pixhawk with the 3DR 4in1 ESC this should be 17. For Synthetic Current sensor monitors, this is the maximum, full throttle current draw.

Units

ampere per volt

BATT_AMP_OFFSET: AMP offset

Voltage offset at zero current on current sensor for Analog Sensors. For Synthetic Current sensor, this offset is the zero throttle system current and is added to the calculated throttle base current.

Units

volt

BATT_VLT_OFFSET: Voltage offset

Note: This parameter is for advanced users

Voltage offset on voltage pin. This allows for an offset due to a diode. This voltage is subtracted before the scaling is applied.

Units

volt

BATT_I2C_BUS (AP_BattMonitor_SMBus): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT_I2C_ADDR (AP_BattMonitor_SMBus): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address

Range

0 to 127

BATT_SUM_MASK: Battery Sum mask

0: sum of remaining battery monitors, If none 0 sum of specified monitors. Current will be summed and voltages averaged.

Bitmask

Bit

Meaning

0

monitor 1

1

monitor 2

2

monitor 3

3

monitor 4

4

monitor 5

5

monitor 6

6

monitor 7

7

monitor 8

8

monitor 9

BATT_CURR_MULT: Scales reported power monitor current

Note: This parameter is for advanced users

Multiplier applied to all current related reports to allow for adjustment if no UAVCAN param access or current splitting applications

Range

.1 to 10

BATT_FL_VLT_MIN: Empty fuel level voltage

Note: This parameter is for advanced users

The voltage seen on the analog pin when the fuel tank is empty. Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

Units

0.01 to 10

volt

BATT_FL_V_MULT: Fuel level voltage multiplier

Note: This parameter is for advanced users

Voltage multiplier to determine what the full tank voltage reading is. This is calculated as 1 / (Voltage_Full - Voltage_Empty) Note: For this type of battery monitor, the voltage seen by the analog pin is displayed as battery voltage on a GCS.

Range

0.01 to 10

BATT_FL_FLTR: Fuel level filter frequency

Note: This parameter is for advanced users
Note: Reboot required after change

Filter frequency in Hertz where a low pass filter is used. This is used to filter out tank slosh from the fuel level reading. A value of -1 disables the filter and unfiltered voltage is used to determine the fuel level. The suggested values at in the range of 0.2 Hz to 0.5 Hz.

Range

Units

-1 to 1

hertz

BATT_FL_PIN: Fuel level analog pin number

Analog input pin that fuel level sensor is connected to.Analog Airspeed or RSSI ports can be used for Analog input( some autopilots provide others also). Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

BATT_FL_FF: First order term

Note: This parameter is for advanced users

First order polynomial fit term

Range

-10 to 10

BATT_FL_FS: Second order term

Note: This parameter is for advanced users

Second order polynomial fit term

Range

-10 to 10

BATT_FL_FT: Third order term

Note: This parameter is for advanced users

Third order polynomial fit term

Range

-10 to 10

BATT_FL_OFF: Offset term

Note: This parameter is for advanced users

Offset polynomial fit term

Range

-10 to 10

BATT_MAX_VOLT: Maximum Battery Voltage

Note: This parameter is for advanced users

Maximum voltage of battery. Provides scaling of current versus voltage

Range

7 to 100

BATT_I2C_BUS (AP_BattMonitor_INA2xx): Battery monitor I2C bus number

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C bus number

Range

0 to 3

BATT_I2C_ADDR (AP_BattMonitor_INA2xx): Battery monitor I2C address

Note: This parameter is for advanced users
Note: Reboot required after change

Battery monitor I2C address. If this is zero then probe list of supported addresses

Range

0 to 127

BATT_MAX_AMPS: Battery monitor max current

Note: This parameter is for advanced users

This controls the maximum current the INS2XX sensor will work with.

Range

Units

1 to 400

ampere

BATT_SHUNT: Battery monitor shunt resistor

Note: This parameter is for advanced users

This sets the shunt resistor used in the device

Range

Units

0.0001 to 0.01

Ohm

BATT_ESC_MASK: ESC mask

If 0 all connected ESCs will be used. If non-zero, only those selected in will be used.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

BCN Parameters

BCN_TYPE: Beacon based position estimation device type

Note: This parameter is for advanced users

What type of beacon based position estimation device is connected

Values

Value

Meaning

0

None

1

Pozyx

2

Marvelmind

3

Nooploop

10

SITL

BCN_LATITUDE: Beacon origin's latitude

Note: This parameter is for advanced users

Beacon origin's latitude

Increment

Range

Units

0.000001

-90 to 90

degrees

BCN_LONGITUDE: Beacon origin's longitude

Note: This parameter is for advanced users

Beacon origin's longitude

Increment

Range

Units

0.000001

-180 to 180

degrees

BCN_ALT: Beacon origin's altitude above sealevel in meters

Note: This parameter is for advanced users

Beacon origin's altitude above sealevel in meters

Increment

Range

Units

1

0 to 10000

meters

BCN_ORIENT_YAW: Beacon systems rotation from north in degrees

Note: This parameter is for advanced users

Beacon systems rotation from north in degrees

Increment

Range

Units

1

-180 to +180

degrees

BRD_ Parameters

BRD_SER1_RTSCTS: Serial 1 flow control

Note: This parameter is for advanced users
Note: Reboot required after change

Enable flow control on serial 1 (telemetry 1). You must have the RTS and CTS pins connected to your radio. The standard DF13 6 pin connector for a 3DR radio does have those pins connected. If this is set to 2 then flow control will be auto-detected by checking for the output buffer filling on startup. Note that the PX4v1 does not have hardware flow control pins on this port, so you should leave this disabled.

Values

Value

Meaning

0

Disabled

1

Enabled

2

Auto

3

RS-485 Driver enable RTS pin

BRD_SER2_RTSCTS: Serial 2 flow control

Note: This parameter is for advanced users
Note: Reboot required after change

Enable flow control on serial 2 (telemetry 2). You must have the RTS and CTS pins connected to your radio. The standard DF13 6 pin connector for a 3DR radio does have those pins connected. If this is set to 2 then flow control will be auto-detected by checking for the output buffer filling on startup.

Values

Value

Meaning

0

Disabled

1

Enabled

2

Auto

3

RS-485 Driver enable RTS pin

BRD_SER3_RTSCTS: Serial 3 flow control

Note: This parameter is for advanced users
Note: Reboot required after change

Enable flow control on serial 3. You must have the RTS and CTS pins connected to your radio. The standard DF13 6 pin connector for a 3DR radio does have those pins connected. If this is set to 2 then flow control will be auto-detected by checking for the output buffer filling on startup.

Values

Value

Meaning

0

Disabled

1

Enabled

2

Auto

3

RS-485 Driver enable RTS pin

BRD_SER4_RTSCTS: Serial 4 flow control

Note: This parameter is for advanced users
Note: Reboot required after change

Enable flow control on serial 4. You must have the RTS and CTS pins connected to your radio. The standard DF13 6 pin connector for a 3DR radio does have those pins connected. If this is set to 2 then flow control will be auto-detected by checking for the output buffer filling on startup.

Values

Value

Meaning

0

Disabled

1

Enabled

2

Auto

3

RS-485 Driver enable RTS pin

BRD_SER5_RTSCTS: Serial 5 flow control

Note: This parameter is for advanced users
Note: Reboot required after change

Enable flow control on serial 5. You must have the RTS and CTS pins connected to your radio. The standard DF13 6 pin connector for a 3DR radio does have those pins connected. If this is set to 2 then flow control will be auto-detected by checking for the output buffer filling on startup.

Values

Value

Meaning

0

Disabled

1

Enabled

2

Auto

3

RS-485 Driver enable RTS pin

BRD_SAFETY_DEFLT: Sets default state of the safety switch

Note: Reboot required after change

This controls the default state of the safety switch at startup. When set to 1 the safety switch will start in the safe state (flashing) at boot. When set to zero the safety switch will start in the unsafe state (solid) at startup. Note that if a safety switch is fitted the user can still control the safety state after startup using the switch. The safety state can also be controlled in software using a MAVLink message.

Values

Value

Meaning

0

Disabled

1

Enabled

BRD_SBUS_OUT: SBUS output rate

Note: This parameter is for advanced users
Note: Reboot required after change

This sets the SBUS output frame rate in Hz

Values

Value

Meaning

0

Disabled

1

50Hz

2

75Hz

3

100Hz

4

150Hz

5

200Hz

6

250Hz

7

300Hz

BRD_SERIAL_NUM: User-defined serial number

User-defined serial number of this vehicle, it can be any arbitrary number you want and has no effect on the autopilot

Range

-8388608 to 8388607

BRD_SAFETY_MASK: Outputs which ignore the safety switch state

Note: This parameter is for advanced users
Note: Reboot required after change

A bitmask which controls what outputs can move while the safety switch has not been pressed

Bitmask

Bit

Meaning

0

Output1

1

Output2

2

Output3

3

Output4

4

Output5

5

Output6

6

Output7

7

Output8

8

Output9

9

Output10

10

Output11

11

Output12

12

Output13

13

Output14

BRD_HEAT_TARG: Board heater temperature target

Note: This parameter is for advanced users

Board heater target temperature for boards with controllable heating units. Set to -1 to disable the heater, please reboot after setting to -1.

Range

Units

-1 to 80

degrees Celsius

BRD_TYPE: Board type

Note: This parameter is for advanced users
Note: Reboot required after change

This allows selection of a PX4 or VRBRAIN board type. If set to zero then the board type is auto-detected (PX4)

Values

Value

Meaning

0

AUTO

1

PX4V1

2

Pixhawk

3

Cube/Pixhawk2

4

Pixracer

5

PixhawkMini

6

Pixhawk2Slim

13

Intel Aero FC

14

Pixhawk Pro

20

AUAV2.1

21

PCNC1

22

MINDPXV2

23

SP01

24

CUAVv5/FMUV5

30

VRX BRAIN51

32

VRX BRAIN52

33

VRX BRAIN52E

34

VRX UBRAIN51

35

VRX UBRAIN52

36

VRX CORE10

38

VRX BRAIN54

39

PX4 FMUV6

100

PX4 OLDDRIVERS

BRD_IO_ENABLE: Enable IO co-processor

Note: This parameter is for advanced users
Note: Reboot required after change

This allows for the IO co-processor on boards with an IOMCU to be disabled. Setting to 2 will enable the IOMCU but not attempt to update firmware on startup

Values

Value

Meaning

0

Disabled

1

Enabled

2

EnableNoFWUpdate

BRD_SAFETYOPTION: Options for safety button behavior

This controls the activation of the safety button. It allows you to control if the safety button can be used for safety enable and/or disable, and whether the button is only active when disarmed

Bitmask

Bit

Meaning

0

ActiveForSafetyDisable

1

ActiveForSafetyEnable

2

ActiveWhenArmed

3

Force safety on when the aircraft disarms

BRD_VBUS_MIN: Autopilot board voltage requirement

Note: This parameter is for advanced users

Minimum voltage on the autopilot power rail to allow the aircraft to arm. 0 to disable the check.

Increment

Range

Units

0.1

4.0 to 5.5

volt

BRD_VSERVO_MIN: Servo voltage requirement

Note: This parameter is for advanced users

Minimum voltage on the servo rail to allow the aircraft to arm. 0 to disable the check.

Increment

Range

Units

0.1

3.3 to 12.0

volt

BRD_SD_SLOWDOWN: microSD slowdown

Note: This parameter is for advanced users

This is a scaling factor to slow down microSD operation. It can be used on flight board and microSD card combinations where full speed is not reliable. For normal full speed operation a value of 0 should be used.

Increment

Range

1

0 to 32

BRD_PWM_VOLT_SEL: Set PWM Out Voltage

Note: This parameter is for advanced users

This sets the voltage max for PWM output pulses. 0 for 3.3V and 1 for 5V output. On boards with an IOMCU that support this parameter this option only affects the 8 main outputs, not the 6 auxiliary outputs. Using 5V output can help to reduce the impact of ESC noise interference corrupting signals to the ESCs.

Values

Value

Meaning

0

3.3V

1

5V

BRD_OPTIONS: Board options

Note: This parameter is for advanced users

Board specific option flags

Bitmask

Bit

Meaning

0

Enable hardware watchdog

1

Disable MAVftp

2

Enable set of internal parameters

3

Enable Debug Pins

4

Unlock flash on reboot

5

Write protect firmware flash on reboot

6

Write protect bootloader flash on reboot

7

Skip board validation

8

Disable board arming gpio output change on arm/disarm

9

Use safety pins as profiled

BRD_BOOT_DELAY: Boot delay

Note: This parameter is for advanced users

This adds a delay in milliseconds to boot to ensure peripherals initialise fully

Range

Units

0 to 10000

milliseconds

BRD_HEAT_P: Board Heater P gain

Note: This parameter is for advanced users

Board Heater P gain

Increment

Range

1

1 to 500

BRD_HEAT_I: Board Heater I gain

Note: This parameter is for advanced users

Board Heater integrator gain

Increment

Range

0.1

0 to 1

BRD_HEAT_IMAX: Board Heater IMAX

Note: This parameter is for advanced users

Board Heater integrator maximum

Increment

Range

1

0 to 100

BRD_ALT_CONFIG: Alternative HW config

Note: This parameter is for advanced users
Note: Reboot required after change

Select an alternative hardware configuration. A value of zero selects the default configuration for this board. Other values are board specific. Please see the documentation for your board for details on any alternative configuration values that may be available.

Increment

Range

1

0 to 10

BRD_HEAT_LOWMGN: Board heater temp lower margin

Note: This parameter is for advanced users

Arming check will fail if temp is lower than this margin below BRD_HEAT_TARG. 0 disables the low temperature check

Range

Units

0 to 20

degrees Celsius

BRD_SD_MISSION: SDCard Mission size

Note: This parameter is for advanced users
Note: Reboot required after change

This sets the amount of storage in kilobytes reserved on the microsd card in mission.stg for waypoint storage. Each waypoint uses 15 bytes.

Range

0 to 64

BRD_SD_FENCE: SDCard Fence size

Note: This parameter is for advanced users
Note: Reboot required after change

This sets the amount of storage in kilobytes reserved on the microsd card in fence.stg for fence storage.

Range

0 to 64

BRD_IO_DSHOT: Load DShot FW on IO

Note: This parameter is for advanced users
Note: Reboot required after change

This loads the DShot firmware on the IO co-processor

Values

Value

Meaning

0

StandardFW

1

DshotFW

BRD_RADIO Parameters

BRD_RADIO_TYPE: Set type of direct attached radio

This enables support for direct attached radio receivers

Values

Value

Meaning

0

None

1

CYRF6936

2

CC2500

3

BK2425

BRD_RADIO_PROT: protocol

Note: This parameter is for advanced users

Select air protocol

Values

Value

Meaning

0

Auto

1

DSM2

2

DSMX

BRD_RADIO_DEBUG: debug level

Note: This parameter is for advanced users

radio debug level

Range

0 to 4

BRD_RADIO_DISCRC: disable receive CRC

Note: This parameter is for advanced users

disable receive CRC (for debug)

Values

Value

Meaning

0

NotDisabled

1

Disabled

BRD_RADIO_SIGCH: RSSI signal strength

Note: This parameter is for advanced users

Channel to show receive RSSI signal strength, or zero for disabled

Range

0 to 16

BRD_RADIO_PPSCH: Packet rate channel

Note: This parameter is for advanced users

Channel to show received packet-per-second rate, or zero for disabled

Range

0 to 16

BRD_RADIO_TELEM: Enable telemetry

Note: This parameter is for advanced users

If this is non-zero then telemetry packets will be sent over DSM

Values

Value

Meaning

0

Disabled

1

Enabled

BRD_RADIO_TXPOW: Telemetry Transmit power

Note: This parameter is for advanced users

Set telemetry transmit power. This is the power level (from 1 to 8) for telemetry packets sent from the RX to the TX

Range

1 to 8

BRD_RADIO_FCCTST: Put radio into FCC test mode

Note: This parameter is for advanced users

If this is enabled then the radio will continuously transmit as required for FCC testing. The transmit channel is set by the value of the parameter. The radio will not work for RC input while this is enabled

Values

Value

Meaning

0

Disabled

1

MinChannel

2

MidChannel

3

MaxChannel

4

MinChannelCW

5

MidChannelCW

6

MaxChannelCW

BRD_RADIO_STKMD: Stick input mode

Note: This parameter is for advanced users

This selects between different stick input modes. The default is mode2, which has throttle on the left stick and pitch on the right stick. You can instead set mode1, which has throttle on the right stick and pitch on the left stick.

Values

Value

Meaning

1

Mode1

2

Mode2

BRD_RADIO_TESTCH: Set radio to factory test channel

Note: This parameter is for advanced users

This sets the radio to a fixed test channel for factory testing. Using a fixed channel avoids the need for binding in factory testing.

Values

Value

Meaning

0

Disabled

1

TestChan1

2

TestChan2

3

TestChan3

4

TestChan4

5

TestChan5

6

TestChan6

7

TestChan7

8

TestChan8

BRD_RADIO_TSIGCH: RSSI value channel for telemetry data on transmitter

Note: This parameter is for advanced users

Channel to show telemetry RSSI value as received by TX

Range

0 to 16

BRD_RADIO_TPPSCH: Telemetry PPS channel

Note: This parameter is for advanced users

Channel to show telemetry packets-per-second value, as received at TX

Range

0 to 16

BRD_RADIO_TXMAX: Transmitter transmit power

Note: This parameter is for advanced users

Set transmitter maximum transmit power (from 1 to 8)

Range

1 to 8

BRD_RADIO_BZOFS: Transmitter buzzer adjustment

Note: This parameter is for advanced users

Set transmitter buzzer note adjustment (adjust frequency up)

Range

0 to 40

BRD_RADIO_ABTIME: Auto-bind time

Note: This parameter is for advanced users

When non-zero this sets the time with no transmitter packets before we start looking for auto-bind packets.

Range

0 to 120

BRD_RADIO_ABLVL: Auto-bind level

Note: This parameter is for advanced users

This sets the minimum RSSI of an auto-bind packet for it to be accepted. This should be set so that auto-bind will only happen at short range to minimise the change of an auto-bind happening accidentially

Range

0 to 31

BRD_RTC Parameters

BRD_RTC_TYPES: Allowed sources of RTC time

Note: This parameter is for advanced users

Specifies which sources of UTC time will be accepted

Bitmask

Bit

Meaning

0

GPS

1

MAVLINK_SYSTEM_TIME

2

HW

BRD_RTC_TZ_MIN: Timezone offset from UTC

Note: This parameter is for advanced users

Adds offset in +- minutes from UTC to calculate local time

Range

-720 to +840

BTN_ Parameters

BTN_ENABLE: Enable button reporting

Note: This parameter is for advanced users

This enables the button checking module. When this is disabled the parameters for setting button inputs are not visible

Values

Value

Meaning

0

Disabled

1

Enabled

BTN_PIN1: First button Pin

Digital pin number for first button input. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

BTN_PIN2: Second button Pin

Digital pin number for second button input. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

BTN_PIN3: Third button Pin

Digital pin number for third button input. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

BTN_PIN4: Fourth button Pin

Digital pin number for fourth button input. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

BTN_REPORT_SEND: Report send time

The duration in seconds that a BUTTON_CHANGE report is repeatedly sent to the GCS regarding a button changing state. Note that the BUTTON_CHANGE message is MAVLink2 only.

Range

0 to 3600

BTN_OPTIONS1: Button Pin 1 Options

Options for Pin 1. PWM input detects PWM above or below 1800/1200us instead of logic level. If PWM is not detected or is less than 800us or above 2200us the button will interpreted as low. Invert changes HIGH state to be logic low voltage on pin, or below 1200us, if PWM input.

Bitmask

Bit

Meaning

0

PWM Input

1

InvertInput

BTN_OPTIONS2: Button Pin 2 Options

Options for Pin 2. PWM input detects PWM above or below 1800/1200us instead of logic level. If PWM is not detected or is less than 800us or above 2200us the button will interpreted as low. Invert changes HIGH state to be logic low voltage on pin, or below 1200us, if PWM input.

Bitmask

Bit

Meaning

0

PWM Input

1

InvertInput

BTN_OPTIONS3: Button Pin 3 Options

Options for Pin 3. PWM input detects PWM above or below 1800/1200us instead of logic level. If PWM is not detected or is less than 800us or above 2200us the button will interpreted as low. Invert changes HIGH state to be logic low voltage on pin, or below 1200us, if PWM input.

Bitmask

Bit

Meaning

0

PWM Input

1

InvertInput

BTN_OPTIONS4: Button Pin 4 Options

Options for Pin 4. PWM input detects PWM above or below 1800/1200us instead of logic level. If PWM is not detected or is less than 800us or above 2200us the button will interpreted as low. Invert changes HIGH state to be logic low voltage on pin, or below 1200us, if PWM input.

Bitmask

Bit

Meaning

0

PWM Input

1

InvertInput

BTN_FUNC1: Button Pin 1 RC Channel function

Auxiliary RC Options function executed on pin change

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

BTN_FUNC2: Button Pin 2 RC Channel function

Auxiliary RC Options function executed on pin change

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

BTN_FUNC3: Button Pin 3 RC Channel function

Auxiliary RC Options function executed on pin change

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

BTN_FUNC4: Button Pin 4 RC Channel function

Auxiliary RC Options function executed on pin change

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

CAM Parameters

CAM_MAX_ROLL: Maximum photo roll angle.

Postpone shooting if roll is greater than limit. (0=Disable, will shoot regardless of roll).

Range

Units

0 to 180

degrees

CAM_AUTO_ONLY: Distance-trigging in AUTO mode only

When enabled, trigging by distance is done in AUTO mode only.

Values

Value

Meaning

0

Always

1

Only when in AUTO

CAM1 Parameters

CAM1_TYPE: Camera shutter (trigger) type

how to trigger the camera to take a picture

Values

Value

Meaning

0

None

1

Servo

2

Relay

3

GoPro in Solo Gimbal

4

Mount (Siyi/Topotek/Viewpro/Xacti)

5

MAVLink

6

MAVLinkCamV2

7

Scripting

CAM1_DURATION: Camera shutter duration held open

Duration in seconds that the camera shutter is held open

Range

Units

0 to 5

seconds

CAM1_SERVO_ON: Camera servo ON PWM value

PWM value in microseconds to move servo to when shutter is activated

Range

Units

1000 to 2000

PWM in microseconds

CAM1_SERVO_OFF: Camera servo OFF PWM value

PWM value in microseconds to move servo to when shutter is deactivated

Range

Units

1000 to 2000

PWM in microseconds

CAM1_TRIGG_DIST: Camera trigger distance

Distance in meters between camera triggers. If this value is non-zero then the camera will trigger whenever the position changes by this number of meters regardless of what mode the APM is in. Note that this parameter can also be set in an auto mission using the DO_SET_CAM_TRIGG_DIST command, allowing you to enable/disable the triggering of the camera during the flight.

Range

Units

0 to 1000

meters

CAM1_RELAY_ON: Camera relay ON value

This sets whether the relay goes high or low when it triggers. Note that you should also set RELAY_DEFAULT appropriately for your camera

Values

Value

Meaning

0

Low

1

High

CAM1_INTRVAL_MIN: Camera minimum time interval between photos

Postpone shooting if previous picture was taken less than this many seconds ago

Range

Units

0 to 10

seconds

CAM1_FEEDBAK_PIN: Camera feedback pin

Note: Reboot required after change

pin number to use for save accurate camera feedback messages. If set to -1 then don't use a pin flag for this, otherwise this is a pin number which if held high after a picture trigger order, will save camera messages when camera really takes a picture. A universal camera hot shoe is needed. The pin should be held high for at least 2 milliseconds for reliable trigger detection. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot. See also the CAMx_FEEDBCK_POL option.

Values

Value

Meaning

-1

Disabled

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

CAM1_FEEDBAK_POL: Camera feedback pin polarity

Polarity for feedback pin. If this is 1 then the feedback pin should go high on trigger. If set to 0 then it should go low

Values

Value

Meaning

0

TriggerLow

1

TriggerHigh

CAM1_OPTIONS: Camera options

Camera options bitmask

Bitmask

Bit

Meaning

0

Recording Starts at arming and stops at disarming

CAM1_MNT_INST: Camera Mount instance

Mount instance camera is associated with. 0 means camera and mount have identical instance numbers e.g. camera1 and mount1

CAM1_HFOV: Camera horizontal field of view

Camera horizontal field of view. 0 if unknown

Range

Units

0 to 360

degrees

CAM1_VFOV: Camera vertical field of view

Camera vertical field of view. 0 if unknown

Range

Units

0 to 180

degrees

CAM2 Parameters

CAM2_TYPE: Camera shutter (trigger) type

how to trigger the camera to take a picture

Values

Value

Meaning

0

None

1

Servo

2

Relay

3

GoPro in Solo Gimbal

4

Mount (Siyi/Topotek/Viewpro/Xacti)

5

MAVLink

6

MAVLinkCamV2

7

Scripting

CAM2_DURATION: Camera shutter duration held open

Duration in seconds that the camera shutter is held open

Range

Units

0 to 5

seconds

CAM2_SERVO_ON: Camera servo ON PWM value

PWM value in microseconds to move servo to when shutter is activated

Range

Units

1000 to 2000

PWM in microseconds

CAM2_SERVO_OFF: Camera servo OFF PWM value

PWM value in microseconds to move servo to when shutter is deactivated

Range

Units

1000 to 2000

PWM in microseconds

CAM2_TRIGG_DIST: Camera trigger distance

Distance in meters between camera triggers. If this value is non-zero then the camera will trigger whenever the position changes by this number of meters regardless of what mode the APM is in. Note that this parameter can also be set in an auto mission using the DO_SET_CAM_TRIGG_DIST command, allowing you to enable/disable the triggering of the camera during the flight.

Range

Units

0 to 1000

meters

CAM2_RELAY_ON: Camera relay ON value

This sets whether the relay goes high or low when it triggers. Note that you should also set RELAY_DEFAULT appropriately for your camera

Values

Value

Meaning

0

Low

1

High

CAM2_INTRVAL_MIN: Camera minimum time interval between photos

Postpone shooting if previous picture was taken less than this many seconds ago

Range

Units

0 to 10

seconds

CAM2_FEEDBAK_PIN: Camera feedback pin

Note: Reboot required after change

pin number to use for save accurate camera feedback messages. If set to -1 then don't use a pin flag for this, otherwise this is a pin number which if held high after a picture trigger order, will save camera messages when camera really takes a picture. A universal camera hot shoe is needed. The pin should be held high for at least 2 milliseconds for reliable trigger detection. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot. See also the CAMx_FEEDBCK_POL option.

Values

Value

Meaning

-1

Disabled

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

CAM2_FEEDBAK_POL: Camera feedback pin polarity

Polarity for feedback pin. If this is 1 then the feedback pin should go high on trigger. If set to 0 then it should go low

Values

Value

Meaning

0

TriggerLow

1

TriggerHigh

CAM2_OPTIONS: Camera options

Camera options bitmask

Bitmask

Bit

Meaning

0

Recording Starts at arming and stops at disarming

CAM2_MNT_INST: Camera Mount instance

Mount instance camera is associated with. 0 means camera and mount have identical instance numbers e.g. camera1 and mount1

CAM2_HFOV: Camera horizontal field of view

Camera horizontal field of view. 0 if unknown

Range

Units

0 to 360

degrees

CAM2_VFOV: Camera vertical field of view

Camera vertical field of view. 0 if unknown

Range

Units

0 to 180

degrees

CAM_RC_ Parameters

CAM_RC_TYPE: RunCam device type

RunCam device type used to determine OSD menu structure and shutter options.

Values

Value

Meaning

0

Disabled

1

RunCam Split Micro/RunCam with UART

2

RunCam Split

3

RunCam Split4 4k

4

RunCam Hybrid/RunCam Thumb Pro

5

Runcam 2 4k

CAM_RC_FEATURES: RunCam features available

Note: This parameter is for advanced users

The available features of the attached RunCam device. If 0 then the RunCam device will be queried for the features it supports, otherwise this setting is used.

Bitmask

Bit

Meaning

0

Power Button

1

WiFi Button

2

Change Mode

3

5-Key OSD

4

Settings Access

5

DisplayPort

6

Start Recording

7

Stop Recording

CAM_RC_BT_DELAY: RunCam boot delay before allowing updates

Note: This parameter is for advanced users

Time it takes for the RunCam to become fully ready in ms. If this is too short then commands can get out of sync.

CAM_RC_BTN_DELAY: RunCam button delay before allowing further button presses

Note: This parameter is for advanced users

Time it takes for the a RunCam button press to be actived in ms. If this is too short then commands can get out of sync.

CAM_RC_MDE_DELAY: RunCam mode delay before allowing further button presses

Note: This parameter is for advanced users

Time it takes for the a RunCam mode button press to be actived in ms. If a mode change first requires a video recording change then double this value is used. If this is too short then commands can get out of sync.

CAM_RC_CONTROL: RunCam control option

Note: This parameter is for advanced users

Specifies the allowed actions required to enter the OSD menu and other option like autorecording

Bitmask

Bit

Meaning

0

Stick yaw right

1

Stick roll right

2

3-position switch

3

2-position switch

4

Autorecording enabled

CAN_ Parameters

CAN_LOGLEVEL: Loglevel

Note: This parameter is for advanced users

Loglevel for recording initialisation and debug information from CAN Interface

Range

Values

0 to 4

Value

Meaning

0

Log None

1

Log Error

2

Log Warning and below

3

Log Info and below

4

Log Everything

CAN_D1_ Parameters

CAN_D1_PROTOCOL: Enable use of specific protocol over virtual driver

Note: This parameter is for advanced users
Note: Reboot required after change

Enabling this option starts selected protocol that will use this virtual driver

Values

Value

Meaning

0

Disabled

1

DroneCAN

4

PiccoloCAN

6

EFI_NWPMU

7

USD1

8

KDECAN

10

Scripting

11

Benewake

12

Scripting2

13

TOFSenseP

14

NanoRadar

CAN_D1_PROTOCOL2: Secondary protocol with 11 bit CAN addressing

Note: This parameter is for advanced users
Note: Reboot required after change

Secondary protocol with 11 bit CAN addressing

Values

Value

Meaning

0

Disabled

7

USD1

10

Scripting

11

Benewake

12

Scripting2

13

TOFSenseP

14

NanoRadar

CAN_D1_PC_ Parameters

CAN_D1_PC_ESC_BM: ESC channels

Note: This parameter is for advanced users

Bitmask defining which ESC (motor) channels are to be transmitted over Piccolo CAN

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

CAN_D1_PC_ESC_RT: ESC output rate

Note: This parameter is for advanced users

Output rate of ESC command messages

Range

Units

1 to 500

hertz

CAN_D1_PC_SRV_BM: Servo channels

Note: This parameter is for advanced users

Bitmask defining which servo channels are to be transmitted over Piccolo CAN

Bitmask

Bit

Meaning

0

Servo 1

1

Servo 2

2

Servo 3

3

Servo 4

4

Servo 5

5

Servo 6

6

Servo 7

7

Servo 8

8

Servo 9

9

Servo 10

10

Servo 11

11

Servo 12

12

Servo 13

13

Servo 14

14

Servo 15

15

Servo 16

CAN_D1_PC_SRV_RT: Servo command output rate

Note: This parameter is for advanced users

Output rate of servo command messages

Range

Units

1 to 500

hertz

CAN_D1_PC_ECU_ID: ECU Node ID

Note: This parameter is for advanced users

Node ID to send ECU throttle messages to. Set to zero to disable ECU throttle messages. Set to 255 to broadcast to all ECUs.

Range

0 to 255

CAN_D1_PC_ECU_RT: ECU command output rate

Note: This parameter is for advanced users

Output rate of ECU command messages

Range

Units

1 to 500

hertz

CAN_D1_UC_ Parameters

CAN_D1_UC_NODE: Own node ID

Note: This parameter is for advanced users

DroneCAN node ID used by the driver itself on this network

Range

1 to 125

CAN_D1_UC_SRV_BM: Output channels to be transmitted as servo over DroneCAN

Bitmask with one set for channel to be transmitted as a servo command over DroneCAN

Bitmask

Bit

Meaning

0

Servo 1

1

Servo 2

2

Servo 3

3

Servo 4

4

Servo 5

5

Servo 6

6

Servo 7

7

Servo 8

8

Servo 9

9

Servo 10

10

Servo 11

11

Servo 12

12

Servo 13

13

Servo 14

14

Servo 15

15

Servo 16

16

Servo 17

17

Servo 18

18

Servo 19

19

Servo 20

20

Servo 21

21

Servo 22

22

Servo 23

23

Servo 24

24

Servo 25

25

Servo 26

26

Servo 27

27

Servo 28

28

Servo 29

29

Servo 30

30

Servo 31

31

Servo 32

CAN_D1_UC_ESC_BM: Output channels to be transmitted as ESC over DroneCAN

Note: This parameter is for advanced users

Bitmask with one set for channel to be transmitted as a ESC command over DroneCAN

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

CAN_D1_UC_SRV_RT: Servo output rate

Note: This parameter is for advanced users

Maximum transmit rate for servo outputs

Range

Units

1 to 200

hertz

CAN_D1_UC_OPTION: DroneCAN options

Note: This parameter is for advanced users

Option flags

Bitmask

Bit

Meaning

0

ClearDNADatabase

1

IgnoreDNANodeConflicts

2

EnableCanfd

3

IgnoreDNANodeUnhealthy

4

SendServoAsPWM

5

SendGNSS

6

UseHimarkServo

7

HobbyWingESC

8

EnableStats

9

EnableFlexDebug

CAN_D1_UC_NTF_RT: Notify State rate

Note: This parameter is for advanced users

Maximum transmit rate for Notify State Message

Range

Units

1 to 200

hertz

CAN_D1_UC_ESC_OF: ESC Output channels offset

Note: This parameter is for advanced users

Offset for ESC numbering in DroneCAN ESC RawCommand messages. This allows for more efficient packing of ESC command messages. If your ESCs are on servo functions 5 to 8 and you set this parameter to 4 then the ESC RawCommand will be sent with the first 4 slots filled. This can be used for more efficient usage of CAN bandwidth

Range

0 to 18

CAN_D1_UC_POOL: CAN pool size

Note: This parameter is for advanced users

Amount of memory in bytes to allocate for the DroneCAN memory pool. More memory is needed for higher CAN bus loads

Range

1024 to 16384

CAN_D1_UC_ESC_RV: Bitmask for output channels for reversible ESCs over DroneCAN.

Note: This parameter is for advanced users

Bitmask with one set for each output channel that uses a reversible ESC over DroneCAN. Reversible ESCs use both positive and negative values in RawCommands, with positive commanding the forward direction and negative commanding the reverse direction.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

CAN_D1_UC_RLY_RT: DroneCAN relay output rate

Note: This parameter is for advanced users

Maximum transmit rate for relay outputs, note that this rate is per message each message does 1 relay, so if with more relays will take longer to update at the same rate, a extra message will be sent when a relay changes state

Range

Units

0 to 200

hertz

CAN_D1_UC_SER_EN: DroneCAN Serial enable

Note: This parameter is for advanced users
Note: Reboot required after change

Enable DroneCAN virtual serial ports

Values

Value

Meaning

0

Disabled

1

Enabled

CAN_D1_UC_S1_NOD: Serial CAN remote node number

Note: This parameter is for advanced users
Note: Reboot required after change

CAN remote node number for serial port

Range

0 to 127

CAN_D1_UC_S1_IDX: DroneCAN Serial1 index

Note: This parameter is for advanced users
Note: Reboot required after change

Serial port number on remote CAN node

Range

Values

0 to 100

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

CAN_D1_UC_S1_BD: DroneCAN Serial default baud rate

Note: This parameter is for advanced users
Note: Reboot required after change

Serial baud rate on remote CAN node

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

CAN_D1_UC_S1_PRO: Serial protocol of DroneCAN serial port

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of DroneCAN serial port

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

CAN_D1_UC_S2_NOD: Serial CAN remote node number

Note: This parameter is for advanced users
Note: Reboot required after change

CAN remote node number for serial port

Range

0 to 127

CAN_D1_UC_S2_IDX: Serial port number on remote CAN node

Note: This parameter is for advanced users
Note: Reboot required after change

Serial port number on remote CAN node

Range

Values

0 to 100

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

CAN_D1_UC_S2_BD: DroneCAN Serial default baud rate

Note: This parameter is for advanced users
Note: Reboot required after change

Serial baud rate on remote CAN node

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

CAN_D1_UC_S2_PRO: Serial protocol of DroneCAN serial port

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of DroneCAN serial port

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

CAN_D1_UC_S3_NOD: Serial CAN remote node number

Note: This parameter is for advanced users
Note: Reboot required after change

CAN node number for serial port

Range

0 to 127

CAN_D1_UC_S3_IDX: Serial port number on remote CAN node

Note: This parameter is for advanced users
Note: Reboot required after change

Serial port number on remote CAN node

Range

Values

0 to 100

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

CAN_D1_UC_S3_BD: Serial baud rate on remote CAN node

Note: This parameter is for advanced users
Note: Reboot required after change

Serial baud rate on remote CAN node

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

CAN_D1_UC_S3_PRO: Serial protocol of DroneCAN serial port

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of DroneCAN serial port

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

CAN_D2_ Parameters

CAN_D2_PROTOCOL: Enable use of specific protocol over virtual driver

Note: This parameter is for advanced users
Note: Reboot required after change

Enabling this option starts selected protocol that will use this virtual driver

Values

Value

Meaning

0

Disabled

1

DroneCAN

4

PiccoloCAN

6

EFI_NWPMU

7

USD1

8

KDECAN

10

Scripting

11

Benewake

12

Scripting2

13

TOFSenseP

14

NanoRadar

CAN_D2_PROTOCOL2: Secondary protocol with 11 bit CAN addressing

Note: This parameter is for advanced users
Note: Reboot required after change

Secondary protocol with 11 bit CAN addressing

Values

Value

Meaning

0

Disabled

7

USD1

10

Scripting

11

Benewake

12

Scripting2

13

TOFSenseP

14

NanoRadar

CAN_D2_PC_ Parameters

CAN_D2_PC_ESC_BM: ESC channels

Note: This parameter is for advanced users

Bitmask defining which ESC (motor) channels are to be transmitted over Piccolo CAN

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

CAN_D2_PC_ESC_RT: ESC output rate

Note: This parameter is for advanced users

Output rate of ESC command messages

Range

Units

1 to 500

hertz

CAN_D2_PC_SRV_BM: Servo channels

Note: This parameter is for advanced users

Bitmask defining which servo channels are to be transmitted over Piccolo CAN

Bitmask

Bit

Meaning

0

Servo 1

1

Servo 2

2

Servo 3

3

Servo 4

4

Servo 5

5

Servo 6

6

Servo 7

7

Servo 8

8

Servo 9

9

Servo 10

10

Servo 11

11

Servo 12

12

Servo 13

13

Servo 14

14

Servo 15

15

Servo 16

CAN_D2_PC_SRV_RT: Servo command output rate

Note: This parameter is for advanced users

Output rate of servo command messages

Range

Units

1 to 500

hertz

CAN_D2_PC_ECU_ID: ECU Node ID

Note: This parameter is for advanced users

Node ID to send ECU throttle messages to. Set to zero to disable ECU throttle messages. Set to 255 to broadcast to all ECUs.

Range

0 to 255

CAN_D2_PC_ECU_RT: ECU command output rate

Note: This parameter is for advanced users

Output rate of ECU command messages

Range

Units

1 to 500

hertz

CAN_D2_UC_ Parameters

CAN_D2_UC_NODE: Own node ID

Note: This parameter is for advanced users

DroneCAN node ID used by the driver itself on this network

Range

1 to 125

CAN_D2_UC_SRV_BM: Output channels to be transmitted as servo over DroneCAN

Bitmask with one set for channel to be transmitted as a servo command over DroneCAN

Bitmask

Bit

Meaning

0

Servo 1

1

Servo 2

2

Servo 3

3

Servo 4

4

Servo 5

5

Servo 6

6

Servo 7

7

Servo 8

8

Servo 9

9

Servo 10

10

Servo 11

11

Servo 12

12

Servo 13

13

Servo 14

14

Servo 15

15

Servo 16

16

Servo 17

17

Servo 18

18

Servo 19

19

Servo 20

20

Servo 21

21

Servo 22

22

Servo 23

23

Servo 24

24

Servo 25

25

Servo 26

26

Servo 27

27

Servo 28

28

Servo 29

29

Servo 30

30

Servo 31

31

Servo 32

CAN_D2_UC_ESC_BM: Output channels to be transmitted as ESC over DroneCAN

Note: This parameter is for advanced users

Bitmask with one set for channel to be transmitted as a ESC command over DroneCAN

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

CAN_D2_UC_SRV_RT: Servo output rate

Note: This parameter is for advanced users

Maximum transmit rate for servo outputs

Range

Units

1 to 200

hertz

CAN_D2_UC_OPTION: DroneCAN options

Note: This parameter is for advanced users

Option flags

Bitmask

Bit

Meaning

0

ClearDNADatabase

1

IgnoreDNANodeConflicts

2

EnableCanfd

3

IgnoreDNANodeUnhealthy

4

SendServoAsPWM

5

SendGNSS

6

UseHimarkServo

7

HobbyWingESC

8

EnableStats

9

EnableFlexDebug

CAN_D2_UC_NTF_RT: Notify State rate

Note: This parameter is for advanced users

Maximum transmit rate for Notify State Message

Range

Units

1 to 200

hertz

CAN_D2_UC_ESC_OF: ESC Output channels offset

Note: This parameter is for advanced users

Offset for ESC numbering in DroneCAN ESC RawCommand messages. This allows for more efficient packing of ESC command messages. If your ESCs are on servo functions 5 to 8 and you set this parameter to 4 then the ESC RawCommand will be sent with the first 4 slots filled. This can be used for more efficient usage of CAN bandwidth

Range

0 to 18

CAN_D2_UC_POOL: CAN pool size

Note: This parameter is for advanced users

Amount of memory in bytes to allocate for the DroneCAN memory pool. More memory is needed for higher CAN bus loads

Range

1024 to 16384

CAN_D2_UC_ESC_RV: Bitmask for output channels for reversible ESCs over DroneCAN.

Note: This parameter is for advanced users

Bitmask with one set for each output channel that uses a reversible ESC over DroneCAN. Reversible ESCs use both positive and negative values in RawCommands, with positive commanding the forward direction and negative commanding the reverse direction.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

CAN_D2_UC_RLY_RT: DroneCAN relay output rate

Note: This parameter is for advanced users

Maximum transmit rate for relay outputs, note that this rate is per message each message does 1 relay, so if with more relays will take longer to update at the same rate, a extra message will be sent when a relay changes state

Range

Units

0 to 200

hertz

CAN_D2_UC_SER_EN: DroneCAN Serial enable

Note: This parameter is for advanced users
Note: Reboot required after change

Enable DroneCAN virtual serial ports

Values

Value

Meaning

0

Disabled

1

Enabled

CAN_D2_UC_S1_NOD: Serial CAN remote node number

Note: This parameter is for advanced users
Note: Reboot required after change

CAN remote node number for serial port

Range

0 to 127

CAN_D2_UC_S1_IDX: DroneCAN Serial1 index

Note: This parameter is for advanced users
Note: Reboot required after change

Serial port number on remote CAN node

Range

Values

0 to 100

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

CAN_D2_UC_S1_BD: DroneCAN Serial default baud rate

Note: This parameter is for advanced users
Note: Reboot required after change

Serial baud rate on remote CAN node

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

CAN_D2_UC_S1_PRO: Serial protocol of DroneCAN serial port

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of DroneCAN serial port

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

CAN_D2_UC_S2_NOD: Serial CAN remote node number

Note: This parameter is for advanced users
Note: Reboot required after change

CAN remote node number for serial port

Range

0 to 127

CAN_D2_UC_S2_IDX: Serial port number on remote CAN node

Note: This parameter is for advanced users
Note: Reboot required after change

Serial port number on remote CAN node

Range

Values

0 to 100

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

CAN_D2_UC_S2_BD: DroneCAN Serial default baud rate

Note: This parameter is for advanced users
Note: Reboot required after change

Serial baud rate on remote CAN node

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

CAN_D2_UC_S2_PRO: Serial protocol of DroneCAN serial port

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of DroneCAN serial port

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

CAN_D2_UC_S3_NOD: Serial CAN remote node number

Note: This parameter is for advanced users
Note: Reboot required after change

CAN node number for serial port

Range

0 to 127

CAN_D2_UC_S3_IDX: Serial port number on remote CAN node

Note: This parameter is for advanced users
Note: Reboot required after change

Serial port number on remote CAN node

Range

Values

0 to 100

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

CAN_D2_UC_S3_BD: Serial baud rate on remote CAN node

Note: This parameter is for advanced users
Note: Reboot required after change

Serial baud rate on remote CAN node

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

CAN_D2_UC_S3_PRO: Serial protocol of DroneCAN serial port

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of DroneCAN serial port

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

CAN_D3_ Parameters

CAN_D3_PROTOCOL: Enable use of specific protocol over virtual driver

Note: This parameter is for advanced users
Note: Reboot required after change

Enabling this option starts selected protocol that will use this virtual driver

Values

Value

Meaning

0

Disabled

1

DroneCAN

4

PiccoloCAN

6

EFI_NWPMU

7

USD1

8

KDECAN

10

Scripting

11

Benewake

12

Scripting2

13

TOFSenseP

14

NanoRadar

CAN_D3_PROTOCOL2: Secondary protocol with 11 bit CAN addressing

Note: This parameter is for advanced users
Note: Reboot required after change

Secondary protocol with 11 bit CAN addressing

Values

Value

Meaning

0

Disabled

7

USD1

10

Scripting

11

Benewake

12

Scripting2

13

TOFSenseP

14

NanoRadar

CAN_D3_PC_ Parameters

CAN_D3_PC_ESC_BM: ESC channels

Note: This parameter is for advanced users

Bitmask defining which ESC (motor) channels are to be transmitted over Piccolo CAN

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

CAN_D3_PC_ESC_RT: ESC output rate

Note: This parameter is for advanced users

Output rate of ESC command messages

Range

Units

1 to 500

hertz

CAN_D3_PC_SRV_BM: Servo channels

Note: This parameter is for advanced users

Bitmask defining which servo channels are to be transmitted over Piccolo CAN

Bitmask

Bit

Meaning

0

Servo 1

1

Servo 2

2

Servo 3

3

Servo 4

4

Servo 5

5

Servo 6

6

Servo 7

7

Servo 8

8

Servo 9

9

Servo 10

10

Servo 11

11

Servo 12

12

Servo 13

13

Servo 14

14

Servo 15

15

Servo 16

CAN_D3_PC_SRV_RT: Servo command output rate

Note: This parameter is for advanced users

Output rate of servo command messages

Range

Units

1 to 500

hertz

CAN_D3_PC_ECU_ID: ECU Node ID

Note: This parameter is for advanced users

Node ID to send ECU throttle messages to. Set to zero to disable ECU throttle messages. Set to 255 to broadcast to all ECUs.

Range

0 to 255

CAN_D3_PC_ECU_RT: ECU command output rate

Note: This parameter is for advanced users

Output rate of ECU command messages

Range

Units

1 to 500

hertz

CAN_D3_UC_ Parameters

CAN_D3_UC_NODE: Own node ID

Note: This parameter is for advanced users

DroneCAN node ID used by the driver itself on this network

Range

1 to 125

CAN_D3_UC_SRV_BM: Output channels to be transmitted as servo over DroneCAN

Bitmask with one set for channel to be transmitted as a servo command over DroneCAN

Bitmask

Bit

Meaning

0

Servo 1

1

Servo 2

2

Servo 3

3

Servo 4

4

Servo 5

5

Servo 6

6

Servo 7

7

Servo 8

8

Servo 9

9

Servo 10

10

Servo 11

11

Servo 12

12

Servo 13

13

Servo 14

14

Servo 15

15

Servo 16

16

Servo 17

17

Servo 18

18

Servo 19

19

Servo 20

20

Servo 21

21

Servo 22

22

Servo 23

23

Servo 24

24

Servo 25

25

Servo 26

26

Servo 27

27

Servo 28

28

Servo 29

29

Servo 30

30

Servo 31

31

Servo 32

CAN_D3_UC_ESC_BM: Output channels to be transmitted as ESC over DroneCAN

Note: This parameter is for advanced users

Bitmask with one set for channel to be transmitted as a ESC command over DroneCAN

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

CAN_D3_UC_SRV_RT: Servo output rate

Note: This parameter is for advanced users

Maximum transmit rate for servo outputs

Range

Units

1 to 200

hertz

CAN_D3_UC_OPTION: DroneCAN options

Note: This parameter is for advanced users

Option flags

Bitmask

Bit

Meaning

0

ClearDNADatabase

1

IgnoreDNANodeConflicts

2

EnableCanfd

3

IgnoreDNANodeUnhealthy

4

SendServoAsPWM

5

SendGNSS

6

UseHimarkServo

7

HobbyWingESC

8

EnableStats

9

EnableFlexDebug

CAN_D3_UC_NTF_RT: Notify State rate

Note: This parameter is for advanced users

Maximum transmit rate for Notify State Message

Range

Units

1 to 200

hertz

CAN_D3_UC_ESC_OF: ESC Output channels offset

Note: This parameter is for advanced users

Offset for ESC numbering in DroneCAN ESC RawCommand messages. This allows for more efficient packing of ESC command messages. If your ESCs are on servo functions 5 to 8 and you set this parameter to 4 then the ESC RawCommand will be sent with the first 4 slots filled. This can be used for more efficient usage of CAN bandwidth

Range

0 to 18

CAN_D3_UC_POOL: CAN pool size

Note: This parameter is for advanced users

Amount of memory in bytes to allocate for the DroneCAN memory pool. More memory is needed for higher CAN bus loads

Range

1024 to 16384

CAN_D3_UC_ESC_RV: Bitmask for output channels for reversible ESCs over DroneCAN.

Note: This parameter is for advanced users

Bitmask with one set for each output channel that uses a reversible ESC over DroneCAN. Reversible ESCs use both positive and negative values in RawCommands, with positive commanding the forward direction and negative commanding the reverse direction.

Bitmask

Bit

Meaning

0

ESC 1

1

ESC 2

2

ESC 3

3

ESC 4

4

ESC 5

5

ESC 6

6

ESC 7

7

ESC 8

8

ESC 9

9

ESC 10

10

ESC 11

11

ESC 12

12

ESC 13

13

ESC 14

14

ESC 15

15

ESC 16

16

ESC 17

17

ESC 18

18

ESC 19

19

ESC 20

20

ESC 21

21

ESC 22

22

ESC 23

23

ESC 24

24

ESC 25

25

ESC 26

26

ESC 27

27

ESC 28

28

ESC 29

29

ESC 30

30

ESC 31

31

ESC 32

CAN_D3_UC_RLY_RT: DroneCAN relay output rate

Note: This parameter is for advanced users

Maximum transmit rate for relay outputs, note that this rate is per message each message does 1 relay, so if with more relays will take longer to update at the same rate, a extra message will be sent when a relay changes state

Range

Units

0 to 200

hertz

CAN_D3_UC_SER_EN: DroneCAN Serial enable

Note: This parameter is for advanced users
Note: Reboot required after change

Enable DroneCAN virtual serial ports

Values

Value

Meaning

0

Disabled

1

Enabled

CAN_D3_UC_S1_NOD: Serial CAN remote node number

Note: This parameter is for advanced users
Note: Reboot required after change

CAN remote node number for serial port

Range

0 to 127

CAN_D3_UC_S1_IDX: DroneCAN Serial1 index

Note: This parameter is for advanced users
Note: Reboot required after change

Serial port number on remote CAN node

Range

Values

0 to 100

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

CAN_D3_UC_S1_BD: DroneCAN Serial default baud rate

Note: This parameter is for advanced users
Note: Reboot required after change

Serial baud rate on remote CAN node

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

CAN_D3_UC_S1_PRO: Serial protocol of DroneCAN serial port

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of DroneCAN serial port

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

CAN_D3_UC_S2_NOD: Serial CAN remote node number

Note: This parameter is for advanced users
Note: Reboot required after change

CAN remote node number for serial port

Range

0 to 127

CAN_D3_UC_S2_IDX: Serial port number on remote CAN node

Note: This parameter is for advanced users
Note: Reboot required after change

Serial port number on remote CAN node

Range

Values

0 to 100

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

CAN_D3_UC_S2_BD: DroneCAN Serial default baud rate

Note: This parameter is for advanced users
Note: Reboot required after change

Serial baud rate on remote CAN node

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

CAN_D3_UC_S2_PRO: Serial protocol of DroneCAN serial port

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of DroneCAN serial port

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

CAN_D3_UC_S3_NOD: Serial CAN remote node number

Note: This parameter is for advanced users
Note: Reboot required after change

CAN node number for serial port

Range

0 to 127

CAN_D3_UC_S3_IDX: Serial port number on remote CAN node

Note: This parameter is for advanced users
Note: Reboot required after change

Serial port number on remote CAN node

Range

Values

0 to 100

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

CAN_D3_UC_S3_BD: Serial baud rate on remote CAN node

Note: This parameter is for advanced users
Note: Reboot required after change

Serial baud rate on remote CAN node

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

CAN_D3_UC_S3_PRO: Serial protocol of DroneCAN serial port

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of DroneCAN serial port

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

CAN_P1_ Parameters

CAN_P1_DRIVER: Index of virtual driver to be used with physical CAN interface

Note: Reboot required after change

Enabling this option enables use of CAN buses.

Values

Value

Meaning

0

Disabled

1

First driver

2

Second driver

3

Third driver

CAN_P1_BITRATE: Bitrate of CAN interface

Note: This parameter is for advanced users

Bit rate can be set up to from 10000 to 1000000

Range

10000 to 1000000

CAN_P1_FDBITRATE: Bitrate of CANFD interface

Note: This parameter is for advanced users

Bit rate can be set up to from 1000000 to 8000000

Values

Value

Meaning

1

1M

2

2M

4

4M

5

5M

8

8M

CAN_P2_ Parameters

CAN_P2_DRIVER: Index of virtual driver to be used with physical CAN interface

Note: Reboot required after change

Enabling this option enables use of CAN buses.

Values

Value

Meaning

0

Disabled

1

First driver

2

Second driver

3

Third driver

CAN_P2_BITRATE: Bitrate of CAN interface

Note: This parameter is for advanced users

Bit rate can be set up to from 10000 to 1000000

Range

10000 to 1000000

CAN_P2_FDBITRATE: Bitrate of CANFD interface

Note: This parameter is for advanced users

Bit rate can be set up to from 1000000 to 8000000

Values

Value

Meaning

1

1M

2

2M

4

4M

5

5M

8

8M

CAN_P3_ Parameters

CAN_P3_DRIVER: Index of virtual driver to be used with physical CAN interface

Note: Reboot required after change

Enabling this option enables use of CAN buses.

Values

Value

Meaning

0

Disabled

1

First driver

2

Second driver

3

Third driver

CAN_P3_BITRATE: Bitrate of CAN interface

Note: This parameter is for advanced users

Bit rate can be set up to from 10000 to 1000000

Range

10000 to 1000000

CAN_P3_FDBITRATE: Bitrate of CANFD interface

Note: This parameter is for advanced users

Bit rate can be set up to from 1000000 to 8000000

Values

Value

Meaning

1

1M

2

2M

4

4M

5

5M

8

8M

CAN_SLCAN_ Parameters

CAN_SLCAN_CPORT: SLCAN Route

Note: Reboot required after change

CAN Interface ID to be routed to SLCAN, 0 means no routing

Values

Value

Meaning

0

Disabled

1

First interface

2

Second interface

CAN_SLCAN_SERNUM: SLCAN Serial Port

Serial Port ID to be used for temporary SLCAN iface, -1 means no temporary serial. This parameter is automatically reset on reboot or on timeout. See CAN_SLCAN_TIMOUT for timeout details

Values

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

CAN_SLCAN_TIMOUT: SLCAN Timeout

Duration of inactivity after which SLCAN is switched back to original driver in seconds.

Range

0 to 127

CAN_SLCAN_SDELAY: SLCAN Start Delay

Duration after which slcan starts after setting SERNUM in seconds.

Range

0 to 127

CC Parameters

CC_TYPE: Custom control type

Note: This parameter is for advanced users
Note: Reboot required after change

Custom control type to be used

Values

Value

Meaning

0

None

1

Empty

2

PID

CC_AXIS_MASK: Custom Controller bitmask

Note: This parameter is for advanced users

Custom Controller bitmask to chose which axis to run

Bitmask

Bit

Meaning

0

Roll

1

Pitch

2

Yaw

CHUTE_ Parameters

CHUTE_ENABLED: Parachute release enabled or disabled

Parachute release enabled or disabled

Values

Value

Meaning

0

Disabled

1

Enabled

CHUTE_TYPE: Parachute release mechanism type (relay or servo)

Parachute release mechanism type (relay number in versions prior to 4.5, or servo). Values 0-3 all are relay. Relay number used for release is set by RELAYx_FUNCTION in 4.5 or later.

Values

Value

Meaning

0

Relay

10

Servo

CHUTE_SERVO_ON: Parachute Servo ON PWM value

Parachute Servo PWM value in microseconds when parachute is released

Increment

Range

Units

1

1000 to 2000

PWM in microseconds

CHUTE_SERVO_OFF: Servo OFF PWM value

Parachute Servo PWM value in microseconds when parachute is not released

Increment

Range

Units

1

1000 to 2000

PWM in microseconds

CHUTE_ALT_MIN: Parachute min altitude in meters above home

Parachute min altitude above home. Parachute will not be released below this altitude. 0 to disable alt check.

Increment

Range

Units

1

0 to 32000

meters

CHUTE_DELAY_MS: Parachute release delay

Delay in millseconds between motor stop and chute release

Increment

Range

Units

1

0 to 5000

milliseconds

CHUTE_CRT_SINK: Critical sink speed rate in m/s to trigger emergency parachute

Release parachute when critical sink rate is reached

Increment

Range

Units

1

0 to 15

meters per second

CHUTE_OPTIONS: Parachute options

Optional behaviour for parachute

Bitmask

Bit

Meaning

0

hold open forever after release

1

skip disarm before parachute release

CIRCLE_ Parameters

CIRCLE_RADIUS: Circle Radius

Defines the radius of the circle the vehicle will fly when in Circle flight mode

Increment

Range

Units

100

0 to 200000

centimeters

CIRCLE_RATE: Circle rate

Circle mode's turn rate in deg/sec. Positive to turn clockwise, negative for counter clockwise. Circle rate must be less than ATC_SLEW_YAW parameter.

Increment

Range

Units

1

-90 to 90

degrees per second

CIRCLE_OPTIONS: Circle options

0:Enable or disable using the pitch/roll stick control circle mode's radius and rate

Bitmask

Bit

Meaning

0

manual control

1

face direction of travel

2

Start at center rather than on perimeter

3

Make Mount ROI the center of the circle

COMPASS_ Parameters

COMPASS_OFS_X: Compass offsets in milligauss on the X axis

Note: This parameter is for advanced users

Offset to be added to the compass x-axis values to compensate for metal in the frame

Calibration

Increment

Range

Units

1

1

-400 to 400

milligauss

COMPASS_OFS_Y: Compass offsets in milligauss on the Y axis

Note: This parameter is for advanced users

Offset to be added to the compass y-axis values to compensate for metal in the frame

Calibration

Increment

Range

Units

1

1

-400 to 400

milligauss

COMPASS_OFS_Z: Compass offsets in milligauss on the Z axis

Note: This parameter is for advanced users

Offset to be added to the compass z-axis values to compensate for metal in the frame

Calibration

Increment

Range

Units

1

1

-400 to 400

milligauss

COMPASS_DEC: Compass declination

An angle to compensate between the true north and magnetic north

Increment

Range

Units

0.01

-3.142 to 3.142

radians

COMPASS_LEARN: Learn compass offsets automatically

Note: This parameter is for advanced users

Enable or disable the automatic learning of compass offsets. You can enable learning either using a compass-only method that is suitable only for fixed wing aircraft or using the offsets learnt by the active EKF state estimator. If this option is enabled then the learnt offsets are saved when you disarm the vehicle. If InFlight learning is enabled then the compass with automatically start learning once a flight starts (must be armed). While InFlight learning is running you cannot use position control modes.

Values

Value

Meaning

0

Disabled

1

Internal-Learning

2

EKF-Learning

3

InFlight-Learning

COMPASS_USE: Use compass for yaw

Note: This parameter is for advanced users

Enable or disable the use of the compass (instead of the GPS) for determining heading

Values

Value

Meaning

0

Disabled

1

Enabled

COMPASS_AUTODEC: Auto Declination

Note: This parameter is for advanced users

Enable or disable the automatic calculation of the declination based on gps location

Values

Value

Meaning

0

Disabled

1

Enabled

COMPASS_MOTCT: Motor interference compensation type

Note: This parameter is for advanced users

Set motor interference compensation type to disabled, throttle or current. Do not change manually.

Calibration

Values

1

Value

Meaning

0

Disabled

1

Use Throttle

2

Use Current

COMPASS_MOT_X: Motor interference compensation for body frame X axis

Note: This parameter is for advanced users

Multiplied by the current throttle and added to the compass's x-axis values to compensate for motor interference (Offset per Amp or at Full Throttle)

Calibration

Increment

Range

Units

1

1

-1000 to 1000

milligauss per ampere

COMPASS_MOT_Y: Motor interference compensation for body frame Y axis

Note: This parameter is for advanced users

Multiplied by the current throttle and added to the compass's y-axis values to compensate for motor interference (Offset per Amp or at Full Throttle)

Calibration

Increment

Range

Units

1

1

-1000 to 1000

milligauss per ampere

COMPASS_MOT_Z: Motor interference compensation for body frame Z axis

Note: This parameter is for advanced users

Multiplied by the current throttle and added to the compass's z-axis values to compensate for motor interference (Offset per Amp or at Full Throttle)

Calibration

Increment

Range

Units

1

1

-1000 to 1000

milligauss per ampere

COMPASS_ORIENT: Compass orientation

Note: This parameter is for advanced users

The orientation of the first external compass relative to the vehicle frame. This value will be ignored unless this compass is set as an external compass. When set correctly in the northern hemisphere, pointing the nose and right side down should increase the MagX and MagY values respectively. Rolling the vehicle upside down should decrease the MagZ value. For southern hemisphere, switch increase and decrease. NOTE: For internal compasses, AHRS_ORIENT is used. The label for each option is specified in the order of rotations for that orientation. Firmware versions 4.2 and prior can use a CUSTOM (100) rotation to set the COMPASS_CUS_ROLL/PIT/YAW angles for Compass orientation. Later versions provide two general custom rotations which can be used, Custom 1 and Custom 2, with CUST_1_ROLL/PIT/YAW or CUST_2_ROLL/PIT/YAW angles.

Values

Value

Meaning

0

None

1

Yaw45

2

Yaw90

3

Yaw135

4

Yaw180

5

Yaw225

6

Yaw270

7

Yaw315

8

Roll180

9

Yaw45Roll180

10

Yaw90Roll180

11

Yaw135Roll180

12

Pitch180

13

Yaw225Roll180

14

Yaw270Roll180

15

Yaw315Roll180

16

Roll90

17

Yaw45Roll90

18

Yaw90Roll90

19

Yaw135Roll90

20

Roll270

21

Yaw45Roll270

22

Yaw90Roll270

23

Yaw135Roll270

24

Pitch90

25

Pitch270

26

Yaw90Pitch180

27

Yaw270Pitch180

28

Pitch90Roll90

29

Pitch90Roll180

30

Pitch90Roll270

31

Pitch180Roll90

32

Pitch180Roll270

33

Pitch270Roll90

34

Pitch270Roll180

35

Pitch270Roll270

36

Yaw90Pitch180Roll90

37

Yaw270Roll90

38

Yaw293Pitch68Roll180

39

Pitch315

40

Pitch315Roll90

42

Roll45

43

Roll315

100

Custom 4.1 and older

101

Custom 1

102

Custom 2

COMPASS_EXTERNAL: Compass is attached via an external cable

Note: This parameter is for advanced users

Configure compass so it is attached externally. This is auto-detected on most boards. Set to 1 if the compass is externally connected. When externally connected the COMPASS_ORIENT option operates independently of the AHRS_ORIENTATION board orientation option. If set to 0 or 1 then auto-detection by bus connection can override the value. If set to 2 then auto-detection will be disabled.

Values

Value

Meaning

0

Internal

1

External

2

ForcedExternal

COMPASS_OFS2_X: Compass2 offsets in milligauss on the X axis

Note: This parameter is for advanced users

Offset to be added to compass2's x-axis values to compensate for metal in the frame

Calibration

Increment

Range

Units

1

1

-400 to 400

milligauss

COMPASS_OFS2_Y: Compass2 offsets in milligauss on the Y axis

Note: This parameter is for advanced users

Offset to be added to compass2's y-axis values to compensate for metal in the frame

Calibration

Increment

Range

Units

1

1

-400 to 400

milligauss

COMPASS_OFS2_Z: Compass2 offsets in milligauss on the Z axis

Note: This parameter is for advanced users

Offset to be added to compass2's z-axis values to compensate for metal in the frame

Calibration

Increment

Range

Units

1

1

-400 to 400

milligauss

COMPASS_MOT2_X: Motor interference compensation to compass2 for body frame X axis

Note: This parameter is for advanced users

Multiplied by the current throttle and added to compass2's x-axis values to compensate for motor interference (Offset per Amp or at Full Throttle)

Calibration

Increment

Range

Units

1

1

-1000 to 1000

milligauss per ampere

COMPASS_MOT2_Y: Motor interference compensation to compass2 for body frame Y axis

Note: This parameter is for advanced users

Multiplied by the current throttle and added to compass2's y-axis values to compensate for motor interference (Offset per Amp or at Full Throttle)

Calibration

Increment

Range

Units

1

1

-1000 to 1000

milligauss per ampere

COMPASS_MOT2_Z: Motor interference compensation to compass2 for body frame Z axis

Note: This parameter is for advanced users

Multiplied by the current throttle and added to compass2's z-axis values to compensate for motor interference (Offset per Amp or at Full Throttle)

Calibration

Increment

Range

Units

1

1

-1000 to 1000

milligauss per ampere

COMPASS_OFS3_X: Compass3 offsets in milligauss on the X axis

Note: This parameter is for advanced users

Offset to be added to compass3's x-axis values to compensate for metal in the frame

Calibration

Increment

Range

Units

1

1

-400 to 400

milligauss

COMPASS_OFS3_Y: Compass3 offsets in milligauss on the Y axis

Note: This parameter is for advanced users

Offset to be added to compass3's y-axis values to compensate for metal in the frame

Calibration

Increment

Range

Units

1

1

-400 to 400

milligauss

COMPASS_OFS3_Z: Compass3 offsets in milligauss on the Z axis

Note: This parameter is for advanced users

Offset to be added to compass3's z-axis values to compensate for metal in the frame

Calibration

Increment

Range

Units

1

1

-400 to 400

milligauss

COMPASS_MOT3_X: Motor interference compensation to compass3 for body frame X axis

Note: This parameter is for advanced users

Multiplied by the current throttle and added to compass3's x-axis values to compensate for motor interference (Offset per Amp or at Full Throttle)

Calibration

Increment

Range

Units

1

1

-1000 to 1000

milligauss per ampere

COMPASS_MOT3_Y: Motor interference compensation to compass3 for body frame Y axis

Note: This parameter is for advanced users

Multiplied by the current throttle and added to compass3's y-axis values to compensate for motor interference (Offset per Amp or at Full Throttle)

Calibration

Increment

Range

Units

1

1

-1000 to 1000

milligauss per ampere

COMPASS_MOT3_Z: Motor interference compensation to compass3 for body frame Z axis

Note: This parameter is for advanced users

Multiplied by the current throttle and added to compass3's z-axis values to compensate for motor interference (Offset per Amp or at Full Throttle)

Calibration

Increment

Range

Units

1

1

-1000 to 1000

milligauss per ampere

COMPASS_DEV_ID: Compass device id

Note: This parameter is for advanced users

Compass device id. Automatically detected, do not set manually

ReadOnly

True

COMPASS_DEV_ID2: Compass2 device id

Note: This parameter is for advanced users

Second compass's device id. Automatically detected, do not set manually

ReadOnly

True

COMPASS_DEV_ID3: Compass3 device id

Note: This parameter is for advanced users

Third compass's device id. Automatically detected, do not set manually

ReadOnly

True

COMPASS_USE2: Compass2 used for yaw

Note: This parameter is for advanced users

Enable or disable the secondary compass for determining heading.

Values

Value

Meaning

0

Disabled

1

Enabled

COMPASS_ORIENT2: Compass2 orientation

Note: This parameter is for advanced users

The orientation of a second external compass relative to the vehicle frame. This value will be ignored unless this compass is set as an external compass. When set correctly in the northern hemisphere, pointing the nose and right side down should increase the MagX and MagY values respectively. Rolling the vehicle upside down should decrease the MagZ value. For southern hemisphere, switch increase and decrease. NOTE: For internal compasses, AHRS_ORIENT is used. The label for each option is specified in the order of rotations for that orientation. Firmware versions 4.2 and prior can use a CUSTOM (100) rotation to set the COMPASS_CUS_ROLL/PIT/YAW angles for Compass orientation. Later versions provide two general custom rotations which can be used, Custom 1 and Custom 2, with CUST_1_ROLL/PIT/YAW or CUST_2_ROLL/PIT/YAW angles.

Values

Value

Meaning

0

None

1

Yaw45

2

Yaw90

3

Yaw135

4

Yaw180

5

Yaw225

6

Yaw270

7

Yaw315

8

Roll180

9

Yaw45Roll180

10

Yaw90Roll180

11

Yaw135Roll180

12

Pitch180

13

Yaw225Roll180

14

Yaw270Roll180

15

Yaw315Roll180

16

Roll90

17

Yaw45Roll90

18

Yaw90Roll90

19

Yaw135Roll90

20

Roll270

21

Yaw45Roll270

22

Yaw90Roll270

23

Yaw135Roll270

24

Pitch90

25

Pitch270

26

Yaw90Pitch180

27

Yaw270Pitch180

28

Pitch90Roll90

29

Pitch90Roll180

30

Pitch90Roll270

31

Pitch180Roll90

32

Pitch180Roll270

33

Pitch270Roll90

34

Pitch270Roll180

35

Pitch270Roll270

36

Yaw90Pitch180Roll90

37

Yaw270Roll90

38

Yaw293Pitch68Roll180

39

Pitch315

40

Pitch315Roll90

42

Roll45

43

Roll315

100

Custom 4.1 and older

101

Custom 1

102

Custom 2

COMPASS_EXTERN2: Compass2 is attached via an external cable

Note: This parameter is for advanced users

Configure second compass so it is attached externally. This is auto-detected on most boards. If set to 0 or 1 then auto-detection by bus connection can override the value. If set to 2 then auto-detection will be disabled.

Values

Value

Meaning

0

Internal

1

External

2

ForcedExternal

COMPASS_USE3: Compass3 used for yaw

Note: This parameter is for advanced users

Enable or disable the tertiary compass for determining heading.

Values

Value

Meaning

0

Disabled

1

Enabled

COMPASS_ORIENT3: Compass3 orientation

Note: This parameter is for advanced users

The orientation of a third external compass relative to the vehicle frame. This value will be ignored unless this compass is set as an external compass. When set correctly in the northern hemisphere, pointing the nose and right side down should increase the MagX and MagY values respectively. Rolling the vehicle upside down should decrease the MagZ value. For southern hemisphere, switch increase and decrease. NOTE: For internal compasses, AHRS_ORIENT is used. The label for each option is specified in the order of rotations for that orientation. Firmware versions 4.2 and prior can use a CUSTOM (100) rotation to set the COMPASS_CUS_ROLL/PIT/YAW angles for Compass orientation. Later versions provide two general custom rotations which can be used, Custom 1 and Custom 2, with CUST_1_ROLL/PIT/YAW or CUST_2_ROLL/PIT/YAW angles.

Values

Value

Meaning

0

None

1

Yaw45

2

Yaw90

3

Yaw135

4

Yaw180

5

Yaw225

6

Yaw270

7

Yaw315

8

Roll180

9

Yaw45Roll180

10

Yaw90Roll180

11

Yaw135Roll180

12

Pitch180

13

Yaw225Roll180

14

Yaw270Roll180

15

Yaw315Roll180

16

Roll90

17

Yaw45Roll90

18

Yaw90Roll90

19

Yaw135Roll90

20

Roll270

21

Yaw45Roll270

22

Yaw90Roll270

23

Yaw135Roll270

24

Pitch90

25

Pitch270

26

Yaw90Pitch180

27

Yaw270Pitch180

28

Pitch90Roll90

29

Pitch90Roll180

30

Pitch90Roll270

31

Pitch180Roll90

32

Pitch180Roll270

33

Pitch270Roll90

34

Pitch270Roll180

35

Pitch270Roll270

36

Yaw90Pitch180Roll90

37

Yaw270Roll90

38

Yaw293Pitch68Roll180

39

Pitch315

40

Pitch315Roll90

42

Roll45

43

Roll315

100

Custom 4.1 and older

101

Custom 1

102

Custom 2

COMPASS_EXTERN3: Compass3 is attached via an external cable

Note: This parameter is for advanced users

Configure third compass so it is attached externally. This is auto-detected on most boards. If set to 0 or 1 then auto-detection by bus connection can override the value. If set to 2 then auto-detection will be disabled.

Values

Value

Meaning

0

Internal

1

External

2

ForcedExternal

COMPASS_DIA_X: Compass soft-iron diagonal X component

Note: This parameter is for advanced users

DIA_X in the compass soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_DIA_Y: Compass soft-iron diagonal Y component

Note: This parameter is for advanced users

DIA_Y in the compass soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_DIA_Z: Compass soft-iron diagonal Z component

Note: This parameter is for advanced users

DIA_Z in the compass soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_ODI_X: Compass soft-iron off-diagonal X component

Note: This parameter is for advanced users

ODI_X in the compass soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_ODI_Y: Compass soft-iron off-diagonal Y component

Note: This parameter is for advanced users

ODI_Y in the compass soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_ODI_Z: Compass soft-iron off-diagonal Z component

Note: This parameter is for advanced users

ODI_Z in the compass soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_DIA2_X: Compass2 soft-iron diagonal X component

Note: This parameter is for advanced users

DIA_X in the compass2 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_DIA2_Y: Compass2 soft-iron diagonal Y component

Note: This parameter is for advanced users

DIA_Y in the compass2 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_DIA2_Z: Compass2 soft-iron diagonal Z component

Note: This parameter is for advanced users

DIA_Z in the compass2 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_ODI2_X: Compass2 soft-iron off-diagonal X component

Note: This parameter is for advanced users

ODI_X in the compass2 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_ODI2_Y: Compass2 soft-iron off-diagonal Y component

Note: This parameter is for advanced users

ODI_Y in the compass2 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_ODI2_Z: Compass2 soft-iron off-diagonal Z component

Note: This parameter is for advanced users

ODI_Z in the compass2 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_DIA3_X: Compass3 soft-iron diagonal X component

Note: This parameter is for advanced users

DIA_X in the compass3 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_DIA3_Y: Compass3 soft-iron diagonal Y component

Note: This parameter is for advanced users

DIA_Y in the compass3 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_DIA3_Z: Compass3 soft-iron diagonal Z component

Note: This parameter is for advanced users

DIA_Z in the compass3 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_ODI3_X: Compass3 soft-iron off-diagonal X component

Note: This parameter is for advanced users

ODI_X in the compass3 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_ODI3_Y: Compass3 soft-iron off-diagonal Y component

Note: This parameter is for advanced users

ODI_Y in the compass3 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_ODI3_Z: Compass3 soft-iron off-diagonal Z component

Note: This parameter is for advanced users

ODI_Z in the compass3 soft-iron calibration matrix: [[DIA_X, ODI_X, ODI_Y], [ODI_X, DIA_Y, ODI_Z], [ODI_Y, ODI_Z, DIA_Z]]

Calibration

1

COMPASS_CAL_FIT: Compass calibration fitness

Note: This parameter is for advanced users

This controls the fitness level required for a successful compass calibration. A lower value makes for a stricter fit (less likely to pass). This is the value used for the primary magnetometer. Other magnetometers get double the value.

Increment

Range

Values

0.1

4 to 32

Value

Meaning

4

Very Strict

8

Strict

16

Default

32

Relaxed

COMPASS_OFFS_MAX: Compass maximum offset

Note: This parameter is for advanced users

This sets the maximum allowed compass offset in calibration and arming checks

Increment

Range

1

500 to 3000

COMPASS_DISBLMSK: Compass disable driver type mask

Note: This parameter is for advanced users

This is a bitmask of driver types to disable. If a driver type is set in this mask then that driver will not try to find a sensor at startup

Bitmask

Bit

Meaning

0

HMC5883

1

LSM303D

2

AK8963

3

BMM150

4

LSM9DS1

5

LIS3MDL

6

AK09916

7

IST8310

8

ICM20948

9

MMC3416

11

DroneCAN

12

QMC5883

14

MAG3110

15

IST8308

16

RM3100

17

MSP

18

ExternalAHRS

19

MMC5XX3

20

QMC5883P

21

BMM350

COMPASS_FLTR_RNG: Range in which sample is accepted

This sets the range around the average value that new samples must be within to be accepted. This can help reduce the impact of noise on sensors that are on long I2C cables. The value is a percentage from the average value. A value of zero disables this filter.

Increment

Range

Units

1

0 to 100

percent

COMPASS_AUTO_ROT: Automatically check orientation

When enabled this will automatically check the orientation of compasses on successful completion of compass calibration. If set to 2 then external compasses will have their orientation automatically corrected.

Values

Value

Meaning

0

Disabled

1

CheckOnly

2

CheckAndFix

3

use same tolerance to auto rotate 45 deg rotations

COMPASS_PRIO1_ID: Compass device id with 1st order priority

Note: This parameter is for advanced users
Note: Reboot required after change

Compass device id with 1st order priority, set automatically if 0. Reboot required after change.

COMPASS_PRIO2_ID: Compass device id with 2nd order priority

Note: This parameter is for advanced users
Note: Reboot required after change

Compass device id with 2nd order priority, set automatically if 0. Reboot required after change.

COMPASS_PRIO3_ID: Compass device id with 3rd order priority

Note: This parameter is for advanced users
Note: Reboot required after change

Compass device id with 3rd order priority, set automatically if 0. Reboot required after change.

COMPASS_ENABLE: Enable Compass

Note: Reboot required after change

Setting this to Enabled(1) will enable the compass. Setting this to Disabled(0) will disable the compass. Note that this is separate from COMPASS_USE. This will enable the low level senor, and will enable logging of magnetometer data. To use the compass for navigation you must also set COMPASS_USE to 1.

Values

Value

Meaning

0

Disabled

1

Enabled

COMPASS_SCALE: Compass1 scale factor

Scaling factor for first compass to compensate for sensor scaling errors. If this is 0 then no scaling is done

Range

0 to 1.3

COMPASS_SCALE2: Compass2 scale factor

Scaling factor for 2nd compass to compensate for sensor scaling errors. If this is 0 then no scaling is done

Range

0 to 1.3

COMPASS_SCALE3: Compass3 scale factor

Scaling factor for 3rd compass to compensate for sensor scaling errors. If this is 0 then no scaling is done

Range

0 to 1.3

COMPASS_OPTIONS: Compass options

Note: This parameter is for advanced users

This sets options to change the behaviour of the compass

Bitmask

Bit

Meaning

0

CalRequireGPS

1

Allow missing DroneCAN compasses to be automaticaly replaced (calibration still required)

COMPASS_DEV_ID4: Compass4 device id

Note: This parameter is for advanced users

Extra 4th compass's device id. Automatically detected, do not set manually

ReadOnly

True

COMPASS_DEV_ID5: Compass5 device id

Note: This parameter is for advanced users

Extra 5th compass's device id. Automatically detected, do not set manually

ReadOnly

True

COMPASS_DEV_ID6: Compass6 device id

Note: This parameter is for advanced users

Extra 6th compass's device id. Automatically detected, do not set manually

ReadOnly

True

COMPASS_DEV_ID7: Compass7 device id

Note: This parameter is for advanced users

Extra 7th compass's device id. Automatically detected, do not set manually

ReadOnly

True

COMPASS_DEV_ID8: Compass8 device id

Note: This parameter is for advanced users

Extra 8th compass's device id. Automatically detected, do not set manually

ReadOnly

True

COMPASS_CUS_ROLL: Custom orientation roll offset

Note: This parameter is for advanced users
Note: Reboot required after change

Compass mounting position roll offset. Positive values = roll right, negative values = roll left. This parameter is only used when COMPASS_ORIENT/2/3 is set to CUSTOM.

Increment

Range

Units

1

-180 to 180

degrees

COMPASS_CUS_PIT: Custom orientation pitch offset

Note: This parameter is for advanced users
Note: Reboot required after change

Compass mounting position pitch offset. Positive values = pitch up, negative values = pitch down. This parameter is only used when COMPASS_ORIENT/2/3 is set to CUSTOM.

Increment

Range

Units

1

-180 to 180

degrees

COMPASS_CUS_YAW: Custom orientation yaw offset

Note: This parameter is for advanced users
Note: Reboot required after change

Compass mounting position yaw offset. Positive values = yaw right, negative values = yaw left. This parameter is only used when COMPASS_ORIENT/2/3 is set to CUSTOM.

Increment

Range

Units

1

-180 to 180

degrees

COMPASS_PMOT Parameters

COMPASS_PMOT_EN: per-motor compass correction enable

Note: This parameter is for advanced users

This enables per-motor compass corrections

Values

Value

Meaning

0

Disabled

1

Enabled

COMPASS_PMOT_EXP: per-motor exponential correction

Note: This parameter is for advanced users

This is the exponential correction for the power output of the motor for per-motor compass correction

Increment

Range

0.01

0 to 2

COMPASS_PMOT1_X: Compass per-motor1 X

Note: This parameter is for advanced users

Compensation for X axis of motor1

COMPASS_PMOT1_Y: Compass per-motor1 Y

Note: This parameter is for advanced users

Compensation for Y axis of motor1

COMPASS_PMOT1_Z: Compass per-motor1 Z

Note: This parameter is for advanced users

Compensation for Z axis of motor1

COMPASS_PMOT2_X: Compass per-motor2 X

Note: This parameter is for advanced users

Compensation for X axis of motor2

COMPASS_PMOT2_Y: Compass per-motor2 Y

Note: This parameter is for advanced users

Compensation for Y axis of motor2

COMPASS_PMOT2_Z: Compass per-motor2 Z

Note: This parameter is for advanced users

Compensation for Z axis of motor2

COMPASS_PMOT3_X: Compass per-motor3 X

Note: This parameter is for advanced users

Compensation for X axis of motor3

COMPASS_PMOT3_Y: Compass per-motor3 Y

Note: This parameter is for advanced users

Compensation for Y axis of motor3

COMPASS_PMOT3_Z: Compass per-motor3 Z

Note: This parameter is for advanced users

Compensation for Z axis of motor3

COMPASS_PMOT4_X: Compass per-motor4 X

Note: This parameter is for advanced users

Compensation for X axis of motor4

COMPASS_PMOT4_Y: Compass per-motor4 Y

Note: This parameter is for advanced users

Compensation for Y axis of motor4

COMPASS_PMOT4_Z: Compass per-motor4 Z

Note: This parameter is for advanced users

Compensation for Z axis of motor4

CUST_ROT Parameters

CUST_ROT_ENABLE: Enable Custom rotations

Note: Reboot required after change

This enables custom rotations

Values

Value

Meaning

0

Disable

1

Enable

CUST_ROT1_ Parameters

CUST_ROT1_ROLL: Custom roll

Note: Reboot required after change

Custom euler roll, euler 321 (yaw, pitch, roll) ordering

Units

degrees

CUST_ROT1_PITCH: Custom pitch

Note: Reboot required after change

Custom euler pitch, euler 321 (yaw, pitch, roll) ordering

Units

degrees

CUST_ROT1_YAW: Custom yaw

Note: Reboot required after change

Custom euler yaw, euler 321 (yaw, pitch, roll) ordering

Units

degrees

CUST_ROT2_ Parameters

CUST_ROT2_ROLL: Custom roll

Note: Reboot required after change

Custom euler roll, euler 321 (yaw, pitch, roll) ordering

Units

degrees

CUST_ROT2_PITCH: Custom pitch

Note: Reboot required after change

Custom euler pitch, euler 321 (yaw, pitch, roll) ordering

Units

degrees

CUST_ROT2_YAW: Custom yaw

Note: Reboot required after change

Custom euler yaw, euler 321 (yaw, pitch, roll) ordering

Units

degrees

DDS Parameters

DDS_ENABLE: DDS enable

Note: This parameter is for advanced users
Note: Reboot required after change

Enable DDS subsystem

Values

Value

Meaning

0

Disabled

1

Enabled

DDS_UDP_PORT: DDS UDP port

Note: Reboot required after change

UDP port number for DDS

Range

1 to 65535

DDS_DOMAIN_ID: DDS DOMAIN ID

Note: Reboot required after change

Set the ROS_DOMAIN_ID

Range

0 to 232

DDS_TIMEOUT_MS: DDS ping timeout

Note: Reboot required after change

The time in milliseconds the DDS client will wait for a response from the XRCE agent before reattempting.

Increment

Range

Units

1

1 to 10000

milliseconds

DDS_MAX_RETRY: DDS ping max attempts

Note: Reboot required after change

The maximum number of times the DDS client will attempt to ping the XRCE agent before exiting.

Increment

Range

1

1 to 100

DDS_IP Parameters

DDS_IP0: IPv4 Address 1st byte

Note: Reboot required after change

IPv4 address. Example: 192.xxx.xxx.xxx

Range

0 to 255

DDS_IP1: IPv4 Address 2nd byte

Note: Reboot required after change

IPv4 address. Example: xxx.168.xxx.xxx

Range

0 to 255

DDS_IP2: IPv4 Address 3rd byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.13.xxx

Range

0 to 255

DDS_IP3: IPv4 Address 4th byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.xxx.14

Range

0 to 255

DID_ Parameters

DID_ENABLE: Enable ODID subsystem

Enable ODID subsystem

Values

Value

Meaning

0

Disabled

1

Enabled

DID_CANDRIVER: DroneCAN driver number

DroneCAN driver index, 0 to disable DroneCAN

Values

Value

Meaning

0

Disabled

1

Driver1

2

Driver2

DID_OPTIONS: OpenDroneID options

Options for OpenDroneID subsystem

Bitmask

Bit

Meaning

0

EnforceArming

1

AllowNonGPSPosition

2

LockUASIDOnFirstBasicIDRx

DID_BARO_ACC: Barometer vertical accuraacy

Note: This parameter is for advanced users

Barometer Vertical Accuracy when installed in the vehicle. Note this is dependent upon installation conditions and thus disabled by default

Units

meters

EAHRS Parameters

EAHRS_TYPE: AHRS type

Type of AHRS device

Values

Value

Meaning

0

None

1

VectorNav

2

MicroStrain5

5

InertialLabs

7

MicroStrain7

EAHRS_RATE: AHRS data rate

Requested rate for AHRS device

Units

hertz

EAHRS_OPTIONS: External AHRS options

External AHRS options bitmask

Bitmask

Bit

Meaning

0

Vector Nav use uncompensated values for accel gyro and mag.

EAHRS_SENSORS: External AHRS sensors

Note: This parameter is for advanced users

External AHRS sensors bitmask

Bitmask

Bit

Meaning

0

GPS

1

IMU

2

Baro

3

Compass

EAHRS_LOG_RATE: AHRS logging rate

Logging rate for EARHS devices

Units

hertz

EFI Parameters

EFI_TYPE: EFI communication type

Note: This parameter is for advanced users
Note: Reboot required after change

What method of communication is used for EFI #1

Values

Value

Meaning

0

None

1

Serial-MS

2

NWPMU

3

Serial-Lutan

5

DroneCAN

6

Currawong-ECU

7

Scripting

8

Hirth

9

MAVLink

EFI_COEF1: EFI Calibration Coefficient 1

Note: This parameter is for advanced users

Used to calibrate fuel flow for MS protocol (Slope). This should be calculated from a log at constant fuel usage rate. Plot (ECYL[0].InjT*EFI.Rpm)/600.0 to get the duty_cycle. Measure actual fuel usage in cm^3/min, and set EFI_COEF1 = fuel_usage_cm3permin / duty_cycle

Range

0 to 1

EFI_COEF2: EFI Calibration Coefficient 2

Note: This parameter is for advanced users

Used to calibrate fuel flow for MS protocol (Offset). This can be used to correct for a non-zero offset in the fuel consumption calculation of EFI_COEF1

Range

0 to 10

EFI_FUEL_DENS: ECU Fuel Density

Note: This parameter is for advanced users

Used to calculate fuel consumption

Range

Units

0 to 10000

kilograms per cubic meter

EFI_THRLIN Parameters

EFI_THRLIN_EN: Enable throttle linearisation

Note: This parameter is for advanced users

Enable EFI throttle linearisation

Values

Value

Meaning

0

Disabled

1

Enabled

EFI_THRLIN_COEF1: Throttle linearisation - First Order

Note: This parameter is for advanced users
Note: Reboot required after change

First Order Polynomial Coefficient. (=1, if throttle is first order polynomial trendline)

Range

-1 to 1

EFI_THRLIN_COEF2: Throttle linearisation - Second Order

Note: This parameter is for advanced users
Note: Reboot required after change

Second Order Polynomial Coefficient (=0, if throttle is second order polynomial trendline)

Range

-1 to 1

EFI_THRLIN_COEF3: Throttle linearisation - Third Order

Note: This parameter is for advanced users
Note: Reboot required after change

Third Order Polynomial Coefficient. (=0, if throttle is third order polynomial trendline)

Range

-1 to 1

EFI_THRLIN_OFS: throttle linearization offset

Note: This parameter is for advanced users
Note: Reboot required after change

Offset for throttle linearization

Range

0 to 100

EK2_ Parameters

EK2_ENABLE: Enable EKF2

Note: This parameter is for advanced users
Note: Reboot required after change

This enables EKF2. Enabling EKF2 only makes the maths run, it does not mean it will be used for flight control. To use it for flight control set AHRS_EKF_TYPE=2. A reboot or restart will need to be performed after changing the value of EK2_ENABLE for it to take effect.

Values

Value

Meaning

0

Disabled

1

Enabled

EK2_GPS_TYPE: GPS mode control

Note: This parameter is for advanced users

This controls use of GPS measurements : 0 = use 3D velocity & 2D position, 1 = use 2D velocity and 2D position, 2 = use 2D position, 3 = Inhibit GPS use - this can be useful when flying with an optical flow sensor in an environment where GPS quality is poor and subject to large multipath errors.

Values

Value

Meaning

0

GPS 3D Vel and 2D Pos

1

GPS 2D vel and 2D pos

2

GPS 2D pos

3

No GPS

EK2_VELNE_M_NSE: GPS horizontal velocity measurement noise (m/s)

Note: This parameter is for advanced users

This sets a lower limit on the speed accuracy reported by the GPS receiver that is used to set horizontal velocity observation noise. If the model of receiver used does not provide a speed accurcy estimate, then the parameter value will be used. Increasing it reduces the weighting of the GPS horizontal velocity measurements.

Increment

Range

Units

0.05

0.05 to 5.0

meters per second

EK2_VELD_M_NSE: GPS vertical velocity measurement noise (m/s)

Note: This parameter is for advanced users

This sets a lower limit on the speed accuracy reported by the GPS receiver that is used to set vertical velocity observation noise. If the model of receiver used does not provide a speed accurcy estimate, then the parameter value will be used. Increasing it reduces the weighting of the GPS vertical velocity measurements.

Increment

Range

Units

0.05

0.05 to 5.0

meters per second

EK2_VEL_I_GATE: GPS velocity innovation gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the GPS velocity measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK2_POSNE_M_NSE: GPS horizontal position measurement noise (m)

Note: This parameter is for advanced users

This sets the GPS horizontal position observation noise. Increasing it reduces the weighting of GPS horizontal position measurements.

Increment

Range

Units

0.1

0.1 to 10.0

meters

EK2_POS_I_GATE: GPS position measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the GPS position measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK2_GLITCH_RAD: GPS glitch radius gate size (m)

Note: This parameter is for advanced users

This controls the maximum radial uncertainty in position between the value predicted by the filter and the value measured by the GPS before the filter position and velocity states are reset to the GPS. Making this value larger allows the filter to ignore larger GPS glitches but also means that non-GPS errors such as IMU and compass can create a larger error in position before the filter is forced back to the GPS position.

Increment

Range

Units

5

10 to 100

meters

EK2_ALT_SOURCE: Primary altitude sensor source

Note: This parameter is for advanced users
Note: Reboot required after change

Primary height sensor used by the EKF. If a sensor other than Baro is selected and becomes unavailable, then the Baro sensor will be used as a fallback. NOTE: The EK2_RNG_USE_HGT parameter can be used to switch to range-finder when close to the ground in conjunction with EK2_ALT_SOURCE = 0 or 2 (Baro or GPS).

Values

Value

Meaning

0

Use Baro

1

Use Range Finder

2

Use GPS

3

Use Range Beacon

EK2_ALT_M_NSE: Altitude measurement noise (m)

Note: This parameter is for advanced users

This is the RMS value of noise in the altitude measurement. Increasing it reduces the weighting of the baro measurement and will make the filter respond more slowly to baro measurement errors, but will make it more sensitive to GPS and accelerometer errors.

Increment

Range

Units

0.1

0.1 to 10.0

meters

EK2_HGT_I_GATE: Height measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the height measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK2_HGT_DELAY: Height measurement delay (msec)

Note: This parameter is for advanced users
Note: Reboot required after change

This is the number of msec that the Height measurements lag behind the inertial measurements.

Increment

Range

Units

10

0 to 250

milliseconds

EK2_MAG_M_NSE: Magnetometer measurement noise (Gauss)

Note: This parameter is for advanced users

This is the RMS value of noise in magnetometer measurements. Increasing it reduces the weighting on these measurements.

Increment

Range

Units

0.01

0.01 to 0.5

gauss

EK2_MAG_CAL: Magnetometer default fusion mode

Note: This parameter is for advanced users

This determines when the filter will use the 3-axis magnetometer fusion model that estimates both earth and body fixed magnetic field states, when it will use a simpler magnetic heading fusion model that does not use magnetic field states and when it will use an alternative method of yaw determination to the magnetometer. The 3-axis magnetometer fusion is only suitable for use when the external magnetic field environment is stable. EK2_MAG_CAL = 0 uses heading fusion on ground, 3-axis fusion in-flight, and is the default setting for Plane users. EK2_MAG_CAL = 1 uses 3-axis fusion only when manoeuvring. EK2_MAG_CAL = 2 uses heading fusion at all times, is recommended if the external magnetic field is varying and is the default for rovers. EK2_MAG_CAL = 3 uses heading fusion on the ground and 3-axis fusion after the first in-air field and yaw reset has completed, and is the default for copters. EK2_MAG_CAL = 4 uses 3-axis fusion at all times. NOTE: The fusion mode can be forced to 2 for specific EKF cores using the EK2_MAG_MASK parameter. NOTE: limited operation without a magnetometer or any other yaw sensor is possible by setting all COMPASS_USE, COMPASS_USE2, COMPASS_USE3, etc parameters to 0 with COMPASS_ENABLE set to 1. If this is done, the EK2_GSF_RUN and EK2_GSF_USE masks must be set to the same as EK2_IMU_MASK.

Values

Value

Meaning

0

When flying

1

When manoeuvring

2

Never

3

After first climb yaw reset

4

Always

EK2_MAG_I_GATE: Magnetometer measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the magnetometer measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK2_EAS_M_NSE: Equivalent airspeed measurement noise (m/s)

Note: This parameter is for advanced users

This is the RMS value of noise in equivalent airspeed measurements used by planes. Increasing it reduces the weighting of airspeed measurements and will make wind speed estimates less noisy and slower to converge. Increasing also increases navigation errors when dead-reckoning without GPS measurements.

Increment

Range

Units

0.1

0.5 to 5.0

meters per second

EK2_EAS_I_GATE: Airspeed measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the airspeed measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK2_RNG_M_NSE: Range finder measurement noise (m)

Note: This parameter is for advanced users

This is the RMS value of noise in the range finder measurement. Increasing it reduces the weighting on this measurement.

Increment

Range

Units

0.1

0.1 to 10.0

meters

EK2_RNG_I_GATE: Range finder measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the range finder innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK2_MAX_FLOW: Maximum valid optical flow rate

Note: This parameter is for advanced users

This sets the magnitude maximum optical flow rate in rad/sec that will be accepted by the filter

Increment

Range

Units

0.1

1.0 to 4.0

radians per second

EK2_FLOW_M_NSE: Optical flow measurement noise (rad/s)

Note: This parameter is for advanced users

This is the RMS value of noise and errors in optical flow measurements. Increasing it reduces the weighting on these measurements.

Increment

Range

Units

0.05

0.05 to 1.0

radians per second

EK2_FLOW_I_GATE: Optical Flow measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the optical flow innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK2_FLOW_DELAY: Optical Flow measurement delay (msec)

Note: This parameter is for advanced users
Note: Reboot required after change

This is the number of msec that the optical flow measurements lag behind the inertial measurements. It is the time from the end of the optical flow averaging period and does not include the time delay due to the 100msec of averaging within the flow sensor.

Increment

Range

Units

10

0 to 127

milliseconds

EK2_GYRO_P_NSE: Rate gyro noise (rad/s)

Note: This parameter is for advanced users

This control disturbance noise controls the growth of estimated error due to gyro measurement errors excluding bias. Increasing it makes the flter trust the gyro measurements less and other measurements more.

Increment

Range

Units

0.0001

0.0001 to 0.1

radians per second

EK2_ACC_P_NSE: Accelerometer noise (m/s^2)

Note: This parameter is for advanced users

This control disturbance noise controls the growth of estimated error due to accelerometer measurement errors excluding bias. Increasing it makes the flter trust the accelerometer measurements less and other measurements more.

Increment

Range

Units

0.01

0.01 to 1.0

meters per square second

EK2_GBIAS_P_NSE: Rate gyro bias stability (rad/s/s)

Note: This parameter is for advanced users

This state process noise controls growth of the gyro delta angle bias state error estimate. Increasing it makes rate gyro bias estimation faster and noisier.

Range

Units

0.00001 to 0.001

radians per square second

EK2_GSCL_P_NSE: Rate gyro scale factor stability (1/s)

Note: This parameter is for advanced users

This noise controls the rate of gyro scale factor learning. Increasing it makes rate gyro scale factor estimation faster and noisier.

Range

Units

0.000001 to 0.001

hertz

EK2_ABIAS_P_NSE: Accelerometer bias stability (m/s^3)

Note: This parameter is for advanced users

This noise controls the growth of the vertical accelerometer delta velocity bias state error estimate. Increasing it makes accelerometer bias estimation faster and noisier.

Range

Units

0.00001 to 0.005

meters per cubic second

EK2_WIND_P_NSE: Wind velocity process noise (m/s^2)

Note: This parameter is for advanced users

This state process noise controls the growth of wind state error estimates. Increasing it makes wind estimation faster and noisier.

Increment

Range

Units

0.1

0.01 to 1.0

meters per square second

EK2_WIND_PSCALE: Height rate to wind process noise scaler

Note: This parameter is for advanced users

This controls how much the process noise on the wind states is increased when gaining or losing altitude to take into account changes in wind speed and direction with altitude. Increasing this parameter increases how rapidly the wind states adapt when changing altitude, but does make wind velocity estimation noiser.

Increment

Range

0.1

0.0 to 1.0

EK2_GPS_CHECK: GPS preflight check

Note: This parameter is for advanced users

This is a 1 byte bitmap controlling which GPS preflight checks are performed. Set to 0 to bypass all checks. Set to 255 perform all checks. Set to 3 to check just the number of satellites and HDoP. Set to 31 for the most rigorous checks that will still allow checks to pass when the copter is moving, eg launch from a boat.

Bitmask

Bit

Meaning

0

NSats

1

HDoP

2

speed error

3

position error

4

yaw error

5

pos drift

6

vert speed

7

horiz speed

EK2_IMU_MASK: Bitmask of active IMUs

Note: This parameter is for advanced users
Note: Reboot required after change

1 byte bitmap of IMUs to use in EKF2. A separate instance of EKF2 will be started for each IMU selected. Set to 1 to use the first IMU only (default), set to 2 to use the second IMU only, set to 3 to use the first and second IMU. Additional IMU's can be used up to a maximum of 6 if memory and processing resources permit. There may be insufficient memory and processing resources to run multiple instances. If this occurs EKF2 will fail to start.

Bitmask

Bit

Meaning

0

FirstIMU

1

SecondIMU

2

ThirdIMU

3

FourthIMU

4

FifthIMU

5

SixthIMU

EK2_CHECK_SCALE: GPS accuracy check scaler (%)

Note: This parameter is for advanced users

This scales the thresholds that are used to check GPS accuracy before it is used by the EKF. A value of 100 is the default. Values greater than 100 increase and values less than 100 reduce the maximum GPS error the EKF will accept. A value of 200 will double the allowable GPS error.

Range

Units

50 to 200

percent

EK2_NOAID_M_NSE: Non-GPS operation position uncertainty (m)

Note: This parameter is for advanced users

This sets the amount of position variation that the EKF allows for when operating without external measurements (eg GPS or optical flow). Increasing this parameter makes the EKF attitude estimate less sensitive to vehicle manoeuvres but more sensitive to IMU errors.

Range

Units

0.5 to 50.0

meters

EK2_YAW_M_NSE: Yaw measurement noise (rad)

Note: This parameter is for advanced users

This is the RMS value of noise in yaw measurements from the magnetometer. Increasing it reduces the weighting on these measurements.

Increment

Range

Units

0.05

0.05 to 1.0

radians

EK2_YAW_I_GATE: Yaw measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the magnetometer yaw measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK2_TAU_OUTPUT: Output complementary filter time constant (centi-sec)

Note: This parameter is for advanced users

Sets the time constant of the output complementary filter/predictor in centi-seconds.

Increment

Range

Units

5

10 to 50

centiseconds

EK2_MAGE_P_NSE: Earth magnetic field process noise (gauss/s)

Note: This parameter is for advanced users

This state process noise controls the growth of earth magnetic field state error estimates. Increasing it makes earth magnetic field estimation faster and noisier.

Range

Units

0.00001 to 0.01

gauss per second

EK2_MAGB_P_NSE: Body magnetic field process noise (gauss/s)

Note: This parameter is for advanced users

This state process noise controls the growth of body magnetic field state error estimates. Increasing it makes magnetometer bias error estimation faster and noisier.

Range

Units

0.00001 to 0.01

gauss per second

EK2_RNG_USE_HGT: Range finder switch height percentage

Note: This parameter is for advanced users

Range finder can be used as the primary height source when below this percentage of its maximum range (see RNGFND_MAX_CM). This will not work unless Baro or GPS height is selected as the primary height source vis EK2_ALT_SOURCE = 0 or 2 respectively. This feature should not be used for terrain following as it is designed for vertical takeoff and landing with climb above the range finder use height before commencing the mission, and with horizontal position changes below that height being limited to a flat region around the takeoff and landing point.

Increment

Range

Units

1

-1 to 70

percent

EK2_TERR_GRAD: Maximum terrain gradient

Note: This parameter is for advanced users

Specifies the maximum gradient of the terrain below the vehicle assumed when it is fusing range finder or optical flow to estimate terrain height.

Increment

Range

0.01

0 to 0.2

EK2_BCN_M_NSE: Range beacon measurement noise (m)

Note: This parameter is for advanced users

This is the RMS value of noise in the range beacon measurement. Increasing it reduces the weighting on this measurement.

Increment

Range

Units

0.1

0.1 to 10.0

meters

EK2_BCN_I_GTE: Range beacon measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the range beacon measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK2_BCN_DELAY: Range beacon measurement delay (msec)

Note: This parameter is for advanced users
Note: Reboot required after change

This is the number of msec that the range beacon measurements lag behind the inertial measurements. It is the time from the end of the optical flow averaging period and does not include the time delay due to the 100msec of averaging within the flow sensor.

Increment

Range

Units

10

0 to 127

milliseconds

EK2_RNG_USE_SPD: Range finder max ground speed

Note: This parameter is for advanced users

The range finder will not be used as the primary height source when the horizontal ground speed is greater than this value.

Increment

Range

Units

0.5

2.0 to 6.0

meters per second

EK2_MAG_MASK: Bitmask of active EKF cores that will always use heading fusion

Note: This parameter is for advanced users
Note: Reboot required after change

1 byte bitmap of EKF cores that will disable magnetic field states and use simple magnetic heading fusion at all times. This parameter enables specified cores to be used as a backup for flight into an environment with high levels of external magnetic interference which may degrade the EKF attitude estimate when using 3-axis magnetometer fusion. NOTE : Use of a different magnetometer fusion algorithm on different cores makes unwanted EKF core switches due to magnetometer errors more likely.

Bitmask

Bit

Meaning

0

FirstEKF

1

SecondEKF

2

ThirdEKF

3

FourthEKF

4

FifthEKF

5

SixthEKF

EK2_OGN_HGT_MASK: Bitmask control of EKF reference height correction

Note: This parameter is for advanced users
Note: Reboot required after change

When a height sensor other than GPS is used as the primary height source by the EKF, the position of the zero height datum is defined by that sensor and its frame of reference. If a GPS height measurement is also available, then the height of the WGS-84 height datum used by the EKF can be corrected so that the height returned by the getLLH() function is compensated for primary height sensor drift and change in datum over time. The first two bit positions control when the height datum will be corrected. Correction is performed using a Bayes filter and only operates when GPS quality permits. The third bit position controls where the corrections to the GPS reference datum are applied. Corrections can be applied to the local vertical position or to the reported EKF origin height (default).

Bitmask

Bit

Meaning

0

Correct when using Baro height

1

Correct when using range finder height

2

Apply corrections to local position

EK2_FLOW_USE: Optical flow use bitmask

Note: This parameter is for advanced users
Note: Reboot required after change

Controls if the optical flow data is fused into the 24-state navigation estimator OR the 1-state terrain height estimator.

Values

Value

Meaning

0

None

1

Navigation

2

Terrain

EK2_MAG_EF_LIM: EarthField error limit

Note: This parameter is for advanced users

This limits the difference between the learned earth magnetic field and the earth field from the world magnetic model tables. A value of zero means to disable the use of the WMM tables.

Range

Units

0 to 500

milligauss

EK2_HRT_FILT: Height rate filter crossover frequency

Specifies the crossover frequency of the complementary filter used to calculate the output predictor height rate derivative.

Range

Units

0.1 to 30.0

hertz

EK2_GSF_RUN_MASK: Bitmask of which EKF-GSF yaw estimators run

Note: This parameter is for advanced users
Note: Reboot required after change

A bitmask of which EKF2 instances run an independant EKF-GSF yaw estimator to provide a backup yaw estimate that doesn't rely on magnetometer data. This estimator uses IMU, GPS and, if available, airspeed data. EKF-GSF yaw estimator data for the primary EKF2 instance will be logged as GSF0 and GSF1 messages. Use of the yaw estimate generated by this algorithm is controlled by the EK2_GSF_USE_MASK and EK2_GSF_RST_MAX parameters. To run the EKF-GSF yaw estimator in ride-along and logging only, set EK2_GSF_USE_MASK to 0.

Bitmask

Bit

Meaning

0

FirstEKF

1

SecondEKF

2

ThirdEKF

3

FourthEKF

4

FifthEKF

5

SixthEKF

EK2_GSF_USE_MASK: Bitmask of which EKF-GSF yaw estimators are used

Note: This parameter is for advanced users
Note: Reboot required after change

1 byte bitmap of which EKF2 instances will use the output from the EKF-GSF yaw estimator that has been turned on by the EK2_GSF_RUN_MASK parameter. If the inertial navigation calculation stops following the GPS, then the vehicle code can request EKF2 to attempt to resolve the issue, either by performing a yaw reset if enabled by this parameter by switching to another EKF2 instance.

Bitmask

Bit

Meaning

0

FirstEKF

1

SecondEKF

2

ThirdEKF

3

FourthEKF

4

FifthEKF

5

SixthEKF

EK2_GSF_RST_MAX: Maximum number of resets to the EKF-GSF yaw estimate allowed

Note: This parameter is for advanced users
Note: Reboot required after change

Sets the maximum number of times the EKF2 will be allowed to reset its yaw to the estimate from the EKF-GSF yaw estimator. No resets will be allowed unless the use of the EKF-GSF yaw estimate is enabled via the EK2_GSF_USE_MASK parameter.

Increment

Range

1

1 to 10

EK2_OPTIONS: Optional EKF behaviour

Note: This parameter is for advanced users

optional EKF2 behaviour. Disabling external navigation prevents use of external vision data in the EKF2 solution

Bitmask

Bit

Meaning

0

DisableExternalNavigation

EK3_ Parameters

EK3_ENABLE: Enable EKF3

Note: This parameter is for advanced users
Note: Reboot required after change

This enables EKF3. Enabling EKF3 only makes the maths run, it does not mean it will be used for flight control. To use it for flight control set AHRS_EKF_TYPE=3. A reboot or restart will need to be performed after changing the value of EK3_ENABLE for it to take effect.

Values

Value

Meaning

0

Disabled

1

Enabled

EK3_VELNE_M_NSE: GPS horizontal velocity measurement noise (m/s)

Note: This parameter is for advanced users

This sets a lower limit on the speed accuracy reported by the GPS receiver that is used to set horizontal velocity observation noise. If the model of receiver used does not provide a speed accurcy estimate, then the parameter value will be used. Increasing it reduces the weighting of the GPS horizontal velocity measurements.

Increment

Range

Units

0.05

0.05 to 5.0

meters per second

EK3_VELD_M_NSE: GPS vertical velocity measurement noise (m/s)

Note: This parameter is for advanced users

This sets a lower limit on the speed accuracy reported by the GPS receiver that is used to set vertical velocity observation noise. If the model of receiver used does not provide a speed accurcy estimate, then the parameter value will be used. Increasing it reduces the weighting of the GPS vertical velocity measurements.

Increment

Range

Units

0.05

0.05 to 5.0

meters per second

EK3_VEL_I_GATE: GPS velocity innovation gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the GPS velocity measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted. If EK3_GLITCH_RAD set to 0 the velocity innovations will be clipped instead of rejected if they exceed the gate size and a smaller value of EK3_VEL_I_GATE not exceeding 300 is recommended to limit the effect of GPS transient errors.

Increment

Range

25

100 to 1000

EK3_POSNE_M_NSE: GPS horizontal position measurement noise (m)

Note: This parameter is for advanced users

This sets the GPS horizontal position observation noise. Increasing it reduces the weighting of GPS horizontal position measurements.

Increment

Range

Units

0.1

0.1 to 10.0

meters

EK3_POS_I_GATE: GPS position measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the GPS position measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted. If EK3_GLITCH_RAD has been set to 0 the horizontal position innovations will be clipped instead of rejected if they exceed the gate size so a smaller value of EK3_POS_I_GATE not exceeding 300 is recommended to limit the effect of GPS transient errors.

Increment

Range

25

100 to 1000

EK3_GLITCH_RAD: GPS glitch radius gate size (m)

Note: This parameter is for advanced users

This controls the maximum radial uncertainty in position between the value predicted by the filter and the value measured by the GPS before the filter position and velocity states are reset to the GPS. Making this value larger allows the filter to ignore larger GPS glitches but also means that non-GPS errors such as IMU and compass can create a larger error in position before the filter is forced back to the GPS position. If EK3_GLITCH_RAD set to 0 the GPS innovations will be clipped instead of rejected if they exceed the gate size set by EK3_VEL_I_GATE and EK3_POS_I_GATE which can be useful if poor quality sensor data is causing GPS rejection and loss of navigation but does make the EKF more susceptible to GPS glitches. If setting EK3_GLITCH_RAD to 0 it is recommended to reduce EK3_VEL_I_GATE and EK3_POS_I_GATE to 300.

Increment

Range

Units

5

10 to 100

meters

EK3_ALT_M_NSE: Altitude measurement noise (m)

Note: This parameter is for advanced users

This is the RMS value of noise in the altitude measurement. Increasing it reduces the weighting of the baro measurement and will make the filter respond more slowly to baro measurement errors, but will make it more sensitive to GPS and accelerometer errors. A larger value for EK3_ALT_M_NSE may be required when operating with EK3_SRCx_POSZ = 0. This parameter also sets the noise for the 'synthetic' zero height measurement that is used when EK3_SRCx_POSZ = 0.

Increment

Range

Units

0.1

0.1 to 100.0

meters

EK3_HGT_I_GATE: Height measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the height measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted. If EK3_GLITCH_RAD set to 0 the vertical position innovations will be clipped instead of rejected if they exceed the gate size and a smaller value of EK3_HGT_I_GATE not exceeding 300 is recommended to limit the effect of height sensor transient errors.

Increment

Range

25

100 to 1000

EK3_HGT_DELAY: Height measurement delay (msec)

Note: This parameter is for advanced users
Note: Reboot required after change

This is the number of msec that the Height measurements lag behind the inertial measurements.

Increment

Range

Units

10

0 to 250

milliseconds

EK3_MAG_M_NSE: Magnetometer measurement noise (Gauss)

Note: This parameter is for advanced users

This is the RMS value of noise in magnetometer measurements. Increasing it reduces the weighting on these measurements.

Increment

Range

Units

0.01

0.01 to 0.5

gauss

EK3_MAG_CAL: Magnetometer default fusion mode

Note: This parameter is for advanced users
Note: Reboot required after change

This determines when the filter will use the 3-axis magnetometer fusion model that estimates both earth and body fixed magnetic field states and when it will use a simpler magnetic heading fusion model that does not use magnetic field states. The 3-axis magnetometer fusion is only suitable for use when the external magnetic field environment is stable. EK3_MAG_CAL = 0 uses heading fusion on ground, 3-axis fusion in-flight, and is the default setting for Plane users. EK3_MAG_CAL = 1 uses 3-axis fusion only when manoeuvring. EK3_MAG_CAL = 2 uses heading fusion at all times, is recommended if the external magnetic field is varying and is the default for rovers. EK3_MAG_CAL = 3 uses heading fusion on the ground and 3-axis fusion after the first in-air field and yaw reset has completed, and is the default for copters. EK3_MAG_CAL = 4 uses 3-axis fusion at all times. EK3_MAG_CAL = 5 uses an external yaw sensor with simple heading fusion. NOTE : Use of simple heading magnetometer fusion makes vehicle compass calibration and alignment errors harder for the EKF to detect which reduces the sensitivity of the Copter EKF failsafe algorithm. NOTE: The fusion mode can be forced to 2 for specific EKF cores using the EK3_MAG_MASK parameter. EK3_MAG_CAL = 6 uses an external yaw sensor with fallback to compass when the external sensor is not available if we are flying. NOTE: The fusion mode can be forced to 2 for specific EKF cores using the EK3_MAG_MASK parameter. NOTE: limited operation without a magnetometer or any other yaw sensor is possible by setting all COMPASS_USE, COMPASS_USE2, COMPASS_USE3, etc parameters to 0 and setting COMPASS_ENABLE to 0. If this is done, the EK3_GSF_RUN and EK3_GSF_USE masks must be set to the same as EK3_IMU_MASK. A yaw angle derived from IMU and GPS velocity data using a Gaussian Sum Filter (GSF) will then be used to align the yaw when flight commences and there is sufficient movement.

Values

Value

Meaning

0

When flying

1

When manoeuvring

2

Never

3

After first climb yaw reset

4

Always

5

Use external yaw sensor (Deprecated in 4.1+ see EK3_SRCn_YAW)

6

External yaw sensor with compass fallback (Deprecated in 4.1+ see EK3_SRCn_YAW)

EK3_MAG_I_GATE: Magnetometer measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the magnetometer measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK3_EAS_M_NSE: Equivalent airspeed measurement noise (m/s)

Note: This parameter is for advanced users

This is the RMS value of noise in equivalent airspeed measurements used by planes. Increasing it reduces the weighting of airspeed measurements and will make wind speed estimates less noisy and slower to converge. Increasing also increases navigation errors when dead-reckoning without GPS measurements.

Increment

Range

Units

0.1

0.5 to 5.0

meters per second

EK3_EAS_I_GATE: Airspeed measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the airspeed measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK3_RNG_M_NSE: Range finder measurement noise (m)

Note: This parameter is for advanced users

This is the RMS value of noise in the range finder measurement. Increasing it reduces the weighting on this measurement.

Increment

Range

Units

0.1

0.1 to 10.0

meters

EK3_RNG_I_GATE: Range finder measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the range finder innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK3_MAX_FLOW: Maximum valid optical flow rate

Note: This parameter is for advanced users

This sets the magnitude maximum optical flow rate in rad/sec that will be accepted by the filter

Increment

Range

Units

0.1

1.0 to 4.0

radians per second

EK3_FLOW_M_NSE: Optical flow measurement noise (rad/s)

Note: This parameter is for advanced users

This is the RMS value of noise and errors in optical flow measurements. Increasing it reduces the weighting on these measurements.

Increment

Range

Units

0.05

0.05 to 1.0

radians per second

EK3_FLOW_I_GATE: Optical Flow measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the optical flow innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK3_FLOW_DELAY: Optical Flow measurement delay (msec)

Note: This parameter is for advanced users
Note: Reboot required after change

This is the number of msec that the optical flow measurements lag behind the inertial measurements. It is the time from the end of the optical flow averaging period and does not include the time delay due to the 100msec of averaging within the flow sensor.

Increment

Range

Units

10

0 to 250

milliseconds

EK3_GYRO_P_NSE: Rate gyro noise (rad/s)

Note: This parameter is for advanced users

This control disturbance noise controls the growth of estimated error due to gyro measurement errors excluding bias. Increasing it makes the flter trust the gyro measurements less and other measurements more.

Increment

Range

Units

0.0001

0.0001 to 0.1

radians per second

EK3_ACC_P_NSE: Accelerometer noise (m/s^2)

Note: This parameter is for advanced users

This control disturbance noise controls the growth of estimated error due to accelerometer measurement errors excluding bias. Increasing it makes the flter trust the accelerometer measurements less and other measurements more.

Increment

Range

Units

0.01

0.01 to 1.0

meters per square second

EK3_GBIAS_P_NSE: Rate gyro bias stability (rad/s/s)

Note: This parameter is for advanced users

This state process noise controls growth of the gyro delta angle bias state error estimate. Increasing it makes rate gyro bias estimation faster and noisier.

Range

Units

0.00001 to 0.001

radians per square second

EK3_ABIAS_P_NSE: Accelerometer bias stability (m/s^3)

Note: This parameter is for advanced users

This noise controls the growth of the vertical accelerometer delta velocity bias state error estimate. Increasing it makes accelerometer bias estimation faster and noisier.

Range

Units

0.00001 to 0.02

meters per cubic second

EK3_WIND_P_NSE: Wind velocity process noise (m/s^2)

Note: This parameter is for advanced users

This state process noise controls the growth of wind state error estimates. Increasing it makes wind estimation faster and noisier.

Increment

Range

Units

0.1

0.01 to 2.0

meters per square second

EK3_WIND_PSCALE: Height rate to wind process noise scaler

Note: This parameter is for advanced users

This controls how much the process noise on the wind states is increased when gaining or losing altitude to take into account changes in wind speed and direction with altitude. Increasing this parameter increases how rapidly the wind states adapt when changing altitude, but does make wind velocity estimation noiser.

Increment

Range

0.1

0.0 to 2.0

EK3_GPS_CHECK: GPS preflight check

Note: This parameter is for advanced users

This is a 1 byte bitmap controlling which GPS preflight checks are performed. Set to 0 to bypass all checks. Set to 255 perform all checks. Set to 3 to check just the number of satellites and HDoP. Set to 31 for the most rigorous checks that will still allow checks to pass when the copter is moving, eg launch from a boat.

Bitmask

Bit

Meaning

0

NSats

1

HDoP

2

speed error

3

position error

4

yaw error

5

pos drift

6

vert speed

7

horiz speed

EK3_IMU_MASK: Bitmask of active IMUs

Note: This parameter is for advanced users
Note: Reboot required after change

1 byte bitmap of IMUs to use in EKF3. A separate instance of EKF3 will be started for each IMU selected. Set to 1 to use the first IMU only (default), set to 2 to use the second IMU only, set to 3 to use the first and second IMU. Additional IMU's can be used up to a maximum of 6 if memory and processing resources permit. There may be insufficient memory and processing resources to run multiple instances. If this occurs EKF3 will fail to start.

Bitmask

Bit

Meaning

0

FirstIMU

1

SecondIMU

2

ThirdIMU

3

FourthIMU

4

FifthIMU

5

SixthIMU

EK3_CHECK_SCALE: GPS accuracy check scaler (%)

Note: This parameter is for advanced users

This scales the thresholds that are used to check GPS accuracy before it is used by the EKF. A value of 100 is the default. Values greater than 100 increase and values less than 100 reduce the maximum GPS error the EKF will accept. A value of 200 will double the allowable GPS error.

Range

Units

50 to 200

percent

EK3_NOAID_M_NSE: Non-GPS operation position uncertainty (m)

Note: This parameter is for advanced users

This sets the amount of position variation that the EKF allows for when operating without external measurements (eg GPS or optical flow). Increasing this parameter makes the EKF attitude estimate less sensitive to vehicle manoeuvres but more sensitive to IMU errors.

Range

Units

0.5 to 50.0

meters

EK3_BETA_MASK: Bitmask controlling sidelip angle fusion

Note: This parameter is for advanced users
Note: Reboot required after change

1 byte bitmap controlling use of sideslip angle fusion for estimation of non wind states during operation of 'fly forward' vehicle types such as fixed wing planes. By assuming that the angle of sideslip is small, the wind velocity state estimates are corrected whenever the EKF is not dead reckoning (e.g. has an independent velocity or position sensor such as GPS). This behaviour is on by default and cannot be disabled. When the EKF is dead reckoning, the wind states are used as a reference, enabling use of the small angle of sideslip assumption to correct non wind velocity states (eg attitude, velocity, position, etc) and improve navigation accuracy. This behaviour is on by default and cannot be disabled. The behaviour controlled by this parameter is the use of the small angle of sideslip assumption to correct non wind velocity states when the EKF is NOT dead reckoning. This is primarily of benefit to reduce the buildup of yaw angle errors during straight and level flight without a yaw sensor (e.g. magnetometer or dual antenna GPS yaw) provided aerobatic flight maneuvers with large sideslip angles are not performed. The 'always' option might be used where the yaw sensor is intentionally not fitted or disabled. The 'WhenNoYawSensor' option might be used if a yaw sensor is fitted, but protection against in-flight failure and continual rejection by the EKF is desired. For vehicles operated within visual range of the operator performing frequent turning maneuvers, setting this parameter is unnecessary.

Bitmask

Bit

Meaning

0

Always

1

WhenNoYawSensor

EK3_YAW_M_NSE: Yaw measurement noise (rad)

Note: This parameter is for advanced users

This is the RMS value of noise in yaw measurements from the magnetometer. Increasing it reduces the weighting on these measurements.

Increment

Range

Units

0.05

0.05 to 1.0

radians

EK3_YAW_I_GATE: Yaw measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the magnetometer yaw measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK3_TAU_OUTPUT: Output complementary filter time constant (centi-sec)

Note: This parameter is for advanced users

Sets the time constant of the output complementary filter/predictor in centi-seconds.

Increment

Range

Units

5

10 to 50

centiseconds

EK3_MAGE_P_NSE: Earth magnetic field process noise (gauss/s)

Note: This parameter is for advanced users

This state process noise controls the growth of earth magnetic field state error estimates. Increasing it makes earth magnetic field estimation faster and noisier.

Range

Units

0.00001 to 0.01

gauss per second

EK3_MAGB_P_NSE: Body magnetic field process noise (gauss/s)

Note: This parameter is for advanced users

This state process noise controls the growth of body magnetic field state error estimates. Increasing it makes magnetometer bias error estimation faster and noisier.

Range

Units

0.00001 to 0.01

gauss per second

EK3_RNG_USE_HGT: Range finder switch height percentage

Note: This parameter is for advanced users

Range finder can be used as the primary height source when below this percentage of its maximum range (see RNGFNDx_MAX_CM) and the primary height source is Baro or GPS (see EK3_SRCx_POSZ). This feature should not be used for terrain following as it is designed for vertical takeoff and landing with climb above the range finder use height before commencing the mission, and with horizontal position changes below that height being limited to a flat region around the takeoff and landing point.

Increment

Range

Units

1

-1 to 70

percent

EK3_TERR_GRAD: Maximum terrain gradient

Note: This parameter is for advanced users

Specifies the maximum gradient of the terrain below the vehicle when it is using range finder as a height reference

Increment

Range

0.01

0 to 0.2

EK3_BCN_M_NSE: Range beacon measurement noise (m)

Note: This parameter is for advanced users

This is the RMS value of noise in the range beacon measurement. Increasing it reduces the weighting on this measurement.

Increment

Range

Units

0.1

0.1 to 10.0

meters

EK3_BCN_I_GTE: Range beacon measurement gate size

Note: This parameter is for advanced users

This sets the percentage number of standard deviations applied to the range beacon measurement innovation consistency check. Decreasing it makes it more likely that good measurements will be rejected. Increasing it makes it more likely that bad measurements will be accepted.

Increment

Range

25

100 to 1000

EK3_BCN_DELAY: Range beacon measurement delay (msec)

Note: This parameter is for advanced users
Note: Reboot required after change

This is the number of msec that the range beacon measurements lag behind the inertial measurements.

Increment

Range

Units

10

0 to 250

milliseconds

EK3_RNG_USE_SPD: Range finder max ground speed

Note: This parameter is for advanced users

The range finder will not be used as the primary height source when the horizontal ground speed is greater than this value.

Increment

Range

Units

0.5

2.0 to 6.0

meters per second

EK3_ACC_BIAS_LIM: Accelerometer bias limit

Note: This parameter is for advanced users

The accelerometer bias state will be limited to +- this value

Increment

Range

Units

0.1

0.5 to 2.5

meters per square second

EK3_MAG_MASK: Bitmask of active EKF cores that will always use heading fusion

Note: This parameter is for advanced users
Note: Reboot required after change

1 byte bitmap of EKF cores that will disable magnetic field states and use simple magnetic heading fusion at all times. This parameter enables specified cores to be used as a backup for flight into an environment with high levels of external magnetic interference which may degrade the EKF attitude estimate when using 3-axis magnetometer fusion. NOTE : Use of a different magnetometer fusion algorithm on different cores makes unwanted EKF core switches due to magnetometer errors more likely.

Bitmask

Bit

Meaning

0

FirstEKF

1

SecondEKF

2

ThirdEKF

3

FourthEKF

4

FifthEKF

5

SixthEKF

EK3_OGN_HGT_MASK: Bitmask control of EKF reference height correction

Note: This parameter is for advanced users
Note: Reboot required after change

When a height sensor other than GPS is used as the primary height source by the EKF, the position of the zero height datum is defined by that sensor and its frame of reference. If a GPS height measurement is also available, then the height of the WGS-84 height datum used by the EKF can be corrected so that the height returned by the getLLH() function is compensated for primary height sensor drift and change in datum over time. The first two bit positions control when the height datum will be corrected. Correction is performed using a Bayes filter and only operates when GPS quality permits. The third bit position controls where the corrections to the GPS reference datum are applied. Corrections can be applied to the local vertical position or to the reported EKF origin height (default).

Bitmask

Bit

Meaning

0

Correct when using Baro height

1

Correct when using range finder height

2

Apply corrections to local position

EK3_VIS_VERR_MIN: Visual odometry minimum velocity error

Note: This parameter is for advanced users

This is the 1-STD odometry velocity observation error that will be assumed when maximum quality is reported by the sensor. When quality is between max and min, the error will be calculated using linear interpolation between VIS_VERR_MIN and VIS_VERR_MAX.

Increment

Range

Units

0.05

0.05 to 0.5

meters per second

EK3_VIS_VERR_MAX: Visual odometry maximum velocity error

Note: This parameter is for advanced users

This is the 1-STD odometry velocity observation error that will be assumed when minimum quality is reported by the sensor. When quality is between max and min, the error will be calculated using linear interpolation between VIS_VERR_MIN and VIS_VERR_MAX.

Increment

Range

Units

0.1

0.5 to 5.0

meters per second

EK3_WENC_VERR: Wheel odometry velocity error

Note: This parameter is for advanced users

This is the 1-STD odometry velocity observation error that will be assumed when wheel encoder data is being fused.

Increment

Range

Units

0.1

0.01 to 1.0

meters per second

EK3_FLOW_USE: Optical flow use bitmask

Note: This parameter is for advanced users
Note: Reboot required after change

Controls if the optical flow data is fused into the 24-state navigation estimator OR the 1-state terrain height estimator.

Values

Value

Meaning

0

None

1

Navigation

2

Terrain

EK3_HRT_FILT: Height rate filter crossover frequency

Specifies the crossover frequency of the complementary filter used to calculate the output predictor height rate derivative.

Range

Units

0.1 to 30.0

hertz

EK3_MAG_EF_LIM: EarthField error limit

Note: This parameter is for advanced users

This limits the difference between the learned earth magnetic field and the earth field from the world magnetic model tables. A value of zero means to disable the use of the WMM tables.

Range

Units

0 to 500

milligauss

EK3_GSF_RUN_MASK: Bitmask of which EKF-GSF yaw estimators run

Note: This parameter is for advanced users
Note: Reboot required after change

1 byte bitmap of which EKF3 instances run an independant EKF-GSF yaw estimator to provide a backup yaw estimate that doesn't rely on magnetometer data. This estimator uses IMU, GPS and, if available, airspeed data. EKF-GSF yaw estimator data for the primary EKF3 instance will be logged as GSF0 and GSF1 messages. Use of the yaw estimate generated by this algorithm is controlled by the EK3_GSF_USE_MASK and EK3_GSF_RST_MAX parameters. To run the EKF-GSF yaw estimator in ride-along and logging only, set EK3_GSF_USE to 0.

Bitmask

Bit

Meaning

0

FirstEKF

1

SecondEKF

2

ThirdEKF

3

FourthEKF

4

FifthEKF

5

SixthEKF

EK3_GSF_USE_MASK: Bitmask of which EKF-GSF yaw estimators are used

Note: This parameter is for advanced users
Note: Reboot required after change

A bitmask of which EKF3 instances will use the output from the EKF-GSF yaw estimator that has been turned on by the EK3_GSF_RUN_MASK parameter. If the inertial navigation calculation stops following the GPS, then the vehicle code can request EKF3 to attempt to resolve the issue, either by performing a yaw reset if enabled by this parameter by switching to another EKF3 instance.

Bitmask

Bit

Meaning

0

FirstEKF

1

SecondEKF

2

ThirdEKF

3

FourthEKF

4

FifthEKF

5

SixthEKF

EK3_GSF_RST_MAX: Maximum number of resets to the EKF-GSF yaw estimate allowed

Note: This parameter is for advanced users
Note: Reboot required after change

Sets the maximum number of times the EKF3 will be allowed to reset its yaw to the estimate from the EKF-GSF yaw estimator. No resets will be allowed unless the use of the EKF-GSF yaw estimate is enabled via the EK3_GSF_USE_MASK parameter.

Increment

Range

1

1 to 10

EK3_ERR_THRESH: EKF3 Lane Relative Error Sensitivity Threshold

Note: This parameter is for advanced users

lanes have to be consistently better than the primary by at least this threshold to reduce their overall relativeCoreError, lowering this makes lane switching more sensitive to smaller error differences

Increment

Range

0.05

0.05 to 1

EK3_AFFINITY: EKF3 Sensor Affinity Options

Note: This parameter is for advanced users
Note: Reboot required after change

These options control the affinity between sensor instances and EKF cores

Bitmask

Bit

Meaning

0

EnableGPSAffinity

1

EnableBaroAffinity

2

EnableCompassAffinity

3

EnableAirspeedAffinity

EK3_DRAG_BCOEF_X: Ballistic coefficient for X axis drag

Note: This parameter is for advanced users

Ratio of mass to drag coefficient measured along the X body axis. This parameter enables estimation of wind drift for vehicles with bluff bodies and without propulsion forces in the X and Y direction (eg multicopters). The drag produced by this effect scales with speed squared. Set to a postive value > 1.0 to enable. A starting value is the mass in Kg divided by the frontal area. The predicted drag from the rotors is specified separately by the EK3_DRAG_MCOEF parameter.

Range

Units

0.0 to 1000.0

kilograms per square meter

EK3_DRAG_BCOEF_Y: Ballistic coefficient for Y axis drag

Note: This parameter is for advanced users

Ratio of mass to drag coefficient measured along the Y body axis. This parameter enables estimation of wind drift for vehicles with bluff bodies and without propulsion forces in the X and Y direction (eg multicopters). The drag produced by this effect scales with speed squared. Set to a postive value > 1.0 to enable. A starting value is the mass in Kg divided by the side area. The predicted drag from the rotors is specified separately by the EK3_DRAG_MCOEF parameter.

Range

Units

50.0 to 1000.0

kilograms per square meter

EK3_DRAG_M_NSE: Observation noise for drag acceleration

Note: This parameter is for advanced users

This sets the amount of noise used when fusing X and Y acceleration as an observation that enables esitmation of wind velocity for multi-rotor vehicles. This feature is enabled by the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters

Increment

Range

Units

0.1

0.1 to 2.0

meters per square second

EK3_DRAG_MCOEF: Momentum coefficient for propeller drag

Note: This parameter is for advanced users

This parameter is used to predict the drag produced by the rotors when flying a multi-copter, enabling estimation of wind drift. The drag produced by this effect scales with speed not speed squared and is produced because some of the air velocity normal to the rotors axis of rotation is lost when passing through the rotor disc which changes the momentum of the airflow causing drag. For unducted rotors the effect is roughly proportional to the area of the propeller blades when viewed side on and changes with different propellers. It is higher for ducted rotors. For example if flying at 15 m/s at sea level conditions produces a rotor induced drag acceleration of 1.5 m/s/s, then EK3_DRAG_MCOEF would be set to 0.1 = (1.5/15.0). Set EK3_MCOEF to a postive value to enable wind estimation using this drag effect. To account for the drag produced by the body which scales with speed squared, see documentation for the EK3_DRAG_BCOEF_X and EK3_DRAG_BCOEF_Y parameters.

Increment

Range

Units

0.01

0.0 to 1.0

per second

EK3_OGNM_TEST_SF: On ground not moving test scale factor

Note: This parameter is for advanced users

This parameter is adjust the sensitivity of the on ground not moving test which is used to assist with learning the yaw gyro bias and stopping yaw drift before flight when operating without a yaw sensor. Bigger values allow the detection of a not moving condition with noiser IMU data. Check the XKFM data logged when the vehicle is on ground not moving and adjust the value of OGNM_TEST_SF to be slightly higher than the maximum value of the XKFM.ADR, XKFM.ALR, XKFM.GDR and XKFM.GLR test levels.

Increment

Range

0.5

1.0 to 10.0

EK3_GND_EFF_DZ: Baro height ground effect dead zone

Note: This parameter is for advanced users

This parameter sets the size of the dead zone that is applied to negative baro height spikes that can occur when taking off or landing when a vehicle with lift rotors is operating in ground effect ground effect. Set to about 0.5m less than the amount of negative offset in baro height that occurs just prior to takeoff when lift motors are spooling up. Set to 0 if no ground effect is present.

Increment

Range

0.5

0.0 to 10.0

EK3_PRIMARY: Primary core number

Note: This parameter is for advanced users

The core number (index in IMU mask) that will be used as the primary EKF core on startup. While disarmed the EKF will force the use of this core. A value of 0 corresponds to the first IMU in EK3_IMU_MASK.

Increment

Range

1

0 to 2

EK3_LOG_LEVEL: Logging Level

Note: This parameter is for advanced users

Determines how verbose the EKF3 streaming logging is. A value of 0 provides full logging(default), a value of 1 only XKF4 scaled innovations are logged, a value of 2 both XKF4 and GSF are logged, and a value of 3 disables all streaming logging of EKF3.

Increment

Range

1

0 to 3

EK3_GPS_VACC_MAX: GPS vertical accuracy threshold

Note: This parameter is for advanced users

Vertical accuracy threshold for GPS as the altitude source. The GPS will not be used as an altitude source if the reported vertical accuracy of the GPS is larger than this threshold, falling back to baro instead. Set to zero to deactivate the threshold check.

Increment

Range

Units

0.1

0.0 to 10.0

meters

EK3_OPTIONS: Optional EKF behaviour

Note: This parameter is for advanced users

This controls optional EKF behaviour. Setting JammingExpected will change the EKF nehaviour such that if dead reckoning navigation is possible it will require the preflight alignment GPS quality checks controlled by EK3_GPS_CHECK and EK3_CHECK_SCALE to pass before resuming GPS use if GPS lock is lost for more than 2 seconds to prevent bad

Bitmask

Bit

Meaning

0

JammingExpected

EK3_SRC Parameters

EK3_SRC1_POSXY: Position Horizontal Source (Primary)

Note: This parameter is for advanced users

Position Horizontal Source (Primary)

Values

Value

Meaning

0

None

3

GPS

4

Beacon

6

ExternalNav

EK3_SRC1_VELXY: Velocity Horizontal Source

Note: This parameter is for advanced users

Velocity Horizontal Source

Values

Value

Meaning

0

None

3

GPS

4

Beacon

5

OpticalFlow

6

ExternalNav

7

WheelEncoder

EK3_SRC1_POSZ: Position Vertical Source

Note: This parameter is for advanced users

Position Vertical Source

Values

Value

Meaning

0

None

1

Baro

2

RangeFinder

3

GPS

4

Beacon

6

ExternalNav

EK3_SRC1_VELZ: Velocity Vertical Source

Note: This parameter is for advanced users

Velocity Vertical Source

Values

Value

Meaning

0

None

3

GPS

4

Beacon

6

ExternalNav

EK3_SRC1_YAW: Yaw Source

Note: This parameter is for advanced users

Yaw Source

Values

Value

Meaning

0

None

1

Compass

2

GPS

3

GPS with Compass Fallback

6

ExternalNav

8

GSF

EK3_SRC2_POSXY: Position Horizontal Source (Secondary)

Note: This parameter is for advanced users

Position Horizontal Source (Secondary)

Values

Value

Meaning

0

None

3

GPS

4

Beacon

6

ExternalNav

EK3_SRC2_VELXY: Velocity Horizontal Source (Secondary)

Note: This parameter is for advanced users

Velocity Horizontal Source (Secondary)

Values

Value

Meaning

0

None

3

GPS

4

Beacon

5

OpticalFlow

6

ExternalNav

7

WheelEncoder

EK3_SRC2_POSZ: Position Vertical Source (Secondary)

Note: This parameter is for advanced users

Position Vertical Source (Secondary)

Values

Value

Meaning

0

None

1

Baro

2

RangeFinder

3

GPS

4

Beacon

6

ExternalNav

EK3_SRC2_VELZ: Velocity Vertical Source (Secondary)

Note: This parameter is for advanced users

Velocity Vertical Source (Secondary)

Values

Value

Meaning

0

None

3

GPS

4

Beacon

6

ExternalNav

EK3_SRC2_YAW: Yaw Source (Secondary)

Note: This parameter is for advanced users

Yaw Source (Secondary)

Values

Value

Meaning

0

None

1

Compass

2

GPS

3

GPS with Compass Fallback

6

ExternalNav

8

GSF

EK3_SRC3_POSXY: Position Horizontal Source (Tertiary)

Note: This parameter is for advanced users

Position Horizontal Source (Tertiary)

Values

Value

Meaning

0

None

3

GPS

4

Beacon

6

ExternalNav

EK3_SRC3_VELXY: Velocity Horizontal Source (Tertiary)

Note: This parameter is for advanced users

Velocity Horizontal Source (Tertiary)

Values

Value

Meaning

0

None

3

GPS

4

Beacon

5

OpticalFlow

6

ExternalNav

7

WheelEncoder

EK3_SRC3_POSZ: Position Vertical Source (Tertiary)

Note: This parameter is for advanced users

Position Vertical Source (Tertiary)

Values

Value

Meaning

0

None

1

Baro

2

RangeFinder

3

GPS

4

Beacon

6

ExternalNav

EK3_SRC3_VELZ: Velocity Vertical Source (Tertiary)

Note: This parameter is for advanced users

Velocity Vertical Source (Tertiary)

Values

Value

Meaning

0

None

3

GPS

4

Beacon

6

ExternalNav

EK3_SRC3_YAW: Yaw Source (Tertiary)

Note: This parameter is for advanced users

Yaw Source (Tertiary)

Values

Value

Meaning

0

None

1

Compass

2

GPS

3

GPS with Compass Fallback

6

ExternalNav

8

GSF

EK3_SRC_OPTIONS: EKF Source Options

Note: This parameter is for advanced users

EKF Source Options

Bitmask

Bit

Meaning

0

FuseAllVelocities

1

AlignExtNavPosWhenUsingOptFlow

ESC_TLM Parameters

FENCE_ Parameters

FENCE_ENABLE: Fence enable/disable

Allows you to enable (1) or disable (0) the fence functionality. Fences can still be enabled and disabled via mavlink or an RC option, but these changes are not persisted.

Values

Value

Meaning

0

Disabled

1

Enabled

FENCE_TYPE: Fence Type

Configured fence types held as bitmask. Max altitide, Circle and Polygon fences will be immediately enabled if configured. Min altitude fence will only be enabled once the minimum altitude is reached.

Bitmask

Bit

Meaning

0

Max altitude

1

Circle Centered on Home

2

Inclusion/Exclusion Circles+Polygons

3

Min altitude

FENCE_ACTION: Fence Action

What action should be taken when fence is breached

Values

Value

Meaning

0

Report Only

1

RTL or Land

2

Always Land

3

SmartRTL or RTL or Land

4

Brake or Land

5

SmartRTL or Land

FENCE_ALT_MAX: Fence Maximum Altitude

Maximum altitude allowed before geofence triggers

Increment

Range

Units

1

10 to 1000

meters

FENCE_RADIUS: Circular Fence Radius

Circle fence radius which when breached will cause an RTL

Range

Units

30 to 10000

meters

FENCE_MARGIN: Fence Margin

Distance that autopilot's should maintain from the fence to avoid a breach

Range

Units

1 to 10

meters

FENCE_TOTAL: Fence polygon point total

Number of polygon points saved in eeprom (do not update manually)

Range

1 to 20

FENCE_ALT_MIN: Fence Minimum Altitude

Minimum altitude allowed before geofence triggers

Increment

Range

Units

1

-100 to 100

meters

FENCE_AUTOENABLE: Fence Auto-Enable

Auto-enable of fences. AutoEnableOnTakeoff enables all configured fences, except the minimum altitude fence (which is enabled when the minimum altitude is reached), after autotakeoffs reach altitude. During autolandings the fences will be disabled. AutoEnableDisableFloorOnLanding enables all configured fences, except the minimum altitude fence (which is enabled when the minimum altitude is reached), after autotakeoffs reach altitude. During autolandings only the Minimum Altitude fence will be disabled. AutoEnableOnlyWhenArmed enables all configured fences on arming, except the minimum altitude fence (which is enabled when the minimum altitude is reached), but no fences are disabled during autolandings. However, fence breaches are ignored while executing prior breach recovery actions which may include autolandings.

Increment

Range

Values

1

0 to 3

Value

Meaning

0

AutoEnableOff

1

AutoEnableOnTakeoff

2

AutoEnableDisableFloorOnLanding

3

AutoEnableOnlyWhenArmed

FENCE_OPTIONS: Fence options

When bit 0 is set sisable mode change following fence action until fence breach is cleared. When bit 1 is set the allowable flight areas is the union of all polygon and circle fence areas instead of the intersection, which means a fence breach occurs only if you are outside all of the fence areas.

Bitmask

Bit

Meaning

0

Disable mode change following fence action until fence breach is cleared

1

Allow union of inclusion areas

FFT_ Parameters

FFT_ENABLE: Enable

Note: This parameter is for advanced users
Note: Reboot required after change

Enable Gyro FFT analyser

Values

Value

Meaning

0

Disabled

1

Enabled

FFT_MINHZ: Minimum Frequency

Note: This parameter is for advanced users

Lower bound of FFT frequency detection in Hz. On larger vehicles the minimum motor frequency is likely to be significantly lower than for smaller vehicles.

Range

Units

20 to 400

hertz

FFT_MAXHZ: Maximum Frequency

Note: This parameter is for advanced users

Upper bound of FFT frequency detection in Hz. On smaller vehicles the maximum motor frequency is likely to be significantly higher than for larger vehicles.

Range

Units

20 to 495

hertz

FFT_SAMPLE_MODE: Sample Mode

Note: This parameter is for advanced users
Note: Reboot required after change

Sampling mode (and therefore rate). 0: Gyro rate sampling, 1: Fast loop rate sampling, 2: Fast loop rate / 2 sampling, 3: Fast loop rate / 3 sampling. Takes effect on reboot.

Range

0 to 4

FFT_WINDOW_SIZE: FFT window size

Note: This parameter is for advanced users
Note: Reboot required after change

Size of window to be used in FFT calculations. Takes effect on reboot. Must be a power of 2 and between 32 and 512. Larger windows give greater frequency resolution but poorer time resolution, consume more CPU time and may not be appropriate for all vehicles. Time and frequency resolution are given by the sample-rate / window-size. Windows of 256 are only really recommended for F7 class boards, windows of 512 or more H7 class.

Range

32 to 1024

FFT_WINDOW_OLAP: FFT window overlap

Note: This parameter is for advanced users
Note: Reboot required after change

Percentage of window to be overlapped before another frame is process. Takes effect on reboot. A good default is 50% overlap. Higher overlap results in more processed frames but not necessarily more temporal resolution. Lower overlap results in lost information at the frame edges.

Range

0 to 0.9

FFT_FREQ_HOVER: FFT learned hover frequency

Note: This parameter is for advanced users

The learned hover noise frequency

Range

0 to 250

FFT_THR_REF: FFT learned thrust reference

Note: This parameter is for advanced users

FFT learned thrust reference for the hover frequency and FFT minimum frequency.

Range

0.01 to 0.9

FFT_SNR_REF: FFT SNR reference threshold

Note: This parameter is for advanced users

FFT SNR reference threshold in dB at which a signal is determined to be present.

Range

0.0 to 100.0

FFT_ATT_REF: FFT attenuation for bandwidth calculation

Note: This parameter is for advanced users

FFT attenuation level in dB for bandwidth calculation and peak detection. The bandwidth is calculated by comparing peak power output with the attenuated version. The default of 15 has shown to be a good compromise in both simulations and real flight.

Range

0 to 100

FFT_BW_HOVER: FFT learned bandwidth at hover

Note: This parameter is for advanced users

FFT learned bandwidth at hover for the attenuation frequencies.

Range

0 to 200

FFT_HMNC_FIT: FFT harmonic fit frequency threshold

Note: This parameter is for advanced users
Note: Reboot required after change

FFT harmonic fit frequency threshold percentage at which a signal of the appropriate frequency is determined to be the harmonic of another. Signals that have a harmonic relationship that varies at most by this percentage are considered harmonics of each other for the purpose of selecting the harmonic notch frequency. If a match is found then the lower frequency harmonic is always used as the basis for the dynamic harmonic notch. A value of zero completely disables harmonic matching.

Range

0 to 100

FFT_HMNC_PEAK: FFT harmonic peak target

Note: This parameter is for advanced users

The FFT harmonic peak target that should be returned by FTN1.PkAvg. The resulting value will be used by the harmonic notch if configured to track the FFT frequency. By default the appropriate peak is auto-detected based on the harmonic fit between peaks and the energy-weighted average frequency on roll on pitch is used. Setting this to 1 will always target the highest energy peak. Setting this to 2 will target the highest energy peak that is lower in frequency than the highest energy peak. Setting this to 3 will target the highest energy peak that is higher in frequency than the highest energy peak. Setting this to 4 will target the highest energy peak on the roll axis only and only the roll frequency will be used (some vehicles have a much more pronounced peak on roll). Setting this to 5 will target the highest energy peak on the pitch axis only and only the pitch frequency will be used (some vehicles have a much more pronounced peak on roll).

Values

Value

Meaning

0

Auto

1

Center Frequency

2

Lower-Shoulder Frequency

3

Upper-Shoulder Frequency

4

Roll-Axis

5

Pitch-Axis

FFT_NUM_FRAMES: FFT output frames to retain and average

Note: This parameter is for advanced users
Note: Reboot required after change

Number of output frequency frames to retain and average in order to calculate final frequencies. Averaging output frames can drastically reduce noise and jitter at the cost of latency as long as the input is stable. The default is to perform no averaging. For rapidly changing frequencies (e.g. smaller aircraft) fewer frames should be averaged.

Range

0 to 8

FFT_OPTIONS: FFT options

Note: This parameter is for advanced users
Note: Reboot required after change

FFT configuration options. Values: 1:Apply the FFT *after* the filter bank,2:Check noise at the motor frequencies using ESC data as a reference

Bitmask

Bit

Meaning

0

Enable post-filter FFT

1

Check motor noise

FHLD Parameters

FHLD_XY_P: FlowHold P gain

Note: This parameter is for advanced users

FlowHold (horizontal) P gain.

Increment

Range

0.1

0.1 to 6.0

FHLD_XY_I: FlowHold I gain

Note: This parameter is for advanced users

FlowHold (horizontal) I gain

Increment

Range

0.01

0.02 to 1.00

FHLD_XY_IMAX: FlowHold Integrator Max

Note: This parameter is for advanced users

FlowHold (horizontal) integrator maximum

Increment

Range

Units

10

0 to 4500

centidegrees

FHLD_XY_FILT_HZ: FlowHold filter on input to control

Note: This parameter is for advanced users

FlowHold (horizontal) filter on input to control

Range

Units

0 to 100

hertz

FHLD_FLOW_MAX: FlowHold Flow Rate Max

Controls maximum apparent flow rate in flowhold

Range

0.1 to 2.5

FHLD_FILT_HZ: FlowHold Filter Frequency

Filter frequency for flow data

Range

Units

1 to 100

hertz

FHLD_QUAL_MIN: FlowHold Flow quality minimum

Minimum flow quality to use flow position hold

Range

0 to 255

FHLD_BRAKE_RATE: FlowHold Braking rate

Controls deceleration rate on stick release

Range

Units

1 to 30

degrees per second

FILT1_ Parameters

FILT1_TYPE: Filter Type

Note: Reboot required after change

Filter Type

Values

Value

Meaning

0

Disable

1

Notch Filter

FILT1_NOTCH_FREQ: Notch Filter center frequency

Note: This parameter is for advanced users

Notch Filter center frequency in Hz.

Range

Units

10 to 495

hertz

FILT1_NOTCH_Q: Notch Filter quality factor

Note: This parameter is for advanced users

Notch Filter quality factor given by the notch centre frequency divided by its bandwidth.

Range

1 to 10

FILT1_NOTCH_ATT: Notch Filter attenuation

Note: This parameter is for advanced users

Notch Filter attenuation in dB.

Range

Units

5 to 50

decibel

FILT2_ Parameters

FILT2_TYPE: Filter Type

Note: Reboot required after change

Filter Type

Values

Value

Meaning

0

Disable

1

Notch Filter

FILT2_NOTCH_FREQ: Notch Filter center frequency

Note: This parameter is for advanced users

Notch Filter center frequency in Hz.

Range

Units

10 to 495

hertz

FILT2_NOTCH_Q: Notch Filter quality factor

Note: This parameter is for advanced users

Notch Filter quality factor given by the notch centre frequency divided by its bandwidth.

Range

1 to 10

FILT2_NOTCH_ATT: Notch Filter attenuation

Note: This parameter is for advanced users

Notch Filter attenuation in dB.

Range

Units

5 to 50

decibel

FILT3_ Parameters

FILT3_TYPE: Filter Type

Note: Reboot required after change

Filter Type

Values

Value

Meaning

0

Disable

1

Notch Filter

FILT3_NOTCH_FREQ: Notch Filter center frequency

Note: This parameter is for advanced users

Notch Filter center frequency in Hz.

Range

Units

10 to 495

hertz

FILT3_NOTCH_Q: Notch Filter quality factor

Note: This parameter is for advanced users

Notch Filter quality factor given by the notch centre frequency divided by its bandwidth.

Range

1 to 10

FILT3_NOTCH_ATT: Notch Filter attenuation

Note: This parameter is for advanced users

Notch Filter attenuation in dB.

Range

Units

5 to 50

decibel

FILT4_ Parameters

FILT4_TYPE: Filter Type

Note: Reboot required after change

Filter Type

Values

Value

Meaning

0

Disable

1

Notch Filter

FILT4_NOTCH_FREQ: Notch Filter center frequency

Note: This parameter is for advanced users

Notch Filter center frequency in Hz.

Range

Units

10 to 495

hertz

FILT4_NOTCH_Q: Notch Filter quality factor

Note: This parameter is for advanced users

Notch Filter quality factor given by the notch centre frequency divided by its bandwidth.

Range

1 to 10

FILT4_NOTCH_ATT: Notch Filter attenuation

Note: This parameter is for advanced users

Notch Filter attenuation in dB.

Range

Units

5 to 50

decibel

FILT5_ Parameters

FILT5_TYPE: Filter Type

Note: Reboot required after change

Filter Type

Values

Value

Meaning

0

Disable

1

Notch Filter

FILT5_NOTCH_FREQ: Notch Filter center frequency

Note: This parameter is for advanced users

Notch Filter center frequency in Hz.

Range

Units

10 to 495

hertz

FILT5_NOTCH_Q: Notch Filter quality factor

Note: This parameter is for advanced users

Notch Filter quality factor given by the notch centre frequency divided by its bandwidth.

Range

1 to 10

FILT5_NOTCH_ATT: Notch Filter attenuation

Note: This parameter is for advanced users

Notch Filter attenuation in dB.

Range

Units

5 to 50

decibel

FILT6_ Parameters

FILT6_TYPE: Filter Type

Note: Reboot required after change

Filter Type

Values

Value

Meaning

0

Disable

1

Notch Filter

FILT6_NOTCH_FREQ: Notch Filter center frequency

Note: This parameter is for advanced users

Notch Filter center frequency in Hz.

Range

Units

10 to 495

hertz

FILT6_NOTCH_Q: Notch Filter quality factor

Note: This parameter is for advanced users

Notch Filter quality factor given by the notch centre frequency divided by its bandwidth.

Range

1 to 10

FILT6_NOTCH_ATT: Notch Filter attenuation

Note: This parameter is for advanced users

Notch Filter attenuation in dB.

Range

Units

5 to 50

decibel

FILT7_ Parameters

FILT7_TYPE: Filter Type

Note: Reboot required after change

Filter Type

Values

Value

Meaning

0

Disable

1

Notch Filter

FILT7_NOTCH_FREQ: Notch Filter center frequency

Note: This parameter is for advanced users

Notch Filter center frequency in Hz.

Range

Units

10 to 495

hertz

FILT7_NOTCH_Q: Notch Filter quality factor

Note: This parameter is for advanced users

Notch Filter quality factor given by the notch centre frequency divided by its bandwidth.

Range

1 to 10

FILT7_NOTCH_ATT: Notch Filter attenuation

Note: This parameter is for advanced users

Notch Filter attenuation in dB.

Range

Units

5 to 50

decibel

FILT8_ Parameters

FILT8_TYPE: Filter Type

Note: Reboot required after change

Filter Type

Values

Value

Meaning

0

Disable

1

Notch Filter

FILT8_NOTCH_FREQ: Notch Filter center frequency

Note: This parameter is for advanced users

Notch Filter center frequency in Hz.

Range

Units

10 to 495

hertz

FILT8_NOTCH_Q: Notch Filter quality factor

Note: This parameter is for advanced users

Notch Filter quality factor given by the notch centre frequency divided by its bandwidth.

Range

1 to 10

FILT8_NOTCH_ATT: Notch Filter attenuation

Note: This parameter is for advanced users

Notch Filter attenuation in dB.

Range

Units

5 to 50

decibel

FLOW Parameters

FLOW_TYPE: Optical flow sensor type

Note: Reboot required after change

Optical flow sensor type

Values

Value

Meaning

0

None

1

PX4Flow

2

Pixart

3

Bebop

4

CXOF

5

MAVLink

6

DroneCAN

7

MSP

8

UPFLOW

FLOW_FXSCALER: X axis optical flow scale factor correction

This sets the parts per thousand scale factor correction applied to the flow sensor X axis optical rate. It can be used to correct for variations in effective focal length. Each positive increment of 1 increases the scale factor applied to the X axis optical flow reading by 0.1%. Negative values reduce the scale factor.

Increment

Range

1

-800 to +800

FLOW_FYSCALER: Y axis optical flow scale factor correction

This sets the parts per thousand scale factor correction applied to the flow sensor Y axis optical rate. It can be used to correct for variations in effective focal length. Each positive increment of 1 increases the scale factor applied to the Y axis optical flow reading by 0.1%. Negative values reduce the scale factor.

Increment

Range

1

-800 to +800

FLOW_ORIENT_YAW: Flow sensor yaw alignment

Specifies the number of centi-degrees that the flow sensor is yawed relative to the vehicle. A sensor with its X-axis pointing to the right of the vehicle X axis has a positive yaw angle.

Increment

Range

Units

10

-17999 to +18000

centidegrees

FLOW_POS_X: X position offset

Note: This parameter is for advanced users

X position of the optical flow sensor focal point in body frame. Positive X is forward of the origin.

Increment

Range

Units

0.01

-5 to 5

meters

FLOW_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the optical flow sensor focal point in body frame. Positive Y is to the right of the origin.

Increment

Range

Units

0.01

-5 to 5

meters

FLOW_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the optical flow sensor focal point in body frame. Positive Z is down from the origin.

Increment

Range

Units

0.01

-5 to 5

meters

FLOW_ADDR: Address on the bus

Note: This parameter is for advanced users

This is used to select between multiple possible I2C addresses for some sensor types. For PX4Flow you can choose 0 to 7 for the 8 possible addresses on the I2C bus.

Range

0 to 127

FLOW_HGT_OVR: Height override of sensor above ground

Note: This parameter is for advanced users

This is used in rover vehicles, where the sensor is a fixed height above the ground

Increment

Range

Units

0.01

0 to 2

meters

FOLL Parameters

FOLL_ENABLE: Follow enable/disable

Enabled/disable following a target

Values

Value

Meaning

0

Disabled

1

Enabled

FOLL_DIST_MAX: Follow distance maximum

Follow distance maximum. targets further than this will be ignored

Range

Units

1 to 1000

meters

FOLL_OFS_TYPE: Follow offset type

Follow offset type

Values

Value

Meaning

0

North-East-Down

1

Relative to lead vehicle heading

FOLL_OFS_X: Follow offsets in meters north/forward

Follow offsets in meters north/forward. If positive, this vehicle fly ahead or north of lead vehicle. Depends on FOLL_OFS_TYPE

Increment

Range

Units

1

-100 to 100

meters

FOLL_OFS_Y: Follow offsets in meters east/right

Follow offsets in meters east/right. If positive, this vehicle will fly to the right or east of lead vehicle. Depends on FOLL_OFS_TYPE

Increment

Range

Units

1

-100 to 100

meters

FOLL_OFS_Z: Follow offsets in meters down

Follow offsets in meters down. If positive, this vehicle will fly below the lead vehicle

Increment

Range

Units

1

-100 to 100

meters

FOLL_YAW_BEHAVE: Follow yaw behaviour

Follow yaw behaviour

Values

Value

Meaning

0

None

1

Face Lead Vehicle

2

Same as Lead vehicle

3

Direction of Flight

FOLL_POS_P: Follow position error P gain

Follow position error P gain. Converts the difference between desired vertical speed and actual speed into a desired acceleration that is passed to the throttle acceleration controller

Increment

Range

0.01

0.01 to 1.00

FOLL_ALT_TYPE: Follow altitude type

Follow altitude type

Values

Value

Meaning

0

absolute

1

relative

FOLL_OPTIONS: Follow options

Follow options bitmask

Values

Value

Meaning

0

None

1

Mount Follows lead vehicle on mode enter

FRSKY_ Parameters

FRSKY_OPTIONS: FRSky Telemetry Options

A bitmask to set some FRSky Telemetry specific options

Bitmask

Bit

Meaning

0

EnableAirspeedAndGroundspeed

GEN_ Parameters

GEN_TYPE: Generator type

Note: Reboot required after change

Generator type

Values

Value

Meaning

0

Disabled

1

IE 650w 800w Fuel Cell

2

IE 2.4kW Fuel Cell

3

Richenpower

GEN_OPTIONS: Generator Options

Bitmask of options for generators

Bitmask

Bit

Meaning

0

Suppress Maintenance-Required Warnings

GPS Parameters

GPS_NAVFILTER: Navigation filter setting

Note: This parameter is for advanced users

Navigation filter engine setting

Values

Value

Meaning

0

Portable

2

Stationary

3

Pedestrian

4

Automotive

5

Sea

6

Airborne1G

7

Airborne2G

8

Airborne4G

GPS_AUTO_SWITCH: Automatic Switchover Setting

Note: This parameter is for advanced users

Automatic switchover to GPS reporting best lock, 1:UseBest selects the GPS with highest status, if both are equal the GPS with highest satellite count is used 4:Use primary if 3D fix or better, will revert to 'UseBest' behaviour if 3D fix is lost on primary

Values

Value

Meaning

0

Use primary

1

UseBest

2

Blend

4

Use primary if 3D fix or better

GPS_SBAS_MODE: SBAS Mode

Note: This parameter is for advanced users

This sets the SBAS (satellite based augmentation system) mode if available on this GPS. If set to 2 then the SBAS mode is not changed in the GPS. Otherwise the GPS will be reconfigured to enable/disable SBAS. Disabling SBAS may be worthwhile in some parts of the world where an SBAS signal is available but the baseline is too long to be useful.

Values

Value

Meaning

0

Disabled

1

Enabled

2

NoChange

GPS_MIN_ELEV: Minimum elevation

Note: This parameter is for advanced users

This sets the minimum elevation of satellites above the horizon for them to be used for navigation. Setting this to -100 leaves the minimum elevation set to the GPS modules default.

Range

Units

-100 to 90

degrees

GPS_SBP_LOGMASK: Swift Binary Protocol Logging Mask

Note: This parameter is for advanced users

Masked with the SBP msg_type field to determine whether SBR1/SBR2 data is logged

Values

Value

Meaning

0

None (0x0000)

-1

All (0xFFFF)

-256

External only (0xFF00)

GPS_RAW_DATA: Raw data logging

Note: This parameter is for advanced users
Note: Reboot required after change

Handles logging raw data; on uBlox chips that support raw data this will log RXM messages into logger; on Septentrio this will log on the equipment's SD card and when set to 2, the autopilot will try to stop logging after disarming and restart after arming

Values

Value

Meaning

0

Ignore

1

Always log

2

Stop logging when disarmed (SBF only)

5

Only log every five samples (uBlox only)

GPS_SAVE_CFG: Save GPS configuration

Note: This parameter is for advanced users

Determines whether the configuration for this GPS should be written to non-volatile memory on the GPS. Currently working for UBlox 6 series and above.

Values

Value

Meaning

0

Do not save config

1

Save config

2

Save only when needed

GPS_AUTO_CONFIG: Automatic GPS configuration

Note: This parameter is for advanced users

Controls if the autopilot should automatically configure the GPS based on the parameters and default settings

Values

Value

Meaning

0

Disables automatic configuration

1

Enable automatic configuration for Serial GPSes only

2

Enable automatic configuration for DroneCAN as well

GPS_BLEND_MASK: Multi GPS Blending Mask

Note: This parameter is for advanced users

Determines which of the accuracy measures Horizontal position, Vertical Position and Speed are used to calculate the weighting on each GPS receiver when soft switching has been selected by setting GPS_AUTO_SWITCH to 2(Blend)

Bitmask

Bit

Meaning

0

Horiz Pos

1

Vert Pos

2

Speed

GPS_DRV_OPTIONS: driver options

Note: This parameter is for advanced users

Additional backend specific options

Bitmask

Bit

Meaning

0

Use UART2 for moving baseline on ublox

1

Use base station for GPS yaw on SBF

2

Use baudrate 115200

3

Use dedicated CAN port b/w GPSes for moving baseline

4

Use ellipsoid height instead of AMSL

5

Override GPS satellite health of L5 band from L1 health

6

Enable RTCM full parse even for a single channel

7

Disable automatic full RTCM parsing when RTCM seen on more than one channel

GPS_PRIMARY: Primary GPS

Note: This parameter is for advanced users

This GPS will be used when GPS_AUTO_SWITCH is 0 and used preferentially with GPS_AUTO_SWITCH = 4.

Increment

Values

1

Value

Meaning

0

FirstGPS

1

SecondGPS

GPS1_ Parameters

GPS1_TYPE: GPS type

Note: This parameter is for advanced users
Note: Reboot required after change

GPS type

Values

Value

Meaning

0

None

1

AUTO

2

uBlox

5

NMEA

6

SiRF

7

HIL

8

SwiftNav

9

DroneCAN

10

Septentrio(SBF)

11

Trimble(GSOF)

13

ERB

14

MAVLink

15

NOVA

16

HemisphereNMEA

17

uBlox-MovingBaseline-Base

18

uBlox-MovingBaseline-Rover

19

MSP

20

AllyStar

21

ExternalAHRS

22

DroneCAN-MovingBaseline-Base

23

DroneCAN-MovingBaseline-Rover

24

UnicoreNMEA

25

UnicoreMovingBaselineNMEA

26

Septentrio-DualAntenna(SBF)

GPS1_GNSS_MODE: GNSS system configuration

Note: This parameter is for advanced users

Bitmask for what GNSS system to use on the first GPS (all unchecked or zero to leave GPS as configured)

Bitmask

Bit

Meaning

0

GPS

1

SBAS

2

Galileo

3

Beidou

4

IMES

5

QZSS

6

GLONASS

GPS1_RATE_MS: GPS update rate in milliseconds

Note: This parameter is for advanced users

Controls how often the GPS should provide a position update. Lowering below 5Hz(default) is not allowed. Raising the rate above 5Hz usually provides little benefit and for some GPS (eg Ublox M9N) can severely impact performance.

Range

Units

Values

50 to 200

milliseconds

Value

Meaning

100

10Hz

125

8Hz

200

5Hz

GPS1_POS_X: Antenna X position offset

Note: This parameter is for advanced users

X position of the first GPS antenna in body frame. Positive X is forward of the origin. Use antenna phase centroid location if provided by the manufacturer.

Increment

Range

Units

0.01

-5 to 5

meters

GPS1_POS_Y: Antenna Y position offset

Note: This parameter is for advanced users

Y position of the first GPS antenna in body frame. Positive Y is to the right of the origin. Use antenna phase centroid location if provided by the manufacturer.

Increment

Range

Units

0.01

-5 to 5

meters

GPS1_POS_Z: Antenna Z position offset

Note: This parameter is for advanced users

Z position of the first GPS antenna in body frame. Positive Z is down from the origin. Use antenna phase centroid location if provided by the manufacturer.

Increment

Range

Units

0.01

-5 to 5

meters

GPS1_DELAY_MS: GPS delay in milliseconds

Note: This parameter is for advanced users
Note: Reboot required after change

Controls the amount of GPS measurement delay that the autopilot compensates for. Set to zero to use the default delay for the detected GPS type.

Range

Units

0 to 250

milliseconds

GPS1_COM_PORT: GPS physical COM port

Note: This parameter is for advanced users
Note: Reboot required after change

The physical COM port on the connected device, currently only applies to SBF and GSOF GPS

Increment

Range

Values

1

0 to 10

Value

Meaning

0

COM1(RS232) on GSOF

1

COM2(TTL) on GSOF

GPS1_CAN_NODEID: Detected CAN Node ID for GPS

Note: This parameter is for advanced users

GPS Node id for GPS. Detected node unless CAN_OVRIDE is set

ReadOnly

True

GPS1_CAN_OVRIDE: DroneCAN GPS NODE ID

Note: This parameter is for advanced users

GPS Node id for GPS. If 0 the gps will be automatically selected on a first-come-first-GPS basis.

GPS1_MB_ Parameters

GPS1_MB_TYPE: Moving base type

Note: This parameter is for advanced users
Note: Reboot required after change

Controls the type of moving base used if using moving base.This is renamed in 4.6 and later to GPSx_MB_TYPE.

Values

Value

Meaning

0

Relative to alternate GPS instance

1

RelativeToCustomBase

GPS1_MB_OFS_X: Base antenna X position offset

Note: This parameter is for advanced users

X position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive X is forward of the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_X.

Increment

Range

Units

0.01

-5 to 5

meters

GPS1_MB_OFS_Y: Base antenna Y position offset

Note: This parameter is for advanced users

Y position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive Y is to the right of the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_Y.

Increment

Range

Units

0.01

-5 to 5

meters

GPS1_MB_OFS_Z: Base antenna Z position offset

Note: This parameter is for advanced users

Z position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive Z is down from the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_Z.

Increment

Range

Units

0.01

-5 to 5

meters

GPS2_ Parameters

GPS2_TYPE: GPS type

Note: This parameter is for advanced users
Note: Reboot required after change

GPS type

Values

Value

Meaning

0

None

1

AUTO

2

uBlox

5

NMEA

6

SiRF

7

HIL

8

SwiftNav

9

DroneCAN

10

Septentrio(SBF)

11

Trimble(GSOF)

13

ERB

14

MAVLink

15

NOVA

16

HemisphereNMEA

17

uBlox-MovingBaseline-Base

18

uBlox-MovingBaseline-Rover

19

MSP

20

AllyStar

21

ExternalAHRS

22

DroneCAN-MovingBaseline-Base

23

DroneCAN-MovingBaseline-Rover

24

UnicoreNMEA

25

UnicoreMovingBaselineNMEA

26

Septentrio-DualAntenna(SBF)

GPS2_GNSS_MODE: GNSS system configuration

Note: This parameter is for advanced users

Bitmask for what GNSS system to use on the first GPS (all unchecked or zero to leave GPS as configured)

Bitmask

Bit

Meaning

0

GPS

1

SBAS

2

Galileo

3

Beidou

4

IMES

5

QZSS

6

GLONASS

GPS2_RATE_MS: GPS update rate in milliseconds

Note: This parameter is for advanced users

Controls how often the GPS should provide a position update. Lowering below 5Hz(default) is not allowed. Raising the rate above 5Hz usually provides little benefit and for some GPS (eg Ublox M9N) can severely impact performance.

Range

Units

Values

50 to 200

milliseconds

Value

Meaning

100

10Hz

125

8Hz

200

5Hz

GPS2_POS_X: Antenna X position offset

Note: This parameter is for advanced users

X position of the first GPS antenna in body frame. Positive X is forward of the origin. Use antenna phase centroid location if provided by the manufacturer.

Increment

Range

Units

0.01

-5 to 5

meters

GPS2_POS_Y: Antenna Y position offset

Note: This parameter is for advanced users

Y position of the first GPS antenna in body frame. Positive Y is to the right of the origin. Use antenna phase centroid location if provided by the manufacturer.

Increment

Range

Units

0.01

-5 to 5

meters

GPS2_POS_Z: Antenna Z position offset

Note: This parameter is for advanced users

Z position of the first GPS antenna in body frame. Positive Z is down from the origin. Use antenna phase centroid location if provided by the manufacturer.

Increment

Range

Units

0.01

-5 to 5

meters

GPS2_DELAY_MS: GPS delay in milliseconds

Note: This parameter is for advanced users
Note: Reboot required after change

Controls the amount of GPS measurement delay that the autopilot compensates for. Set to zero to use the default delay for the detected GPS type.

Range

Units

0 to 250

milliseconds

GPS2_COM_PORT: GPS physical COM port

Note: This parameter is for advanced users
Note: Reboot required after change

The physical COM port on the connected device, currently only applies to SBF and GSOF GPS

Increment

Range

Values

1

0 to 10

Value

Meaning

0

COM1(RS232) on GSOF

1

COM2(TTL) on GSOF

GPS2_CAN_NODEID: Detected CAN Node ID for GPS

Note: This parameter is for advanced users

GPS Node id for GPS. Detected node unless CAN_OVRIDE is set

ReadOnly

True

GPS2_CAN_OVRIDE: DroneCAN GPS NODE ID

Note: This parameter is for advanced users

GPS Node id for GPS. If 0 the gps will be automatically selected on a first-come-first-GPS basis.

GPS2_MB_ Parameters

GPS2_MB_TYPE: Moving base type

Note: This parameter is for advanced users
Note: Reboot required after change

Controls the type of moving base used if using moving base.This is renamed in 4.6 and later to GPSx_MB_TYPE.

Values

Value

Meaning

0

Relative to alternate GPS instance

1

RelativeToCustomBase

GPS2_MB_OFS_X: Base antenna X position offset

Note: This parameter is for advanced users

X position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive X is forward of the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_X.

Increment

Range

Units

0.01

-5 to 5

meters

GPS2_MB_OFS_Y: Base antenna Y position offset

Note: This parameter is for advanced users

Y position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive Y is to the right of the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_Y.

Increment

Range

Units

0.01

-5 to 5

meters

GPS2_MB_OFS_Z: Base antenna Z position offset

Note: This parameter is for advanced users

Z position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive Z is down from the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_Z.

Increment

Range

Units

0.01

-5 to 5

meters

GPS_MB1_ Parameters

GPS_MB1_TYPE: Moving base type

Note: This parameter is for advanced users
Note: Reboot required after change

Controls the type of moving base used if using moving base.This is renamed in 4.6 and later to GPSx_MB_TYPE.

Values

Value

Meaning

0

Relative to alternate GPS instance

1

RelativeToCustomBase

GPS_MB1_OFS_X: Base antenna X position offset

Note: This parameter is for advanced users

X position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive X is forward of the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_X.

Increment

Range

Units

0.01

-5 to 5

meters

GPS_MB1_OFS_Y: Base antenna Y position offset

Note: This parameter is for advanced users

Y position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive Y is to the right of the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_Y.

Increment

Range

Units

0.01

-5 to 5

meters

GPS_MB1_OFS_Z: Base antenna Z position offset

Note: This parameter is for advanced users

Z position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive Z is down from the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_Z.

Increment

Range

Units

0.01

-5 to 5

meters

GPS_MB2_ Parameters

GPS_MB2_TYPE: Moving base type

Note: This parameter is for advanced users
Note: Reboot required after change

Controls the type of moving base used if using moving base.This is renamed in 4.6 and later to GPSx_MB_TYPE.

Values

Value

Meaning

0

Relative to alternate GPS instance

1

RelativeToCustomBase

GPS_MB2_OFS_X: Base antenna X position offset

Note: This parameter is for advanced users

X position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive X is forward of the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_X.

Increment

Range

Units

0.01

-5 to 5

meters

GPS_MB2_OFS_Y: Base antenna Y position offset

Note: This parameter is for advanced users

Y position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive Y is to the right of the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_Y.

Increment

Range

Units

0.01

-5 to 5

meters

GPS_MB2_OFS_Z: Base antenna Z position offset

Note: This parameter is for advanced users

Z position of the base (primary) GPS antenna in body frame from the position of the 2nd antenna. Positive Z is down from the 2nd antenna. Use antenna phase centroid location if provided by the manufacturer.This is renamed in 4.6 and later to GPSx_MB_OFS_Z.

Increment

Range

Units

0.01

-5 to 5

meters

GRIP_ Parameters

GRIP_ENABLE: Gripper Enable/Disable

Gripper enable/disable

Values

Value

Meaning

0

Disabled

1

Enabled

GRIP_TYPE: Gripper Type

Gripper enable/disable

Values

Value

Meaning

0

None

1

Servo

2

EPM

GRIP_GRAB: Gripper Grab PWM

Note: This parameter is for advanced users

PWM value in microseconds sent to Gripper to initiate grabbing the cargo

Range

Units

1000 to 2000

PWM in microseconds

GRIP_RELEASE: Gripper Release PWM

Note: This parameter is for advanced users

PWM value in microseconds sent to Gripper to release the cargo

Range

Units

1000 to 2000

PWM in microseconds

GRIP_NEUTRAL: Neutral PWM

Note: This parameter is for advanced users

PWM value in microseconds sent to grabber when not grabbing or releasing

Range

Units

1000 to 2000

PWM in microseconds

GRIP_REGRAB: EPM Gripper Regrab interval

Note: This parameter is for advanced users

Time in seconds that EPM gripper will regrab the cargo to ensure grip has not weakened; 0 to disable

Range

Units

0 to 255

seconds

GRIP_CAN_ID: EPM UAVCAN Hardpoint ID

Refer to https://docs.zubax.com/opengrab_epm_v3#UAVCAN_interface

Range

0 to 255

GRIP_AUTOCLOSE: Gripper Autoclose time

Note: This parameter is for advanced users

Time in seconds that gripper close the gripper after opening; 0 to disable

Range

Units

0.25 to 255

seconds

H_ Parameters

H_TAIL_TYPE: Tail Type

Tail type selection. Servo Only uses tail rotor pitch to provide yaw control (including stabilization) via an output assigned to Motor4. Servo with External Gyro uses an external gyro to control tail rotor pitch via a servo. Yaw control without stabilization is passed to the external gyro via the output assigned to Motor4. Direct Drive Variable Pitch(DDVP) is used for tails that have a motor whose ESC is connected to an output with function HeliTailRSC. Tail pitch is still accomplished with a servo on an output assigned to Motor4 function. Direct Drive Fixed Pitch (DDFP) CW is used for helicopters with a rotor that spins clockwise when viewed from above with a motor whose ESC is controlled by an output whose function is Motor4. Direct Drive Fixed Pitch (DDFP) CCW is used for helicopters with a rotor that spins counter clockwise when viewed from above with a motor whose ESC is controlled by an output whose function is Motor4. In both DDFP cases, no servo is used for the tail and the tail motor esc on Motor4 output is used to control the yaw axis using motor speed.

Values

Value

Meaning

0

Servo only

1

Servo with ExtGyro

2

DirectDrive VarPitch

3

DirectDrive FixedPitch CW

4

DirectDrive FixedPitch CCW

H_GYR_GAIN: External Gyro Gain

PWM in microseconds sent to external gyro on an servo/output whose function is Motor7 when tail type is Servo w/ ExtGyro

Increment

Range

Units

1

0 to 1000

PWM in microseconds

H_FLYBAR_MODE: Flybar Mode Selector

Flybar present or not. Affects attitude controller used during ACRO flight mode

Values

Value

Meaning

0

NoFlybar

1

Flybar

H_TAIL_SPEED: DDVP Tail ESC speed

Direct drive, variable pitch tail ESC speed in percent output to the tail motor esc (HeliTailRSC Servo) when motor interlock enabled (throttle hold off) and speed fully ramped up after spoolup.

Increment

Range

Units

1

0 to 100

percent

H_GYR_GAIN_ACRO: ACRO External Gyro Gain

PWM in microseconds sent to external gyro on an servo/output whose function is Motor7 when tail type is Servo w/ ExtGyro in mode ACRO instead of H_GYR_GAIN. A value of zero means to use H_GYR_GAIN

Increment

Range

Units

1

0 to 1000

PWM in microseconds

H_SW_TYPE (AP_MotorsHeli_Single): Swashplate Type

H3 is generic, three-servo only. H3_120/H3_140 plates have Motor1 left side, Motor2 right side, Motor3 elevator in rear. HR3_120/HR3_140 have Motor1 right side, Motor2 left side, Motor3 elevator in front - use H3_120/H3_140 and reverse servo and collective directions as necessary. For all H3_90 swashplates use H4_90 and don't use servo output for the missing servo. For H4-90 Motors1&2 are left/right respectively, Motors3&4 are rear/front respectively. For H4-45 Motors1&2 are LF/RF, Motors3&4 are LR/RR

Values

Value

Meaning

0

H3 Generic

1

H1 non-CPPM

2

H3_140

3

H3_120

4

H4_90

5

H4_45

H_SW_COL_DIR (AP_MotorsHeli_Single): Collective Direction

Direction collective moves for positive pitch. 0 for Normal, 1 for Reversed

Values

Value

Meaning

0

Normal

1

Reversed

H_SW_LIN_SVO (AP_MotorsHeli_Single): Linearize Swash Servos

This linearizes the swashplate servo's mechanical output to account for nonlinear output due to arm rotation. This requires a specific setup procedure to work properly. The servo arm must be centered on the mechanical throw at the servo trim position and the servo trim position kept as close to 1500 as possible. Leveling the swashplate can only be done through the pitch links. See the ardupilot wiki for more details on setup.

Values

Value

Meaning

0

Disabled

1

Enabled

H_SW_H3_ENABLE (AP_MotorsHeli_Single): H3 Generic Enable

Note: This parameter is for advanced users

Automatically set when H3 generic swash type is selected for swashplate. Do not set manually.

Values

Value

Meaning

0

Disabled

1

Enabled

H_SW_H3_SV1_POS (AP_MotorsHeli_Single): H3 Generic Servo 1 Position

Note: This parameter is for advanced users

Azimuth position on swashplate for servo 1 with the front of the heli being 0 deg

Range

Units

-180 to 180

degrees

H_SW_H3_SV2_POS (AP_MotorsHeli_Single): H3 Generic Servo 2 Position

Note: This parameter is for advanced users

Azimuth position on swashplate for servo 2 with the front of the heli being 0 deg

Range

Units

-180 to 180

degrees

H_SW_H3_SV3_POS (AP_MotorsHeli_Single): H3 Generic Servo 3 Position

Note: This parameter is for advanced users

Azimuth position on swashplate for servo 3 with the front of the heli being 0 deg

Range

Units

-180 to 180

degrees

H_SW_H3_PHANG (AP_MotorsHeli_Single): H3 Generic Phase Angle Comp

Note: This parameter is for advanced users

Only for H3 swashplate. If pitching the swash forward induces a roll, this can be correct the problem

Increment

Range

Units

1

-30 to 30

degrees

H_COL2YAW: Collective-Yaw Mixing

Feed-forward compensation to automatically add rudder input when collective pitch is increased. Can be positive or negative depending on mechanics.

Increment

Range

0.1

-2 to 2

H_DDFP_THST_EXPO: DDFP Tail Rotor Thrust Curve Expo

Tail rotor DDFP motor thrust curve exponent (0.0 for linear to 1.0 for second order curve)

Range

-1 to 1

H_DDFP_SPIN_MIN: DDFP Tail Rotor Motor Spin minimum

Point at which the thrust starts expressed as a number from 0 to 1 in the entire output range.

Values

Value

Meaning

0.0

Low

0.15

Default

0.3

High

H_DDFP_SPIN_MAX: DDFP Tail Rotor Motor Spin maximum

Point at which the thrust saturates expressed as a number from 0 to 1 in the entire output range

Values

Value

Meaning

0.9

Low

0.95

Default

1.0

High

H_DDFP_BAT_IDX: DDFP Tail Rotor Battery compensation index

Which battery monitor should be used for doing compensation

Values

Value

Meaning

0

First battery

1

Second battery

H_DDFP_BAT_V_MAX: Battery voltage compensation maximum voltage

Battery voltage compensation maximum voltage (voltage above this will have no additional scaling effect on thrust). Recommend 4.2 * cell count, 0 = Disabled

Range

Units

6 to 53

volt

H_DDFP_BAT_V_MIN: Battery voltage compensation minimum voltage

Battery voltage compensation minimum voltage (voltage below this will have no additional scaling effect on thrust). Recommend 3.3 * cell count, 0 = Disabled

Range

Units

6 to 42

volt

H_YAW_TRIM: Tail Rotor Trim

Fixed offset applied to yaw output to minimize yaw I-term contribution needed to counter rotor drag. Currently only works of DDFP tails (H_TAIL_TYPE = 3 or H_TAIL_TYPE = 4). If using the H_COL2YAW compensation this trim is used to compensate for the main rotor profile drag. If H_COL2YAW is not used, this value can be set to reduce the yaw I contribution to zero when in a steady hover.

Range

0 to 1

H_DUAL_MODE: Dual Mode

Sets the dual mode of the heli, either as tandem, transverse, or intermeshing/coaxial.

Values

Value

Meaning

0

Longitudinal

1

Transverse

2

Intermeshing/Coaxial

H_DCP_SCALER: Differential-Collective-Pitch Scaler

Scaling factor applied to the differential-collective-pitch

Range

0 to 1

H_DCP_YAW: Differential-Collective-Pitch Yaw Mixing

Feed-forward compensation to automatically add yaw input when differential collective pitch is applied. Disabled for intermeshing mode.

Increment

Range

0.1

-10 to 10

H_YAW_SCALER: Scaler for yaw mixing

Scaler for mixing yaw into roll or pitch.

Increment

Range

0.1

-10 to 10

H_COL2_MIN: Swash 2 Minimum Collective Pitch

Lowest possible servo position in PWM microseconds for swashplate 2

Increment

Range

Units

1

1000 to 2000

PWM in microseconds

H_COL2_MAX: Swash 2 Maximum Collective Pitch

Highest possible servo position in PWM microseconds for swashplate 2

Increment

Range

Units

1

1000 to 2000

PWM in microseconds

H_SW_TYPE (AP_MotorsHeli_Dual): Swash 1 Type

H3 is generic, three-servo only. H3_120/H3_140 plates have Motor1 left side, Motor2 right side, Motor3 elevator in rear. HR3_120/HR3_140 have Motor1 right side, Motor2 left side, Motor3 elevator in front - use H3_120/H3_140 and reverse servo and collective directions as necessary. For all H3_90 swashplates use H4_90 and don't use servo output for the missing servo. For H4-90 Motors1&2 are left/right respectively, Motors3&4 are rear/front respectively. For H4-45 Motors1&2 are LF/RF, Motors3&4 are LR/RR

Values

Value

Meaning

0

H3 Generic

1

H1 non-CPPM

2

H3_140

3

H3_120

4

H4_90

5

H4_45

H_SW_COL_DIR (AP_MotorsHeli_Dual): Swash 1 Collective Direction

Direction collective moves for positive pitch. 0 for Normal, 1 for Reversed

Values

Value

Meaning

0

Normal

1

Reversed

H_SW_LIN_SVO (AP_MotorsHeli_Dual): Linearize Swash 1 Servos

This linearizes the swashplate 1 servo's mechanical output to account for nonlinear output due to arm rotation. This requires a specific setup procedure to work properly. The servo arm must be centered on the mechanical throw at the servo trim position and the servo trim position kept as close to 1500 as possible. Leveling the swashplate can only be done through the pitch links. See the ardupilot wiki for more details on setup.

Values

Value

Meaning

0

Disabled

1

Enabled

H_SW_H3_ENABLE (AP_MotorsHeli_Dual): Swash 1 H3 Generic Enable

Note: This parameter is for advanced users

Automatically set when H3 generic swash type is selected for swashplate 1. Do not set manually.

Values

Value

Meaning

0

Disabled

1

Enabled

H_SW_H3_SV1_POS (AP_MotorsHeli_Dual): Swash 1 H3 Generic Servo 1 Position

Note: This parameter is for advanced users

Azimuth position on swashplate for servo 1 with the front of the heli being 0 deg

Range

Units

-180 to 180

degrees

H_SW_H3_SV2_POS (AP_MotorsHeli_Dual): Swash 1 H3 Generic Servo 2 Position

Note: This parameter is for advanced users

Azimuth position on swashplate 1 for servo 2 with the front of the heli being 0 deg

Range

Units

-180 to 180

degrees

H_SW_H3_SV3_POS (AP_MotorsHeli_Dual): Swash 1 H3 Generic Servo 3 Position

Note: This parameter is for advanced users

Azimuth position on swashplate 1 for servo 3 with the front of the heli being 0 deg

Range

Units

-180 to 180

degrees

H_SW_H3_PHANG (AP_MotorsHeli_Dual): Swash 1 H3 Generic Phase Angle Comp

Note: This parameter is for advanced users

Only for H3 swashplate. If pitching the swash forward induces a roll, this can be correct the problem

Increment

Range

Units

1

-30 to 30

degrees

H_SW2_TYPE: Swash 2 Type

H3 is generic, three-servo only. H3_120/H3_140 plates have Motor1 left side, Motor2 right side, Motor3 elevator in rear. HR3_120/HR3_140 have Motor1 right side, Motor2 left side, Motor3 elevator in front - use H3_120/H3_140 and reverse servo and collective directions as necessary. For all H3_90 swashplates use H4_90 and don't use servo output for the missing servo. For H4-90 Motors1&2 are left/right respectively, Motors3&4 are rear/front respectively. For H4-45 Motors1&2 are LF/RF, Motors3&4 are LR/RR

Values

Value

Meaning

0

H3 Generic

1

H1 non-CPPM

2

H3_140

3

H3_120

4

H4_90

5

H4_45

H_SW2_COL_DIR: Swash 2 Collective Direction

Direction collective moves for positive pitch. 0 for Normal, 1 for Reversed

Values

Value

Meaning

0

Normal

1

Reversed

H_SW2_LIN_SVO: Linearize Swash 2 Servos

This linearizes the swashplate 2 servo's mechanical output to account for nonlinear output due to arm rotation. This requires a specific setup procedure to work properly. The servo arm must be centered on the mechanical throw at the servo trim position and the servo trim position kept as close to 1500 as possible. Leveling the swashplate can only be done through the pitch links. See the ardupilot wiki for more details on setup.

Values

Value

Meaning

0

Disabled

1

Enabled

H_SW2_H3_ENABLE: Swash 2 H3 Generic Enable

Note: This parameter is for advanced users

Automatically set when H3 generic swash type is selected for swashplate 2. Do not set manually.

Values

Value

Meaning

0

Disabled

1

Enabled

H_SW2_H3_SV1_POS: Swash 2 H3 Generic Servo 1 Position

Note: This parameter is for advanced users

Azimuth position on swashplate for servo 1 with the front of the heli being 0 deg

Range

Units

-180 to 180

degrees

H_SW2_H3_SV2_POS: Swash 2 H3 Generic Servo 2 Position

Note: This parameter is for advanced users

Azimuth position on swashplate 2 for servo 2 with the front of the heli being 0 deg

Range

Units

-180 to 180

degrees

H_SW2_H3_SV3_POS: Swash 2 H3 Generic Servo 3 Position

Note: This parameter is for advanced users

Azimuth position on swashplate 2 for servo 3 with the front of the heli being 0 deg

Range

Units

-180 to 180

degrees

H_SW2_H3_PHANG: Swash 2 H3 Generic Phase Angle Comp

Note: This parameter is for advanced users

Only for H3 swashplate. If pitching the swash forward induces a roll, this can be correct the problem

Increment

Range

Units

1

-30 to 30

degrees

H_DCP_TRIM: Differential Collective Pitch Trim

Removes I term bias due to center of gravity offsets or discrepancies between rotors in swashplate setup. If DCP axis has I term bias while hovering in calm winds, use value of bias in DCP_TRIM to re-center I term.

Increment

Range

0.01

-0.2 to 0.2

H_YAW_REV_EXPO: Yaw reverser expo

For intermeshing mode only. Yaw revereser smoothing exponent, smoothen transition near zero collective region. Increase this parameter to shink smoothing range. Set to -1 to disable reverser.

Increment

Range

1.0

-1 to 1000

H_COL_MIN: Minimum Collective Pitch

Lowest possible servo position in PWM microseconds for the swashplate

Increment

Range

Units

1

1000 to 2000

PWM in microseconds

H_COL_MAX: Maximum Collective Pitch

Highest possible servo position in PWM microseconds for the swashplate

Increment

Range

Units

1

1000 to 2000

PWM in microseconds

H_SV_MAN: Manual Servo Mode

Manual servo override for swash set-up. Must be 0 (Disabled) for flight!

Values

Value

Meaning

0

Disabled

1

Passthrough

2

Max collective

3

Zero thrust collective

4

Min collective

H_CYC_MAX: Maximum Cyclic Pitch Angle

Maximum cyclic pitch angle of the swash plate. There are no units to this parameter. This should be adjusted to get the desired cyclic blade pitch for the pitch and roll axes. Typically this should be 6-7 deg (measured blade pitch angle difference between stick centered and stick max deflection.

Increment

Range

100

0 to 4500

H_SV_TEST: Boot-up Servo Test Cycles

Number of cycles to run servo test on boot-up

Increment

Range

1

0 to 10

H_COL_HOVER: Collective Hover Value

Note: This parameter is for advanced users

Collective needed to hover expressed as a number from 0 to 1 where 0 is H_COL_MIN and 1 is H_COL_MAX

Range

0.3 to 0.8

H_HOVER_LEARN: Hover Value Learning

Note: This parameter is for advanced users

Enable/Disable automatic learning of hover collective

Values

Value

Meaning

0

Disabled

1

Learn

2

Learn and Save

H_OPTIONS: Heli_Options

Bitmask of heli options. Bit 0 changes how the pitch, roll, and yaw axis integrator term is managed for low speed and takeoff/landing. In AC 4.0 and earlier, scheme uses a leaky integrator for ground speeds less than 5 m/s and won't let the steady state integrator build above ILMI. The integrator is allowed to build to the ILMI value when it is landed. The other integrator management scheme bases integrator limiting on takeoff and landing. Whenever the aircraft is landed the integrator is set to zero. When the aicraft is airborne, the integrator is only limited by IMAX.

Bitmask

Bit

Meaning

0

Use Leaky I

H_COL_ANG_MIN: Collective Blade Pitch Angle Minimum

Minimum collective blade pitch angle in deg that corresponds to the PWM set for minimum collective pitch (H_COL_MIN).

Increment

Range

Units

0.1

-20 to 0

degrees

H_COL_ANG_MAX: Collective Blade Pitch Angle Maximum

Maximum collective blade pitch angle in deg that corresponds to the PWM set for maximum collective pitch (H_COL_MAX).

Increment

Range

Units

0.1

5 to 20

degrees

H_COL_ZERO_THRST: Collective Blade Pitch at Zero Thrust

Collective blade pitch angle at zero thrust in degrees. For symetric airfoil blades this value is zero deg. For chambered airfoil blades this value is typically negative.

Increment

Range

Units

0.1

-5 to 0

degrees

H_COL_LAND_MIN: Collective Blade Pitch Minimum when Landed

Minimum collective blade pitch angle when landed in degrees for non-manual collective modes (i.e. modes that use altitude hold).

Increment

Range

Units

0.1

-5 to 0

degrees

H_RSC_ Parameters

H_RSC_SETPOINT: External Motor Governor Setpoint

Throttle (HeliRSC Servo) output in percent to the external motor governor when motor interlock enabled (throttle hold off).

Increment

Range

Units

1

0 to 100

percent

H_RSC_MODE: Rotor Speed Control Mode

Selects the type of rotor speed control used to determine throttle output to the HeliRSC servo channel when motor interlock is enabled (throttle hold off). RC Passthrough sends the input from the RC Motor Interlock channel as throttle output. External Gov SetPoint sends the RSC SetPoint parameter value as throttle output. Throttle Curve uses the 5 point throttle curve to determine throttle output based on the collective output. AutoThrottle requires a rotor speed sensor, contains an advanced autothrottle governor and is primarily for piston and turbine engines. WARNING: Throttle ramp time and throttle curve MUST be tuned properly using Throttle Curve mode before using AutoThrottle

Values

Value

Meaning

1

RC Passthrough

2

External Gov SetPoint

3

Throttle Curve

4

AutoThrottle

H_RSC_RAMP_TIME: Throttle Ramp Time

Time in seconds for throttle output (HeliRSC servo) to ramp from ground idle (RSC_IDLE) to flight idle throttle setting when motor interlock is enabled (throttle hold off).

Range

Units

0 to 60

seconds

H_RSC_RUNUP_TIME: Rotor Runup Time

Actual time in seconds for the main rotor to reach full speed after motor interlock is enabled (throttle hold off). Must be at least one second longer than the Throttle Ramp Time that is set with RSC_RAMP_TIME. WARNING: For AutoThrottle users with piston and turbine engines it is VERY important to know how long it takes to warm up your engine and reach full rotor speed when throttle switch is turned ON. This timer should be set for at least the amount of time it takes to get your helicopter to full flight power, ready for takeoff. Failure to heed this warning could result in the auto-takeoff mode attempting to lift up into hover before the engine has reached full power, and subsequent loss of control

Range

Units

0 to 60

seconds

H_RSC_CRITICAL: Critical Rotor Speed

Percentage of normal rotor speed where flight is no longer possible. However currently the rotor runup/rundown is estimated using the RSC_RUNUP_TIME parameter. Estimated rotor speed increases/decreases between 0 (rotor stopped) to 1 (rotor at normal speed) in the RSC_RUNUP_TIME in seconds. This parameter should be set so that the estimated rotor speed goes below critical in approximately 3 seconds. So if you had a 10 second runup time then set RSC_CRITICAL to 70%.

Increment

Range

Units

1

0 to 100

percent

H_RSC_IDLE: Throttle Output at Idle

Throttle output (HeliRSC Servo) in percent while armed but motor interlock is disabled (throttle hold on). FOR COMBUSTION ENGINES. Sets the engine ground idle throttle percentage with clutch disengaged. This must be set to zero for electric helicopters under most situations. If the ESC has an autorotation window this can be set to keep the autorotation window open in the ESC. Consult the operating manual for your ESC to set it properly for this purpose

Increment

Range

Units

1

0 to 50

percent

H_RSC_SLEWRATE: Throttle Slew Rate

This controls the maximum rate at which the throttle output (HeliRSC servo) can change, as a percentage per second. A value of 100 means the throttle can change over its full range in one second. A value of zero gives unlimited slew rate.

Increment

Range

10

0 to 500

H_RSC_THRCRV_0: Throttle Curve at 0% Coll

Sets the throttle output (HeliRSC servo) in percent for the throttle curve at the minimum collective pitch position. The 0 percent collective is defined by H_COL_MIN. Example: if the setup has -2 degree to +10 degree collective pitch setup, this setting would correspond to -2 degree of pitch.

Increment

Range

Units

1

0 to 100

percent

H_RSC_THRCRV_25: Throttle Curve at 25% Coll

Sets the throttle output (HeliRSC servo) in percent for the throttle curve at 25% of full collective travel where he 0 percent collective is defined by H_COL_MIN and 100 percent collective is defined by H_COL_MAX. Example: if the setup has -2 degree to +10 degree collective pitch setup, the total range is 12 degrees. 25% of 12 degrees is 3 degrees, so this setting would correspond to +1 degree of pitch.

Increment

Range

Units

1

0 to 100

percent

H_RSC_THRCRV_50: Throttle Curve at 50% Coll

Sets the throttle output (HeliRSC servo) in percent for the throttle curve at 50% of full collective travel where he 0 percent collective is defined by H_COL_MIN and 100 percent collective is defined by H_COL_MAX. Example: if the setup has -2 degree to +10 degree collective pitch setup, the total range is 12 degrees. 50% of 12 degrees is 6 degrees, so this setting would correspond to +4 degree of pitch.

Increment

Range

Units

1

0 to 100

percent

H_RSC_THRCRV_75: Throttle Curve at 75% Coll

Sets the throttle output (HeliRSC servo) in percent for the throttle curve at 75% of full collective travel where he 0 percent collective is defined by H_COL_MIN and 100 percent collective is defined by H_COL_MAX. Example: if the setup has -2 degree to +10 degree collective pitch setup, the total range is 12 degrees. 75% of 12 degrees is 9 degrees, so this setting would correspond to +7 degree of pitch.

Increment

Range

Units

1

0 to 100

percent

H_RSC_THRCRV_100: Throttle Curve at 100% Coll

Sets the throttle output (HeliRSC servo) in percent for the throttle curve at the minimum collective pitch position. The 100 percent collective is defined by H_COL_MAX. Example: if the setup has -2 degree to +10 degree collective pitch setup, this setting would correspond to +10 degree of pitch.

Increment

Range

Units

1

0 to 100

percent

H_RSC_GOV_RANGE: Governor Operational Range

RPM range +/- governor rpm reference setting where governor is operational. If speed sensor fails or rpm falls outside of this range, the governor will disengage and return to throttle curve. Recommended range is 100

Increment

Range

Units

10

50 to 200

Revolutions Per Minute

H_RSC_CLDWN_TIME: Cooldown Time

Will provide a fast idle for engine cooldown by raising the Ground Idle speed setting by 50% for the number of seconds the timer is set for. A setting of zero disables the fast idle. This feature will only apply after the runup complete has been declared. This will not extend the time before ground idle is declared, which triggers engine shutdown for autonomous landings.

Increment

Range

Units

1

0 to 120

seconds

H_RSC_GOV_COMP: Governor Torque Compensator

Adjusts the autothrottle governor torque compensator that determines how fast the governor will adjust the base torque reference to compensate for changes in density altitude. If RPM is low or high by more than 2-5 RPM, increase this setting by 1% at a time until the governor speed matches your RPM setting. Setting the compensator too high can result in surging and throttle "hunting". Do not make large adjustments at one time

Increment

Range

Units

0.1

0 to 70

percent

H_RSC_GOV_DROOP: Governor Droop Compensator

AutoThrottle governor droop response under load, normal settings of 0-50%. Higher value is quicker response to large speed changes due to load but may cause surging. Adjust this to be as aggressive as possible without getting surging or RPM over-run when the governor responds to large load changes on the rotor system

Increment

Range

Units

0.1

0 to 100

percent

H_RSC_GOV_FF: Governor Feedforward

Feedforward governor gain to throttle response during sudden loading/unloading of the rotor system. If RPM drops excessively during full collective climb with the droop response set correctly, increase the governor feedforward.

Increment

Range

Units

0.1

0 to 100

percent

H_RSC_GOV_RPM: Rotor RPM Setting

Main rotor RPM that governor maintains when engaged

Increment

Range

Units

10

800 to 3500

Revolutions Per Minute

H_RSC_GOV_TORQUE: Governor Torque Limiter

Adjusts the engine's percentage of torque rise on autothrottle during ramp-up to governor speed. The torque rise will determine how fast the rotor speed will ramp up when rotor speed reaches 50% of the rotor RPM setting. The sequence of events engaging the governor is as follows: Throttle ramp time will engage the clutch and start the main rotor turning. The collective should be at flat pitch and the throttle curve set to provide at least 50% of normal RPM at flat pitch. The autothrottle torque limiter will automatically activate and start accelerating the main rotor. If the autothrottle consistently fails to accelerate the main rotor during ramp-in due to engine tune or other factors, then increase the torque limiter setting. NOTE: throttle ramp time and throttle curve should be tuned using RSC_MODE Throttle Curve before using RSC_MODE AutoThrottle

Increment

Range

Units

1

10 to 60

percent

H_RSC_AROT_ Parameters

H_RSC_AROT_ENBL: Enable autorotation handling in RSC

Allows you to enable (1) or disable (0) the autorotation functionality within the Rotor Speed Controller.

Values

Value

Meaning

0

Disabled

1

Enabled

H_RSC_AROT_RAMP: Time for in-flight power re-engagement when exiting autorotations

When exiting an autorotation in a bailout manoeuvre, this is the time in seconds for the throttle output (HeliRSC servo) to ramp from idle (H_RSC_AROT_IDLE) to flight throttle setting when motor interlock is re-enabled. When using an ESC with an autorotation bailout function, this parameter should be set to 0.1 (minimum value).

Increment

Range

Units

0.1

0.1 to 10

seconds

H_RSC_AROT_IDLE: Idle throttle percentage during autorotation

Idle throttle used for during autotoration. For external governors, this would be set to a value that is within the autorotation window of the governer/ESC to enable fast spool-up, when bailing out of an autorotation. Set 0 to disable.

Increment

Range

Units

1

0 to 40

percent

H_RSC_AROT_RUNUP: Time allowed for in-flight power re-engagement

When exiting an autorotation in a bailout manoeuvre, this is the expected time in seconds for the main rotor to reach full speed after motor interlock is enabled. Must be at least one second longer than the H_RSC_AROT_RAMP time that is set. This timer should be set for at least the amount of time it takes to get your helicopter to full flight power. Failure to heed this warning could result in early entry into autonomously controlled collective modes (e.g. alt hold, loiter, etc), whereby the collective could be raised before the engine has reached full power, with a subsequently dangerous slowing of head speed.

Increment

Range

Units

0.1

1 to 10

seconds

IM_ Parameters

IM_ACRO_COL_EXP: Acro Mode Collective Expo

Note: This parameter is for advanced users

Used to soften collective pitch inputs near center point in Acro mode.

Values

Value

Meaning

0

Disabled

0.1

Very Low

0.2

Low

0.3

Medium

0.4

High

0.5

Very High

IM_STB_COL_1: Stabilize Collective Low

Helicopter's minimum collective pitch setting at zero collective stick input in Stabilize mode. Set this as a percent of collective range given by H_COL_MAX minus H_COL_MIN.

Increment

Range

Units

1

0 to 100

percent

IM_STB_COL_2: Stabilize Collective Mid-Low

Helicopter's collective pitch setting at mid-low (40%) collective stick input in Stabilize mode. Set this as a percent of collective range given by H_COL_MAX minus H_COL_MIN.

Increment

Range

Units

1

0 to 100

percent

IM_STB_COL_3: Stabilize Collective Mid-High

Helicopter's collective pitch setting at mid-high (60%) collective stick input in Stabilize mode. Set this as a percent of collective range given by H_COL_MAX minus H_COL_MIN.

Increment

Range

Units

1

0 to 100

percent

IM_STB_COL_4: Stabilize Collective High

Helicopter's maximum collective pitch setting at full collective stick input in Stabilize mode. Set this as a percent of collective range given by H_COL_MAX minus H_COL_MIN.

Increment

Range

Units

1

0 to 100

percent

INS Parameters

INS_GYROFFS_X: Gyro offsets of X axis

Note: This parameter is for advanced users

Gyro sensor offsets of X axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS_GYROFFS_Y: Gyro offsets of Y axis

Note: This parameter is for advanced users

Gyro sensor offsets of Y axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS_GYROFFS_Z: Gyro offsets of Z axis

Note: This parameter is for advanced users

Gyro sensor offsets of Z axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS_GYR2OFFS_X: Gyro2 offsets of X axis

Note: This parameter is for advanced users

Gyro2 sensor offsets of X axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS_GYR2OFFS_Y: Gyro2 offsets of Y axis

Note: This parameter is for advanced users

Gyro2 sensor offsets of Y axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS_GYR2OFFS_Z: Gyro2 offsets of Z axis

Note: This parameter is for advanced users

Gyro2 sensor offsets of Z axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS_GYR3OFFS_X: Gyro3 offsets of X axis

Note: This parameter is for advanced users

Gyro3 sensor offsets of X axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS_GYR3OFFS_Y: Gyro3 offsets of Y axis

Note: This parameter is for advanced users

Gyro3 sensor offsets of Y axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS_GYR3OFFS_Z: Gyro3 offsets of Z axis

Note: This parameter is for advanced users

Gyro3 sensor offsets of Z axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS_ACCSCAL_X: Accelerometer scaling of X axis

Note: This parameter is for advanced users

Accelerometer scaling of X axis. Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS_ACCSCAL_Y: Accelerometer scaling of Y axis

Note: This parameter is for advanced users

Accelerometer scaling of Y axis Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS_ACCSCAL_Z: Accelerometer scaling of Z axis

Note: This parameter is for advanced users

Accelerometer scaling of Z axis Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS_ACCOFFS_X: Accelerometer offsets of X axis

Note: This parameter is for advanced users

Accelerometer offsets of X axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS_ACCOFFS_Y: Accelerometer offsets of Y axis

Note: This parameter is for advanced users

Accelerometer offsets of Y axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS_ACCOFFS_Z: Accelerometer offsets of Z axis

Note: This parameter is for advanced users

Accelerometer offsets of Z axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS_ACC2SCAL_X: Accelerometer2 scaling of X axis

Note: This parameter is for advanced users

Accelerometer2 scaling of X axis. Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS_ACC2SCAL_Y: Accelerometer2 scaling of Y axis

Note: This parameter is for advanced users

Accelerometer2 scaling of Y axis Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS_ACC2SCAL_Z: Accelerometer2 scaling of Z axis

Note: This parameter is for advanced users

Accelerometer2 scaling of Z axis Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS_ACC2OFFS_X: Accelerometer2 offsets of X axis

Note: This parameter is for advanced users

Accelerometer2 offsets of X axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS_ACC2OFFS_Y: Accelerometer2 offsets of Y axis

Note: This parameter is for advanced users

Accelerometer2 offsets of Y axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS_ACC2OFFS_Z: Accelerometer2 offsets of Z axis

Note: This parameter is for advanced users

Accelerometer2 offsets of Z axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS_ACC3SCAL_X: Accelerometer3 scaling of X axis

Note: This parameter is for advanced users

Accelerometer3 scaling of X axis. Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS_ACC3SCAL_Y: Accelerometer3 scaling of Y axis

Note: This parameter is for advanced users

Accelerometer3 scaling of Y axis Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS_ACC3SCAL_Z: Accelerometer3 scaling of Z axis

Note: This parameter is for advanced users

Accelerometer3 scaling of Z axis Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS_ACC3OFFS_X: Accelerometer3 offsets of X axis

Note: This parameter is for advanced users

Accelerometer3 offsets of X axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS_ACC3OFFS_Y: Accelerometer3 offsets of Y axis

Note: This parameter is for advanced users

Accelerometer3 offsets of Y axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS_ACC3OFFS_Z: Accelerometer3 offsets of Z axis

Note: This parameter is for advanced users

Accelerometer3 offsets of Z axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS_GYRO_FILTER: Gyro filter cutoff frequency

Note: This parameter is for advanced users

Filter cutoff frequency for gyroscopes. This can be set to a lower value to try to cope with very high vibration levels in aircraft. A value of zero means no filtering (not recommended!)

Range

Units

0 to 256

hertz

INS_ACCEL_FILTER: Accel filter cutoff frequency

Note: This parameter is for advanced users

Filter cutoff frequency for accelerometers. This can be set to a lower value to try to cope with very high vibration levels in aircraft. A value of zero means no filtering (not recommended!)

Range

Units

0 to 256

hertz

INS_USE: Use first IMU for attitude, velocity and position estimates

Note: This parameter is for advanced users

Use first IMU for attitude, velocity and position estimates

Values

Value

Meaning

0

Disabled

1

Enabled

INS_USE2: Use second IMU for attitude, velocity and position estimates

Note: This parameter is for advanced users

Use second IMU for attitude, velocity and position estimates

Values

Value

Meaning

0

Disabled

1

Enabled

INS_USE3: Use third IMU for attitude, velocity and position estimates

Note: This parameter is for advanced users

Use third IMU for attitude, velocity and position estimates

Values

Value

Meaning

0

Disabled

1

Enabled

INS_STILL_THRESH: Stillness threshold for detecting if we are moving

Note: This parameter is for advanced users

Threshold to tolerate vibration to determine if vehicle is motionless. This depends on the frame type and if there is a constant vibration due to motors before launch or after landing. Total motionless is about 0.05. Suggested values: Planes/rover use 0.1, multirotors use 1, tradHeli uses 5

Range

0.05 to 50

INS_GYR_CAL: Gyro Calibration scheme

Note: This parameter is for advanced users

Conrols when automatic gyro calibration is performed

Values

Value

Meaning

0

Never

1

Start-up only

INS_TRIM_OPTION: Accel cal trim option

Note: This parameter is for advanced users

Specifies how the accel cal routine determines the trims

Values

Value

Meaning

0

Don’t adjust the trims

1

Assume first orientation was level

2

Assume ACC_BODYFIX is perfectly aligned to the vehicle

INS_ACC_BODYFIX: Body-fixed accelerometer

Note: This parameter is for advanced users

The body-fixed accelerometer to be used for trim calculation

Values

Value

Meaning

1

IMU 1

2

IMU 2

3

IMU 3

INS_POS1_X: IMU accelerometer X position

Note: This parameter is for advanced users

X position of the first IMU Accelerometer in body frame. Positive X is forward of the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS_POS1_Y: IMU accelerometer Y position

Note: This parameter is for advanced users

Y position of the first IMU accelerometer in body frame. Positive Y is to the right of the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS_POS1_Z: IMU accelerometer Z position

Note: This parameter is for advanced users

Z position of the first IMU accelerometer in body frame. Positive Z is down from the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS_POS2_X: IMU accelerometer X position

Note: This parameter is for advanced users

X position of the second IMU accelerometer in body frame. Positive X is forward of the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS_POS2_Y: IMU accelerometer Y position

Note: This parameter is for advanced users

Y position of the second IMU accelerometer in body frame. Positive Y is to the right of the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS_POS2_Z: IMU accelerometer Z position

Note: This parameter is for advanced users

Z position of the second IMU accelerometer in body frame. Positive Z is down from the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS_POS3_X: IMU accelerometer X position

Note: This parameter is for advanced users

X position of the third IMU accelerometer in body frame. Positive X is forward of the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Range

Units

-10 to 10

meters

INS_POS3_Y: IMU accelerometer Y position

Note: This parameter is for advanced users

Y position of the third IMU accelerometer in body frame. Positive Y is to the right of the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS_POS3_Z: IMU accelerometer Z position

Note: This parameter is for advanced users

Z position of the third IMU accelerometer in body frame. Positive Z is down from the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS_GYR_ID: Gyro ID

Note: This parameter is for advanced users

Gyro sensor ID, taking into account its type, bus and instance

ReadOnly

True

INS_GYR2_ID: Gyro2 ID

Note: This parameter is for advanced users

Gyro2 sensor ID, taking into account its type, bus and instance

ReadOnly

True

INS_GYR3_ID: Gyro3 ID

Note: This parameter is for advanced users

Gyro3 sensor ID, taking into account its type, bus and instance

ReadOnly

True

INS_ACC_ID: Accelerometer ID

Note: This parameter is for advanced users

Accelerometer sensor ID, taking into account its type, bus and instance

ReadOnly

True

INS_ACC2_ID: Accelerometer2 ID

Note: This parameter is for advanced users

Accelerometer2 sensor ID, taking into account its type, bus and instance

ReadOnly

True

INS_ACC3_ID: Accelerometer3 ID

Note: This parameter is for advanced users

Accelerometer3 sensor ID, taking into account its type, bus and instance

ReadOnly

True

INS_FAST_SAMPLE: Fast sampling mask

Note: This parameter is for advanced users

Mask of IMUs to enable fast sampling on, if available

Bitmask

Bit

Meaning

0

FirstIMU

1

SecondIMU

2

ThirdIMU

INS_ENABLE_MASK: IMU enable mask

Note: This parameter is for advanced users

Bitmask of IMUs to enable. It can be used to prevent startup of specific detected IMUs

Bitmask

Bit

Meaning

0

FirstIMU

1

SecondIMU

2

ThirdIMU

3

FourthIMU

4

FifthIMU

5

SixthIMU

6

SeventhIMU

INS_GYRO_RATE: Gyro rate for IMUs with Fast Sampling enabled

Note: This parameter is for advanced users
Note: Reboot required after change

Gyro rate for IMUs with fast sampling enabled. The gyro rate is the sample rate at which the IMU filters operate and needs to be at least double the maximum filter frequency. If the sensor does not support the selected rate the next highest supported rate will be used. For IMUs which do not support fast sampling this setting is ignored and the default gyro rate of 1Khz is used.

Values

Value

Meaning

0

1kHz

1

2kHz

2

4kHz

3

8kHz

INS_ACC1_CALTEMP: Calibration temperature for 1st accelerometer

Note: This parameter is for advanced users

Temperature that the 1st accelerometer was calibrated at

Calibration

Units

1

degrees Celsius

INS_GYR1_CALTEMP: Calibration temperature for 1st gyroscope

Note: This parameter is for advanced users

Temperature that the 1st gyroscope was calibrated at

Calibration

Units

1

degrees Celsius

INS_ACC2_CALTEMP: Calibration temperature for 2nd accelerometer

Note: This parameter is for advanced users

Temperature that the 2nd accelerometer was calibrated at

Calibration

Units

1

degrees Celsius

INS_GYR2_CALTEMP: Calibration temperature for 2nd gyroscope

Note: This parameter is for advanced users

Temperature that the 2nd gyroscope was calibrated at

Calibration

Units

1

degrees Celsius

INS_ACC3_CALTEMP: Calibration temperature for 3rd accelerometer

Note: This parameter is for advanced users

Temperature that the 3rd accelerometer was calibrated at

Calibration

Units

1

degrees Celsius

INS_GYR3_CALTEMP: Calibration temperature for 3rd gyroscope

Note: This parameter is for advanced users

Temperature that the 3rd gyroscope was calibrated at

Calibration

Units

1

degrees Celsius

INS_TCAL_OPTIONS: Options for temperature calibration

Note: This parameter is for advanced users

This enables optional temperature calibration features. Setting of the Persist bits will save the temperature and/or accelerometer calibration parameters in the bootloader sector on the next update of the bootloader.

Bitmask

Bit

Meaning

0

PersistTemps

1

PersistAccels

INS_RAW_LOG_OPT: Raw logging options

Note: This parameter is for advanced users

Raw logging options bitmask

Bitmask

Bit

Meaning

0

Log primary gyro only

1

Log all gyros

2

Post filter

3

Pre and post filter

INS4_ Parameters

INS4_USE: Use first IMU for attitude, velocity and position estimates

Note: This parameter is for advanced users

Use first IMU for attitude, velocity and position estimates

Values

Value

Meaning

0

Disabled

1

Enabled

INS4_ACC_ID: Accelerometer ID

Note: This parameter is for advanced users

Accelerometer sensor ID, taking into account its type, bus and instance

ReadOnly

True

INS4_ACCSCAL_X: Accelerometer scaling of X axis

Note: This parameter is for advanced users

Accelerometer scaling of X axis. Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS4_ACCSCAL_Y: Accelerometer scaling of Y axis

Note: This parameter is for advanced users

Accelerometer scaling of Y axis Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS4_ACCSCAL_Z: Accelerometer scaling of Z axis

Note: This parameter is for advanced users

Accelerometer scaling of Z axis Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS4_ACCOFFS_X: Accelerometer offsets of X axis

Note: This parameter is for advanced users

Accelerometer offsets of X axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS4_ACCOFFS_Y: Accelerometer offsets of Y axis

Note: This parameter is for advanced users

Accelerometer offsets of Y axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS4_ACCOFFS_Z: Accelerometer offsets of Z axis

Note: This parameter is for advanced users

Accelerometer offsets of Z axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS4_POS_X: IMU accelerometer X position

Note: This parameter is for advanced users

X position of the first IMU Accelerometer in body frame. Positive X is forward of the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS4_POS_Y: IMU accelerometer Y position

Note: This parameter is for advanced users

Y position of the first IMU accelerometer in body frame. Positive Y is to the right of the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS4_POS_Z: IMU accelerometer Z position

Note: This parameter is for advanced users

Z position of the first IMU accelerometer in body frame. Positive Z is down from the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS4_ACC_CALTEMP: Calibration temperature for accelerometer

Note: This parameter is for advanced users

Temperature that the accelerometer was calibrated at

Calibration

Units

1

degrees Celsius

INS4_GYR_ID: Gyro ID

Note: This parameter is for advanced users

Gyro sensor ID, taking into account its type, bus and instance

ReadOnly

True

INS4_GYROFFS_X: Gyro offsets of X axis

Note: This parameter is for advanced users

Gyro sensor offsets of X axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS4_GYROFFS_Y: Gyro offsets of Y axis

Note: This parameter is for advanced users

Gyro sensor offsets of Y axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS4_GYROFFS_Z: Gyro offsets of Z axis

Note: This parameter is for advanced users

Gyro sensor offsets of Z axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS4_GYR_CALTEMP: Calibration temperature for gyroscope

Note: This parameter is for advanced users

Temperature that the gyroscope was calibrated at

Calibration

Units

1

degrees Celsius

INS4_TCAL_ Parameters

INS4_TCAL_ENABLE: Enable temperature calibration

Note: This parameter is for advanced users
Note: Reboot required after change

Enable the use of temperature calibration parameters for this IMU. For automatic learning set to 2 and also set the INS_TCALn_TMAX to the target temperature, then reboot

Values

Value

Meaning

0

Disabled

1

Enabled

2

LearnCalibration

INS4_TCAL_TMIN: Temperature calibration min

Note: This parameter is for advanced users

The minimum temperature that the calibration is valid for

Calibration

Range

Units

1

-70 to 80

degrees Celsius

INS4_TCAL_TMAX: Temperature calibration max

Note: This parameter is for advanced users

The maximum temperature that the calibration is valid for. This must be at least 10 degrees above TMIN for calibration

Calibration

Range

Units

1

-70 to 80

degrees Celsius

INS4_TCAL_ACC1_X: Accelerometer 1st order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_ACC1_Y: Accelerometer 1st order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_ACC1_Z: Accelerometer 1st order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_ACC2_X: Accelerometer 2nd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_ACC2_Y: Accelerometer 2nd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_ACC2_Z: Accelerometer 2nd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_ACC3_X: Accelerometer 3rd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_ACC3_Y: Accelerometer 3rd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_ACC3_Z: Accelerometer 3rd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_GYR1_X: Gyroscope 1st order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_GYR1_Y: Gyroscope 1st order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_GYR1_Z: Gyroscope 1st order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_GYR2_X: Gyroscope 2nd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_GYR2_Y: Gyroscope 2nd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_GYR2_Z: Gyroscope 2nd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_GYR3_X: Gyroscope 3rd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_GYR3_Y: Gyroscope 3rd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS4_TCAL_GYR3_Z: Gyroscope 3rd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS5_ Parameters

INS5_USE: Use first IMU for attitude, velocity and position estimates

Note: This parameter is for advanced users

Use first IMU for attitude, velocity and position estimates

Values

Value

Meaning

0

Disabled

1

Enabled

INS5_ACC_ID: Accelerometer ID

Note: This parameter is for advanced users

Accelerometer sensor ID, taking into account its type, bus and instance

ReadOnly

True

INS5_ACCSCAL_X: Accelerometer scaling of X axis

Note: This parameter is for advanced users

Accelerometer scaling of X axis. Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS5_ACCSCAL_Y: Accelerometer scaling of Y axis

Note: This parameter is for advanced users

Accelerometer scaling of Y axis Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS5_ACCSCAL_Z: Accelerometer scaling of Z axis

Note: This parameter is for advanced users

Accelerometer scaling of Z axis Calculated during acceleration calibration routine

Calibration

Range

1

0.8 to 1.2

INS5_ACCOFFS_X: Accelerometer offsets of X axis

Note: This parameter is for advanced users

Accelerometer offsets of X axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS5_ACCOFFS_Y: Accelerometer offsets of Y axis

Note: This parameter is for advanced users

Accelerometer offsets of Y axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS5_ACCOFFS_Z: Accelerometer offsets of Z axis

Note: This parameter is for advanced users

Accelerometer offsets of Z axis. This is setup using the acceleration calibration or level operations

Calibration

Range

Units

1

-3.5 to 3.5

meters per square second

INS5_POS_X: IMU accelerometer X position

Note: This parameter is for advanced users

X position of the first IMU Accelerometer in body frame. Positive X is forward of the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS5_POS_Y: IMU accelerometer Y position

Note: This parameter is for advanced users

Y position of the first IMU accelerometer in body frame. Positive Y is to the right of the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS5_POS_Z: IMU accelerometer Z position

Note: This parameter is for advanced users

Z position of the first IMU accelerometer in body frame. Positive Z is down from the origin. Attention: The IMU should be located as close to the vehicle c.g. as practical so that the value of this parameter is minimised. Failure to do so can result in noisy navigation velocity measurements due to vibration and IMU gyro noise. If the IMU cannot be moved and velocity noise is a problem, a location closer to the IMU can be used as the body frame origin.

Increment

Range

Units

0.01

-5 to 5

meters

INS5_ACC_CALTEMP: Calibration temperature for accelerometer

Note: This parameter is for advanced users

Temperature that the accelerometer was calibrated at

Calibration

Units

1

degrees Celsius

INS5_GYR_ID: Gyro ID

Note: This parameter is for advanced users

Gyro sensor ID, taking into account its type, bus and instance

ReadOnly

True

INS5_GYROFFS_X: Gyro offsets of X axis

Note: This parameter is for advanced users

Gyro sensor offsets of X axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS5_GYROFFS_Y: Gyro offsets of Y axis

Note: This parameter is for advanced users

Gyro sensor offsets of Y axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS5_GYROFFS_Z: Gyro offsets of Z axis

Note: This parameter is for advanced users

Gyro sensor offsets of Z axis. This is setup on each boot during gyro calibrations

Calibration

Units

1

radians per second

INS5_GYR_CALTEMP: Calibration temperature for gyroscope

Note: This parameter is for advanced users

Temperature that the gyroscope was calibrated at

Calibration

Units

1

degrees Celsius

INS5_TCAL_ Parameters

INS5_TCAL_ENABLE: Enable temperature calibration

Note: This parameter is for advanced users
Note: Reboot required after change

Enable the use of temperature calibration parameters for this IMU. For automatic learning set to 2 and also set the INS_TCALn_TMAX to the target temperature, then reboot

Values

Value

Meaning

0

Disabled

1

Enabled

2

LearnCalibration

INS5_TCAL_TMIN: Temperature calibration min

Note: This parameter is for advanced users

The minimum temperature that the calibration is valid for

Calibration

Range

Units

1

-70 to 80

degrees Celsius

INS5_TCAL_TMAX: Temperature calibration max

Note: This parameter is for advanced users

The maximum temperature that the calibration is valid for. This must be at least 10 degrees above TMIN for calibration

Calibration

Range

Units

1

-70 to 80

degrees Celsius

INS5_TCAL_ACC1_X: Accelerometer 1st order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_ACC1_Y: Accelerometer 1st order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_ACC1_Z: Accelerometer 1st order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_ACC2_X: Accelerometer 2nd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_ACC2_Y: Accelerometer 2nd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_ACC2_Z: Accelerometer 2nd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_ACC3_X: Accelerometer 3rd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_ACC3_Y: Accelerometer 3rd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_ACC3_Z: Accelerometer 3rd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_GYR1_X: Gyroscope 1st order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_GYR1_Y: Gyroscope 1st order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_GYR1_Z: Gyroscope 1st order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_GYR2_X: Gyroscope 2nd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_GYR2_Y: Gyroscope 2nd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_GYR2_Z: Gyroscope 2nd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_GYR3_X: Gyroscope 3rd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_GYR3_Y: Gyroscope 3rd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS5_TCAL_GYR3_Z: Gyroscope 3rd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_HNTC2_ Parameters

INS_HNTC2_ENABLE: Harmonic Notch Filter enable

Note: This parameter is for advanced users

Harmonic Notch Filter enable

Values

Value

Meaning

0

Disabled

1

Enabled

INS_HNTC2_FREQ: Harmonic Notch Filter base frequency

Note: This parameter is for advanced users

Harmonic Notch Filter base center frequency in Hz. This is the center frequency for static notches, the center frequency for Throttle based notches at the reference thrust value, and the minimum limit of center frequency variation for all other notch types. This should always be set lower than half the backend gyro rate (which is typically 1Khz).

Range

Units

10 to 495

hertz

INS_HNTC2_BW: Harmonic Notch Filter bandwidth

Note: This parameter is for advanced users

Harmonic Notch Filter bandwidth in Hz. This is typically set to half the base frequency. The ratio of base frequency to bandwidth determines the notch quality factor and is fixed across harmonics.

Range

Units

5 to 250

hertz

INS_HNTC2_ATT: Harmonic Notch Filter attenuation

Note: This parameter is for advanced users

Harmonic Notch Filter attenuation in dB. Values greater than 40dB will typically produce a hard notch rather than a modest attenuation of motor noise.

Range

Units

5 to 50

decibel

INS_HNTC2_HMNCS: Harmonic Notch Filter harmonics

Note: This parameter is for advanced users
Note: Reboot required after change

Bitmask of harmonic frequencies to apply Harmonic Notch Filter to. This option takes effect on the next reboot. A value of 0 disables this filter. The first harmonic refers to the base frequency.

Bitmask

Bit

Meaning

0

1st harmonic

1

2nd harmonic

2

3rd harmonic

3

4th harmonic

4

5th harmonic

5

6th harmonic

6

7th harmonic

7

8th harmonic

8

9th harmonic

9

10th harmonic

10

11th harmonic

11

12th harmonic

12

13th harmonic

13

14th harmonic

14

15th harmonic

15

16th harmonic

INS_HNTC2_REF: Harmonic Notch Filter reference value

Note: This parameter is for advanced users
Note: Reboot required after change

A reference value of zero disables dynamic updates on the Harmonic Notch Filter and a positive value enables dynamic updates on the Harmonic Notch Filter. For throttle-based scaling, this parameter is the reference value associated with the specified frequency to facilitate frequency scaling of the Harmonic Notch Filter. For RPM and ESC telemetry based tracking, this parameter is set to 1 to enable the Harmonic Notch Filter using the RPM sensor or ESC telemetry set to measure rotor speed. The sensor data is converted to Hz automatically for use in the Harmonic Notch Filter. This reference value may also be used to scale the sensor data, if required. For example, rpm sensor data is required to measure heli motor RPM. Therefore the reference value can be used to scale the RPM sensor to the rotor RPM.

Range

0.0 to 1.0

INS_HNTC2_MODE: Harmonic Notch Filter dynamic frequency tracking mode

Note: This parameter is for advanced users

Harmonic Notch Filter dynamic frequency tracking mode. Dynamic updates can be throttle, RPM sensor, ESC telemetry or dynamic FFT based. Throttle-based harmonic notch cannot be used on fixed wing only planes. It can for Copters, QuaadPlane(while in VTOL modes), and Rovers.

Range

Values

0 to 5

Value

Meaning

0

Fixed

1

Throttle

2

RPM Sensor

3

ESC Telemetry

4

Dynamic FFT

5

Second RPM Sensor

INS_HNTC2_OPTS: Harmonic Notch Filter options

Note: This parameter is for advanced users
Note: Reboot required after change

Harmonic Notch Filter options. Triple and double-notches can provide deeper attenuation across a wider bandwidth with reduced latency than single notches and are suitable for larger aircraft. Multi-Source attaches a harmonic notch to each detected noise frequency instead of simply being multiples of the base frequency, in the case of FFT it will attach notches to each of three detected noise peaks, in the case of ESC it will attach notches to each of four motor RPM values. Loop rate update changes the notch center frequency at the scheduler loop rate rather than at the default of 200Hz. If both double and triple notches are specified only double notches will take effect.

Bitmask

Bit

Meaning

0

Double notch

1

Multi-Source

2

Update at loop rate

3

EnableOnAllIMUs

4

Triple notch

5

Use min freq on RPM source failure

INS_HNTC2_FM_RAT: Throttle notch min freqency ratio

Note: This parameter is for advanced users

The minimum ratio below the configured frequency to take throttle based notch filters when flying at a throttle level below the reference throttle. Note that lower frequency notch filters will have more phase lag. If you want throttle based notch filtering to be effective at a throttle up to 30% below the configured notch frequency then set this parameter to 0.7. The default of 1.0 means the notch will not go below the frequency in the FREQ parameter.

Range

0.1 to 1.0

INS_HNTCH_ Parameters

INS_HNTCH_ENABLE: Harmonic Notch Filter enable

Note: This parameter is for advanced users

Harmonic Notch Filter enable

Values

Value

Meaning

0

Disabled

1

Enabled

INS_HNTCH_FREQ: Harmonic Notch Filter base frequency

Note: This parameter is for advanced users

Harmonic Notch Filter base center frequency in Hz. This is the center frequency for static notches, the center frequency for Throttle based notches at the reference thrust value, and the minimum limit of center frequency variation for all other notch types. This should always be set lower than half the backend gyro rate (which is typically 1Khz).

Range

Units

10 to 495

hertz

INS_HNTCH_BW: Harmonic Notch Filter bandwidth

Note: This parameter is for advanced users

Harmonic Notch Filter bandwidth in Hz. This is typically set to half the base frequency. The ratio of base frequency to bandwidth determines the notch quality factor and is fixed across harmonics.

Range

Units

5 to 250

hertz

INS_HNTCH_ATT: Harmonic Notch Filter attenuation

Note: This parameter is for advanced users

Harmonic Notch Filter attenuation in dB. Values greater than 40dB will typically produce a hard notch rather than a modest attenuation of motor noise.

Range

Units

5 to 50

decibel

INS_HNTCH_HMNCS: Harmonic Notch Filter harmonics

Note: This parameter is for advanced users
Note: Reboot required after change

Bitmask of harmonic frequencies to apply Harmonic Notch Filter to. This option takes effect on the next reboot. A value of 0 disables this filter. The first harmonic refers to the base frequency.

Bitmask

Bit

Meaning

0

1st harmonic

1

2nd harmonic

2

3rd harmonic

3

4th harmonic

4

5th harmonic

5

6th harmonic

6

7th harmonic

7

8th harmonic

8

9th harmonic

9

10th harmonic

10

11th harmonic

11

12th harmonic

12

13th harmonic

13

14th harmonic

14

15th harmonic

15

16th harmonic

INS_HNTCH_REF: Harmonic Notch Filter reference value

Note: This parameter is for advanced users
Note: Reboot required after change

A reference value of zero disables dynamic updates on the Harmonic Notch Filter and a positive value enables dynamic updates on the Harmonic Notch Filter. For throttle-based scaling, this parameter is the reference value associated with the specified frequency to facilitate frequency scaling of the Harmonic Notch Filter. For RPM and ESC telemetry based tracking, this parameter is set to 1 to enable the Harmonic Notch Filter using the RPM sensor or ESC telemetry set to measure rotor speed. The sensor data is converted to Hz automatically for use in the Harmonic Notch Filter. This reference value may also be used to scale the sensor data, if required. For example, rpm sensor data is required to measure heli motor RPM. Therefore the reference value can be used to scale the RPM sensor to the rotor RPM.

Range

0.0 to 1.0

INS_HNTCH_MODE: Harmonic Notch Filter dynamic frequency tracking mode

Note: This parameter is for advanced users

Harmonic Notch Filter dynamic frequency tracking mode. Dynamic updates can be throttle, RPM sensor, ESC telemetry or dynamic FFT based. Throttle-based harmonic notch cannot be used on fixed wing only planes. It can for Copters, QuaadPlane(while in VTOL modes), and Rovers.

Range

Values

0 to 5

Value

Meaning

0

Fixed

1

Throttle

2

RPM Sensor

3

ESC Telemetry

4

Dynamic FFT

5

Second RPM Sensor

INS_HNTCH_OPTS: Harmonic Notch Filter options

Note: This parameter is for advanced users
Note: Reboot required after change

Harmonic Notch Filter options. Triple and double-notches can provide deeper attenuation across a wider bandwidth with reduced latency than single notches and are suitable for larger aircraft. Multi-Source attaches a harmonic notch to each detected noise frequency instead of simply being multiples of the base frequency, in the case of FFT it will attach notches to each of three detected noise peaks, in the case of ESC it will attach notches to each of four motor RPM values. Loop rate update changes the notch center frequency at the scheduler loop rate rather than at the default of 200Hz. If both double and triple notches are specified only double notches will take effect.

Bitmask

Bit

Meaning

0

Double notch

1

Multi-Source

2

Update at loop rate

3

EnableOnAllIMUs

4

Triple notch

5

Use min freq on RPM source failure

INS_HNTCH_FM_RAT: Throttle notch min freqency ratio

Note: This parameter is for advanced users

The minimum ratio below the configured frequency to take throttle based notch filters when flying at a throttle level below the reference throttle. Note that lower frequency notch filters will have more phase lag. If you want throttle based notch filtering to be effective at a throttle up to 30% below the configured notch frequency then set this parameter to 0.7. The default of 1.0 means the notch will not go below the frequency in the FREQ parameter.

Range

0.1 to 1.0

INS_LOG_ Parameters

INS_LOG_BAT_CNT: sample count per batch

Note: This parameter is for advanced users
Note: Reboot required after change

Number of samples to take when logging streams of IMU sensor readings. Will be rounded down to a multiple of 32. This option takes effect on the next reboot.

Increment

32

INS_LOG_BAT_MASK: Sensor Bitmask

Note: This parameter is for advanced users
Note: Reboot required after change

Bitmap of which IMUs to log batch data for. This option takes effect on the next reboot.

Bitmask

Bit

Meaning

0

IMU1

1

IMU2

2

IMU3

INS_LOG_BAT_OPT: Batch Logging Options Mask

Note: This parameter is for advanced users

Options for the BatchSampler.

Bitmask

Bit

Meaning

0

Sensor-Rate Logging (sample at full sensor rate seen by AP)

1

Sample post-filtering

2

Sample pre- and post-filter

INS_LOG_BAT_LGIN: logging interval

Interval between pushing samples to the AP_Logger log

Increment

Units

10

milliseconds

INS_LOG_BAT_LGCT: logging count

Number of samples to push to count every INS_LOG_BAT_LGIN

Increment

1

INS_TCAL1_ Parameters

INS_TCAL1_ENABLE: Enable temperature calibration

Note: This parameter is for advanced users
Note: Reboot required after change

Enable the use of temperature calibration parameters for this IMU. For automatic learning set to 2 and also set the INS_TCALn_TMAX to the target temperature, then reboot

Values

Value

Meaning

0

Disabled

1

Enabled

2

LearnCalibration

INS_TCAL1_TMIN: Temperature calibration min

Note: This parameter is for advanced users

The minimum temperature that the calibration is valid for

Calibration

Range

Units

1

-70 to 80

degrees Celsius

INS_TCAL1_TMAX: Temperature calibration max

Note: This parameter is for advanced users

The maximum temperature that the calibration is valid for. This must be at least 10 degrees above TMIN for calibration

Calibration

Range

Units

1

-70 to 80

degrees Celsius

INS_TCAL1_ACC1_X: Accelerometer 1st order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_ACC1_Y: Accelerometer 1st order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_ACC1_Z: Accelerometer 1st order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_ACC2_X: Accelerometer 2nd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_ACC2_Y: Accelerometer 2nd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_ACC2_Z: Accelerometer 2nd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_ACC3_X: Accelerometer 3rd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_ACC3_Y: Accelerometer 3rd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_ACC3_Z: Accelerometer 3rd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_GYR1_X: Gyroscope 1st order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_GYR1_Y: Gyroscope 1st order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_GYR1_Z: Gyroscope 1st order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_GYR2_X: Gyroscope 2nd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_GYR2_Y: Gyroscope 2nd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_GYR2_Z: Gyroscope 2nd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_GYR3_X: Gyroscope 3rd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_GYR3_Y: Gyroscope 3rd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL1_GYR3_Z: Gyroscope 3rd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_ Parameters

INS_TCAL2_ENABLE: Enable temperature calibration

Note: This parameter is for advanced users
Note: Reboot required after change

Enable the use of temperature calibration parameters for this IMU. For automatic learning set to 2 and also set the INS_TCALn_TMAX to the target temperature, then reboot

Values

Value

Meaning

0

Disabled

1

Enabled

2

LearnCalibration

INS_TCAL2_TMIN: Temperature calibration min

Note: This parameter is for advanced users

The minimum temperature that the calibration is valid for

Calibration

Range

Units

1

-70 to 80

degrees Celsius

INS_TCAL2_TMAX: Temperature calibration max

Note: This parameter is for advanced users

The maximum temperature that the calibration is valid for. This must be at least 10 degrees above TMIN for calibration

Calibration

Range

Units

1

-70 to 80

degrees Celsius

INS_TCAL2_ACC1_X: Accelerometer 1st order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_ACC1_Y: Accelerometer 1st order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_ACC1_Z: Accelerometer 1st order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_ACC2_X: Accelerometer 2nd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_ACC2_Y: Accelerometer 2nd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_ACC2_Z: Accelerometer 2nd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_ACC3_X: Accelerometer 3rd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_ACC3_Y: Accelerometer 3rd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_ACC3_Z: Accelerometer 3rd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_GYR1_X: Gyroscope 1st order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_GYR1_Y: Gyroscope 1st order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_GYR1_Z: Gyroscope 1st order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_GYR2_X: Gyroscope 2nd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_GYR2_Y: Gyroscope 2nd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_GYR2_Z: Gyroscope 2nd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_GYR3_X: Gyroscope 3rd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_GYR3_Y: Gyroscope 3rd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL2_GYR3_Z: Gyroscope 3rd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_ Parameters

INS_TCAL3_ENABLE: Enable temperature calibration

Note: This parameter is for advanced users
Note: Reboot required after change

Enable the use of temperature calibration parameters for this IMU. For automatic learning set to 2 and also set the INS_TCALn_TMAX to the target temperature, then reboot

Values

Value

Meaning

0

Disabled

1

Enabled

2

LearnCalibration

INS_TCAL3_TMIN: Temperature calibration min

Note: This parameter is for advanced users

The minimum temperature that the calibration is valid for

Calibration

Range

Units

1

-70 to 80

degrees Celsius

INS_TCAL3_TMAX: Temperature calibration max

Note: This parameter is for advanced users

The maximum temperature that the calibration is valid for. This must be at least 10 degrees above TMIN for calibration

Calibration

Range

Units

1

-70 to 80

degrees Celsius

INS_TCAL3_ACC1_X: Accelerometer 1st order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_ACC1_Y: Accelerometer 1st order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_ACC1_Z: Accelerometer 1st order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_ACC2_X: Accelerometer 2nd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_ACC2_Y: Accelerometer 2nd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_ACC2_Z: Accelerometer 2nd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_ACC3_X: Accelerometer 3rd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_ACC3_Y: Accelerometer 3rd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_ACC3_Z: Accelerometer 3rd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_GYR1_X: Gyroscope 1st order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_GYR1_Y: Gyroscope 1st order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_GYR1_Z: Gyroscope 1st order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 1st order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_GYR2_X: Gyroscope 2nd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_GYR2_Y: Gyroscope 2nd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_GYR2_Z: Gyroscope 2nd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 2nd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_GYR3_X: Gyroscope 3rd order temperature coefficient X axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_GYR3_Y: Gyroscope 3rd order temperature coefficient Y axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

INS_TCAL3_GYR3_Z: Gyroscope 3rd order temperature coefficient Z axis

Note: This parameter is for advanced users

This is the 3rd order temperature coefficient from a temperature calibration

Calibration

1

KDE_ Parameters

KDE_NPOLE: Number of motor poles

Sets the number of motor poles to calculate the correct RPM value

LGR_ Parameters

LGR_ENABLE: Enable landing gear

Enable landing gear control

Values

Value

Meaning

0

Disabled

1

Enabled

LGR_STARTUP: Landing Gear Startup position

Landing Gear Startup behaviour control

Values

Value

Meaning

0

WaitForPilotInput

1

Retract

2

Deploy

LGR_DEPLOY_PIN: Chassis deployment feedback pin

Note: Reboot required after change

Pin number to use for detection of gear deployment. If set to -1 feedback is disabled. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

LGR_DEPLOY_POL: Chassis deployment feedback pin polarity

Polarity for feedback pin. If this is 1 then the pin should be high when gear are deployed. If set to 0 then then deployed gear level is low.

Values

Value

Meaning

0

Low

1

High

LGR_WOW_PIN: Weight on wheels feedback pin

Note: Reboot required after change

Pin number to use for feedback of weight on wheels condition. If set to -1 feedback is disabled. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

LGR_WOW_POL: Weight on wheels feedback pin polarity

Polarity for feedback pin. If this is 1 then the pin should be high when there is weight on wheels. If set to 0 then then weight on wheels level is low.

Values

Value

Meaning

0

Low

1

High

LGR_DEPLOY_ALT: Landing gear deployment altitude

Altitude where the landing gear will be deployed. This should be lower than the RETRACT_ALT. If zero then altitude is not used for deploying landing gear. Only applies when vehicle is armed.

Increment

Range

Units

1

0 to 1000

meters

LGR_RETRACT_ALT: Landing gear retract altitude

Altitude where the landing gear will be retracted. This should be higher than the DEPLOY_ALT. If zero then altitude is not used for retracting landing gear. Only applies when vehicle is armed.

Increment

Range

Units

1

0 to 1000

meters

LGR_OPTIONS: Landing gear auto retract/deploy options

Options to retract or deploy landing gear in Auto or Guided mode

Bitmask

Bit

Meaning

0

Retract after Takeoff

1

Deploy during Land

LOG Parameters

LOG_BACKEND_TYPE: AP_Logger Backend Storage type

Bitmap of what Logger backend types to enable. Block-based logging is available on SITL and boards with dataflash chips. Multiple backends can be selected.

Bitmask

Bit

Meaning

0

File

1

MAVLink

2

Block

LOG_FILE_BUFSIZE: Maximum AP_Logger File and Block Backend buffer size (in kilobytes)

The File and Block backends use a buffer to store data before writing to the block device. Raising this value may reduce "gaps" in your SD card logging. This buffer size may be reduced depending on available memory. PixHawk requires at least 4 kilobytes. Maximum value available here is 64 kilobytes.

LOG_DISARMED: Enable logging while disarmed

If LOG_DISARMED is set to 1 then logging will be enabled at all times including when disarmed. Logging before arming can make for very large logfiles but can help a lot when tracking down startup issues and is necessary if logging of EKF replay data is selected via the LOG_REPLAY parameter. If LOG_DISARMED is set to 2, then logging will be enabled when disarmed, but not if a USB connection is detected. This can be used to prevent unwanted data logs being generated when the vehicle is connected via USB for log downloading or parameter changes. If LOG_DISARMED is set to 3 then logging will happen while disarmed, but if the vehicle never arms then the logs using the filesystem backend will be discarded on the next boot.

Values

Value

Meaning

0

Disabled

1

Enabled

2

Disabled on USB connection

3

Discard log on reboot if never armed

LOG_REPLAY: Enable logging of information needed for Replay

If LOG_REPLAY is set to 1 then the EKF2 and EKF3 state estimators will log detailed information needed for diagnosing problems with the Kalman filter. LOG_DISARMED must be set to 1 or 2 or else the log will not contain the pre-flight data required for replay testing of the EKF's. It is suggested that you also raise LOG_FILE_BUFSIZE to give more buffer space for logging and use a high quality microSD card to ensure no sensor data is lost.

Values

Value

Meaning

0

Disabled

1

Enabled

LOG_FILE_DSRMROT: Stop logging to current file on disarm

When set, the current log file is closed when the vehicle is disarmed. If LOG_DISARMED is set then a fresh log will be opened. Applies to the File and Block logging backends.

Values

Value

Meaning

0

Disabled

1

Enabled

LOG_FILE_TIMEOUT: Timeout before giving up on file writes

This controls the amount of time before failing writes to a log file cause the file to be closed and logging stopped.

Units

seconds

LOG_FILE_MB_FREE: Old logs on the SD card will be deleted to maintain this amount of free space

Set this such that the free space is larger than your largest typical flight log

Range

Units

10 to 1000

megabyte

LOG_FILE_RATEMAX: Maximum logging rate for file backend

This sets the maximum rate that streaming log messages will be logged to the file backend. A value of zero means that rate limiting is disabled.

Increment

Range

Units

0.1

0 to 1000

hertz

LOG_BLK_RATEMAX: Maximum logging rate for block backend

This sets the maximum rate that streaming log messages will be logged to the block backend. A value of zero means that rate limiting is disabled.

Increment

Range

Units

0.1

0 to 1000

hertz

LOG_DARM_RATEMAX: Maximum logging rate when disarmed

This sets the maximum rate that streaming log messages will be logged to any backend when disarmed. A value of zero means that the normal backend rate limit is applied.

Increment

Range

Units

0.1

0 to 1000

hertz

LOG_MAX_FILES: Maximum number of log files

Note: This parameter is for advanced users
Note: Reboot required after change

This sets the maximum number of log file that will be written on dataflash or sd card before starting to rotate log number. Limit is capped at 500 logs.

Increment

Range

1

2 to 500

LOIT_ Parameters

LOIT_ANG_MAX: Loiter pilot angle max

Note: This parameter is for advanced users

Loiter maximum pilot requested lean angle. Set to zero for 2/3 of PSC_ANGLE_MAX/ANGLE_MAX. The maximum vehicle lean angle is still limited by PSC_ANGLE_MAX/ANGLE_MAX

Increment

Range

Units

1

0 to 45

degrees

LOIT_SPEED: Loiter Horizontal Maximum Speed

Defines the maximum speed in cm/s which the aircraft will travel horizontally while in loiter mode

Increment

Range

Units

50

20 to 3500

centimeters per second

LOIT_ACC_MAX: Loiter maximum correction acceleration

Note: This parameter is for advanced users

Loiter maximum correction acceleration in cm/s/s. Higher values cause the copter to correct position errors more aggressively.

Increment

Range

Units

1

100 to 981

centimeters per square second

LOIT_BRK_ACCEL: Loiter braking acceleration

Note: This parameter is for advanced users

Loiter braking acceleration in cm/s/s. Higher values stop the copter more quickly when the stick is centered.

Increment

Range

Units

1

25 to 250

centimeters per square second

LOIT_BRK_JERK: Loiter braking jerk

Note: This parameter is for advanced users

Loiter braking jerk in cm/s/s/s. Higher values will remove braking faster if the pilot moves the sticks during a braking maneuver.

Increment

Range

Units

1

500 to 5000

centimeters per cubic second

LOIT_BRK_DELAY: Loiter brake start delay (in seconds)

Note: This parameter is for advanced users

Loiter brake start delay (in seconds)

Increment

Range

Units

0.1

0 to 2

seconds

MIS_ Parameters

MIS_TOTAL: Total mission commands

Note: This parameter is for advanced users

The number of mission mission items that has been loaded by the ground station. Do not change this manually.

Increment

Range

ReadOnly

1

0 to 32766

True

MIS_RESTART: Mission Restart when entering Auto mode

Note: This parameter is for advanced users

Controls mission starting point when entering Auto mode (either restart from beginning of mission or resume from last command run)

Values

Value

Meaning

0

Resume Mission

1

Restart Mission

MIS_OPTIONS: Mission options bitmask

Note: This parameter is for advanced users

Bitmask of what options to use in missions.

Bitmask

Bit

Meaning

0

Clear Mission on reboot

2

ContinueAfterLand

MNT1 Parameters

MNT1_TYPE: Mount Type

Note: Reboot required after change

Mount Type

Values

Value

Meaning

0

None

1

Servo

2

3DR Solo

3

Alexmos Serial

4

SToRM32 MAVLink

5

SToRM32 Serial

6

Gremsy

7

BrushlessPWM

8

Siyi

9

Scripting

10

Xacti

11

Viewpro

12

Topotek

MNT1_DEFLT_MODE: Mount default operating mode

Mount default operating mode on startup and after control is returned from autopilot

Values

Value

Meaning

0

Retracted

1

Neutral

2

MavLink Targeting

3

RC Targeting

4

GPS Point

5

SysID Target

6

Home Location

MNT1_RC_RATE: Mount RC Rate

Pilot rate control's maximum rate. Set to zero to use angle control

Increment

Range

Units

1

0 to 90

degrees per second

MNT1_ROLL_MIN: Mount Roll angle minimum

Mount Roll angle minimum

Increment

Range

Units

1

-180 to 180

degrees

MNT1_ROLL_MAX: Mount Roll angle maximum

Mount Roll angle maximum

Increment

Range

Units

1

-180 to 180

degrees

MNT1_PITCH_MIN: Mount Pitch angle minimum

Mount Pitch angle minimum

Increment

Range

Units

1

-90 to 90

degrees

MNT1_PITCH_MAX: Mount Pitch angle maximum

Mount Pitch angle maximum

Increment

Range

Units

1

-90 to 90

degrees

MNT1_YAW_MIN: Mount Yaw angle minimum

Mount Yaw angle minimum

Increment

Range

Units

1

-180 to 180

degrees

MNT1_YAW_MAX: Mount Yaw angle maximum

Mount Yaw angle maximum

Increment

Range

Units

1

-180 to 180

degrees

MNT1_RETRACT_X: Mount roll angle when in retracted position

Mount roll angle when in retracted position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT1_RETRACT_Y: Mount pitch angle when in retracted position

Mount pitch angle when in retracted position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT1_RETRACT_Z: Mount yaw angle when in retracted position

Mount yaw angle when in retracted position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT1_NEUTRAL_X: Mount roll angle when in neutral position

Mount roll angle when in neutral position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT1_NEUTRAL_Y: Mount pitch angle when in neutral position

Mount pitch angle when in neutral position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT1_NEUTRAL_Z: Mount yaw angle when in neutral position

Mount yaw angle when in neutral position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT1_LEAD_RLL: Mount Roll stabilization lead time

Servo mount roll angle output leads the vehicle angle by this amount of time based on current roll rate. Increase until the servo is responsive but does not overshoot

Increment

Range

Units

.005

0.0 to 0.2

seconds

MNT1_LEAD_PTCH: Mount Pitch stabilization lead time

Servo mount pitch angle output leads the vehicle angle by this amount of time based on current pitch rate. Increase until the servo is responsive but does not overshoot

Increment

Range

Units

.005

0.0 to 0.2

seconds

MNT1_SYSID_DFLT: Mount Target sysID

Note: Reboot required after change

Default Target sysID for the mount to point to

MNT1_DEVID: Mount Device ID

Note: This parameter is for advanced users

Mount device ID, taking into account its type, bus and instance

MNT1_OPTIONS: Mount options

Mount options bitmask

Bitmask

Bit

Meaning

0

RC lock state from previous mode

1

Return to neutral angles on RC failsafe

MNT2 Parameters

MNT2_TYPE: Mount Type

Note: Reboot required after change

Mount Type

Values

Value

Meaning

0

None

1

Servo

2

3DR Solo

3

Alexmos Serial

4

SToRM32 MAVLink

5

SToRM32 Serial

6

Gremsy

7

BrushlessPWM

8

Siyi

9

Scripting

10

Xacti

11

Viewpro

12

Topotek

MNT2_DEFLT_MODE: Mount default operating mode

Mount default operating mode on startup and after control is returned from autopilot

Values

Value

Meaning

0

Retracted

1

Neutral

2

MavLink Targeting

3

RC Targeting

4

GPS Point

5

SysID Target

6

Home Location

MNT2_RC_RATE: Mount RC Rate

Pilot rate control's maximum rate. Set to zero to use angle control

Increment

Range

Units

1

0 to 90

degrees per second

MNT2_ROLL_MIN: Mount Roll angle minimum

Mount Roll angle minimum

Increment

Range

Units

1

-180 to 180

degrees

MNT2_ROLL_MAX: Mount Roll angle maximum

Mount Roll angle maximum

Increment

Range

Units

1

-180 to 180

degrees

MNT2_PITCH_MIN: Mount Pitch angle minimum

Mount Pitch angle minimum

Increment

Range

Units

1

-90 to 90

degrees

MNT2_PITCH_MAX: Mount Pitch angle maximum

Mount Pitch angle maximum

Increment

Range

Units

1

-90 to 90

degrees

MNT2_YAW_MIN: Mount Yaw angle minimum

Mount Yaw angle minimum

Increment

Range

Units

1

-180 to 180

degrees

MNT2_YAW_MAX: Mount Yaw angle maximum

Mount Yaw angle maximum

Increment

Range

Units

1

-180 to 180

degrees

MNT2_RETRACT_X: Mount roll angle when in retracted position

Mount roll angle when in retracted position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT2_RETRACT_Y: Mount pitch angle when in retracted position

Mount pitch angle when in retracted position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT2_RETRACT_Z: Mount yaw angle when in retracted position

Mount yaw angle when in retracted position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT2_NEUTRAL_X: Mount roll angle when in neutral position

Mount roll angle when in neutral position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT2_NEUTRAL_Y: Mount pitch angle when in neutral position

Mount pitch angle when in neutral position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT2_NEUTRAL_Z: Mount yaw angle when in neutral position

Mount yaw angle when in neutral position

Increment

Range

Units

1

-180.0 to 180.0

degrees

MNT2_LEAD_RLL: Mount Roll stabilization lead time

Servo mount roll angle output leads the vehicle angle by this amount of time based on current roll rate. Increase until the servo is responsive but does not overshoot

Increment

Range

Units

.005

0.0 to 0.2

seconds

MNT2_LEAD_PTCH: Mount Pitch stabilization lead time

Servo mount pitch angle output leads the vehicle angle by this amount of time based on current pitch rate. Increase until the servo is responsive but does not overshoot

Increment

Range

Units

.005

0.0 to 0.2

seconds

MNT2_SYSID_DFLT: Mount Target sysID

Note: Reboot required after change

Default Target sysID for the mount to point to

MNT2_DEVID: Mount Device ID

Note: This parameter is for advanced users

Mount device ID, taking into account its type, bus and instance

MNT2_OPTIONS: Mount options

Mount options bitmask

Bitmask

Bit

Meaning

0

RC lock state from previous mode

1

Return to neutral angles on RC failsafe

MOT_ Parameters

MOT_YAW_HEADROOM: Matrix Yaw Min

Note: This parameter is for advanced users

Yaw control is given at least this pwm in microseconds range

Range

Units

0 to 500

PWM in microseconds

MOT_THST_EXPO: Thrust Curve Expo

Note: This parameter is for advanced users

Motor thrust curve exponent (0.0 for linear to 1.0 for second order curve)

Range

-1.0 to 1.0

MOT_SPIN_MAX: Motor Spin maximum

Note: This parameter is for advanced users

Point at which the thrust saturates expressed as a number from 0 to 1 in the entire output range

Values

Value

Meaning

0.9

Low

0.95

Default

1.0

High

MOT_BAT_VOLT_MAX: Battery voltage compensation maximum voltage

Note: This parameter is for advanced users

Battery voltage compensation maximum voltage (voltage above this will have no additional scaling effect on thrust). Recommend 4.2 * cell count, 0 = Disabled

Range

Units

6 to 53

volt

MOT_BAT_VOLT_MIN: Battery voltage compensation minimum voltage

Note: This parameter is for advanced users

Battery voltage compensation minimum voltage (voltage below this will have no additional scaling effect on thrust). Recommend 3.3 * cell count, 0 = Disabled

Range

Units

6 to 42

volt

MOT_BAT_CURR_MAX: Motor Current Max

Note: This parameter is for advanced users

Maximum current over which maximum throttle is limited (0 = Disabled)

Range

Units

0 to 200

ampere

MOT_PWM_TYPE: Output PWM type

Note: This parameter is for advanced users
Note: Reboot required after change

This selects the output PWM type, allowing for normal PWM continuous output, OneShot, brushed or DShot motor output.PWMRange and PWMAngle are PWM special/rare cases for ESCs that dont calibrate normally (some Sub motors) or where each ESC must have its PWM range set individually using the Servo params instead of PWM_MIN/MAX parameters.

Values

Value

Meaning

0

Normal

1

OneShot

2

OneShot125

3

Brushed

4

DShot150

5

DShot300

6

DShot600

7

DShot1200

8

PWMRange

9

PWMAngle

MOT_PWM_MIN: PWM output minimum

Note: This parameter is for advanced users

This sets the min PWM output value in microseconds that will ever be output to the motors

Range

Units

0 to 2000

PWM in microseconds

MOT_PWM_MAX: PWM output maximum

Note: This parameter is for advanced users

This sets the max PWM value in microseconds that will ever be output to the motors

Range

Units

0 to 2000

PWM in microseconds

MOT_SPIN_MIN: Motor Spin minimum

Note: This parameter is for advanced users

Point at which the thrust starts expressed as a number from 0 to 1 in the entire output range. Should be higher than MOT_SPIN_ARM.

Values

Value

Meaning

0.0

Low

0.15

Default

0.25

High

MOT_SPIN_ARM: Motor Spin armed

Note: This parameter is for advanced users

Point at which the motors start to spin expressed as a number from 0 to 1 in the entire output range. Should be lower than MOT_SPIN_MIN.

Values

Value

Meaning

0.0

Low

0.1

Default

0.2

High

MOT_BAT_CURR_TC: Motor Current Max Time Constant

Note: This parameter is for advanced users

Time constant used to limit the maximum current

Range

Units

0 to 10

seconds

MOT_THST_HOVER: Thrust Hover Value

Note: This parameter is for advanced users

Motor thrust needed to hover expressed as a number from 0 to 1

Range

0.2 to 0.8

MOT_HOVER_LEARN: Hover Value Learning

Note: This parameter is for advanced users

Enable/Disable automatic learning of hover throttle

Values

Value

Meaning

0

Disabled

1

Learn

2

Learn and Save

MOT_SAFE_DISARM: Motor PWM output disabled when disarmed

Note: This parameter is for advanced users

Disables motor PWM output when disarmed

Values

Value

Meaning

0

PWM enabled while disarmed

1

PWM disabled while disarmed

MOT_YAW_SV_ANGLE: Yaw Servo Max Lean Angle

Yaw servo's maximum lean angle (Tricopter only)

Increment

Range

Units

1

5 to 80

degrees

MOT_SPOOL_TIME: Spool up time

Note: This parameter is for advanced users

Time in seconds to spool up the motors from zero to min throttle.

Increment

Range

Units

0.1

0.05 to 2

seconds

MOT_BOOST_SCALE: Motor boost scale

Note: This parameter is for advanced users

Booster motor output scaling factor vs main throttle. The output to the BoostThrottle servo will be the main throttle times this scaling factor. A higher scaling factor will put more of the load on the booster motor. A value of 1 will set the BoostThrottle equal to the main throttle.

Increment

Range

0.1

0 to 5

MOT_BAT_IDX: Battery compensation index

Note: This parameter is for advanced users

Which battery monitor should be used for doing compensation

Values

Value

Meaning

0

First battery

1

Second battery

MOT_SLEW_UP_TIME: Output slew time for increasing throttle

Note: This parameter is for advanced users

Time in seconds to slew output from zero to full. This is used to limit the rate at which output can change. Range is constrained between 0 and 0.5.

Increment

Range

Units

0.001

0 to .5

seconds

MOT_SLEW_DN_TIME: Output slew time for decreasing throttle

Note: This parameter is for advanced users

Time in seconds to slew output from full to zero. This is used to limit the rate at which output can change. Range is constrained between 0 and 0.5.

Increment

Range

Units

0.001

0 to .5

seconds

MOT_SAFE_TIME: Time taken to disable and enable the motor PWM output when disarmed and armed.

Note: This parameter is for advanced users

Time taken to disable and enable the motor PWM output when disarmed and armed.

Increment

Range

Units

0.001

0 to 5

seconds

MOT_OPTIONS: Motor options

Note: This parameter is for advanced users

Motor options

Bitmask

Bit

Meaning

0

Voltage compensation uses raw voltage

MOT_SPOOL_TIM_DN: Spool down time

Note: This parameter is for advanced users

Time taken to spool down the motors from min to zero throttle. If set to 0 then SPOOL_TIME is used instead.

Increment

Range

Units

0.001

0 to 2

seconds

MSP Parameters

MSP_OSD_NCELLS: Cell count override

Used for average cell voltage calculation

Values

Value

Meaning

0

Auto

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

MSP_OPTIONS: MSP OSD Options

A bitmask to set some MSP specific options: EnableTelemetryMode-allows "push" mode telemetry when only rx line of OSD ic connected to autopilot, EnableBTFLFonts-uses indexes corresponding to Betaflight fonts if OSD uses those instead of ArduPilot fonts.

Bitmask

Bit

Meaning

0

EnableTelemetryMode

1

unused

2

EnableBTFLFonts

NET_ Parameters

NET_ENABLE: Networking Enable

Note: This parameter is for advanced users
Note: Reboot required after change

Networking Enable

Values

Value

Meaning

0

Disable

1

Enable

NET_NETMASK: IP Subnet mask

Note: This parameter is for advanced users
Note: Reboot required after change

Allows setting static subnet mask. The value is a count of consecutive bits. Examples: 24 = 255.255.255.0, 16 = 255.255.0.0

Range

0 to 32

NET_DHCP: DHCP client

Note: This parameter is for advanced users
Note: Reboot required after change

Enable/Disable DHCP client

Values

Value

Meaning

0

Disable

1

Enable

NET_TESTS: Test enable flags

Note: This parameter is for advanced users
Note: Reboot required after change

Enable/Disable networking tests

Bitmask

Bit

Meaning

0

UDP echo test

1

TCP echo test

2

TCP discard test

3

TCP reflect test

NET_OPTIONS: Networking options

Note: This parameter is for advanced users
Note: Reboot required after change

Networking options

Bitmask

Bit

Meaning

0

EnablePPP Ethernet gateway

1

Enable CAN1 multicast gateway

2

Enable CAN2 multicast gateway

NET_GWADDR Parameters

NET_GWADDR0: IPv4 Address 1st byte

Note: Reboot required after change

IPv4 address. Example: 192.xxx.xxx.xxx

Range

0 to 255

NET_GWADDR1: IPv4 Address 2nd byte

Note: Reboot required after change

IPv4 address. Example: xxx.168.xxx.xxx

Range

0 to 255

NET_GWADDR2: IPv4 Address 3rd byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.13.xxx

Range

0 to 255

NET_GWADDR3: IPv4 Address 4th byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.xxx.14

Range

0 to 255

NET_IPADDR Parameters

NET_IPADDR0: IPv4 Address 1st byte

Note: Reboot required after change

IPv4 address. Example: 192.xxx.xxx.xxx

Range

0 to 255

NET_IPADDR1: IPv4 Address 2nd byte

Note: Reboot required after change

IPv4 address. Example: xxx.168.xxx.xxx

Range

0 to 255

NET_IPADDR2: IPv4 Address 3rd byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.13.xxx

Range

0 to 255

NET_IPADDR3: IPv4 Address 4th byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.xxx.14

Range

0 to 255

NET_MACADDR Parameters

NET_MACADDR0: MAC Address 1st byte

Note: This parameter is for advanced users
Note: Reboot required after change

MAC address 1st byte

Range

0 to 255

NET_MACADDR1: MAC Address 2nd byte

Note: This parameter is for advanced users
Note: Reboot required after change

MAC address 2nd byte

Range

0 to 255

NET_MACADDR2: MAC Address 3rd byte

Note: This parameter is for advanced users
Note: Reboot required after change

MAC address 3rd byte

Range

0 to 255

NET_MACADDR3: MAC Address 4th byte

Note: This parameter is for advanced users
Note: Reboot required after change

MAC address 4th byte

Range

0 to 255

NET_MACADDR4: MAC Address 5th byte

Note: This parameter is for advanced users
Note: Reboot required after change

MAC address 5th byte

Range

0 to 255

NET_MACADDR5: MAC Address 6th byte

Note: This parameter is for advanced users
Note: Reboot required after change

MAC address 6th byte

Range

0 to 255

NET_P1_ Parameters

NET_P1_TYPE: Port type

Note: This parameter is for advanced users
Note: Reboot required after change

Port type for network serial port. For the two client types a valid destination IP address must be set. For the two server types either 0.0.0.0 or a local address can be used. The UDP client type will use broadcast if the IP is set to 255.255.255.255 and will use UDP multicast if the IP is in the multicast address range.

Values

Value

Meaning

0

Disabled

1

UDP client

2

UDP server

3

TCP client

4

TCP server

NET_P1_PROTOCOL: Protocol

Note: This parameter is for advanced users
Note: Reboot required after change

Networked serial port protocol

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

NET_P1_PORT: Port number

Note: This parameter is for advanced users
Note: Reboot required after change

Port number

Range

0 to 65535

NET_P1_IP Parameters

NET_P1_IP0: IPv4 Address 1st byte

Note: Reboot required after change

IPv4 address. Example: 192.xxx.xxx.xxx

Range

0 to 255

NET_P1_IP1: IPv4 Address 2nd byte

Note: Reboot required after change

IPv4 address. Example: xxx.168.xxx.xxx

Range

0 to 255

NET_P1_IP2: IPv4 Address 3rd byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.13.xxx

Range

0 to 255

NET_P1_IP3: IPv4 Address 4th byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.xxx.14

Range

0 to 255

NET_P2_ Parameters

NET_P2_TYPE: Port type

Note: This parameter is for advanced users
Note: Reboot required after change

Port type for network serial port. For the two client types a valid destination IP address must be set. For the two server types either 0.0.0.0 or a local address can be used. The UDP client type will use broadcast if the IP is set to 255.255.255.255 and will use UDP multicast if the IP is in the multicast address range.

Values

Value

Meaning

0

Disabled

1

UDP client

2

UDP server

3

TCP client

4

TCP server

NET_P2_PROTOCOL: Protocol

Note: This parameter is for advanced users
Note: Reboot required after change

Networked serial port protocol

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

NET_P2_PORT: Port number

Note: This parameter is for advanced users
Note: Reboot required after change

Port number

Range

0 to 65535

NET_P2_IP Parameters

NET_P2_IP0: IPv4 Address 1st byte

Note: Reboot required after change

IPv4 address. Example: 192.xxx.xxx.xxx

Range

0 to 255

NET_P2_IP1: IPv4 Address 2nd byte

Note: Reboot required after change

IPv4 address. Example: xxx.168.xxx.xxx

Range

0 to 255

NET_P2_IP2: IPv4 Address 3rd byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.13.xxx

Range

0 to 255

NET_P2_IP3: IPv4 Address 4th byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.xxx.14

Range

0 to 255

NET_P3_ Parameters

NET_P3_TYPE: Port type

Note: This parameter is for advanced users
Note: Reboot required after change

Port type for network serial port. For the two client types a valid destination IP address must be set. For the two server types either 0.0.0.0 or a local address can be used. The UDP client type will use broadcast if the IP is set to 255.255.255.255 and will use UDP multicast if the IP is in the multicast address range.

Values

Value

Meaning

0

Disabled

1

UDP client

2

UDP server

3

TCP client

4

TCP server

NET_P3_PROTOCOL: Protocol

Note: This parameter is for advanced users
Note: Reboot required after change

Networked serial port protocol

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

NET_P3_PORT: Port number

Note: This parameter is for advanced users
Note: Reboot required after change

Port number

Range

0 to 65535

NET_P3_IP Parameters

NET_P3_IP0: IPv4 Address 1st byte

Note: Reboot required after change

IPv4 address. Example: 192.xxx.xxx.xxx

Range

0 to 255

NET_P3_IP1: IPv4 Address 2nd byte

Note: Reboot required after change

IPv4 address. Example: xxx.168.xxx.xxx

Range

0 to 255

NET_P3_IP2: IPv4 Address 3rd byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.13.xxx

Range

0 to 255

NET_P3_IP3: IPv4 Address 4th byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.xxx.14

Range

0 to 255

NET_P4_ Parameters

NET_P4_TYPE: Port type

Note: This parameter is for advanced users
Note: Reboot required after change

Port type for network serial port. For the two client types a valid destination IP address must be set. For the two server types either 0.0.0.0 or a local address can be used. The UDP client type will use broadcast if the IP is set to 255.255.255.255 and will use UDP multicast if the IP is in the multicast address range.

Values

Value

Meaning

0

Disabled

1

UDP client

2

UDP server

3

TCP client

4

TCP server

NET_P4_PROTOCOL: Protocol

Note: This parameter is for advanced users
Note: Reboot required after change

Networked serial port protocol

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

NET_P4_PORT: Port number

Note: This parameter is for advanced users
Note: Reboot required after change

Port number

Range

0 to 65535

NET_P4_IP Parameters

NET_P4_IP0: IPv4 Address 1st byte

Note: Reboot required after change

IPv4 address. Example: 192.xxx.xxx.xxx

Range

0 to 255

NET_P4_IP1: IPv4 Address 2nd byte

Note: Reboot required after change

IPv4 address. Example: xxx.168.xxx.xxx

Range

0 to 255

NET_P4_IP2: IPv4 Address 3rd byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.13.xxx

Range

0 to 255

NET_P4_IP3: IPv4 Address 4th byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.xxx.14

Range

0 to 255

NET_REMPPP_IP Parameters

NET_REMPPP_IP0: IPv4 Address 1st byte

Note: Reboot required after change

IPv4 address. Example: 192.xxx.xxx.xxx

Range

0 to 255

NET_REMPPP_IP1: IPv4 Address 2nd byte

Note: Reboot required after change

IPv4 address. Example: xxx.168.xxx.xxx

Range

0 to 255

NET_REMPPP_IP2: IPv4 Address 3rd byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.13.xxx

Range

0 to 255

NET_REMPPP_IP3: IPv4 Address 4th byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.xxx.14

Range

0 to 255

NET_TEST_IP Parameters

NET_TEST_IP0: IPv4 Address 1st byte

Note: Reboot required after change

IPv4 address. Example: 192.xxx.xxx.xxx

Range

0 to 255

NET_TEST_IP1: IPv4 Address 2nd byte

Note: Reboot required after change

IPv4 address. Example: xxx.168.xxx.xxx

Range

0 to 255

NET_TEST_IP2: IPv4 Address 3rd byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.13.xxx

Range

0 to 255

NET_TEST_IP3: IPv4 Address 4th byte

Note: Reboot required after change

IPv4 address. Example: xxx.xxx.xxx.14

Range

0 to 255

NMEA_ Parameters

NMEA_RATE_MS: NMEA Output rate

NMEA Output rate. This controls the interval at which all the enabled NMEA messages are sent. Most NMEA systems expect 100ms (10Hz) or slower.

Increment

Range

Units

1

20 to 2000

milliseconds

NMEA_MSG_EN: Messages Enable bitmask

This is a bitmask of enabled NMEA messages. All messages will be sent consecutively at the same rate interval

Bitmask

Bit

Meaning

0

GPGGA

1

GPRMC

2

PASHR

NTF_ Parameters

NTF_LED_BRIGHT: LED Brightness

Note: This parameter is for advanced users

Select the RGB LED brightness level. When USB is connected brightness will never be higher than low regardless of the setting.

Values

Value

Meaning

0

Off

1

Low

2

Medium

3

High

NTF_BUZZ_TYPES: Buzzer Driver Types

Note: This parameter is for advanced users

Controls what types of Buzzer will be enabled

Bitmask

Bit

Meaning

0

Built-in buzzer

1

DShot

2

DroneCAN

NTF_LED_OVERRIDE: Specifies colour source for the RGBLed

Note: This parameter is for advanced users

Specifies the source for the colours and brightness for the LED. OutbackChallenge conforms to the MedicalExpress (https://uavchallenge.org/medical-express/) rules, essentially "Green" is disarmed (safe-to-approach), "Red" is armed (not safe-to-approach). Traffic light is a simplified color set, red when armed, yellow when the safety switch is not surpressing outputs (but disarmed), and green when outputs are surpressed and disarmed, the LED will blink faster if disarmed and failing arming checks.

Values

Value

Meaning

0

Standard

1

MAVLink/Scripting/AP_Periph

2

OutbackChallenge

3

TrafficLight

NTF_DISPLAY_TYPE: Type of on-board I2C display

Note: This parameter is for advanced users

This sets up the type of on-board I2C display. Disabled by default.

Values

Value

Meaning

0

Disable

1

ssd1306

2

sh1106

10

SITL

NTF_OREO_THEME: OreoLED Theme

Note: This parameter is for advanced users

Enable/Disable Solo Oreo LED driver, 0 to disable, 1 for Aircraft theme, 2 for Rover theme

Values

Value

Meaning

0

Disabled

1

Aircraft

2

Rover

NTF_BUZZ_PIN: Buzzer pin

Note: This parameter is for advanced users

Enables to connect active buzzer to arbitrary pin. Requires 3-pin buzzer or additional MOSFET! Some the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

NTF_LED_TYPES: LED Driver Types

Note: This parameter is for advanced users

Controls what types of LEDs will be enabled

Bitmask

Bit

Meaning

0

Built-in LED

1

Internal ToshibaLED

2

External ToshibaLED

3

External PCA9685

4

Oreo LED

5

DroneCAN

6

NCP5623 External

7

NCP5623 Internal

8

NeoPixel

9

ProfiLED

10

Scripting

11

DShot

12

ProfiLED_SPI

13

LP5562 External

14

LP5562 Internal

15

IS31FL3195 External

16

IS31FL3195 Internal

17

DiscreteRGB

18

NeoPixelRGB

19

ProfiLED_IOMCU

NTF_BUZZ_ON_LVL: Buzzer-on pin logic level

Note: This parameter is for advanced users

Specifies pin level that indicates buzzer should play

Values

Value

Meaning

0

LowIsOn

1

HighIsOn

NTF_BUZZ_VOLUME: Buzzer volume

Control the volume of the buzzer

Range

Units

0 to 100

percent

NTF_LED_LEN: Serial LED String Length

Note: This parameter is for advanced users
Note: Reboot required after change

The number of Serial LED's to use for notifications (NeoPixel's and ProfiLED)

Range

1 to 32

OA_ Parameters

OA_TYPE: Object Avoidance Path Planning algorithm to use

Enabled/disable path planning around obstacles

Values

Value

Meaning

0

Disabled

1

BendyRuler

2

Dijkstra

3

Dijkstra with BendyRuler

OA_MARGIN_MAX: Object Avoidance wide margin distance

Object Avoidance will ignore objects more than this many meters from vehicle

Increment

Range

Units

1

0.1 to 100

meters

OA_OPTIONS: Options while recovering from Object Avoidance

Bitmask which will govern vehicles behaviour while recovering from Obstacle Avoidance (i.e Avoidance is turned off after the path ahead is clear).

Bitmask

Bit

Meaning

1

log Dijkstra points

2

Allow fast waypoints (Dijkastras only)

OA_BR_ Parameters

OA_BR_LOOKAHEAD: Object Avoidance look ahead distance maximum

Object Avoidance will look this many meters ahead of vehicle

Increment

Range

Units

1

1 to 100

meters

OA_BR_CONT_RATIO: Obstacle Avoidance margin ratio for BendyRuler to change bearing significantly

BendyRuler will avoid changing bearing unless ratio of previous margin from obstacle (or fence) to present calculated margin is atleast this much.

Increment

Range

0.1

1.1 to 2

OA_BR_CONT_ANGLE: BendyRuler's bearing change resistance threshold angle

BendyRuler will resist changing current bearing if the change in bearing is over this angle

Increment

Range

5

20 to 180

OA_BR_TYPE: Type of BendyRuler

BendyRuler will search for clear path along the direction defined by this parameter

Values

Value

Meaning

1

Horizontal search

2

Vertical search

OA_DB_ Parameters

OA_DB_SIZE: OADatabase maximum number of points

Note: This parameter is for advanced users
Note: Reboot required after change

OADatabase maximum number of points. Set to 0 to disable the OA Database. Larger means more points but is more cpu intensive to process

Range

0 to 10000

OA_DB_EXPIRE: OADatabase item timeout

Note: This parameter is for advanced users

OADatabase item timeout. The time an item will linger without any updates before it expires. Zero means never expires which is useful for a sent-once static environment but terrible for dynamic ones.

Increment

Range

Units

1

0 to 127

seconds

OA_DB_QUEUE_SIZE: OADatabase queue maximum number of points

Note: This parameter is for advanced users
Note: Reboot required after change

OADatabase queue maximum number of points. This in an input buffer size. Larger means it can handle larger bursts of incoming data points to filter into the database. No impact on cpu, only RAM. Recommend larger for faster datalinks or for sensors that generate a lot of data.

Range

1 to 200

OA_DB_OUTPUT: OADatabase output level

Note: This parameter is for advanced users

OADatabase output level to configure which database objects are sent to the ground station. All data is always available internally for avoidance algorithms.

Values

Value

Meaning

0

Disabled

1

Send only HIGH importance items

2

Send HIGH and NORMAL importance items

3

Send all items

OA_DB_BEAM_WIDTH: OADatabase beam width

Note: This parameter is for advanced users
Note: Reboot required after change

Beam width of incoming lidar data

Range

Units

1 to 10

degrees

OA_DB_RADIUS_MIN: OADatabase Minimum radius

Note: This parameter is for advanced users

Minimum radius of objects held in database

Range

Units

0 to 10

meters

OA_DB_DIST_MAX: OADatabase Distance Maximum

Note: This parameter is for advanced users

Maximum distance of objects held in database. Set to zero to disable the limits

Range

Units

0 to 10

meters

OA_DB_ALT_MIN: OADatabase minimum altitude above home before storing obstacles

Note: This parameter is for advanced users

OADatabase will reject obstacles if vehicle's altitude above home is below this parameter, in a 3 meter radius around home. Set 0 to disable this feature.

Range

Units

0 to 4

meters

OSD Parameters

OSD_TYPE: OSD type

Note: Reboot required after change

OSD type. TXONLY makes the OSD parameter selection available to other modules even if there is no native OSD support on the board, for instance CRSF.

Values

Value

Meaning

0

None

1

MAX7456

2

SITL

3

MSP

4

TXONLY

5

MSP_DISPLAYPORT

OSD_CHAN: Screen switch transmitter channel

This sets the channel used to switch different OSD screens.

Values

Value

Meaning

0

Disable

5

Chan5

6

Chan6

7

Chan7

8

Chan8

9

Chan9

10

Chan10

11

Chan11

12

Chan12

13

Chan13

14

Chan14

15

Chan15

16

Chan16

OSD_SW_METHOD: Screen switch method

This sets the method used to switch different OSD screens.

Values

Value

Meaning

0

switch to next screen if channel value was changed

1

select screen based on pwm ranges specified for each screen

2

switch to next screen after low to high transition and every 1s while channel value is high

OSD_OPTIONS: OSD Options

This sets options that change the display

Bitmask

Bit

Meaning

0

UseDecimalPack

1

InvertedWindArrow

2

InvertedAHRoll

3

Convert feet to miles at 5280ft instead of 10000ft

4

DisableCrosshair

5

TranslateArrows

6

AviationStyleAH

7

Prefix LQ with RF Mode

OSD_FONT: OSD Font

Note: Reboot required after change

This sets which OSD font to use. It is an integer from 0 to the number of fonts available

OSD_V_OFFSET: OSD vertical offset

Note: Reboot required after change

Sets vertical offset of the osd inside image

Range

0 to 31

OSD_H_OFFSET: OSD horizontal offset

Note: Reboot required after change

Sets horizontal offset of the osd inside image

Range

0 to 63

OSD_W_RSSI: RSSI warn level (in %)

Set level at which RSSI item will flash (in positive % or negative dBm values as applicable). 30% or -100dBm are defaults.

Range

-128 to 100

OSD_W_NSAT: NSAT warn level

Set level at which NSAT item will flash

Range

1 to 30

OSD_W_BATVOLT: BAT_VOLT warn level

Set level at which BAT_VOLT item will flash

Range

0 to 100

OSD_UNITS: Display Units

Sets the units to use in displaying items

Values

Value

Meaning

0

Metric

1

Imperial

2

SI

3

Aviation

OSD_MSG_TIME: Message display duration in seconds

Sets message duration seconds

Range

1 to 20

OSD_ARM_SCR: Arm screen

Screen to be shown on Arm event. Zero to disable the feature.

Range

0 to 4

OSD_DSARM_SCR: Disarm screen

Screen to be shown on disarm event. Zero to disable the feature.

Range

0 to 4

OSD_FS_SCR: Failsafe screen

Screen to be shown on failsafe event. Zero to disable the feature.

Range

0 to 4

OSD_BTN_DELAY: Button delay

Note: This parameter is for advanced users

Debounce time in ms for stick commanded parameter navigation.

Range

0 to 3000

OSD_W_TERR: Terrain warn level

Set level below which TER_HGT item will flash. -1 disables.

Range

Units

-1 to 3000

meters

OSD_W_AVGCELLV: AVGCELLV warn level

Set level at which AVGCELLV item will flash

Range

0 to 100

OSD_CELL_COUNT: Battery cell count

Note: This parameter is for advanced users

Used for average cell voltage display. -1 disables, 0 uses cell count autodetection for well charged LIPO/LIION batteries at connection, other values manually select cell count used.

Increment

1

OSD_W_RESTVOLT: RESTVOLT warn level

Set level at which RESTVOLT item will flash

Range

0 to 100

OSD_W_ACRVOLT: Avg Cell Resting Volt warn level

Set level at which ACRVOLT item will flash

Range

0 to 100

OSD_SB_H_OFS: Sidebar horizontal offset

Extends the spacing between the sidebar elements by this amount of columns. Positive values increases the width to the right of the screen.

Range

0 to 20

OSD_SB_V_EXT: Sidebar vertical extension

Increase of vertical length of the sidebar itens by this amount of lines. Applied equally both above and below the default setting.

Range

0 to 10

OSD_TYPE2: OSD type 2

Note: Reboot required after change

OSD type 2. TXONLY makes the OSD parameter selection available to other modules even if there is no native OSD support on the board, for instance CRSF.

Values

Value

Meaning

0

None

1

MAX7456

2

SITL

3

MSP

4

TXONLY

5

MSP_DISPLAYPORT

OSD1_ Parameters

OSD1_ENABLE: Enable screen

Enable this screen

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_CHAN_MIN: Transmitter switch screen minimum pwm

This sets the PWM lower limit for this screen

Range

900 to 2100

OSD1_CHAN_MAX: Transmitter switch screen maximum pwm

This sets the PWM upper limit for this screen

Range

900 to 2100

OSD1_ALTITUDE_EN: ALTITUDE_EN

Enables display of altitude AGL

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ALTITUDE_X: ALTITUDE_X

Horizontal position on screen

Range

0 to 59

OSD1_ALTITUDE_Y: ALTITUDE_Y

Vertical position on screen

Range

0 to 21

OSD1_BAT_VOLT_EN: BATVOLT_EN

Displays main battery voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_BAT_VOLT_X: BATVOLT_X

Horizontal position on screen

Range

0 to 59

OSD1_BAT_VOLT_Y: BATVOLT_Y

Vertical position on screen

Range

0 to 21

OSD1_RSSI_EN: RSSI_EN

Displays RC signal strength

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_RSSI_X: RSSI_X

Horizontal position on screen

Range

0 to 59

OSD1_RSSI_Y: RSSI_Y

Vertical position on screen

Range

0 to 21

OSD1_CURRENT_EN: CURRENT_EN

Displays main battery current

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_CURRENT_X: CURRENT_X

Horizontal position on screen

Range

0 to 59

OSD1_CURRENT_Y: CURRENT_Y

Vertical position on screen

Range

0 to 21

OSD1_BATUSED_EN: BATUSED_EN

Displays primary battery mAh consumed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_BATUSED_X: BATUSED_X

Horizontal position on screen

Range

0 to 59

OSD1_BATUSED_Y: BATUSED_Y

Vertical position on screen

Range

0 to 21

OSD1_SATS_EN: SATS_EN

Displays number of acquired satellites

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_SATS_X: SATS_X

Horizontal position on screen

Range

0 to 59

OSD1_SATS_Y: SATS_Y

Vertical position on screen

Range

0 to 21

OSD1_FLTMODE_EN: FLTMODE_EN

Displays flight mode

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_FLTMODE_X: FLTMODE_X

Horizontal position on screen

Range

0 to 59

OSD1_FLTMODE_Y: FLTMODE_Y

Vertical position on screen

Range

0 to 21

OSD1_MESSAGE_EN: MESSAGE_EN

Displays Mavlink messages

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_MESSAGE_X: MESSAGE_X

Horizontal position on screen

Range

0 to 59

OSD1_MESSAGE_Y: MESSAGE_Y

Vertical position on screen

Range

0 to 21

OSD1_GSPEED_EN: GSPEED_EN

Displays GPS ground speed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_GSPEED_X: GSPEED_X

Horizontal position on screen

Range

0 to 59

OSD1_GSPEED_Y: GSPEED_Y

Vertical position on screen

Range

0 to 21

OSD1_HORIZON_EN: HORIZON_EN

Displays artificial horizon

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_HORIZON_X: HORIZON_X

Horizontal position on screen

Range

0 to 59

OSD1_HORIZON_Y: HORIZON_Y

Vertical position on screen

Range

0 to 21

OSD1_HOME_EN: HOME_EN

Displays distance and relative direction to HOME

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_HOME_X: HOME_X

Horizontal position on screen

Range

0 to 59

OSD1_HOME_Y: HOME_Y

Vertical position on screen

Range

0 to 21

OSD1_HEADING_EN: HEADING_EN

Displays heading

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_HEADING_X: HEADING_X

Horizontal position on screen

Range

0 to 59

OSD1_HEADING_Y: HEADING_Y

Vertical position on screen

Range

0 to 21

OSD1_THROTTLE_EN: THROTTLE_EN

Displays actual throttle percentage being sent to motor(s)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_THROTTLE_X: THROTTLE_X

Horizontal position on screen

Range

0 to 59

OSD1_THROTTLE_Y: THROTTLE_Y

Vertical position on screen

Range

0 to 21

OSD1_COMPASS_EN: COMPASS_EN

Enables display of compass rose

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_COMPASS_X: COMPASS_X

Horizontal position on screen

Range

0 to 59

OSD1_COMPASS_Y: COMPASS_Y

Vertical position on screen

Range

0 to 21

OSD1_WIND_EN: WIND_EN

Displays wind speed and relative direction, on Rover this is the apparent wind speed and direction from the windvane, if fitted

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_WIND_X: WIND_X

Horizontal position on screen

Range

0 to 59

OSD1_WIND_Y: WIND_Y

Vertical position on screen

Range

0 to 21

OSD1_ASPEED_EN: ASPEED_EN

Displays airspeed value being used by TECS (fused value)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ASPEED_X: ASPEED_X

Horizontal position on screen

Range

0 to 59

OSD1_ASPEED_Y: ASPEED_Y

Vertical position on screen

Range

0 to 21

OSD1_VSPEED_EN: VSPEED_EN

Displays climb rate

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_VSPEED_X: VSPEED_X

Horizontal position on screen

Range

0 to 59

OSD1_VSPEED_Y: VSPEED_Y

Vertical position on screen

Range

0 to 21

OSD1_ESCTEMP_EN: ESCTEMP_EN

Displays highest temp of all active ESCs, or of a specific ECS if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ESCTEMP_X: ESCTEMP_X

Horizontal position on screen

Range

0 to 59

OSD1_ESCTEMP_Y: ESCTEMP_Y

Vertical position on screen

Range

0 to 21

OSD1_ESCRPM_EN: ESCRPM_EN

Displays highest rpm of all active ESCs, or of a specific ESC if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ESCRPM_X: ESCRPM_X

Horizontal position on screen

Range

0 to 59

OSD1_ESCRPM_Y: ESCRPM_Y

Vertical position on screen

Range

0 to 21

OSD1_ESCAMPS_EN: ESCAMPS_EN

Displays the current of the ESC with the highest rpm of all active ESCs, or of a specific ESC if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ESCAMPS_X: ESCAMPS_X

Horizontal position on screen

Range

0 to 59

OSD1_ESCAMPS_Y: ESCAMPS_Y

Vertical position on screen

Range

0 to 21

OSD1_GPSLAT_EN: GPSLAT_EN

Displays GPS latitude

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_GPSLAT_X: GPSLAT_X

Horizontal position on screen

Range

0 to 59

OSD1_GPSLAT_Y: GPSLAT_Y

Vertical position on screen

Range

0 to 21

OSD1_GPSLONG_EN: GPSLONG_EN

Displays GPS longitude

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_GPSLONG_X: GPSLONG_X

Horizontal position on screen

Range

0 to 59

OSD1_GPSLONG_Y: GPSLONG_Y

Vertical position on screen

Range

0 to 21

OSD1_ROLL_EN: ROLL_EN

Displays degrees of roll from level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ROLL_X: ROLL_X

Horizontal position on screen

Range

0 to 59

OSD1_ROLL_Y: ROLL_Y

Vertical position on screen

Range

0 to 21

OSD1_PITCH_EN: PITCH_EN

Displays degrees of pitch from level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_PITCH_X: PITCH_X

Horizontal position on screen

Range

0 to 59

OSD1_PITCH_Y: PITCH_Y

Vertical position on screen

Range

0 to 21

OSD1_TEMP_EN: TEMP_EN

Displays temperature reported by primary barometer

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_TEMP_X: TEMP_X

Horizontal position on screen

Range

0 to 59

OSD1_TEMP_Y: TEMP_Y

Vertical position on screen

Range

0 to 21

OSD1_HDOP_EN: HDOP_EN

Displays Horizontal Dilution Of Position

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_HDOP_X: HDOP_X

Horizontal position on screen

Range

0 to 59

OSD1_HDOP_Y: HDOP_Y

Vertical position on screen

Range

0 to 21

OSD1_WAYPOINT_EN: WAYPOINT_EN

Displays bearing and distance to next waypoint

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_WAYPOINT_X: WAYPOINT_X

Horizontal position on screen

Range

0 to 59

OSD1_WAYPOINT_Y: WAYPOINT_Y

Vertical position on screen

Range

0 to 21

OSD1_XTRACK_EN: XTRACK_EN

Displays crosstrack error

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_XTRACK_X: XTRACK_X

Horizontal position on screen

Range

0 to 59

OSD1_XTRACK_Y: XTRACK_Y

Vertical position on screen

Range

0 to 21

OSD1_DIST_EN: DIST_EN

Displays total distance flown

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_DIST_X: DIST_X

Horizontal position on screen

Range

0 to 59

OSD1_DIST_Y: DIST_Y

Vertical position on screen

Range

0 to 21

OSD1_STATS_EN: STATS_EN

Displays flight stats

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_STATS_X: STATS_X

Horizontal position on screen

Range

0 to 59

OSD1_STATS_Y: STATS_Y

Vertical position on screen

Range

0 to 21

OSD1_FLTIME_EN: FLTIME_EN

Displays total flight time

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_FLTIME_X: FLTIME_X

Horizontal position on screen

Range

0 to 59

OSD1_FLTIME_Y: FLTIME_Y

Vertical position on screen

Range

0 to 21

OSD1_CLIMBEFF_EN: CLIMBEFF_EN

Displays climb efficiency (climb rate/current)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_CLIMBEFF_X: CLIMBEFF_X

Horizontal position on screen

Range

0 to 59

OSD1_CLIMBEFF_Y: CLIMBEFF_Y

Vertical position on screen

Range

0 to 21

OSD1_EFF_EN: EFF_EN

Displays flight efficiency (mAh/km or /mi)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_EFF_X: EFF_X

Horizontal position on screen

Range

0 to 59

OSD1_EFF_Y: EFF_Y

Vertical position on screen

Range

0 to 21

OSD1_BTEMP_EN: BTEMP_EN

Displays temperature reported by secondary barometer

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_BTEMP_X: BTEMP_X

Horizontal position on screen

Range

0 to 59

OSD1_BTEMP_Y: BTEMP_Y

Vertical position on screen

Range

0 to 21

OSD1_ATEMP_EN: ATEMP_EN

Displays temperature reported by primary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ATEMP_X: ATEMP_X

Horizontal position on screen

Range

0 to 59

OSD1_ATEMP_Y: ATEMP_Y

Vertical position on screen

Range

0 to 21

OSD1_BAT2_VLT_EN: BAT2VLT_EN

Displays battery2 voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_BAT2_VLT_X: BAT2VLT_X

Horizontal position on screen

Range

0 to 59

OSD1_BAT2_VLT_Y: BAT2VLT_Y

Vertical position on screen

Range

0 to 21

OSD1_BAT2USED_EN: BAT2USED_EN

Displays secondary battery mAh consumed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_BAT2USED_X: BAT2USED_X

Horizontal position on screen

Range

0 to 59

OSD1_BAT2USED_Y: BAT2USED_Y

Vertical position on screen

Range

0 to 21

OSD1_ASPD2_EN: ASPD2_EN

Displays airspeed reported directly from secondary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ASPD2_X: ASPD2_X

Horizontal position on screen

Range

0 to 59

OSD1_ASPD2_Y: ASPD2_Y

Vertical position on screen

Range

0 to 21

OSD1_ASPD1_EN: ASPD1_EN

Displays airspeed reported directly from primary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ASPD1_X: ASPD1_X

Horizontal position on screen

Range

0 to 59

OSD1_ASPD1_Y: ASPD1_Y

Vertical position on screen

Range

0 to 21

OSD1_CLK_EN: CLK_EN

Displays a clock panel based on AP_RTC local time

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_CLK_X: CLK_X

Horizontal position on screen

Range

0 to 59

OSD1_CLK_Y: CLK_Y

Vertical position on screen

Range

0 to 21

OSD1_SIDEBARS_EN: SIDEBARS_EN

Displays artificial horizon side bars

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_SIDEBARS_X: SIDEBARS_X

Horizontal position on screen

Range

0 to 59

OSD1_SIDEBARS_Y: SIDEBARS_Y

Vertical position on screen

Range

0 to 21

OSD1_CRSSHAIR_EN: CRSSHAIR_EN

Displays artificial horizon crosshair (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_CRSSHAIR_X: CRSSHAIR_X

Horizontal position on screen (MSP OSD only)

Range

0 to 59

OSD1_CRSSHAIR_Y: CRSSHAIR_Y

Vertical position on screen (MSP OSD only)

Range

0 to 21

OSD1_HOMEDIST_EN: HOMEDIST_EN

Displays distance from HOME (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_HOMEDIST_X: HOMEDIST_X

Horizontal position on screen (MSP OSD only)

Range

0 to 59

OSD1_HOMEDIST_Y: HOMEDIST_Y

Vertical position on screen (MSP OSD only)

Range

0 to 21

OSD1_HOMEDIR_EN: HOMEDIR_EN

Displays relative direction to HOME (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_HOMEDIR_X: HOMEDIR_X

Horizontal position on screen

Range

0 to 59

OSD1_HOMEDIR_Y: HOMEDIR_Y

Vertical position on screen

Range

0 to 21

OSD1_POWER_EN: POWER_EN

Displays power (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_POWER_X: POWER_X

Horizontal position on screen

Range

0 to 59

OSD1_POWER_Y: POWER_Y

Vertical position on screen

Range

0 to 21

OSD1_CELLVOLT_EN: CELL_VOLT_EN

Displays average cell voltage (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_CELLVOLT_X: CELL_VOLT_X

Horizontal position on screen

Range

0 to 59

OSD1_CELLVOLT_Y: CELL_VOLT_Y

Vertical position on screen

Range

0 to 21

OSD1_BATTBAR_EN: BATT_BAR_EN

Displays battery usage bar (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_BATTBAR_X: BATT_BAR_X

Horizontal position on screen

Range

0 to 59

OSD1_BATTBAR_Y: BATT_BAR_Y

Vertical position on screen

Range

0 to 21

OSD1_ARMING_EN: ARMING_EN

Displays arming status (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ARMING_X: ARMING_X

Horizontal position on screen

Range

0 to 59

OSD1_ARMING_Y: ARMING_Y

Vertical position on screen

Range

0 to 21

OSD1_PLUSCODE_EN: PLUSCODE_EN

Displays pluscode (OLC) element

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_PLUSCODE_X: PLUSCODE_X

Horizontal position on screen

Range

0 to 59

OSD1_PLUSCODE_Y: PLUSCODE_Y

Vertical position on screen

Range

0 to 21

OSD1_CALLSIGN_EN: CALLSIGN_EN

Displays callsign from callsign.txt on microSD card

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_CALLSIGN_X: CALLSIGN_X

Horizontal position on screen

Range

0 to 59

OSD1_CALLSIGN_Y: CALLSIGN_Y

Vertical position on screen

Range

0 to 21

OSD1_CURRENT2_EN: CURRENT2_EN

Displays 2nd battery current

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_CURRENT2_X: CURRENT2_X

Horizontal position on screen

Range

0 to 59

OSD1_CURRENT2_Y: CURRENT2_Y

Vertical position on screen

Range

0 to 21

OSD1_VTX_PWR_EN: VTX_PWR_EN

Displays VTX Power

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_VTX_PWR_X: VTX_PWR_X

Horizontal position on screen

Range

0 to 59

OSD1_VTX_PWR_Y: VTX_PWR_Y

Vertical position on screen

Range

0 to 21

OSD1_TER_HGT_EN: TER_HGT_EN

Displays Height above terrain

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_TER_HGT_X: TER_HGT_X

Horizontal position on screen

Range

0 to 59

OSD1_TER_HGT_Y: TER_HGT_Y

Vertical position on screen

Range

0 to 21

OSD1_AVGCELLV_EN: AVGCELLV_EN

Displays average cell voltage. WARNING: this can be inaccurate if the cell count is not detected or set properly. If the the battery is far from fully charged the detected cell count might not be accurate if auto cell count detection is used (OSD_CELL_COUNT=0).

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_AVGCELLV_X: AVGCELLV_X

Horizontal position on screen

Range

0 to 59

OSD1_AVGCELLV_Y: AVGCELLV_Y

Vertical position on screen

Range

0 to 21

OSD1_RESTVOLT_EN: RESTVOLT_EN

Displays main battery resting voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_RESTVOLT_X: RESTVOLT_X

Horizontal position on screen

Range

0 to 59

OSD1_RESTVOLT_Y: RESTVOLT_Y

Vertical position on screen

Range

0 to 21

OSD1_FENCE_EN: FENCE_EN

Displays indication of fence enable and breach

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_FENCE_X: FENCE_X

Horizontal position on screen

Range

0 to 59

OSD1_FENCE_Y: FENCE_Y

Vertical position on screen

Range

0 to 21

OSD1_RNGF_EN: RNGF_EN

Displays a rangefinder's distance in cm

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_RNGF_X: RNGF_X

Horizontal position on screen

Range

0 to 59

OSD1_RNGF_Y: RNGF_Y

Vertical position on screen

Range

0 to 21

OSD1_ACRVOLT_EN: ACRVOLT_EN

Displays resting voltage for the average cell. WARNING: this can be inaccurate if the cell count is not detected or set properly. If the the battery is far from fully charged the detected cell count might not be accurate if auto cell count detection is used (OSD_CELL_COUNT=0).

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_ACRVOLT_X: ACRVOLT_X

Horizontal position on screen

Range

0 to 59

OSD1_ACRVOLT_Y: ACRVOLT_Y

Vertical position on screen

Range

0 to 21

OSD1_RPM_EN: RPM_EN

Displays main rotor revs/min

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_RPM_X: RPM_X

Horizontal position on screen

Range

0 to 29

OSD1_RPM_Y: RPM_Y

Vertical position on screen

Range

0 to 15

OSD1_TXT_RES: Sets the overlay text resolution (MSP DisplayPort only)

Sets the overlay text resolution for this screen to either SD 30x16 or HD 50x18/60x22 (MSP DisplayPort only)

Values

Value

Meaning

0

30x16

1

50x18

2

60x22

OSD1_FONT: Sets the font index for this screen (MSP DisplayPort only)

Sets the font index for this screen (MSP DisplayPort only)

Range

0 to 21

OSD1_RC_PWR_EN: RC_PWR_EN

Displays the RC link transmit (TX) power in mW or W, depending on level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_RC_PWR_X: RC_PWR_X

Horizontal position on screen

Range

0 to 59

OSD1_RC_PWR_Y: RC_PWR_Y

Vertical position on screen

Range

0 to 21

OSD1_RSSIDBM_EN: RSSIDBM_EN

Displays RC link signal strength in dBm

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_RSSIDBM_X: RSSIDBM_X

Horizontal position on screen

Range

0 to 59

OSD1_RSSIDBM_Y: RSSIDBM_Y

Vertical position on screen

Range

0 to 21

OSD1_RC_SNR_EN: RC_SNR_EN

Displays RC link signal to noise ratio in dB

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_RC_SNR_X: RC_SNR_X

Horizontal position on screen

Range

0 to 59

OSD1_RC_SNR_Y: RC_SNR_Y

Vertical position on screen

Range

0 to 21

OSD1_RC_ANT_EN: RC_ANT_EN

Displays the current RC link active antenna

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_RC_ANT_X: RC_ANT_X

Horizontal position on screen

Range

0 to 59

OSD1_RC_ANT_Y: RC_ANT_Y

Vertical position on screen

Range

0 to 21

OSD1_RC_LQ_EN: RC_LQ_EN

Displays the RC link quality (uplink, 0 to 100%) and also RF mode if bit 7 of OSD_OPTIONS is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD1_RC_LQ_X: RC_LQ_X

Horizontal position on screen

Range

0 to 59

OSD1_RC_LQ_Y: RC_LQ_Y

Vertical position on screen

Range

0 to 21

OSD1_ESC_IDX: ESC_IDX

Index of the ESC to use for displaying ESC information. 0 means use the ESC with the highest value.

Range

0 to 32

OSD2_ Parameters

OSD2_ENABLE: Enable screen

Enable this screen

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_CHAN_MIN: Transmitter switch screen minimum pwm

This sets the PWM lower limit for this screen

Range

900 to 2100

OSD2_CHAN_MAX: Transmitter switch screen maximum pwm

This sets the PWM upper limit for this screen

Range

900 to 2100

OSD2_ALTITUDE_EN: ALTITUDE_EN

Enables display of altitude AGL

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ALTITUDE_X: ALTITUDE_X

Horizontal position on screen

Range

0 to 59

OSD2_ALTITUDE_Y: ALTITUDE_Y

Vertical position on screen

Range

0 to 21

OSD2_BAT_VOLT_EN: BATVOLT_EN

Displays main battery voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_BAT_VOLT_X: BATVOLT_X

Horizontal position on screen

Range

0 to 59

OSD2_BAT_VOLT_Y: BATVOLT_Y

Vertical position on screen

Range

0 to 21

OSD2_RSSI_EN: RSSI_EN

Displays RC signal strength

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_RSSI_X: RSSI_X

Horizontal position on screen

Range

0 to 59

OSD2_RSSI_Y: RSSI_Y

Vertical position on screen

Range

0 to 21

OSD2_CURRENT_EN: CURRENT_EN

Displays main battery current

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_CURRENT_X: CURRENT_X

Horizontal position on screen

Range

0 to 59

OSD2_CURRENT_Y: CURRENT_Y

Vertical position on screen

Range

0 to 21

OSD2_BATUSED_EN: BATUSED_EN

Displays primary battery mAh consumed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_BATUSED_X: BATUSED_X

Horizontal position on screen

Range

0 to 59

OSD2_BATUSED_Y: BATUSED_Y

Vertical position on screen

Range

0 to 21

OSD2_SATS_EN: SATS_EN

Displays number of acquired satellites

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_SATS_X: SATS_X

Horizontal position on screen

Range

0 to 59

OSD2_SATS_Y: SATS_Y

Vertical position on screen

Range

0 to 21

OSD2_FLTMODE_EN: FLTMODE_EN

Displays flight mode

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_FLTMODE_X: FLTMODE_X

Horizontal position on screen

Range

0 to 59

OSD2_FLTMODE_Y: FLTMODE_Y

Vertical position on screen

Range

0 to 21

OSD2_MESSAGE_EN: MESSAGE_EN

Displays Mavlink messages

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_MESSAGE_X: MESSAGE_X

Horizontal position on screen

Range

0 to 59

OSD2_MESSAGE_Y: MESSAGE_Y

Vertical position on screen

Range

0 to 21

OSD2_GSPEED_EN: GSPEED_EN

Displays GPS ground speed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_GSPEED_X: GSPEED_X

Horizontal position on screen

Range

0 to 59

OSD2_GSPEED_Y: GSPEED_Y

Vertical position on screen

Range

0 to 21

OSD2_HORIZON_EN: HORIZON_EN

Displays artificial horizon

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_HORIZON_X: HORIZON_X

Horizontal position on screen

Range

0 to 59

OSD2_HORIZON_Y: HORIZON_Y

Vertical position on screen

Range

0 to 21

OSD2_HOME_EN: HOME_EN

Displays distance and relative direction to HOME

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_HOME_X: HOME_X

Horizontal position on screen

Range

0 to 59

OSD2_HOME_Y: HOME_Y

Vertical position on screen

Range

0 to 21

OSD2_HEADING_EN: HEADING_EN

Displays heading

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_HEADING_X: HEADING_X

Horizontal position on screen

Range

0 to 59

OSD2_HEADING_Y: HEADING_Y

Vertical position on screen

Range

0 to 21

OSD2_THROTTLE_EN: THROTTLE_EN

Displays actual throttle percentage being sent to motor(s)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_THROTTLE_X: THROTTLE_X

Horizontal position on screen

Range

0 to 59

OSD2_THROTTLE_Y: THROTTLE_Y

Vertical position on screen

Range

0 to 21

OSD2_COMPASS_EN: COMPASS_EN

Enables display of compass rose

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_COMPASS_X: COMPASS_X

Horizontal position on screen

Range

0 to 59

OSD2_COMPASS_Y: COMPASS_Y

Vertical position on screen

Range

0 to 21

OSD2_WIND_EN: WIND_EN

Displays wind speed and relative direction, on Rover this is the apparent wind speed and direction from the windvane, if fitted

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_WIND_X: WIND_X

Horizontal position on screen

Range

0 to 59

OSD2_WIND_Y: WIND_Y

Vertical position on screen

Range

0 to 21

OSD2_ASPEED_EN: ASPEED_EN

Displays airspeed value being used by TECS (fused value)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ASPEED_X: ASPEED_X

Horizontal position on screen

Range

0 to 59

OSD2_ASPEED_Y: ASPEED_Y

Vertical position on screen

Range

0 to 21

OSD2_VSPEED_EN: VSPEED_EN

Displays climb rate

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_VSPEED_X: VSPEED_X

Horizontal position on screen

Range

0 to 59

OSD2_VSPEED_Y: VSPEED_Y

Vertical position on screen

Range

0 to 21

OSD2_ESCTEMP_EN: ESCTEMP_EN

Displays highest temp of all active ESCs, or of a specific ECS if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ESCTEMP_X: ESCTEMP_X

Horizontal position on screen

Range

0 to 59

OSD2_ESCTEMP_Y: ESCTEMP_Y

Vertical position on screen

Range

0 to 21

OSD2_ESCRPM_EN: ESCRPM_EN

Displays highest rpm of all active ESCs, or of a specific ESC if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ESCRPM_X: ESCRPM_X

Horizontal position on screen

Range

0 to 59

OSD2_ESCRPM_Y: ESCRPM_Y

Vertical position on screen

Range

0 to 21

OSD2_ESCAMPS_EN: ESCAMPS_EN

Displays the current of the ESC with the highest rpm of all active ESCs, or of a specific ESC if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ESCAMPS_X: ESCAMPS_X

Horizontal position on screen

Range

0 to 59

OSD2_ESCAMPS_Y: ESCAMPS_Y

Vertical position on screen

Range

0 to 21

OSD2_GPSLAT_EN: GPSLAT_EN

Displays GPS latitude

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_GPSLAT_X: GPSLAT_X

Horizontal position on screen

Range

0 to 59

OSD2_GPSLAT_Y: GPSLAT_Y

Vertical position on screen

Range

0 to 21

OSD2_GPSLONG_EN: GPSLONG_EN

Displays GPS longitude

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_GPSLONG_X: GPSLONG_X

Horizontal position on screen

Range

0 to 59

OSD2_GPSLONG_Y: GPSLONG_Y

Vertical position on screen

Range

0 to 21

OSD2_ROLL_EN: ROLL_EN

Displays degrees of roll from level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ROLL_X: ROLL_X

Horizontal position on screen

Range

0 to 59

OSD2_ROLL_Y: ROLL_Y

Vertical position on screen

Range

0 to 21

OSD2_PITCH_EN: PITCH_EN

Displays degrees of pitch from level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_PITCH_X: PITCH_X

Horizontal position on screen

Range

0 to 59

OSD2_PITCH_Y: PITCH_Y

Vertical position on screen

Range

0 to 21

OSD2_TEMP_EN: TEMP_EN

Displays temperature reported by primary barometer

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_TEMP_X: TEMP_X

Horizontal position on screen

Range

0 to 59

OSD2_TEMP_Y: TEMP_Y

Vertical position on screen

Range

0 to 21

OSD2_HDOP_EN: HDOP_EN

Displays Horizontal Dilution Of Position

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_HDOP_X: HDOP_X

Horizontal position on screen

Range

0 to 59

OSD2_HDOP_Y: HDOP_Y

Vertical position on screen

Range

0 to 21

OSD2_WAYPOINT_EN: WAYPOINT_EN

Displays bearing and distance to next waypoint

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_WAYPOINT_X: WAYPOINT_X

Horizontal position on screen

Range

0 to 59

OSD2_WAYPOINT_Y: WAYPOINT_Y

Vertical position on screen

Range

0 to 21

OSD2_XTRACK_EN: XTRACK_EN

Displays crosstrack error

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_XTRACK_X: XTRACK_X

Horizontal position on screen

Range

0 to 59

OSD2_XTRACK_Y: XTRACK_Y

Vertical position on screen

Range

0 to 21

OSD2_DIST_EN: DIST_EN

Displays total distance flown

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_DIST_X: DIST_X

Horizontal position on screen

Range

0 to 59

OSD2_DIST_Y: DIST_Y

Vertical position on screen

Range

0 to 21

OSD2_STATS_EN: STATS_EN

Displays flight stats

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_STATS_X: STATS_X

Horizontal position on screen

Range

0 to 59

OSD2_STATS_Y: STATS_Y

Vertical position on screen

Range

0 to 21

OSD2_FLTIME_EN: FLTIME_EN

Displays total flight time

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_FLTIME_X: FLTIME_X

Horizontal position on screen

Range

0 to 59

OSD2_FLTIME_Y: FLTIME_Y

Vertical position on screen

Range

0 to 21

OSD2_CLIMBEFF_EN: CLIMBEFF_EN

Displays climb efficiency (climb rate/current)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_CLIMBEFF_X: CLIMBEFF_X

Horizontal position on screen

Range

0 to 59

OSD2_CLIMBEFF_Y: CLIMBEFF_Y

Vertical position on screen

Range

0 to 21

OSD2_EFF_EN: EFF_EN

Displays flight efficiency (mAh/km or /mi)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_EFF_X: EFF_X

Horizontal position on screen

Range

0 to 59

OSD2_EFF_Y: EFF_Y

Vertical position on screen

Range

0 to 21

OSD2_BTEMP_EN: BTEMP_EN

Displays temperature reported by secondary barometer

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_BTEMP_X: BTEMP_X

Horizontal position on screen

Range

0 to 59

OSD2_BTEMP_Y: BTEMP_Y

Vertical position on screen

Range

0 to 21

OSD2_ATEMP_EN: ATEMP_EN

Displays temperature reported by primary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ATEMP_X: ATEMP_X

Horizontal position on screen

Range

0 to 59

OSD2_ATEMP_Y: ATEMP_Y

Vertical position on screen

Range

0 to 21

OSD2_BAT2_VLT_EN: BAT2VLT_EN

Displays battery2 voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_BAT2_VLT_X: BAT2VLT_X

Horizontal position on screen

Range

0 to 59

OSD2_BAT2_VLT_Y: BAT2VLT_Y

Vertical position on screen

Range

0 to 21

OSD2_BAT2USED_EN: BAT2USED_EN

Displays secondary battery mAh consumed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_BAT2USED_X: BAT2USED_X

Horizontal position on screen

Range

0 to 59

OSD2_BAT2USED_Y: BAT2USED_Y

Vertical position on screen

Range

0 to 21

OSD2_ASPD2_EN: ASPD2_EN

Displays airspeed reported directly from secondary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ASPD2_X: ASPD2_X

Horizontal position on screen

Range

0 to 59

OSD2_ASPD2_Y: ASPD2_Y

Vertical position on screen

Range

0 to 21

OSD2_ASPD1_EN: ASPD1_EN

Displays airspeed reported directly from primary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ASPD1_X: ASPD1_X

Horizontal position on screen

Range

0 to 59

OSD2_ASPD1_Y: ASPD1_Y

Vertical position on screen

Range

0 to 21

OSD2_CLK_EN: CLK_EN

Displays a clock panel based on AP_RTC local time

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_CLK_X: CLK_X

Horizontal position on screen

Range

0 to 59

OSD2_CLK_Y: CLK_Y

Vertical position on screen

Range

0 to 21

OSD2_SIDEBARS_EN: SIDEBARS_EN

Displays artificial horizon side bars

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_SIDEBARS_X: SIDEBARS_X

Horizontal position on screen

Range

0 to 59

OSD2_SIDEBARS_Y: SIDEBARS_Y

Vertical position on screen

Range

0 to 21

OSD2_CRSSHAIR_EN: CRSSHAIR_EN

Displays artificial horizon crosshair (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_CRSSHAIR_X: CRSSHAIR_X

Horizontal position on screen (MSP OSD only)

Range

0 to 59

OSD2_CRSSHAIR_Y: CRSSHAIR_Y

Vertical position on screen (MSP OSD only)

Range

0 to 21

OSD2_HOMEDIST_EN: HOMEDIST_EN

Displays distance from HOME (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_HOMEDIST_X: HOMEDIST_X

Horizontal position on screen (MSP OSD only)

Range

0 to 59

OSD2_HOMEDIST_Y: HOMEDIST_Y

Vertical position on screen (MSP OSD only)

Range

0 to 21

OSD2_HOMEDIR_EN: HOMEDIR_EN

Displays relative direction to HOME (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_HOMEDIR_X: HOMEDIR_X

Horizontal position on screen

Range

0 to 59

OSD2_HOMEDIR_Y: HOMEDIR_Y

Vertical position on screen

Range

0 to 21

OSD2_POWER_EN: POWER_EN

Displays power (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_POWER_X: POWER_X

Horizontal position on screen

Range

0 to 59

OSD2_POWER_Y: POWER_Y

Vertical position on screen

Range

0 to 21

OSD2_CELLVOLT_EN: CELL_VOLT_EN

Displays average cell voltage (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_CELLVOLT_X: CELL_VOLT_X

Horizontal position on screen

Range

0 to 59

OSD2_CELLVOLT_Y: CELL_VOLT_Y

Vertical position on screen

Range

0 to 21

OSD2_BATTBAR_EN: BATT_BAR_EN

Displays battery usage bar (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_BATTBAR_X: BATT_BAR_X

Horizontal position on screen

Range

0 to 59

OSD2_BATTBAR_Y: BATT_BAR_Y

Vertical position on screen

Range

0 to 21

OSD2_ARMING_EN: ARMING_EN

Displays arming status (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ARMING_X: ARMING_X

Horizontal position on screen

Range

0 to 59

OSD2_ARMING_Y: ARMING_Y

Vertical position on screen

Range

0 to 21

OSD2_PLUSCODE_EN: PLUSCODE_EN

Displays pluscode (OLC) element

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_PLUSCODE_X: PLUSCODE_X

Horizontal position on screen

Range

0 to 59

OSD2_PLUSCODE_Y: PLUSCODE_Y

Vertical position on screen

Range

0 to 21

OSD2_CALLSIGN_EN: CALLSIGN_EN

Displays callsign from callsign.txt on microSD card

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_CALLSIGN_X: CALLSIGN_X

Horizontal position on screen

Range

0 to 59

OSD2_CALLSIGN_Y: CALLSIGN_Y

Vertical position on screen

Range

0 to 21

OSD2_CURRENT2_EN: CURRENT2_EN

Displays 2nd battery current

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_CURRENT2_X: CURRENT2_X

Horizontal position on screen

Range

0 to 59

OSD2_CURRENT2_Y: CURRENT2_Y

Vertical position on screen

Range

0 to 21

OSD2_VTX_PWR_EN: VTX_PWR_EN

Displays VTX Power

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_VTX_PWR_X: VTX_PWR_X

Horizontal position on screen

Range

0 to 59

OSD2_VTX_PWR_Y: VTX_PWR_Y

Vertical position on screen

Range

0 to 21

OSD2_TER_HGT_EN: TER_HGT_EN

Displays Height above terrain

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_TER_HGT_X: TER_HGT_X

Horizontal position on screen

Range

0 to 59

OSD2_TER_HGT_Y: TER_HGT_Y

Vertical position on screen

Range

0 to 21

OSD2_AVGCELLV_EN: AVGCELLV_EN

Displays average cell voltage. WARNING: this can be inaccurate if the cell count is not detected or set properly. If the the battery is far from fully charged the detected cell count might not be accurate if auto cell count detection is used (OSD_CELL_COUNT=0).

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_AVGCELLV_X: AVGCELLV_X

Horizontal position on screen

Range

0 to 59

OSD2_AVGCELLV_Y: AVGCELLV_Y

Vertical position on screen

Range

0 to 21

OSD2_RESTVOLT_EN: RESTVOLT_EN

Displays main battery resting voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_RESTVOLT_X: RESTVOLT_X

Horizontal position on screen

Range

0 to 59

OSD2_RESTVOLT_Y: RESTVOLT_Y

Vertical position on screen

Range

0 to 21

OSD2_FENCE_EN: FENCE_EN

Displays indication of fence enable and breach

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_FENCE_X: FENCE_X

Horizontal position on screen

Range

0 to 59

OSD2_FENCE_Y: FENCE_Y

Vertical position on screen

Range

0 to 21

OSD2_RNGF_EN: RNGF_EN

Displays a rangefinder's distance in cm

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_RNGF_X: RNGF_X

Horizontal position on screen

Range

0 to 59

OSD2_RNGF_Y: RNGF_Y

Vertical position on screen

Range

0 to 21

OSD2_ACRVOLT_EN: ACRVOLT_EN

Displays resting voltage for the average cell. WARNING: this can be inaccurate if the cell count is not detected or set properly. If the the battery is far from fully charged the detected cell count might not be accurate if auto cell count detection is used (OSD_CELL_COUNT=0).

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_ACRVOLT_X: ACRVOLT_X

Horizontal position on screen

Range

0 to 59

OSD2_ACRVOLT_Y: ACRVOLT_Y

Vertical position on screen

Range

0 to 21

OSD2_RPM_EN: RPM_EN

Displays main rotor revs/min

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_RPM_X: RPM_X

Horizontal position on screen

Range

0 to 29

OSD2_RPM_Y: RPM_Y

Vertical position on screen

Range

0 to 15

OSD2_TXT_RES: Sets the overlay text resolution (MSP DisplayPort only)

Sets the overlay text resolution for this screen to either SD 30x16 or HD 50x18/60x22 (MSP DisplayPort only)

Values

Value

Meaning

0

30x16

1

50x18

2

60x22

OSD2_FONT: Sets the font index for this screen (MSP DisplayPort only)

Sets the font index for this screen (MSP DisplayPort only)

Range

0 to 21

OSD2_RC_PWR_EN: RC_PWR_EN

Displays the RC link transmit (TX) power in mW or W, depending on level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_RC_PWR_X: RC_PWR_X

Horizontal position on screen

Range

0 to 59

OSD2_RC_PWR_Y: RC_PWR_Y

Vertical position on screen

Range

0 to 21

OSD2_RSSIDBM_EN: RSSIDBM_EN

Displays RC link signal strength in dBm

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_RSSIDBM_X: RSSIDBM_X

Horizontal position on screen

Range

0 to 59

OSD2_RSSIDBM_Y: RSSIDBM_Y

Vertical position on screen

Range

0 to 21

OSD2_RC_SNR_EN: RC_SNR_EN

Displays RC link signal to noise ratio in dB

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_RC_SNR_X: RC_SNR_X

Horizontal position on screen

Range

0 to 59

OSD2_RC_SNR_Y: RC_SNR_Y

Vertical position on screen

Range

0 to 21

OSD2_RC_ANT_EN: RC_ANT_EN

Displays the current RC link active antenna

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_RC_ANT_X: RC_ANT_X

Horizontal position on screen

Range

0 to 59

OSD2_RC_ANT_Y: RC_ANT_Y

Vertical position on screen

Range

0 to 21

OSD2_RC_LQ_EN: RC_LQ_EN

Displays the RC link quality (uplink, 0 to 100%) and also RF mode if bit 7 of OSD_OPTIONS is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD2_RC_LQ_X: RC_LQ_X

Horizontal position on screen

Range

0 to 59

OSD2_RC_LQ_Y: RC_LQ_Y

Vertical position on screen

Range

0 to 21

OSD2_ESC_IDX: ESC_IDX

Index of the ESC to use for displaying ESC information. 0 means use the ESC with the highest value.

Range

0 to 32

OSD3_ Parameters

OSD3_ENABLE: Enable screen

Enable this screen

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_CHAN_MIN: Transmitter switch screen minimum pwm

This sets the PWM lower limit for this screen

Range

900 to 2100

OSD3_CHAN_MAX: Transmitter switch screen maximum pwm

This sets the PWM upper limit for this screen

Range

900 to 2100

OSD3_ALTITUDE_EN: ALTITUDE_EN

Enables display of altitude AGL

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ALTITUDE_X: ALTITUDE_X

Horizontal position on screen

Range

0 to 59

OSD3_ALTITUDE_Y: ALTITUDE_Y

Vertical position on screen

Range

0 to 21

OSD3_BAT_VOLT_EN: BATVOLT_EN

Displays main battery voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_BAT_VOLT_X: BATVOLT_X

Horizontal position on screen

Range

0 to 59

OSD3_BAT_VOLT_Y: BATVOLT_Y

Vertical position on screen

Range

0 to 21

OSD3_RSSI_EN: RSSI_EN

Displays RC signal strength

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_RSSI_X: RSSI_X

Horizontal position on screen

Range

0 to 59

OSD3_RSSI_Y: RSSI_Y

Vertical position on screen

Range

0 to 21

OSD3_CURRENT_EN: CURRENT_EN

Displays main battery current

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_CURRENT_X: CURRENT_X

Horizontal position on screen

Range

0 to 59

OSD3_CURRENT_Y: CURRENT_Y

Vertical position on screen

Range

0 to 21

OSD3_BATUSED_EN: BATUSED_EN

Displays primary battery mAh consumed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_BATUSED_X: BATUSED_X

Horizontal position on screen

Range

0 to 59

OSD3_BATUSED_Y: BATUSED_Y

Vertical position on screen

Range

0 to 21

OSD3_SATS_EN: SATS_EN

Displays number of acquired satellites

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_SATS_X: SATS_X

Horizontal position on screen

Range

0 to 59

OSD3_SATS_Y: SATS_Y

Vertical position on screen

Range

0 to 21

OSD3_FLTMODE_EN: FLTMODE_EN

Displays flight mode

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_FLTMODE_X: FLTMODE_X

Horizontal position on screen

Range

0 to 59

OSD3_FLTMODE_Y: FLTMODE_Y

Vertical position on screen

Range

0 to 21

OSD3_MESSAGE_EN: MESSAGE_EN

Displays Mavlink messages

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_MESSAGE_X: MESSAGE_X

Horizontal position on screen

Range

0 to 59

OSD3_MESSAGE_Y: MESSAGE_Y

Vertical position on screen

Range

0 to 21

OSD3_GSPEED_EN: GSPEED_EN

Displays GPS ground speed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_GSPEED_X: GSPEED_X

Horizontal position on screen

Range

0 to 59

OSD3_GSPEED_Y: GSPEED_Y

Vertical position on screen

Range

0 to 21

OSD3_HORIZON_EN: HORIZON_EN

Displays artificial horizon

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_HORIZON_X: HORIZON_X

Horizontal position on screen

Range

0 to 59

OSD3_HORIZON_Y: HORIZON_Y

Vertical position on screen

Range

0 to 21

OSD3_HOME_EN: HOME_EN

Displays distance and relative direction to HOME

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_HOME_X: HOME_X

Horizontal position on screen

Range

0 to 59

OSD3_HOME_Y: HOME_Y

Vertical position on screen

Range

0 to 21

OSD3_HEADING_EN: HEADING_EN

Displays heading

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_HEADING_X: HEADING_X

Horizontal position on screen

Range

0 to 59

OSD3_HEADING_Y: HEADING_Y

Vertical position on screen

Range

0 to 21

OSD3_THROTTLE_EN: THROTTLE_EN

Displays actual throttle percentage being sent to motor(s)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_THROTTLE_X: THROTTLE_X

Horizontal position on screen

Range

0 to 59

OSD3_THROTTLE_Y: THROTTLE_Y

Vertical position on screen

Range

0 to 21

OSD3_COMPASS_EN: COMPASS_EN

Enables display of compass rose

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_COMPASS_X: COMPASS_X

Horizontal position on screen

Range

0 to 59

OSD3_COMPASS_Y: COMPASS_Y

Vertical position on screen

Range

0 to 21

OSD3_WIND_EN: WIND_EN

Displays wind speed and relative direction, on Rover this is the apparent wind speed and direction from the windvane, if fitted

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_WIND_X: WIND_X

Horizontal position on screen

Range

0 to 59

OSD3_WIND_Y: WIND_Y

Vertical position on screen

Range

0 to 21

OSD3_ASPEED_EN: ASPEED_EN

Displays airspeed value being used by TECS (fused value)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ASPEED_X: ASPEED_X

Horizontal position on screen

Range

0 to 59

OSD3_ASPEED_Y: ASPEED_Y

Vertical position on screen

Range

0 to 21

OSD3_VSPEED_EN: VSPEED_EN

Displays climb rate

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_VSPEED_X: VSPEED_X

Horizontal position on screen

Range

0 to 59

OSD3_VSPEED_Y: VSPEED_Y

Vertical position on screen

Range

0 to 21

OSD3_ESCTEMP_EN: ESCTEMP_EN

Displays highest temp of all active ESCs, or of a specific ECS if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ESCTEMP_X: ESCTEMP_X

Horizontal position on screen

Range

0 to 59

OSD3_ESCTEMP_Y: ESCTEMP_Y

Vertical position on screen

Range

0 to 21

OSD3_ESCRPM_EN: ESCRPM_EN

Displays highest rpm of all active ESCs, or of a specific ESC if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ESCRPM_X: ESCRPM_X

Horizontal position on screen

Range

0 to 59

OSD3_ESCRPM_Y: ESCRPM_Y

Vertical position on screen

Range

0 to 21

OSD3_ESCAMPS_EN: ESCAMPS_EN

Displays the current of the ESC with the highest rpm of all active ESCs, or of a specific ESC if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ESCAMPS_X: ESCAMPS_X

Horizontal position on screen

Range

0 to 59

OSD3_ESCAMPS_Y: ESCAMPS_Y

Vertical position on screen

Range

0 to 21

OSD3_GPSLAT_EN: GPSLAT_EN

Displays GPS latitude

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_GPSLAT_X: GPSLAT_X

Horizontal position on screen

Range

0 to 59

OSD3_GPSLAT_Y: GPSLAT_Y

Vertical position on screen

Range

0 to 21

OSD3_GPSLONG_EN: GPSLONG_EN

Displays GPS longitude

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_GPSLONG_X: GPSLONG_X

Horizontal position on screen

Range

0 to 59

OSD3_GPSLONG_Y: GPSLONG_Y

Vertical position on screen

Range

0 to 21

OSD3_ROLL_EN: ROLL_EN

Displays degrees of roll from level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ROLL_X: ROLL_X

Horizontal position on screen

Range

0 to 59

OSD3_ROLL_Y: ROLL_Y

Vertical position on screen

Range

0 to 21

OSD3_PITCH_EN: PITCH_EN

Displays degrees of pitch from level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_PITCH_X: PITCH_X

Horizontal position on screen

Range

0 to 59

OSD3_PITCH_Y: PITCH_Y

Vertical position on screen

Range

0 to 21

OSD3_TEMP_EN: TEMP_EN

Displays temperature reported by primary barometer

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_TEMP_X: TEMP_X

Horizontal position on screen

Range

0 to 59

OSD3_TEMP_Y: TEMP_Y

Vertical position on screen

Range

0 to 21

OSD3_HDOP_EN: HDOP_EN

Displays Horizontal Dilution Of Position

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_HDOP_X: HDOP_X

Horizontal position on screen

Range

0 to 59

OSD3_HDOP_Y: HDOP_Y

Vertical position on screen

Range

0 to 21

OSD3_WAYPOINT_EN: WAYPOINT_EN

Displays bearing and distance to next waypoint

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_WAYPOINT_X: WAYPOINT_X

Horizontal position on screen

Range

0 to 59

OSD3_WAYPOINT_Y: WAYPOINT_Y

Vertical position on screen

Range

0 to 21

OSD3_XTRACK_EN: XTRACK_EN

Displays crosstrack error

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_XTRACK_X: XTRACK_X

Horizontal position on screen

Range

0 to 59

OSD3_XTRACK_Y: XTRACK_Y

Vertical position on screen

Range

0 to 21

OSD3_DIST_EN: DIST_EN

Displays total distance flown

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_DIST_X: DIST_X

Horizontal position on screen

Range

0 to 59

OSD3_DIST_Y: DIST_Y

Vertical position on screen

Range

0 to 21

OSD3_STATS_EN: STATS_EN

Displays flight stats

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_STATS_X: STATS_X

Horizontal position on screen

Range

0 to 59

OSD3_STATS_Y: STATS_Y

Vertical position on screen

Range

0 to 21

OSD3_FLTIME_EN: FLTIME_EN

Displays total flight time

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_FLTIME_X: FLTIME_X

Horizontal position on screen

Range

0 to 59

OSD3_FLTIME_Y: FLTIME_Y

Vertical position on screen

Range

0 to 21

OSD3_CLIMBEFF_EN: CLIMBEFF_EN

Displays climb efficiency (climb rate/current)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_CLIMBEFF_X: CLIMBEFF_X

Horizontal position on screen

Range

0 to 59

OSD3_CLIMBEFF_Y: CLIMBEFF_Y

Vertical position on screen

Range

0 to 21

OSD3_EFF_EN: EFF_EN

Displays flight efficiency (mAh/km or /mi)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_EFF_X: EFF_X

Horizontal position on screen

Range

0 to 59

OSD3_EFF_Y: EFF_Y

Vertical position on screen

Range

0 to 21

OSD3_BTEMP_EN: BTEMP_EN

Displays temperature reported by secondary barometer

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_BTEMP_X: BTEMP_X

Horizontal position on screen

Range

0 to 59

OSD3_BTEMP_Y: BTEMP_Y

Vertical position on screen

Range

0 to 21

OSD3_ATEMP_EN: ATEMP_EN

Displays temperature reported by primary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ATEMP_X: ATEMP_X

Horizontal position on screen

Range

0 to 59

OSD3_ATEMP_Y: ATEMP_Y

Vertical position on screen

Range

0 to 21

OSD3_BAT2_VLT_EN: BAT2VLT_EN

Displays battery2 voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_BAT2_VLT_X: BAT2VLT_X

Horizontal position on screen

Range

0 to 59

OSD3_BAT2_VLT_Y: BAT2VLT_Y

Vertical position on screen

Range

0 to 21

OSD3_BAT2USED_EN: BAT2USED_EN

Displays secondary battery mAh consumed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_BAT2USED_X: BAT2USED_X

Horizontal position on screen

Range

0 to 59

OSD3_BAT2USED_Y: BAT2USED_Y

Vertical position on screen

Range

0 to 21

OSD3_ASPD2_EN: ASPD2_EN

Displays airspeed reported directly from secondary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ASPD2_X: ASPD2_X

Horizontal position on screen

Range

0 to 59

OSD3_ASPD2_Y: ASPD2_Y

Vertical position on screen

Range

0 to 21

OSD3_ASPD1_EN: ASPD1_EN

Displays airspeed reported directly from primary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ASPD1_X: ASPD1_X

Horizontal position on screen

Range

0 to 59

OSD3_ASPD1_Y: ASPD1_Y

Vertical position on screen

Range

0 to 21

OSD3_CLK_EN: CLK_EN

Displays a clock panel based on AP_RTC local time

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_CLK_X: CLK_X

Horizontal position on screen

Range

0 to 59

OSD3_CLK_Y: CLK_Y

Vertical position on screen

Range

0 to 21

OSD3_SIDEBARS_EN: SIDEBARS_EN

Displays artificial horizon side bars

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_SIDEBARS_X: SIDEBARS_X

Horizontal position on screen

Range

0 to 59

OSD3_SIDEBARS_Y: SIDEBARS_Y

Vertical position on screen

Range

0 to 21

OSD3_CRSSHAIR_EN: CRSSHAIR_EN

Displays artificial horizon crosshair (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_CRSSHAIR_X: CRSSHAIR_X

Horizontal position on screen (MSP OSD only)

Range

0 to 59

OSD3_CRSSHAIR_Y: CRSSHAIR_Y

Vertical position on screen (MSP OSD only)

Range

0 to 21

OSD3_HOMEDIST_EN: HOMEDIST_EN

Displays distance from HOME (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_HOMEDIST_X: HOMEDIST_X

Horizontal position on screen (MSP OSD only)

Range

0 to 59

OSD3_HOMEDIST_Y: HOMEDIST_Y

Vertical position on screen (MSP OSD only)

Range

0 to 21

OSD3_HOMEDIR_EN: HOMEDIR_EN

Displays relative direction to HOME (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_HOMEDIR_X: HOMEDIR_X

Horizontal position on screen

Range

0 to 59

OSD3_HOMEDIR_Y: HOMEDIR_Y

Vertical position on screen

Range

0 to 21

OSD3_POWER_EN: POWER_EN

Displays power (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_POWER_X: POWER_X

Horizontal position on screen

Range

0 to 59

OSD3_POWER_Y: POWER_Y

Vertical position on screen

Range

0 to 21

OSD3_CELLVOLT_EN: CELL_VOLT_EN

Displays average cell voltage (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_CELLVOLT_X: CELL_VOLT_X

Horizontal position on screen

Range

0 to 59

OSD3_CELLVOLT_Y: CELL_VOLT_Y

Vertical position on screen

Range

0 to 21

OSD3_BATTBAR_EN: BATT_BAR_EN

Displays battery usage bar (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_BATTBAR_X: BATT_BAR_X

Horizontal position on screen

Range

0 to 59

OSD3_BATTBAR_Y: BATT_BAR_Y

Vertical position on screen

Range

0 to 21

OSD3_ARMING_EN: ARMING_EN

Displays arming status (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ARMING_X: ARMING_X

Horizontal position on screen

Range

0 to 59

OSD3_ARMING_Y: ARMING_Y

Vertical position on screen

Range

0 to 21

OSD3_PLUSCODE_EN: PLUSCODE_EN

Displays pluscode (OLC) element

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_PLUSCODE_X: PLUSCODE_X

Horizontal position on screen

Range

0 to 59

OSD3_PLUSCODE_Y: PLUSCODE_Y

Vertical position on screen

Range

0 to 21

OSD3_CALLSIGN_EN: CALLSIGN_EN

Displays callsign from callsign.txt on microSD card

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_CALLSIGN_X: CALLSIGN_X

Horizontal position on screen

Range

0 to 59

OSD3_CALLSIGN_Y: CALLSIGN_Y

Vertical position on screen

Range

0 to 21

OSD3_CURRENT2_EN: CURRENT2_EN

Displays 2nd battery current

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_CURRENT2_X: CURRENT2_X

Horizontal position on screen

Range

0 to 59

OSD3_CURRENT2_Y: CURRENT2_Y

Vertical position on screen

Range

0 to 21

OSD3_VTX_PWR_EN: VTX_PWR_EN

Displays VTX Power

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_VTX_PWR_X: VTX_PWR_X

Horizontal position on screen

Range

0 to 59

OSD3_VTX_PWR_Y: VTX_PWR_Y

Vertical position on screen

Range

0 to 21

OSD3_TER_HGT_EN: TER_HGT_EN

Displays Height above terrain

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_TER_HGT_X: TER_HGT_X

Horizontal position on screen

Range

0 to 59

OSD3_TER_HGT_Y: TER_HGT_Y

Vertical position on screen

Range

0 to 21

OSD3_AVGCELLV_EN: AVGCELLV_EN

Displays average cell voltage. WARNING: this can be inaccurate if the cell count is not detected or set properly. If the the battery is far from fully charged the detected cell count might not be accurate if auto cell count detection is used (OSD_CELL_COUNT=0).

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_AVGCELLV_X: AVGCELLV_X

Horizontal position on screen

Range

0 to 59

OSD3_AVGCELLV_Y: AVGCELLV_Y

Vertical position on screen

Range

0 to 21

OSD3_RESTVOLT_EN: RESTVOLT_EN

Displays main battery resting voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_RESTVOLT_X: RESTVOLT_X

Horizontal position on screen

Range

0 to 59

OSD3_RESTVOLT_Y: RESTVOLT_Y

Vertical position on screen

Range

0 to 21

OSD3_FENCE_EN: FENCE_EN

Displays indication of fence enable and breach

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_FENCE_X: FENCE_X

Horizontal position on screen

Range

0 to 59

OSD3_FENCE_Y: FENCE_Y

Vertical position on screen

Range

0 to 21

OSD3_RNGF_EN: RNGF_EN

Displays a rangefinder's distance in cm

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_RNGF_X: RNGF_X

Horizontal position on screen

Range

0 to 59

OSD3_RNGF_Y: RNGF_Y

Vertical position on screen

Range

0 to 21

OSD3_ACRVOLT_EN: ACRVOLT_EN

Displays resting voltage for the average cell. WARNING: this can be inaccurate if the cell count is not detected or set properly. If the the battery is far from fully charged the detected cell count might not be accurate if auto cell count detection is used (OSD_CELL_COUNT=0).

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_ACRVOLT_X: ACRVOLT_X

Horizontal position on screen

Range

0 to 59

OSD3_ACRVOLT_Y: ACRVOLT_Y

Vertical position on screen

Range

0 to 21

OSD3_RPM_EN: RPM_EN

Displays main rotor revs/min

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_RPM_X: RPM_X

Horizontal position on screen

Range

0 to 29

OSD3_RPM_Y: RPM_Y

Vertical position on screen

Range

0 to 15

OSD3_TXT_RES: Sets the overlay text resolution (MSP DisplayPort only)

Sets the overlay text resolution for this screen to either SD 30x16 or HD 50x18/60x22 (MSP DisplayPort only)

Values

Value

Meaning

0

30x16

1

50x18

2

60x22

OSD3_FONT: Sets the font index for this screen (MSP DisplayPort only)

Sets the font index for this screen (MSP DisplayPort only)

Range

0 to 21

OSD3_RC_PWR_EN: RC_PWR_EN

Displays the RC link transmit (TX) power in mW or W, depending on level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_RC_PWR_X: RC_PWR_X

Horizontal position on screen

Range

0 to 59

OSD3_RC_PWR_Y: RC_PWR_Y

Vertical position on screen

Range

0 to 21

OSD3_RSSIDBM_EN: RSSIDBM_EN

Displays RC link signal strength in dBm

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_RSSIDBM_X: RSSIDBM_X

Horizontal position on screen

Range

0 to 59

OSD3_RSSIDBM_Y: RSSIDBM_Y

Vertical position on screen

Range

0 to 21

OSD3_RC_SNR_EN: RC_SNR_EN

Displays RC link signal to noise ratio in dB

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_RC_SNR_X: RC_SNR_X

Horizontal position on screen

Range

0 to 59

OSD3_RC_SNR_Y: RC_SNR_Y

Vertical position on screen

Range

0 to 21

OSD3_RC_ANT_EN: RC_ANT_EN

Displays the current RC link active antenna

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_RC_ANT_X: RC_ANT_X

Horizontal position on screen

Range

0 to 59

OSD3_RC_ANT_Y: RC_ANT_Y

Vertical position on screen

Range

0 to 21

OSD3_RC_LQ_EN: RC_LQ_EN

Displays the RC link quality (uplink, 0 to 100%) and also RF mode if bit 7 of OSD_OPTIONS is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD3_RC_LQ_X: RC_LQ_X

Horizontal position on screen

Range

0 to 59

OSD3_RC_LQ_Y: RC_LQ_Y

Vertical position on screen

Range

0 to 21

OSD3_ESC_IDX: ESC_IDX

Index of the ESC to use for displaying ESC information. 0 means use the ESC with the highest value.

Range

0 to 32

OSD4_ Parameters

OSD4_ENABLE: Enable screen

Enable this screen

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_CHAN_MIN: Transmitter switch screen minimum pwm

This sets the PWM lower limit for this screen

Range

900 to 2100

OSD4_CHAN_MAX: Transmitter switch screen maximum pwm

This sets the PWM upper limit for this screen

Range

900 to 2100

OSD4_ALTITUDE_EN: ALTITUDE_EN

Enables display of altitude AGL

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ALTITUDE_X: ALTITUDE_X

Horizontal position on screen

Range

0 to 59

OSD4_ALTITUDE_Y: ALTITUDE_Y

Vertical position on screen

Range

0 to 21

OSD4_BAT_VOLT_EN: BATVOLT_EN

Displays main battery voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_BAT_VOLT_X: BATVOLT_X

Horizontal position on screen

Range

0 to 59

OSD4_BAT_VOLT_Y: BATVOLT_Y

Vertical position on screen

Range

0 to 21

OSD4_RSSI_EN: RSSI_EN

Displays RC signal strength

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_RSSI_X: RSSI_X

Horizontal position on screen

Range

0 to 59

OSD4_RSSI_Y: RSSI_Y

Vertical position on screen

Range

0 to 21

OSD4_CURRENT_EN: CURRENT_EN

Displays main battery current

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_CURRENT_X: CURRENT_X

Horizontal position on screen

Range

0 to 59

OSD4_CURRENT_Y: CURRENT_Y

Vertical position on screen

Range

0 to 21

OSD4_BATUSED_EN: BATUSED_EN

Displays primary battery mAh consumed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_BATUSED_X: BATUSED_X

Horizontal position on screen

Range

0 to 59

OSD4_BATUSED_Y: BATUSED_Y

Vertical position on screen

Range

0 to 21

OSD4_SATS_EN: SATS_EN

Displays number of acquired satellites

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_SATS_X: SATS_X

Horizontal position on screen

Range

0 to 59

OSD4_SATS_Y: SATS_Y

Vertical position on screen

Range

0 to 21

OSD4_FLTMODE_EN: FLTMODE_EN

Displays flight mode

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_FLTMODE_X: FLTMODE_X

Horizontal position on screen

Range

0 to 59

OSD4_FLTMODE_Y: FLTMODE_Y

Vertical position on screen

Range

0 to 21

OSD4_MESSAGE_EN: MESSAGE_EN

Displays Mavlink messages

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_MESSAGE_X: MESSAGE_X

Horizontal position on screen

Range

0 to 59

OSD4_MESSAGE_Y: MESSAGE_Y

Vertical position on screen

Range

0 to 21

OSD4_GSPEED_EN: GSPEED_EN

Displays GPS ground speed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_GSPEED_X: GSPEED_X

Horizontal position on screen

Range

0 to 59

OSD4_GSPEED_Y: GSPEED_Y

Vertical position on screen

Range

0 to 21

OSD4_HORIZON_EN: HORIZON_EN

Displays artificial horizon

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_HORIZON_X: HORIZON_X

Horizontal position on screen

Range

0 to 59

OSD4_HORIZON_Y: HORIZON_Y

Vertical position on screen

Range

0 to 21

OSD4_HOME_EN: HOME_EN

Displays distance and relative direction to HOME

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_HOME_X: HOME_X

Horizontal position on screen

Range

0 to 59

OSD4_HOME_Y: HOME_Y

Vertical position on screen

Range

0 to 21

OSD4_HEADING_EN: HEADING_EN

Displays heading

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_HEADING_X: HEADING_X

Horizontal position on screen

Range

0 to 59

OSD4_HEADING_Y: HEADING_Y

Vertical position on screen

Range

0 to 21

OSD4_THROTTLE_EN: THROTTLE_EN

Displays actual throttle percentage being sent to motor(s)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_THROTTLE_X: THROTTLE_X

Horizontal position on screen

Range

0 to 59

OSD4_THROTTLE_Y: THROTTLE_Y

Vertical position on screen

Range

0 to 21

OSD4_COMPASS_EN: COMPASS_EN

Enables display of compass rose

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_COMPASS_X: COMPASS_X

Horizontal position on screen

Range

0 to 59

OSD4_COMPASS_Y: COMPASS_Y

Vertical position on screen

Range

0 to 21

OSD4_WIND_EN: WIND_EN

Displays wind speed and relative direction, on Rover this is the apparent wind speed and direction from the windvane, if fitted

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_WIND_X: WIND_X

Horizontal position on screen

Range

0 to 59

OSD4_WIND_Y: WIND_Y

Vertical position on screen

Range

0 to 21

OSD4_ASPEED_EN: ASPEED_EN

Displays airspeed value being used by TECS (fused value)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ASPEED_X: ASPEED_X

Horizontal position on screen

Range

0 to 59

OSD4_ASPEED_Y: ASPEED_Y

Vertical position on screen

Range

0 to 21

OSD4_VSPEED_EN: VSPEED_EN

Displays climb rate

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_VSPEED_X: VSPEED_X

Horizontal position on screen

Range

0 to 59

OSD4_VSPEED_Y: VSPEED_Y

Vertical position on screen

Range

0 to 21

OSD4_ESCTEMP_EN: ESCTEMP_EN

Displays highest temp of all active ESCs, or of a specific ECS if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ESCTEMP_X: ESCTEMP_X

Horizontal position on screen

Range

0 to 59

OSD4_ESCTEMP_Y: ESCTEMP_Y

Vertical position on screen

Range

0 to 21

OSD4_ESCRPM_EN: ESCRPM_EN

Displays highest rpm of all active ESCs, or of a specific ESC if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ESCRPM_X: ESCRPM_X

Horizontal position on screen

Range

0 to 59

OSD4_ESCRPM_Y: ESCRPM_Y

Vertical position on screen

Range

0 to 21

OSD4_ESCAMPS_EN: ESCAMPS_EN

Displays the current of the ESC with the highest rpm of all active ESCs, or of a specific ESC if OSDx_ESC_IDX is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ESCAMPS_X: ESCAMPS_X

Horizontal position on screen

Range

0 to 59

OSD4_ESCAMPS_Y: ESCAMPS_Y

Vertical position on screen

Range

0 to 21

OSD4_GPSLAT_EN: GPSLAT_EN

Displays GPS latitude

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_GPSLAT_X: GPSLAT_X

Horizontal position on screen

Range

0 to 59

OSD4_GPSLAT_Y: GPSLAT_Y

Vertical position on screen

Range

0 to 21

OSD4_GPSLONG_EN: GPSLONG_EN

Displays GPS longitude

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_GPSLONG_X: GPSLONG_X

Horizontal position on screen

Range

0 to 59

OSD4_GPSLONG_Y: GPSLONG_Y

Vertical position on screen

Range

0 to 21

OSD4_ROLL_EN: ROLL_EN

Displays degrees of roll from level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ROLL_X: ROLL_X

Horizontal position on screen

Range

0 to 59

OSD4_ROLL_Y: ROLL_Y

Vertical position on screen

Range

0 to 21

OSD4_PITCH_EN: PITCH_EN

Displays degrees of pitch from level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_PITCH_X: PITCH_X

Horizontal position on screen

Range

0 to 59

OSD4_PITCH_Y: PITCH_Y

Vertical position on screen

Range

0 to 21

OSD4_TEMP_EN: TEMP_EN

Displays temperature reported by primary barometer

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_TEMP_X: TEMP_X

Horizontal position on screen

Range

0 to 59

OSD4_TEMP_Y: TEMP_Y

Vertical position on screen

Range

0 to 21

OSD4_HDOP_EN: HDOP_EN

Displays Horizontal Dilution Of Position

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_HDOP_X: HDOP_X

Horizontal position on screen

Range

0 to 59

OSD4_HDOP_Y: HDOP_Y

Vertical position on screen

Range

0 to 21

OSD4_WAYPOINT_EN: WAYPOINT_EN

Displays bearing and distance to next waypoint

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_WAYPOINT_X: WAYPOINT_X

Horizontal position on screen

Range

0 to 59

OSD4_WAYPOINT_Y: WAYPOINT_Y

Vertical position on screen

Range

0 to 21

OSD4_XTRACK_EN: XTRACK_EN

Displays crosstrack error

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_XTRACK_X: XTRACK_X

Horizontal position on screen

Range

0 to 59

OSD4_XTRACK_Y: XTRACK_Y

Vertical position on screen

Range

0 to 21

OSD4_DIST_EN: DIST_EN

Displays total distance flown

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_DIST_X: DIST_X

Horizontal position on screen

Range

0 to 59

OSD4_DIST_Y: DIST_Y

Vertical position on screen

Range

0 to 21

OSD4_STATS_EN: STATS_EN

Displays flight stats

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_STATS_X: STATS_X

Horizontal position on screen

Range

0 to 59

OSD4_STATS_Y: STATS_Y

Vertical position on screen

Range

0 to 21

OSD4_FLTIME_EN: FLTIME_EN

Displays total flight time

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_FLTIME_X: FLTIME_X

Horizontal position on screen

Range

0 to 59

OSD4_FLTIME_Y: FLTIME_Y

Vertical position on screen

Range

0 to 21

OSD4_CLIMBEFF_EN: CLIMBEFF_EN

Displays climb efficiency (climb rate/current)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_CLIMBEFF_X: CLIMBEFF_X

Horizontal position on screen

Range

0 to 59

OSD4_CLIMBEFF_Y: CLIMBEFF_Y

Vertical position on screen

Range

0 to 21

OSD4_EFF_EN: EFF_EN

Displays flight efficiency (mAh/km or /mi)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_EFF_X: EFF_X

Horizontal position on screen

Range

0 to 59

OSD4_EFF_Y: EFF_Y

Vertical position on screen

Range

0 to 21

OSD4_BTEMP_EN: BTEMP_EN

Displays temperature reported by secondary barometer

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_BTEMP_X: BTEMP_X

Horizontal position on screen

Range

0 to 59

OSD4_BTEMP_Y: BTEMP_Y

Vertical position on screen

Range

0 to 21

OSD4_ATEMP_EN: ATEMP_EN

Displays temperature reported by primary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ATEMP_X: ATEMP_X

Horizontal position on screen

Range

0 to 59

OSD4_ATEMP_Y: ATEMP_Y

Vertical position on screen

Range

0 to 21

OSD4_BAT2_VLT_EN: BAT2VLT_EN

Displays battery2 voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_BAT2_VLT_X: BAT2VLT_X

Horizontal position on screen

Range

0 to 59

OSD4_BAT2_VLT_Y: BAT2VLT_Y

Vertical position on screen

Range

0 to 21

OSD4_BAT2USED_EN: BAT2USED_EN

Displays secondary battery mAh consumed

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_BAT2USED_X: BAT2USED_X

Horizontal position on screen

Range

0 to 59

OSD4_BAT2USED_Y: BAT2USED_Y

Vertical position on screen

Range

0 to 21

OSD4_ASPD2_EN: ASPD2_EN

Displays airspeed reported directly from secondary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ASPD2_X: ASPD2_X

Horizontal position on screen

Range

0 to 59

OSD4_ASPD2_Y: ASPD2_Y

Vertical position on screen

Range

0 to 21

OSD4_ASPD1_EN: ASPD1_EN

Displays airspeed reported directly from primary airspeed sensor

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ASPD1_X: ASPD1_X

Horizontal position on screen

Range

0 to 59

OSD4_ASPD1_Y: ASPD1_Y

Vertical position on screen

Range

0 to 21

OSD4_CLK_EN: CLK_EN

Displays a clock panel based on AP_RTC local time

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_CLK_X: CLK_X

Horizontal position on screen

Range

0 to 59

OSD4_CLK_Y: CLK_Y

Vertical position on screen

Range

0 to 21

OSD4_SIDEBARS_EN: SIDEBARS_EN

Displays artificial horizon side bars

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_SIDEBARS_X: SIDEBARS_X

Horizontal position on screen

Range

0 to 59

OSD4_SIDEBARS_Y: SIDEBARS_Y

Vertical position on screen

Range

0 to 21

OSD4_CRSSHAIR_EN: CRSSHAIR_EN

Displays artificial horizon crosshair (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_CRSSHAIR_X: CRSSHAIR_X

Horizontal position on screen (MSP OSD only)

Range

0 to 59

OSD4_CRSSHAIR_Y: CRSSHAIR_Y

Vertical position on screen (MSP OSD only)

Range

0 to 21

OSD4_HOMEDIST_EN: HOMEDIST_EN

Displays distance from HOME (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_HOMEDIST_X: HOMEDIST_X

Horizontal position on screen (MSP OSD only)

Range

0 to 59

OSD4_HOMEDIST_Y: HOMEDIST_Y

Vertical position on screen (MSP OSD only)

Range

0 to 21

OSD4_HOMEDIR_EN: HOMEDIR_EN

Displays relative direction to HOME (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_HOMEDIR_X: HOMEDIR_X

Horizontal position on screen

Range

0 to 59

OSD4_HOMEDIR_Y: HOMEDIR_Y

Vertical position on screen

Range

0 to 21

OSD4_POWER_EN: POWER_EN

Displays power (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_POWER_X: POWER_X

Horizontal position on screen

Range

0 to 59

OSD4_POWER_Y: POWER_Y

Vertical position on screen

Range

0 to 21

OSD4_CELLVOLT_EN: CELL_VOLT_EN

Displays average cell voltage (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_CELLVOLT_X: CELL_VOLT_X

Horizontal position on screen

Range

0 to 59

OSD4_CELLVOLT_Y: CELL_VOLT_Y

Vertical position on screen

Range

0 to 21

OSD4_BATTBAR_EN: BATT_BAR_EN

Displays battery usage bar (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_BATTBAR_X: BATT_BAR_X

Horizontal position on screen

Range

0 to 59

OSD4_BATTBAR_Y: BATT_BAR_Y

Vertical position on screen

Range

0 to 21

OSD4_ARMING_EN: ARMING_EN

Displays arming status (MSP OSD only)

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ARMING_X: ARMING_X

Horizontal position on screen

Range

0 to 59

OSD4_ARMING_Y: ARMING_Y

Vertical position on screen

Range

0 to 21

OSD4_PLUSCODE_EN: PLUSCODE_EN

Displays pluscode (OLC) element

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_PLUSCODE_X: PLUSCODE_X

Horizontal position on screen

Range

0 to 59

OSD4_PLUSCODE_Y: PLUSCODE_Y

Vertical position on screen

Range

0 to 21

OSD4_CALLSIGN_EN: CALLSIGN_EN

Displays callsign from callsign.txt on microSD card

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_CALLSIGN_X: CALLSIGN_X

Horizontal position on screen

Range

0 to 59

OSD4_CALLSIGN_Y: CALLSIGN_Y

Vertical position on screen

Range

0 to 21

OSD4_CURRENT2_EN: CURRENT2_EN

Displays 2nd battery current

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_CURRENT2_X: CURRENT2_X

Horizontal position on screen

Range

0 to 59

OSD4_CURRENT2_Y: CURRENT2_Y

Vertical position on screen

Range

0 to 21

OSD4_VTX_PWR_EN: VTX_PWR_EN

Displays VTX Power

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_VTX_PWR_X: VTX_PWR_X

Horizontal position on screen

Range

0 to 59

OSD4_VTX_PWR_Y: VTX_PWR_Y

Vertical position on screen

Range

0 to 21

OSD4_TER_HGT_EN: TER_HGT_EN

Displays Height above terrain

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_TER_HGT_X: TER_HGT_X

Horizontal position on screen

Range

0 to 59

OSD4_TER_HGT_Y: TER_HGT_Y

Vertical position on screen

Range

0 to 21

OSD4_AVGCELLV_EN: AVGCELLV_EN

Displays average cell voltage. WARNING: this can be inaccurate if the cell count is not detected or set properly. If the the battery is far from fully charged the detected cell count might not be accurate if auto cell count detection is used (OSD_CELL_COUNT=0).

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_AVGCELLV_X: AVGCELLV_X

Horizontal position on screen

Range

0 to 59

OSD4_AVGCELLV_Y: AVGCELLV_Y

Vertical position on screen

Range

0 to 21

OSD4_RESTVOLT_EN: RESTVOLT_EN

Displays main battery resting voltage

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_RESTVOLT_X: RESTVOLT_X

Horizontal position on screen

Range

0 to 59

OSD4_RESTVOLT_Y: RESTVOLT_Y

Vertical position on screen

Range

0 to 21

OSD4_FENCE_EN: FENCE_EN

Displays indication of fence enable and breach

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_FENCE_X: FENCE_X

Horizontal position on screen

Range

0 to 59

OSD4_FENCE_Y: FENCE_Y

Vertical position on screen

Range

0 to 21

OSD4_RNGF_EN: RNGF_EN

Displays a rangefinder's distance in cm

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_RNGF_X: RNGF_X

Horizontal position on screen

Range

0 to 59

OSD4_RNGF_Y: RNGF_Y

Vertical position on screen

Range

0 to 21

OSD4_ACRVOLT_EN: ACRVOLT_EN

Displays resting voltage for the average cell. WARNING: this can be inaccurate if the cell count is not detected or set properly. If the the battery is far from fully charged the detected cell count might not be accurate if auto cell count detection is used (OSD_CELL_COUNT=0).

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_ACRVOLT_X: ACRVOLT_X

Horizontal position on screen

Range

0 to 59

OSD4_ACRVOLT_Y: ACRVOLT_Y

Vertical position on screen

Range

0 to 21

OSD4_RPM_EN: RPM_EN

Displays main rotor revs/min

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_RPM_X: RPM_X

Horizontal position on screen

Range

0 to 29

OSD4_RPM_Y: RPM_Y

Vertical position on screen

Range

0 to 15

OSD4_TXT_RES: Sets the overlay text resolution (MSP DisplayPort only)

Sets the overlay text resolution for this screen to either SD 30x16 or HD 50x18/60x22 (MSP DisplayPort only)

Values

Value

Meaning

0

30x16

1

50x18

2

60x22

OSD4_FONT: Sets the font index for this screen (MSP DisplayPort only)

Sets the font index for this screen (MSP DisplayPort only)

Range

0 to 21

OSD4_RC_PWR_EN: RC_PWR_EN

Displays the RC link transmit (TX) power in mW or W, depending on level

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_RC_PWR_X: RC_PWR_X

Horizontal position on screen

Range

0 to 59

OSD4_RC_PWR_Y: RC_PWR_Y

Vertical position on screen

Range

0 to 21

OSD4_RSSIDBM_EN: RSSIDBM_EN

Displays RC link signal strength in dBm

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_RSSIDBM_X: RSSIDBM_X

Horizontal position on screen

Range

0 to 59

OSD4_RSSIDBM_Y: RSSIDBM_Y

Vertical position on screen

Range

0 to 21

OSD4_RC_SNR_EN: RC_SNR_EN

Displays RC link signal to noise ratio in dB

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_RC_SNR_X: RC_SNR_X

Horizontal position on screen

Range

0 to 59

OSD4_RC_SNR_Y: RC_SNR_Y

Vertical position on screen

Range

0 to 21

OSD4_RC_ANT_EN: RC_ANT_EN

Displays the current RC link active antenna

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_RC_ANT_X: RC_ANT_X

Horizontal position on screen

Range

0 to 59

OSD4_RC_ANT_Y: RC_ANT_Y

Vertical position on screen

Range

0 to 21

OSD4_RC_LQ_EN: RC_LQ_EN

Displays the RC link quality (uplink, 0 to 100%) and also RF mode if bit 7 of OSD_OPTIONS is set

Values

Value

Meaning

0

Disabled

1

Enabled

OSD4_RC_LQ_X: RC_LQ_X

Horizontal position on screen

Range

0 to 59

OSD4_RC_LQ_Y: RC_LQ_Y

Vertical position on screen

Range

0 to 21

OSD4_ESC_IDX: ESC_IDX

Index of the ESC to use for displaying ESC information. 0 means use the ESC with the highest value.

Range

0 to 32

OSD5_ Parameters

OSD5_ENABLE: Enable screen

Enable this screen

Values

Value

Meaning

0

Disabled

1

Enabled

OSD5_CHAN_MIN: Transmitter switch screen minimum pwm

This sets the PWM lower limit for this screen

Range

900 to 2100

OSD5_CHAN_MAX: Transmitter switch screen maximum pwm

This sets the PWM upper limit for this screen

Range

900 to 2100

OSD5_SAVE_X: SAVE_X

Note: This parameter is for advanced users

Horizontal position of Save button on screen

Range

0 to 25

OSD5_SAVE_Y: SAVE_Y

Note: This parameter is for advanced users

Vertical position of Save button on screen

Range

0 to 15

OSD5_PARAM1 Parameters

OSD5_PARAM1_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD5_PARAM1_X: X position

Horizontal position on screen

Range

0 to 29

OSD5_PARAM1_Y: Y position

Vertical position on screen

Range

0 to 15

OSD5_PARAM1_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD5_PARAM1_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD5_PARAM1_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD5_PARAM1_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD5_PARAM1_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD5_PARAM1_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD5_PARAM1_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD5_PARAM2 Parameters

OSD5_PARAM2_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD5_PARAM2_X: X position

Horizontal position on screen

Range

0 to 29

OSD5_PARAM2_Y: Y position

Vertical position on screen

Range

0 to 15

OSD5_PARAM2_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD5_PARAM2_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD5_PARAM2_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD5_PARAM2_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD5_PARAM2_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD5_PARAM2_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD5_PARAM2_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD5_PARAM3 Parameters

OSD5_PARAM3_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD5_PARAM3_X: X position

Horizontal position on screen

Range

0 to 29

OSD5_PARAM3_Y: Y position

Vertical position on screen

Range

0 to 15

OSD5_PARAM3_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD5_PARAM3_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD5_PARAM3_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD5_PARAM3_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD5_PARAM3_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD5_PARAM3_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD5_PARAM3_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD5_PARAM4 Parameters

OSD5_PARAM4_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD5_PARAM4_X: X position

Horizontal position on screen

Range

0 to 29

OSD5_PARAM4_Y: Y position

Vertical position on screen

Range

0 to 15

OSD5_PARAM4_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD5_PARAM4_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD5_PARAM4_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD5_PARAM4_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD5_PARAM4_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD5_PARAM4_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD5_PARAM4_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD5_PARAM5 Parameters

OSD5_PARAM5_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD5_PARAM5_X: X position

Horizontal position on screen

Range

0 to 29

OSD5_PARAM5_Y: Y position

Vertical position on screen

Range

0 to 15

OSD5_PARAM5_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD5_PARAM5_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD5_PARAM5_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD5_PARAM5_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD5_PARAM5_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD5_PARAM5_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD5_PARAM5_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD5_PARAM6 Parameters

OSD5_PARAM6_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD5_PARAM6_X: X position

Horizontal position on screen

Range

0 to 29

OSD5_PARAM6_Y: Y position

Vertical position on screen

Range

0 to 15

OSD5_PARAM6_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD5_PARAM6_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD5_PARAM6_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD5_PARAM6_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD5_PARAM6_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD5_PARAM6_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD5_PARAM6_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD5_PARAM7 Parameters

OSD5_PARAM7_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD5_PARAM7_X: X position

Horizontal position on screen

Range

0 to 29

OSD5_PARAM7_Y: Y position

Vertical position on screen

Range

0 to 15

OSD5_PARAM7_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD5_PARAM7_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD5_PARAM7_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD5_PARAM7_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD5_PARAM7_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD5_PARAM7_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD5_PARAM7_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD5_PARAM8 Parameters

OSD5_PARAM8_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD5_PARAM8_X: X position

Horizontal position on screen

Range

0 to 29

OSD5_PARAM8_Y: Y position

Vertical position on screen

Range

0 to 15

OSD5_PARAM8_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD5_PARAM8_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD5_PARAM8_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD5_PARAM8_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD5_PARAM8_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD5_PARAM8_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD5_PARAM8_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD5_PARAM9 Parameters

OSD5_PARAM9_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD5_PARAM9_X: X position

Horizontal position on screen

Range

0 to 29

OSD5_PARAM9_Y: Y position

Vertical position on screen

Range

0 to 15

OSD5_PARAM9_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD5_PARAM9_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD5_PARAM9_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD5_PARAM9_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD5_PARAM9_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD5_PARAM9_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD5_PARAM9_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD6_ Parameters

OSD6_ENABLE: Enable screen

Enable this screen

Values

Value

Meaning

0

Disabled

1

Enabled

OSD6_CHAN_MIN: Transmitter switch screen minimum pwm

This sets the PWM lower limit for this screen

Range

900 to 2100

OSD6_CHAN_MAX: Transmitter switch screen maximum pwm

This sets the PWM upper limit for this screen

Range

900 to 2100

OSD6_SAVE_X: SAVE_X

Note: This parameter is for advanced users

Horizontal position of Save button on screen

Range

0 to 25

OSD6_SAVE_Y: SAVE_Y

Note: This parameter is for advanced users

Vertical position of Save button on screen

Range

0 to 15

OSD6_PARAM1 Parameters

OSD6_PARAM1_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD6_PARAM1_X: X position

Horizontal position on screen

Range

0 to 29

OSD6_PARAM1_Y: Y position

Vertical position on screen

Range

0 to 15

OSD6_PARAM1_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD6_PARAM1_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD6_PARAM1_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD6_PARAM1_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD6_PARAM1_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD6_PARAM1_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD6_PARAM1_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD6_PARAM2 Parameters

OSD6_PARAM2_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD6_PARAM2_X: X position

Horizontal position on screen

Range

0 to 29

OSD6_PARAM2_Y: Y position

Vertical position on screen

Range

0 to 15

OSD6_PARAM2_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD6_PARAM2_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD6_PARAM2_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD6_PARAM2_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD6_PARAM2_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD6_PARAM2_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD6_PARAM2_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD6_PARAM3 Parameters

OSD6_PARAM3_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD6_PARAM3_X: X position

Horizontal position on screen

Range

0 to 29

OSD6_PARAM3_Y: Y position

Vertical position on screen

Range

0 to 15

OSD6_PARAM3_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD6_PARAM3_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD6_PARAM3_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD6_PARAM3_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD6_PARAM3_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD6_PARAM3_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD6_PARAM3_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD6_PARAM4 Parameters

OSD6_PARAM4_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD6_PARAM4_X: X position

Horizontal position on screen

Range

0 to 29

OSD6_PARAM4_Y: Y position

Vertical position on screen

Range

0 to 15

OSD6_PARAM4_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD6_PARAM4_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD6_PARAM4_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD6_PARAM4_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD6_PARAM4_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD6_PARAM4_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD6_PARAM4_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD6_PARAM5 Parameters

OSD6_PARAM5_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD6_PARAM5_X: X position

Horizontal position on screen

Range

0 to 29

OSD6_PARAM5_Y: Y position

Vertical position on screen

Range

0 to 15

OSD6_PARAM5_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD6_PARAM5_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD6_PARAM5_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD6_PARAM5_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD6_PARAM5_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD6_PARAM5_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD6_PARAM5_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD6_PARAM6 Parameters

OSD6_PARAM6_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD6_PARAM6_X: X position

Horizontal position on screen

Range

0 to 29

OSD6_PARAM6_Y: Y position

Vertical position on screen

Range

0 to 15

OSD6_PARAM6_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD6_PARAM6_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD6_PARAM6_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD6_PARAM6_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD6_PARAM6_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD6_PARAM6_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD6_PARAM6_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD6_PARAM7 Parameters

OSD6_PARAM7_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD6_PARAM7_X: X position

Horizontal position on screen

Range

0 to 29

OSD6_PARAM7_Y: Y position

Vertical position on screen

Range

0 to 15

OSD6_PARAM7_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD6_PARAM7_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD6_PARAM7_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD6_PARAM7_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD6_PARAM7_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD6_PARAM7_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD6_PARAM7_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD6_PARAM8 Parameters

OSD6_PARAM8_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD6_PARAM8_X: X position

Horizontal position on screen

Range

0 to 29

OSD6_PARAM8_Y: Y position

Vertical position on screen

Range

0 to 15

OSD6_PARAM8_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD6_PARAM8_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD6_PARAM8_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD6_PARAM8_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD6_PARAM8_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD6_PARAM8_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD6_PARAM8_TYPE: Parameter type

Type of the parameter to be displayed and modified

OSD6_PARAM9 Parameters

OSD6_PARAM9_EN: Enable

Enable setting

Values

Value

Meaning

0

Disabled

1

Enabled

OSD6_PARAM9_X: X position

Horizontal position on screen

Range

0 to 29

OSD6_PARAM9_Y: Y position

Vertical position on screen

Range

0 to 15

OSD6_PARAM9_KEY: Parameter key

Key of the parameter to be displayed and modified

OSD6_PARAM9_IDX: Parameter index

Index of the parameter to be displayed and modified

OSD6_PARAM9_GRP: Parameter group

Group of the parameter to be displayed and modified

OSD6_PARAM9_MIN: Parameter minimum

Minimum value of the parameter to be displayed and modified

OSD6_PARAM9_MAX: Parameter maximum

Maximum of the parameter to be displayed and modified

OSD6_PARAM9_INCR: Parameter increment

Increment of the parameter to be displayed and modified

OSD6_PARAM9_TYPE: Parameter type

Type of the parameter to be displayed and modified

PLND_ Parameters

PLND_ENABLED: Precision Land enabled/disabled

Note: This parameter is for advanced users

Precision Land enabled/disabled

Values

Value

Meaning

0

Disabled

1

Enabled

PLND_TYPE: Precision Land Type

Note: This parameter is for advanced users

Precision Land Type

Values

Value

Meaning

0

None

1

MAVLink

2

IRLock

3

SITL_Gazebo

4

SITL

PLND_YAW_ALIGN: Sensor yaw alignment

Note: This parameter is for advanced users

Yaw angle from body x-axis to sensor x-axis.

Increment

Range

Units

10

0 to 36000

centidegrees

PLND_LAND_OFS_X: Land offset forward

Note: This parameter is for advanced users

Desired landing position of the camera forward of the target in vehicle body frame

Increment

Range

Units

1

-20 to 20

centimeters

PLND_LAND_OFS_Y: Land offset right

Note: This parameter is for advanced users

desired landing position of the camera right of the target in vehicle body frame

Increment

Range

Units

1

-20 to 20

centimeters

PLND_EST_TYPE: Precision Land Estimator Type

Note: This parameter is for advanced users

Specifies the estimation method to be used

Values

Value

Meaning

0

RawSensor

1

KalmanFilter

PLND_ACC_P_NSE: Kalman Filter Accelerometer Noise

Note: This parameter is for advanced users

Kalman Filter Accelerometer Noise, higher values weight the input from the camera more, accels less

Range

0.5 to 5

PLND_CAM_POS_X: Camera X position offset

Note: This parameter is for advanced users

X position of the camera in body frame. Positive X is forward of the origin.

Increment

Range

Units

0.01

-5 to 5

meters

PLND_CAM_POS_Y: Camera Y position offset

Note: This parameter is for advanced users

Y position of the camera in body frame. Positive Y is to the right of the origin.

Increment

Range

Units

0.01

-5 to 5

meters

PLND_CAM_POS_Z: Camera Z position offset

Note: This parameter is for advanced users

Z position of the camera in body frame. Positive Z is down from the origin.

Increment

Range

Units

0.01

-5 to 5

meters

PLND_BUS: Sensor Bus

Note: This parameter is for advanced users

Precland sensor bus for I2C sensors.

Values

Value

Meaning

-1

DefaultBus

0

InternalI2C

1

ExternalI2C

PLND_LAG: Precision Landing sensor lag

Note: This parameter is for advanced users
Note: Reboot required after change

Precision Landing sensor lag, to cope with variable landing_target latency

Increment

Range

Units

1

0.02 to 0.250

seconds

PLND_XY_DIST_MAX: Precision Landing maximum distance to target before descending

Note: This parameter is for advanced users

The vehicle will not start descending if the landing target is detected and it is further than this many meters away. Set 0 to always descend.

Range

Units

0 to 10

meters

PLND_STRICT: PrecLand strictness

How strictly should the vehicle land on the target if target is lost

Values

Value

Meaning

0

Land Vertically (Not strict)

1

Retry Landing(Normal Strictness)

2

Do not land (just Hover) (Very Strict)

PLND_RET_MAX: PrecLand Maximum number of retires for a failed landing

PrecLand Maximum number of retires for a failed landing. Set to zero to disable landing retry.

Increment

Range

1

0 to 10

PLND_TIMEOUT: PrecLand retry timeout

Time for which vehicle continues descend even if target is lost. After this time period, vehicle will attempt a landing retry depending on PLND_STRICT parameter.

Range

Units

0 to 20

seconds

PLND_RET_BEHAVE: PrecLand retry behaviour

Prec Land will do the action selected by this parameter if a retry to a landing is needed

Values

Value

Meaning

0

Go to the last location where landing target was detected

1

Go towards the approximate location of the detected landing target

PLND_ALT_MIN: PrecLand minimum alt for retry

Vehicle will continue landing vertically even if target is lost below this height. This needs a rangefinder to work. Set to zero to disable this.

Range

Units

0 to 5

meters

PLND_ALT_MAX: PrecLand maximum alt for retry

Vehicle will continue landing vertically until this height if target is not found. Below this height if landing target is not found, landing retry/failsafe might be attempted. This needs a rangefinder to work. Set to zero to disable this.

Range

Units

0 to 50

meters

PLND_OPTIONS: Precision Landing Extra Options

Note: This parameter is for advanced users

Precision Landing Extra Options

Bitmask

Bit

Meaning

0

Moving Landing Target

1

Allow Precision Landing after manual reposition

2

Maintain high speed in final descent

PLND_ORIENT: Camera Orientation

Note: This parameter is for advanced users
Note: Reboot required after change

Orientation of camera/sensor on body

Values

Value

Meaning

0

Forward

4

Back

25

Down

PRX Parameters

PRX_IGN_GND: Proximity sensor land detection

Ignore proximity data that is within 1 meter of the ground below the vehicle. This requires a downward facing rangefinder

Values

Value

Meaning

0

Disabled

1

Enabled

PRX_LOG_RAW: Proximity raw distances log

Note: This parameter is for advanced users

Set this parameter to one if logging unfiltered(raw) distances from sensor should be enabled

Values

Value

Meaning

0

Off

1

On

PRX_FILT: Proximity filter cutoff frequency

Note: This parameter is for advanced users

Cutoff frequency for low pass filter applied to each face in the proximity boundary

Range

Units

0 to 20

hertz

PRX_ALT_MIN: Proximity lowest altitude.

Note: This parameter is for advanced users

Minimum altitude below which proximity should not work.

Range

Units

0 to 10

meters

PRX1 Parameters

PRX1_TYPE: Proximity type

Note: Reboot required after change

What type of proximity sensor is connected

Values

Value

Meaning

0

None

7

LightwareSF40c

2

MAVLink

3

TeraRangerTower

4

RangeFinder

5

RPLidarA2

6

TeraRangerTowerEvo

8

LightwareSF45B

10

SITL

12

AirSimSITL

13

CygbotD1

14

DroneCAN

15

Scripting

16

LD06

17

MR72_CAN

PRX1_ORIENT: Proximity sensor orientation

Proximity sensor orientation

Values

Value

Meaning

0

Default

1

Upside Down

PRX1_YAW_CORR: Proximity sensor yaw correction

Proximity sensor yaw correction

Range

Units

-180 to 180

degrees

PRX1_IGN_ANG1: Proximity sensor ignore angle 1

Proximity sensor ignore angle 1

Range

Units

0 to 360

degrees

PRX1_IGN_WID1: Proximity sensor ignore width 1

Proximity sensor ignore width 1

Range

Units

0 to 127

degrees

PRX1_IGN_ANG2: Proximity sensor ignore angle 2

Proximity sensor ignore angle 2

Range

Units

0 to 360

degrees

PRX1_IGN_WID2: Proximity sensor ignore width 2

Proximity sensor ignore width 2

Range

Units

0 to 127

degrees

PRX1_IGN_ANG3: Proximity sensor ignore angle 3

Proximity sensor ignore angle 3

Range

Units

0 to 360

degrees

PRX1_IGN_WID3: Proximity sensor ignore width 3

Proximity sensor ignore width 3

Range

Units

0 to 127

degrees

PRX1_IGN_ANG4: Proximity sensor ignore angle 4

Proximity sensor ignore angle 4

Range

Units

0 to 360

degrees

PRX1_IGN_WID4: Proximity sensor ignore width 4

Proximity sensor ignore width 4

Range

Units

0 to 127

degrees

PRX1_MIN: Proximity minimum range

Note: This parameter is for advanced users

Minimum expected range for Proximity Sensor. Setting this to 0 will set value to manufacturer reported range.

Range

Units

0 to 500

meters

PRX1_MAX: Proximity maximum range

Note: This parameter is for advanced users

Maximum expected range for Proximity Sensor. Setting this to 0 will set value to manufacturer reported range.

Range

Units

0 to 500

meters

PRX1_ADDR: Bus address of sensor

The bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

PRX1_ Parameters

PRX1_RECV_ID: CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

PRX2 Parameters

PRX2_TYPE: Proximity type

Note: Reboot required after change

What type of proximity sensor is connected

Values

Value

Meaning

0

None

7

LightwareSF40c

2

MAVLink

3

TeraRangerTower

4

RangeFinder

5

RPLidarA2

6

TeraRangerTowerEvo

8

LightwareSF45B

10

SITL

12

AirSimSITL

13

CygbotD1

14

DroneCAN

15

Scripting

16

LD06

17

MR72_CAN

PRX2_ORIENT: Proximity sensor orientation

Proximity sensor orientation

Values

Value

Meaning

0

Default

1

Upside Down

PRX2_YAW_CORR: Proximity sensor yaw correction

Proximity sensor yaw correction

Range

Units

-180 to 180

degrees

PRX2_IGN_ANG1: Proximity sensor ignore angle 1

Proximity sensor ignore angle 1

Range

Units

0 to 360

degrees

PRX2_IGN_WID1: Proximity sensor ignore width 1

Proximity sensor ignore width 1

Range

Units

0 to 127

degrees

PRX2_IGN_ANG2: Proximity sensor ignore angle 2

Proximity sensor ignore angle 2

Range

Units

0 to 360

degrees

PRX2_IGN_WID2: Proximity sensor ignore width 2

Proximity sensor ignore width 2

Range

Units

0 to 127

degrees

PRX2_IGN_ANG3: Proximity sensor ignore angle 3

Proximity sensor ignore angle 3

Range

Units

0 to 360

degrees

PRX2_IGN_WID3: Proximity sensor ignore width 3

Proximity sensor ignore width 3

Range

Units

0 to 127

degrees

PRX2_IGN_ANG4: Proximity sensor ignore angle 4

Proximity sensor ignore angle 4

Range

Units

0 to 360

degrees

PRX2_IGN_WID4: Proximity sensor ignore width 4

Proximity sensor ignore width 4

Range

Units

0 to 127

degrees

PRX2_MIN: Proximity minimum range

Note: This parameter is for advanced users

Minimum expected range for Proximity Sensor. Setting this to 0 will set value to manufacturer reported range.

Range

Units

0 to 500

meters

PRX2_MAX: Proximity maximum range

Note: This parameter is for advanced users

Maximum expected range for Proximity Sensor. Setting this to 0 will set value to manufacturer reported range.

Range

Units

0 to 500

meters

PRX2_ADDR: Bus address of sensor

The bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

PRX2_ Parameters

PRX2_RECV_ID: CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

PRX3 Parameters

PRX3_TYPE: Proximity type

Note: Reboot required after change

What type of proximity sensor is connected

Values

Value

Meaning

0

None

7

LightwareSF40c

2

MAVLink

3

TeraRangerTower

4

RangeFinder

5

RPLidarA2

6

TeraRangerTowerEvo

8

LightwareSF45B

10

SITL

12

AirSimSITL

13

CygbotD1

14

DroneCAN

15

Scripting

16

LD06

17

MR72_CAN

PRX3_ORIENT: Proximity sensor orientation

Proximity sensor orientation

Values

Value

Meaning

0

Default

1

Upside Down

PRX3_YAW_CORR: Proximity sensor yaw correction

Proximity sensor yaw correction

Range

Units

-180 to 180

degrees

PRX3_IGN_ANG1: Proximity sensor ignore angle 1

Proximity sensor ignore angle 1

Range

Units

0 to 360

degrees

PRX3_IGN_WID1: Proximity sensor ignore width 1

Proximity sensor ignore width 1

Range

Units

0 to 127

degrees

PRX3_IGN_ANG2: Proximity sensor ignore angle 2

Proximity sensor ignore angle 2

Range

Units

0 to 360

degrees

PRX3_IGN_WID2: Proximity sensor ignore width 2

Proximity sensor ignore width 2

Range

Units

0 to 127

degrees

PRX3_IGN_ANG3: Proximity sensor ignore angle 3

Proximity sensor ignore angle 3

Range

Units

0 to 360

degrees

PRX3_IGN_WID3: Proximity sensor ignore width 3

Proximity sensor ignore width 3

Range

Units

0 to 127

degrees

PRX3_IGN_ANG4: Proximity sensor ignore angle 4

Proximity sensor ignore angle 4

Range

Units

0 to 360

degrees

PRX3_IGN_WID4: Proximity sensor ignore width 4

Proximity sensor ignore width 4

Range

Units

0 to 127

degrees

PRX3_MIN: Proximity minimum range

Note: This parameter is for advanced users

Minimum expected range for Proximity Sensor. Setting this to 0 will set value to manufacturer reported range.

Range

Units

0 to 500

meters

PRX3_MAX: Proximity maximum range

Note: This parameter is for advanced users

Maximum expected range for Proximity Sensor. Setting this to 0 will set value to manufacturer reported range.

Range

Units

0 to 500

meters

PRX3_ADDR: Bus address of sensor

The bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

PRX3_ Parameters

PRX3_RECV_ID: CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

PRX4 Parameters

PRX4_TYPE: Proximity type

Note: Reboot required after change

What type of proximity sensor is connected

Values

Value

Meaning

0

None

7

LightwareSF40c

2

MAVLink

3

TeraRangerTower

4

RangeFinder

5

RPLidarA2

6

TeraRangerTowerEvo

8

LightwareSF45B

10

SITL

12

AirSimSITL

13

CygbotD1

14

DroneCAN

15

Scripting

16

LD06

17

MR72_CAN

PRX4_ORIENT: Proximity sensor orientation

Proximity sensor orientation

Values

Value

Meaning

0

Default

1

Upside Down

PRX4_YAW_CORR: Proximity sensor yaw correction

Proximity sensor yaw correction

Range

Units

-180 to 180

degrees

PRX4_IGN_ANG1: Proximity sensor ignore angle 1

Proximity sensor ignore angle 1

Range

Units

0 to 360

degrees

PRX4_IGN_WID1: Proximity sensor ignore width 1

Proximity sensor ignore width 1

Range

Units

0 to 127

degrees

PRX4_IGN_ANG2: Proximity sensor ignore angle 2

Proximity sensor ignore angle 2

Range

Units

0 to 360

degrees

PRX4_IGN_WID2: Proximity sensor ignore width 2

Proximity sensor ignore width 2

Range

Units

0 to 127

degrees

PRX4_IGN_ANG3: Proximity sensor ignore angle 3

Proximity sensor ignore angle 3

Range

Units

0 to 360

degrees

PRX4_IGN_WID3: Proximity sensor ignore width 3

Proximity sensor ignore width 3

Range

Units

0 to 127

degrees

PRX4_IGN_ANG4: Proximity sensor ignore angle 4

Proximity sensor ignore angle 4

Range

Units

0 to 360

degrees

PRX4_IGN_WID4: Proximity sensor ignore width 4

Proximity sensor ignore width 4

Range

Units

0 to 127

degrees

PRX4_MIN: Proximity minimum range

Note: This parameter is for advanced users

Minimum expected range for Proximity Sensor. Setting this to 0 will set value to manufacturer reported range.

Range

Units

0 to 500

meters

PRX4_MAX: Proximity maximum range

Note: This parameter is for advanced users

Maximum expected range for Proximity Sensor. Setting this to 0 will set value to manufacturer reported range.

Range

Units

0 to 500

meters

PRX4_ADDR: Bus address of sensor

The bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

PRX4_ Parameters

PRX4_RECV_ID: CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

PSC Parameters

PSC_ACC_XY_FILT: XY Acceleration filter cutoff frequency

Note: This parameter is for advanced users

Lower values will slow the response of the navigation controller and reduce twitchiness

Increment

Range

Units

0.1

0.5 to 5

hertz

PSC_POSZ_P: Position (vertical) controller P gain

Position (vertical) controller P gain. Converts the difference between the desired altitude and actual altitude into a climb or descent rate which is passed to the throttle rate controller

Range

1.000 to 3.000

PSC_VELZ_P: Velocity (vertical) controller P gain

Velocity (vertical) controller P gain. Converts the difference between desired vertical speed and actual speed into a desired acceleration that is passed to the throttle acceleration controller

Range

1.000 to 8.000

PSC_VELZ_I: Velocity (vertical) controller I gain

Note: This parameter is for advanced users

Velocity (vertical) controller I gain. Corrects long-term difference in desired velocity to a target acceleration

Increment

Range

0.01

0.02 to 1.00

PSC_VELZ_IMAX: Velocity (vertical) controller I gain maximum

Velocity (vertical) controller I gain maximum. Constrains the target acceleration that the I gain will output

Range

1.000 to 8.000

PSC_VELZ_D: Velocity (vertical) controller D gain

Note: This parameter is for advanced users

Velocity (vertical) controller D gain. Corrects short-term changes in velocity

Increment

Range

0.001

0.00 to 1.00

PSC_VELZ_FF: Velocity (vertical) controller Feed Forward gain

Note: This parameter is for advanced users

Velocity (vertical) controller Feed Forward gain. Produces an output that is proportional to the magnitude of the target

Increment

Range

0.01

0 to 1

PSC_VELZ_FLTE: Velocity (vertical) error filter

Note: This parameter is for advanced users

Velocity (vertical) error filter. This filter (in Hz) is applied to the input for P and I terms

Range

Units

0 to 100

hertz

PSC_VELZ_FLTD: Velocity (vertical) input filter for D term

Note: This parameter is for advanced users

Velocity (vertical) input filter for D term. This filter (in Hz) is applied to the input for D terms

Range

Units

0 to 100

hertz

PSC_ACCZ_P: Acceleration (vertical) controller P gain

Acceleration (vertical) controller P gain. Converts the difference between desired vertical acceleration and actual acceleration into a motor output

Increment

Range

0.05

0.200 to 1.500

PSC_ACCZ_I: Acceleration (vertical) controller I gain

Acceleration (vertical) controller I gain. Corrects long-term difference in desired vertical acceleration and actual acceleration

Range

0.000 to 3.000

PSC_ACCZ_IMAX: Acceleration (vertical) controller I gain maximum

Acceleration (vertical) controller I gain maximum. Constrains the maximum pwm that the I term will generate

Range

Units

0 to 1000

decipercent

PSC_ACCZ_D: Acceleration (vertical) controller D gain

Acceleration (vertical) controller D gain. Compensates for short-term change in desired vertical acceleration vs actual acceleration

Range

0.000 to 0.400

PSC_ACCZ_FF: Acceleration (vertical) controller feed forward

Acceleration (vertical) controller feed forward

Increment

Range

0.001

0 to 0.5

PSC_ACCZ_FLTT: Acceleration (vertical) controller target frequency in Hz

Acceleration (vertical) controller target frequency in Hz

Increment

Range

Units

1

1 to 50

hertz

PSC_ACCZ_FLTE: Acceleration (vertical) controller error frequency in Hz

Acceleration (vertical) controller error frequency in Hz

Increment

Range

Units

1

1 to 100

hertz

PSC_ACCZ_FLTD: Acceleration (vertical) controller derivative frequency in Hz

Acceleration (vertical) controller derivative frequency in Hz

Increment

Range

Units

1

1 to 100

hertz

PSC_ACCZ_SMAX: Accel (vertical) slew rate limit

Note: This parameter is for advanced users

Sets an upper limit on the slew rate produced by the combined P and D gains. If the amplitude of the control action produced by the rate feedback exceeds this value, then the D+P gain is reduced to respect the limit. This limits the amplitude of high frequency oscillations caused by an excessive gain. The limit should be set to no more than 25% of the actuators maximum slew rate to allow for load effects. Note: The gain will not be reduced to less than 10% of the nominal value. A value of zero will disable this feature.

Increment

Range

0.5

0 to 200

PSC_ACCZ_PDMX: Acceleration (vertical) controller PD sum maximum

Acceleration (vertical) controller PD sum maximum. The maximum/minimum value that the sum of the P and D term can output

Range

Units

0 to 1000

decipercent

PSC_ACCZ_D_FF: Accel (vertical) Derivative FeedForward Gain

Note: This parameter is for advanced users

FF D Gain which produces an output that is proportional to the rate of change of the target

Increment

Range

0.0001

0 to 0.02

PSC_ACCZ_NTF: Accel (vertical) Target notch filter index

Note: This parameter is for advanced users

Accel (vertical) Target notch filter index

Range

1 to 8

PSC_ACCZ_NEF: Accel (vertical) Error notch filter index

Note: This parameter is for advanced users

Accel (vertical) Error notch filter index

Range

1 to 8

PSC_POSXY_P: Position (horizontal) controller P gain

Position controller P gain. Converts the distance (in the latitude direction) to the target location into a desired speed which is then passed to the loiter latitude rate controller

Range

0.500 to 2.000

PSC_VELXY_P: Velocity (horizontal) P gain

Note: This parameter is for advanced users

Velocity (horizontal) P gain. Converts the difference between desired and actual velocity to a target acceleration

Increment

Range

0.1

0.1 to 6.0

PSC_VELXY_I: Velocity (horizontal) I gain

Note: This parameter is for advanced users

Velocity (horizontal) I gain. Corrects long-term difference between desired and actual velocity to a target acceleration

Increment

Range

0.01

0.02 to 1.00

PSC_VELXY_D: Velocity (horizontal) D gain

Note: This parameter is for advanced users

Velocity (horizontal) D gain. Corrects short-term changes in velocity

Increment

Range

0.001

0.00 to 1.00

PSC_VELXY_IMAX: Velocity (horizontal) integrator maximum

Note: This parameter is for advanced users

Velocity (horizontal) integrator maximum. Constrains the target acceleration that the I gain will output

Increment

Range

Units

10

0 to 4500

centimeters per square second

PSC_VELXY_FLTE: Velocity (horizontal) input filter

Note: This parameter is for advanced users

Velocity (horizontal) input filter. This filter (in Hz) is applied to the input for P and I terms

Range

Units

0 to 100

hertz

PSC_VELXY_FLTD: Velocity (horizontal) input filter

Note: This parameter is for advanced users

Velocity (horizontal) input filter. This filter (in Hz) is applied to the input for D term

Range

Units

0 to 100

hertz

PSC_VELXY_FF: Velocity (horizontal) feed forward gain

Note: This parameter is for advanced users

Velocity (horizontal) feed forward gain. Converts the difference between desired velocity to a target acceleration

Increment

Range

0.01

0 to 6

PSC_ANGLE_MAX: Position Control Angle Max

Note: This parameter is for advanced users

Maximum lean angle autopilot can request. Set to zero to use ANGLE_MAX parameter value

Increment

Range

Units

1

0 to 45

degrees

PSC_JERK_XY: Jerk limit for the horizontal kinematic input shaping

Note: This parameter is for advanced users

Jerk limit of the horizontal kinematic path generation used to determine how quickly the aircraft varies the acceleration target

Increment

Range

Units

1

1 to 20

meters per cubic second

PSC_JERK_Z: Jerk limit for the vertical kinematic input shaping

Note: This parameter is for advanced users

Jerk limit of the vertical kinematic path generation used to determine how quickly the aircraft varies the acceleration target

Increment

Range

Units

1

5 to 50

meters per cubic second

RALLY_ Parameters

RALLY_TOTAL: Rally Total

Note: This parameter is for advanced users

Number of rally points currently loaded

RALLY_LIMIT_KM: Rally Limit

Note: This parameter is for advanced users

Maximum distance to rally point. If the closest rally point is more than this number of kilometers from the current position and the home location is closer than any of the rally points from the current position then do RTL to home rather than to the closest rally point. This prevents a leftover rally point from a different airfield being used accidentally. If this is set to 0 then the closest rally point is always used.

Increment

Units

0.1

kilometers

RALLY_INCL_HOME: Rally Include Home

Controls if Home is included as a Rally point (i.e. as a safe landing place) for RTL

Values

Value

Meaning

0

DoNotIncludeHome

1

IncludeHome

RC Parameters

RC_OVERRIDE_TIME: RC override timeout

Note: This parameter is for advanced users

Timeout after which RC overrides will no longer be used, and RC input will resume, 0 will disable RC overrides, -1 will never timeout, and continue using overrides until they are disabled

Range

Units

0.0 to 120.0

seconds

RC_OPTIONS: RC options

Note: This parameter is for advanced users

RC input options

Bitmask

Bit

Meaning

0

Ignore RC Receiver

1

Ignore MAVLink Overrides

2

Ignore Receiver Failsafe bit but allow other RC failsafes if setup

3

FPort Pad

4

Log RC input bytes

5

Arming check throttle for 0 input

6

Skip the arming check for neutral Roll/Pitch/Yaw sticks

7

Allow Switch reverse

8

Use passthrough for CRSF telemetry

9

Suppress CRSF mode/rate message for ELRS systems

10

Enable multiple receiver support

11

Use Link Quality for RSSI with CRSF

12

Annotate CRSF flight mode with * on disarm

13

Use 420kbaud for ELRS protocol

RC_PROTOCOLS: RC protocols enabled

Note: This parameter is for advanced users

Bitmask of enabled RC protocols. Allows narrowing the protocol detection to only specific types of RC receivers which can avoid issues with incorrect detection. Set to 1 to enable all protocols.

Bitmask

Bit

Meaning

0

All

1

PPM

2

IBUS

3

SBUS

4

SBUS_NI

5

DSM

6

SUMD

7

SRXL

8

SRXL2

9

CRSF

10

ST24

11

FPORT

12

FPORT2

13

FastSBUS

14

DroneCAN

15

Ghost

16

MAVRadio

RC_FS_TIMEOUT: RC Failsafe timeout

RC failsafe will trigger this many seconds after loss of RC

Range

Units

0.5 to 10.0

seconds

RC10_ Parameters

RC10_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC10_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC10_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC10_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC10_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC10_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC11_ Parameters

RC11_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC11_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC11_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC11_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC11_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC11_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC12_ Parameters

RC12_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC12_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC12_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC12_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC12_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC12_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC13_ Parameters

RC13_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC13_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC13_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC13_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC13_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC13_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC14_ Parameters

RC14_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC14_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC14_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC14_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC14_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC14_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC15_ Parameters

RC15_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC15_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC15_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC15_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC15_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC15_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC16_ Parameters

RC16_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC16_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC16_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC16_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC16_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC16_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC1_ Parameters

RC1_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC1_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC1_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC1_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC1_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC1_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC2_ Parameters

RC2_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC2_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC2_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC2_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC2_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC2_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC3_ Parameters

RC3_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC3_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC3_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC3_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC3_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC3_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC4_ Parameters

RC4_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC4_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC4_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC4_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC4_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC4_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC5_ Parameters

RC5_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC5_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC5_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC5_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC5_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC5_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC6_ Parameters

RC6_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC6_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC6_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC6_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC6_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC6_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC7_ Parameters

RC7_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC7_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC7_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC7_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC7_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC7_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC8_ Parameters

RC8_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC8_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC8_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC8_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC8_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC8_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RC9_ Parameters

RC9_MIN: RC min PWM

Note: This parameter is for advanced users

RC minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC9_TRIM: RC trim PWM

Note: This parameter is for advanced users

RC trim (neutral) PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC9_MAX: RC max PWM

Note: This parameter is for advanced users

RC maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

RC9_REVERSED: RC reversed

Note: This parameter is for advanced users

Reverse channel input. Set to 0 for normal operation. Set to 1 to reverse this input channel.

Values

Value

Meaning

0

Normal

1

Reversed

RC9_DZ: RC dead-zone

Note: This parameter is for advanced users

PWM dead zone in microseconds around trim or bottom

Range

Units

0 to 200

PWM in microseconds

RC9_OPTION: RC input option

Function assigned to this RC channel

Values

Value

Meaning

0

Do Nothing

2

FLIP Mode

3

Simple Mode

4

RTL

5

Save Trim

7

Save WP

9

Camera Trigger

10

RangeFinder Enable

11

Fence Enable

13

Super Simple Mode

14

Acro Trainer

15

Sprayer Enable

16

AUTO Mode

17

AUTOTUNE Mode

18

LAND Mode

19

Gripper Release

21

Parachute Enable

22

Parachute Release

23

Parachute 3pos

24

Auto Mission Reset

25

AttCon Feed Forward

26

AttCon Accel Limits

27

Retract Mount1

28

Relay1 On/Off

29

Landing Gear

30

Lost Copter Sound

31

Motor Emergency Stop

32

Motor Interlock

33

BRAKE Mode

34

Relay2 On/Off

35

Relay3 On/Off

36

Relay4 On/Off

37

THROW Mode

38

ADSB Avoidance Enable

39

PrecLoiter Enable

40

Proximity Avoidance Enable

41

ArmDisarm (4.1 and lower)

42

SMARTRTL Mode

43

InvertedFlight Enable

44

Winch Enable

45

Winch Control

46

RC Override Enable

47

User Function 1

48

User Function 2

49

User Function 3

52

ACRO Mode

55

GUIDED Mode

56

LOITER Mode

57

FOLLOW Mode

58

Clear Waypoints

60

ZigZag Mode

61

ZigZag SaveWP

62

Compass Learn

65

GPS Disable

66

Relay5 On/Off

67

Relay6 On/Off

68

STABILIZE Mode

69

POSHOLD Mode

70

ALTHOLD Mode

71

FLOWHOLD Mode

72

CIRCLE Mode

73

DRIFT Mode

75

SurfaceTrackingUpDown

76

STANDBY Mode

78

RunCam Control

79

RunCam OSD Control

80

VisOdom Align

81

Disarm

83

ZigZag Auto

84

AirMode

85

Generator

90

EKF Source Set

94

VTX Power

99

AUTO RTL

100

KillIMU1

101

KillIMU2

102

Camera Mode Toggle

105

GPS Disable Yaw

109

use Custom Controller

110

KillIMU3

112

SwitchExternalAHRS

113

Retract Mount2

151

TURTLE Mode

152

SIMPLE heading reset

153

ArmDisarm (4.2 and higher)

154

ArmDisarm with AirMode (4.2 and higher)

158

Optflow Calibration

159

Force IS_Flying

161

Turbine Start(heli)

162

FFT Tune

163

Mount Lock

164

Pause Stream Logging

165

Arm/Emergency Motor Stop

166

Camera Record Video

167

Camera Zoom

168

Camera Manual Focus

169

Camera Auto Focus

171

Calibrate Compasses

172

Battery MPPT Enable

174

Camera Image Tracking

175

Camera Lens

177

Mount LRF enable

178

FlightMode Pause/Resume

180

Test autotuned gains after tune is complete

212

Mount1 Roll

213

Mount1 Pitch

214

Mount1 Yaw

215

Mount2 Roll

216

Mount2 Pitch

217

Mount2 Yaw

219

Transmitter Tuning

300

Scripting1

301

Scripting2

302

Scripting3

303

Scripting4

304

Scripting5

305

Scripting6

306

Scripting7

307

Scripting8

RCMAP_ Parameters

RCMAP_ROLL: Roll channel

Note: This parameter is for advanced users
Note: Reboot required after change

Roll channel number. This is useful when you have a RC transmitter that can't change the channel order easily. Roll is normally on channel 1, but you can move it to any channel with this parameter. Reboot is required for changes to take effect.

Increment

Range

1

1 to 16

RCMAP_PITCH: Pitch channel

Note: This parameter is for advanced users
Note: Reboot required after change

Pitch channel number. This is useful when you have a RC transmitter that can't change the channel order easily. Pitch is normally on channel 2, but you can move it to any channel with this parameter. Reboot is required for changes to take effect.

Increment

Range

1

1 to 16

RCMAP_THROTTLE: Throttle channel

Note: This parameter is for advanced users
Note: Reboot required after change

Throttle channel number. This is useful when you have a RC transmitter that can't change the channel order easily. Throttle is normally on channel 3, but you can move it to any channel with this parameter. Reboot is required for changes to take effect.

Increment

Range

1

1 to 16

RCMAP_YAW: Yaw channel

Note: This parameter is for advanced users
Note: Reboot required after change

Yaw channel number. This is useful when you have a RC transmitter that can't change the channel order easily. Yaw (also known as rudder) is normally on channel 4, but you can move it to any channel with this parameter. Reboot is required for changes to take effect.

Increment

Range

1

1 to 16

RELAY10_ Parameters

RELAY10_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY10_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY10_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY10_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY11_ Parameters

RELAY11_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY11_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY11_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY11_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY12_ Parameters

RELAY12_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY12_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY12_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY12_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY13_ Parameters

RELAY13_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY13_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY13_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY13_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY14_ Parameters

RELAY14_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY14_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY14_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY14_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY15_ Parameters

RELAY15_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY15_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY15_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY15_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY16_ Parameters

RELAY16_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY16_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY16_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY16_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY1_ Parameters

RELAY1_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY1_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY1_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY1_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY2_ Parameters

RELAY2_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY2_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY2_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY2_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY3_ Parameters

RELAY3_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY3_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY3_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY3_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY4_ Parameters

RELAY4_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY4_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY4_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY4_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY5_ Parameters

RELAY5_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY5_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY5_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY5_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY6_ Parameters

RELAY6_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY6_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY6_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY6_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY7_ Parameters

RELAY7_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY7_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY7_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY7_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY8_ Parameters

RELAY8_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY8_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY8_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY8_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RELAY9_ Parameters

RELAY9_FUNCTION: Relay function

The function the relay channel is mapped to.

Values

Value

Meaning

0

None

1

Relay

3

Parachute

4

Camera

RELAY9_PIN: Relay pin

Digital pin number for relay control. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

49

BB Blue GP0 pin 4

50

AUXOUT1

51

AUXOUT2

52

AUXOUT3

53

AUXOUT4

54

AUXOUT5

55

AUXOUT6

57

BB Blue GP0 pin 3

113

BB Blue GP0 pin 6

116

BB Blue GP0 pin 5

62

BBBMini Pin P8.13

101

MainOut1

102

MainOut2

103

MainOut3

104

MainOut4

105

MainOut5

106

MainOut6

107

MainOut7

108

MainOut8

1000

DroneCAN Hardpoint ID 0

1001

DroneCAN Hardpoint ID 1

1002

DroneCAN Hardpoint ID 2

1003

DroneCAN Hardpoint ID 3

1004

DroneCAN Hardpoint ID 4

1005

DroneCAN Hardpoint ID 5

1006

DroneCAN Hardpoint ID 6

1007

DroneCAN Hardpoint ID 7

1008

DroneCAN Hardpoint ID 8

1009

DroneCAN Hardpoint ID 9

1010

DroneCAN Hardpoint ID 10

1011

DroneCAN Hardpoint ID 11

1012

DroneCAN Hardpoint ID 12

1013

DroneCAN Hardpoint ID 13

1014

DroneCAN Hardpoint ID 14

1015

DroneCAN Hardpoint ID 15

RELAY9_DEFAULT: Relay default state

Should the relay default to on or off, this only applies to RELAYx_FUNC "Relay" (1). All other uses will pick the appropriate default output state from within the controlling function's parameters. Note that if INVERTED is set then the default is inverted.

Values

Value

Meaning

0

Off

1

On

2

NoChange

RELAY9_INVERTED: Relay invert output signal

Should the relay output signal be inverted. If enabled, relay on would be pin low and relay off would be pin high. NOTE: this impact's DEFAULT.

Values

Value

Meaning

0

Normal

1

Inverted

RNGFND1_ Parameters

RNGFND1_TYPE: Rangefinder type

Type of connected rangefinder

Values

Value

Meaning

0

None

1

Analog

2

MaxbotixI2C

3

LidarLite-I2C

5

PWM

6

BBB-PRU

7

LightWareI2C

8

LightWareSerial

9

Bebop

10

MAVLink

11

USD1_Serial

12

LeddarOne

13

MaxbotixSerial

14

TeraRangerI2C

15

LidarLiteV3-I2C

16

VL53L0X or VL53L1X

17

NMEA

18

WASP-LRF

19

BenewakeTF02

20

Benewake-Serial

21

LidarLightV3HP

22

PWM

23

BlueRoboticsPing

24

DroneCAN

25

BenewakeTFminiPlus-I2C

26

LanbaoPSK-CM8JL65-CC5

27

BenewakeTF03

28

VL53L1X-ShortRange

29

LeddarVu8-Serial

30

HC-SR04

31

GYUS42v2

32

MSP

33

USD1_CAN

34

Benewake_CAN

35

TeraRangerSerial

36

Lua_Scripting

37

NoopLoop_TOFSense

38

NoopLoop_TOFSense_CAN

39

NRA24_CAN

40

NoopLoop_TOFSenseF_I2C

41

JRE_Serial

42

Ainstein_LR_D1

43

RDS02UF

100

SITL

RNGFND1_PIN: Rangefinder pin

Analog or PWM input pin that rangefinder is connected to. Analog RSSI or Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

-1

Not Used

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RNGFND1_SCALING: Rangefinder scaling

Scaling factor between rangefinder reading and distance. For the linear and inverted functions this is in meters per volt. For the hyperbolic function the units are meterVolts. For Maxbotix serial sonar this is unit conversion to meters.

Increment

Units

0.001

meters per volt

RNGFND1_OFFSET: rangefinder offset

Offset in volts for zero distance for analog rangefinders. Offset added to distance in centimeters for PWM lidars

Increment

Units

0.001

volt

RNGFND1_FUNCTION: Rangefinder function

Control over what function is used to calculate distance. For a linear function, the distance is (voltage-offset)*scaling. For a inverted function the distance is (offset-voltage)*scaling. For a hyperbolic function the distance is scaling/(voltage-offset). The functions return the distance in meters.

Values

Value

Meaning

0

Linear

1

Inverted

2

Hyperbolic

RNGFND1_MIN_CM: Rangefinder minimum distance

Minimum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND1_MAX_CM: Rangefinder maximum distance

Maximum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND1_STOP_PIN: Rangefinder stop pin

Digital pin that enables/disables rangefinder measurement for the pwm rangefinder. A value of -1 means no pin. If this is set, then the pin is set to 1 to enable the rangefinder and set to 0 to disable it. This is used to enable powersaving when out of range. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Not Used

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

111

PX4 FMU Relay1

112

PX4 FMU Relay2

113

PX4IO Relay1

114

PX4IO Relay2

115

PX4IO ACC1

116

PX4IO ACC2

RNGFND1_RMETRIC: Ratiometric

This parameter sets whether an analog rangefinder is ratiometric. Most analog rangefinders are ratiometric, meaning that their output voltage is influenced by the supply voltage. Some analog rangefinders (such as the SF/02) have their own internal voltage regulators so they are not ratiometric.

Values

Value

Meaning

0

No

1

Yes

RNGFND1_PWRRNG: Powersave range

This parameter sets the estimated terrain distance in meters above which the sensor will be put into a power saving mode (if available). A value of zero means power saving is not enabled

Range

Units

0 to 32767

meters

RNGFND1_GNDCLEAR: Distance (in cm) from the range finder to the ground

This parameter sets the expected range measurement(in cm) that the range finder should return when the vehicle is on the ground.

Increment

Range

Units

1

5 to 127

centimeters

RNGFND1_ADDR: Bus address of sensor

This sets the bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

RNGFND1_POS_X: X position offset

Note: This parameter is for advanced users

X position of the rangefinder in body frame. Positive X is forward of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND1_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the rangefinder in body frame. Positive Y is to the right of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND1_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the rangefinder in body frame. Positive Z is down from the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND1_ORIENT: Rangefinder orientation

Note: This parameter is for advanced users

Orientation of rangefinder

Values

Value

Meaning

0

Forward

1

Forward-Right

2

Right

3

Back-Right

4

Back

5

Back-Left

6

Left

7

Forward-Left

24

Up

25

Down

RNGFND1_WSP_MAVG: Moving Average Range

Note: This parameter is for advanced users

Sets the number of historic range results to use for calculating the current range result. When MAVG is greater than 1, the current range result will be the current measured value averaged with the N-1 previous results

Range

0 to 255

RNGFND1_WSP_MEDF: Moving Median Filter

Note: This parameter is for advanced users

Sets the window size for the real-time median filter. When MEDF is greater than 0 the median filter is active

Range

0 to 255

RNGFND1_WSP_FRQ: Frequency

Note: This parameter is for advanced users

Sets the repetition frequency of the ranging operation in Hertz. Upon entering the desired frequency the system will calculate the nearest frequency that it can handle according to the resolution of internal timers.

Range

0 to 10000

RNGFND1_WSP_AVG: Multi-pulse averages

Note: This parameter is for advanced users

Sets the number of pulses to be used in multi-pulse averaging mode. In this mode, a sequence of rapid fire ranges are taken and then averaged to improve the accuracy of the measurement

Range

0 to 255

RNGFND1_WSP_THR: Sensitivity threshold

Note: This parameter is for advanced users

Sets the system sensitivity. Larger values of THR represent higher sensitivity. The system may limit the maximum value of THR to prevent excessive false alarm rates based on settings made at the factory. Set to -1 for automatic threshold adjustments

Range

-1 to 255

RNGFND1_WSP_BAUD: Baud rate

Note: This parameter is for advanced users

Desired baud rate

Values

Value

Meaning

0

Low Speed

1

High Speed

RNGFND1_RECV_ID: RangeFinder CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

RNGFND1_SNR_MIN: RangeFinder Minimum signal strength

Note: This parameter is for advanced users

RangeFinder Minimum signal strength (SNR) to accept distance

Range

0 to 65535

RNGFND2_ Parameters

RNGFND2_TYPE: Rangefinder type

Type of connected rangefinder

Values

Value

Meaning

0

None

1

Analog

2

MaxbotixI2C

3

LidarLite-I2C

5

PWM

6

BBB-PRU

7

LightWareI2C

8

LightWareSerial

9

Bebop

10

MAVLink

11

USD1_Serial

12

LeddarOne

13

MaxbotixSerial

14

TeraRangerI2C

15

LidarLiteV3-I2C

16

VL53L0X or VL53L1X

17

NMEA

18

WASP-LRF

19

BenewakeTF02

20

Benewake-Serial

21

LidarLightV3HP

22

PWM

23

BlueRoboticsPing

24

DroneCAN

25

BenewakeTFminiPlus-I2C

26

LanbaoPSK-CM8JL65-CC5

27

BenewakeTF03

28

VL53L1X-ShortRange

29

LeddarVu8-Serial

30

HC-SR04

31

GYUS42v2

32

MSP

33

USD1_CAN

34

Benewake_CAN

35

TeraRangerSerial

36

Lua_Scripting

37

NoopLoop_TOFSense

38

NoopLoop_TOFSense_CAN

39

NRA24_CAN

40

NoopLoop_TOFSenseF_I2C

41

JRE_Serial

42

Ainstein_LR_D1

43

RDS02UF

100

SITL

RNGFND2_PIN: Rangefinder pin

Analog or PWM input pin that rangefinder is connected to. Analog RSSI or Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

-1

Not Used

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RNGFND2_SCALING: Rangefinder scaling

Scaling factor between rangefinder reading and distance. For the linear and inverted functions this is in meters per volt. For the hyperbolic function the units are meterVolts. For Maxbotix serial sonar this is unit conversion to meters.

Increment

Units

0.001

meters per volt

RNGFND2_OFFSET: rangefinder offset

Offset in volts for zero distance for analog rangefinders. Offset added to distance in centimeters for PWM lidars

Increment

Units

0.001

volt

RNGFND2_FUNCTION: Rangefinder function

Control over what function is used to calculate distance. For a linear function, the distance is (voltage-offset)*scaling. For a inverted function the distance is (offset-voltage)*scaling. For a hyperbolic function the distance is scaling/(voltage-offset). The functions return the distance in meters.

Values

Value

Meaning

0

Linear

1

Inverted

2

Hyperbolic

RNGFND2_MIN_CM: Rangefinder minimum distance

Minimum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND2_MAX_CM: Rangefinder maximum distance

Maximum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND2_STOP_PIN: Rangefinder stop pin

Digital pin that enables/disables rangefinder measurement for the pwm rangefinder. A value of -1 means no pin. If this is set, then the pin is set to 1 to enable the rangefinder and set to 0 to disable it. This is used to enable powersaving when out of range. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Not Used

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

111

PX4 FMU Relay1

112

PX4 FMU Relay2

113

PX4IO Relay1

114

PX4IO Relay2

115

PX4IO ACC1

116

PX4IO ACC2

RNGFND2_RMETRIC: Ratiometric

This parameter sets whether an analog rangefinder is ratiometric. Most analog rangefinders are ratiometric, meaning that their output voltage is influenced by the supply voltage. Some analog rangefinders (such as the SF/02) have their own internal voltage regulators so they are not ratiometric.

Values

Value

Meaning

0

No

1

Yes

RNGFND2_PWRRNG: Powersave range

This parameter sets the estimated terrain distance in meters above which the sensor will be put into a power saving mode (if available). A value of zero means power saving is not enabled

Range

Units

0 to 32767

meters

RNGFND2_GNDCLEAR: Distance (in cm) from the range finder to the ground

This parameter sets the expected range measurement(in cm) that the range finder should return when the vehicle is on the ground.

Increment

Range

Units

1

5 to 127

centimeters

RNGFND2_ADDR: Bus address of sensor

This sets the bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

RNGFND2_POS_X: X position offset

Note: This parameter is for advanced users

X position of the rangefinder in body frame. Positive X is forward of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND2_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the rangefinder in body frame. Positive Y is to the right of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND2_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the rangefinder in body frame. Positive Z is down from the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND2_ORIENT: Rangefinder orientation

Note: This parameter is for advanced users

Orientation of rangefinder

Values

Value

Meaning

0

Forward

1

Forward-Right

2

Right

3

Back-Right

4

Back

5

Back-Left

6

Left

7

Forward-Left

24

Up

25

Down

RNGFND2_WSP_MAVG: Moving Average Range

Note: This parameter is for advanced users

Sets the number of historic range results to use for calculating the current range result. When MAVG is greater than 1, the current range result will be the current measured value averaged with the N-1 previous results

Range

0 to 255

RNGFND2_WSP_MEDF: Moving Median Filter

Note: This parameter is for advanced users

Sets the window size for the real-time median filter. When MEDF is greater than 0 the median filter is active

Range

0 to 255

RNGFND2_WSP_FRQ: Frequency

Note: This parameter is for advanced users

Sets the repetition frequency of the ranging operation in Hertz. Upon entering the desired frequency the system will calculate the nearest frequency that it can handle according to the resolution of internal timers.

Range

0 to 10000

RNGFND2_WSP_AVG: Multi-pulse averages

Note: This parameter is for advanced users

Sets the number of pulses to be used in multi-pulse averaging mode. In this mode, a sequence of rapid fire ranges are taken and then averaged to improve the accuracy of the measurement

Range

0 to 255

RNGFND2_WSP_THR: Sensitivity threshold

Note: This parameter is for advanced users

Sets the system sensitivity. Larger values of THR represent higher sensitivity. The system may limit the maximum value of THR to prevent excessive false alarm rates based on settings made at the factory. Set to -1 for automatic threshold adjustments

Range

-1 to 255

RNGFND2_WSP_BAUD: Baud rate

Note: This parameter is for advanced users

Desired baud rate

Values

Value

Meaning

0

Low Speed

1

High Speed

RNGFND2_RECV_ID: RangeFinder CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

RNGFND2_SNR_MIN: RangeFinder Minimum signal strength

Note: This parameter is for advanced users

RangeFinder Minimum signal strength (SNR) to accept distance

Range

0 to 65535

RNGFND3_ Parameters

RNGFND3_TYPE: Rangefinder type

Type of connected rangefinder

Values

Value

Meaning

0

None

1

Analog

2

MaxbotixI2C

3

LidarLite-I2C

5

PWM

6

BBB-PRU

7

LightWareI2C

8

LightWareSerial

9

Bebop

10

MAVLink

11

USD1_Serial

12

LeddarOne

13

MaxbotixSerial

14

TeraRangerI2C

15

LidarLiteV3-I2C

16

VL53L0X or VL53L1X

17

NMEA

18

WASP-LRF

19

BenewakeTF02

20

Benewake-Serial

21

LidarLightV3HP

22

PWM

23

BlueRoboticsPing

24

DroneCAN

25

BenewakeTFminiPlus-I2C

26

LanbaoPSK-CM8JL65-CC5

27

BenewakeTF03

28

VL53L1X-ShortRange

29

LeddarVu8-Serial

30

HC-SR04

31

GYUS42v2

32

MSP

33

USD1_CAN

34

Benewake_CAN

35

TeraRangerSerial

36

Lua_Scripting

37

NoopLoop_TOFSense

38

NoopLoop_TOFSense_CAN

39

NRA24_CAN

40

NoopLoop_TOFSenseF_I2C

41

JRE_Serial

42

Ainstein_LR_D1

43

RDS02UF

100

SITL

RNGFND3_PIN: Rangefinder pin

Analog or PWM input pin that rangefinder is connected to. Analog RSSI or Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

-1

Not Used

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RNGFND3_SCALING: Rangefinder scaling

Scaling factor between rangefinder reading and distance. For the linear and inverted functions this is in meters per volt. For the hyperbolic function the units are meterVolts. For Maxbotix serial sonar this is unit conversion to meters.

Increment

Units

0.001

meters per volt

RNGFND3_OFFSET: rangefinder offset

Offset in volts for zero distance for analog rangefinders. Offset added to distance in centimeters for PWM lidars

Increment

Units

0.001

volt

RNGFND3_FUNCTION: Rangefinder function

Control over what function is used to calculate distance. For a linear function, the distance is (voltage-offset)*scaling. For a inverted function the distance is (offset-voltage)*scaling. For a hyperbolic function the distance is scaling/(voltage-offset). The functions return the distance in meters.

Values

Value

Meaning

0

Linear

1

Inverted

2

Hyperbolic

RNGFND3_MIN_CM: Rangefinder minimum distance

Minimum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND3_MAX_CM: Rangefinder maximum distance

Maximum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND3_STOP_PIN: Rangefinder stop pin

Digital pin that enables/disables rangefinder measurement for the pwm rangefinder. A value of -1 means no pin. If this is set, then the pin is set to 1 to enable the rangefinder and set to 0 to disable it. This is used to enable powersaving when out of range. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Not Used

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

111

PX4 FMU Relay1

112

PX4 FMU Relay2

113

PX4IO Relay1

114

PX4IO Relay2

115

PX4IO ACC1

116

PX4IO ACC2

RNGFND3_RMETRIC: Ratiometric

This parameter sets whether an analog rangefinder is ratiometric. Most analog rangefinders are ratiometric, meaning that their output voltage is influenced by the supply voltage. Some analog rangefinders (such as the SF/02) have their own internal voltage regulators so they are not ratiometric.

Values

Value

Meaning

0

No

1

Yes

RNGFND3_PWRRNG: Powersave range

This parameter sets the estimated terrain distance in meters above which the sensor will be put into a power saving mode (if available). A value of zero means power saving is not enabled

Range

Units

0 to 32767

meters

RNGFND3_GNDCLEAR: Distance (in cm) from the range finder to the ground

This parameter sets the expected range measurement(in cm) that the range finder should return when the vehicle is on the ground.

Increment

Range

Units

1

5 to 127

centimeters

RNGFND3_ADDR: Bus address of sensor

This sets the bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

RNGFND3_POS_X: X position offset

Note: This parameter is for advanced users

X position of the rangefinder in body frame. Positive X is forward of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND3_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the rangefinder in body frame. Positive Y is to the right of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND3_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the rangefinder in body frame. Positive Z is down from the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND3_ORIENT: Rangefinder orientation

Note: This parameter is for advanced users

Orientation of rangefinder

Values

Value

Meaning

0

Forward

1

Forward-Right

2

Right

3

Back-Right

4

Back

5

Back-Left

6

Left

7

Forward-Left

24

Up

25

Down

RNGFND3_WSP_MAVG: Moving Average Range

Note: This parameter is for advanced users

Sets the number of historic range results to use for calculating the current range result. When MAVG is greater than 1, the current range result will be the current measured value averaged with the N-1 previous results

Range

0 to 255

RNGFND3_WSP_MEDF: Moving Median Filter

Note: This parameter is for advanced users

Sets the window size for the real-time median filter. When MEDF is greater than 0 the median filter is active

Range

0 to 255

RNGFND3_WSP_FRQ: Frequency

Note: This parameter is for advanced users

Sets the repetition frequency of the ranging operation in Hertz. Upon entering the desired frequency the system will calculate the nearest frequency that it can handle according to the resolution of internal timers.

Range

0 to 10000

RNGFND3_WSP_AVG: Multi-pulse averages

Note: This parameter is for advanced users

Sets the number of pulses to be used in multi-pulse averaging mode. In this mode, a sequence of rapid fire ranges are taken and then averaged to improve the accuracy of the measurement

Range

0 to 255

RNGFND3_WSP_THR: Sensitivity threshold

Note: This parameter is for advanced users

Sets the system sensitivity. Larger values of THR represent higher sensitivity. The system may limit the maximum value of THR to prevent excessive false alarm rates based on settings made at the factory. Set to -1 for automatic threshold adjustments

Range

-1 to 255

RNGFND3_WSP_BAUD: Baud rate

Note: This parameter is for advanced users

Desired baud rate

Values

Value

Meaning

0

Low Speed

1

High Speed

RNGFND3_RECV_ID: RangeFinder CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

RNGFND3_SNR_MIN: RangeFinder Minimum signal strength

Note: This parameter is for advanced users

RangeFinder Minimum signal strength (SNR) to accept distance

Range

0 to 65535

RNGFND4_ Parameters

RNGFND4_TYPE: Rangefinder type

Type of connected rangefinder

Values

Value

Meaning

0

None

1

Analog

2

MaxbotixI2C

3

LidarLite-I2C

5

PWM

6

BBB-PRU

7

LightWareI2C

8

LightWareSerial

9

Bebop

10

MAVLink

11

USD1_Serial

12

LeddarOne

13

MaxbotixSerial

14

TeraRangerI2C

15

LidarLiteV3-I2C

16

VL53L0X or VL53L1X

17

NMEA

18

WASP-LRF

19

BenewakeTF02

20

Benewake-Serial

21

LidarLightV3HP

22

PWM

23

BlueRoboticsPing

24

DroneCAN

25

BenewakeTFminiPlus-I2C

26

LanbaoPSK-CM8JL65-CC5

27

BenewakeTF03

28

VL53L1X-ShortRange

29

LeddarVu8-Serial

30

HC-SR04

31

GYUS42v2

32

MSP

33

USD1_CAN

34

Benewake_CAN

35

TeraRangerSerial

36

Lua_Scripting

37

NoopLoop_TOFSense

38

NoopLoop_TOFSense_CAN

39

NRA24_CAN

40

NoopLoop_TOFSenseF_I2C

41

JRE_Serial

42

Ainstein_LR_D1

43

RDS02UF

100

SITL

RNGFND4_PIN: Rangefinder pin

Analog or PWM input pin that rangefinder is connected to. Analog RSSI or Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

-1

Not Used

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RNGFND4_SCALING: Rangefinder scaling

Scaling factor between rangefinder reading and distance. For the linear and inverted functions this is in meters per volt. For the hyperbolic function the units are meterVolts. For Maxbotix serial sonar this is unit conversion to meters.

Increment

Units

0.001

meters per volt

RNGFND4_OFFSET: rangefinder offset

Offset in volts for zero distance for analog rangefinders. Offset added to distance in centimeters for PWM lidars

Increment

Units

0.001

volt

RNGFND4_FUNCTION: Rangefinder function

Control over what function is used to calculate distance. For a linear function, the distance is (voltage-offset)*scaling. For a inverted function the distance is (offset-voltage)*scaling. For a hyperbolic function the distance is scaling/(voltage-offset). The functions return the distance in meters.

Values

Value

Meaning

0

Linear

1

Inverted

2

Hyperbolic

RNGFND4_MIN_CM: Rangefinder minimum distance

Minimum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND4_MAX_CM: Rangefinder maximum distance

Maximum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND4_STOP_PIN: Rangefinder stop pin

Digital pin that enables/disables rangefinder measurement for the pwm rangefinder. A value of -1 means no pin. If this is set, then the pin is set to 1 to enable the rangefinder and set to 0 to disable it. This is used to enable powersaving when out of range. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Not Used

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

111

PX4 FMU Relay1

112

PX4 FMU Relay2

113

PX4IO Relay1

114

PX4IO Relay2

115

PX4IO ACC1

116

PX4IO ACC2

RNGFND4_RMETRIC: Ratiometric

This parameter sets whether an analog rangefinder is ratiometric. Most analog rangefinders are ratiometric, meaning that their output voltage is influenced by the supply voltage. Some analog rangefinders (such as the SF/02) have their own internal voltage regulators so they are not ratiometric.

Values

Value

Meaning

0

No

1

Yes

RNGFND4_PWRRNG: Powersave range

This parameter sets the estimated terrain distance in meters above which the sensor will be put into a power saving mode (if available). A value of zero means power saving is not enabled

Range

Units

0 to 32767

meters

RNGFND4_GNDCLEAR: Distance (in cm) from the range finder to the ground

This parameter sets the expected range measurement(in cm) that the range finder should return when the vehicle is on the ground.

Increment

Range

Units

1

5 to 127

centimeters

RNGFND4_ADDR: Bus address of sensor

This sets the bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

RNGFND4_POS_X: X position offset

Note: This parameter is for advanced users

X position of the rangefinder in body frame. Positive X is forward of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND4_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the rangefinder in body frame. Positive Y is to the right of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND4_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the rangefinder in body frame. Positive Z is down from the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND4_ORIENT: Rangefinder orientation

Note: This parameter is for advanced users

Orientation of rangefinder

Values

Value

Meaning

0

Forward

1

Forward-Right

2

Right

3

Back-Right

4

Back

5

Back-Left

6

Left

7

Forward-Left

24

Up

25

Down

RNGFND4_WSP_MAVG: Moving Average Range

Note: This parameter is for advanced users

Sets the number of historic range results to use for calculating the current range result. When MAVG is greater than 1, the current range result will be the current measured value averaged with the N-1 previous results

Range

0 to 255

RNGFND4_WSP_MEDF: Moving Median Filter

Note: This parameter is for advanced users

Sets the window size for the real-time median filter. When MEDF is greater than 0 the median filter is active

Range

0 to 255

RNGFND4_WSP_FRQ: Frequency

Note: This parameter is for advanced users

Sets the repetition frequency of the ranging operation in Hertz. Upon entering the desired frequency the system will calculate the nearest frequency that it can handle according to the resolution of internal timers.

Range

0 to 10000

RNGFND4_WSP_AVG: Multi-pulse averages

Note: This parameter is for advanced users

Sets the number of pulses to be used in multi-pulse averaging mode. In this mode, a sequence of rapid fire ranges are taken and then averaged to improve the accuracy of the measurement

Range

0 to 255

RNGFND4_WSP_THR: Sensitivity threshold

Note: This parameter is for advanced users

Sets the system sensitivity. Larger values of THR represent higher sensitivity. The system may limit the maximum value of THR to prevent excessive false alarm rates based on settings made at the factory. Set to -1 for automatic threshold adjustments

Range

-1 to 255

RNGFND4_WSP_BAUD: Baud rate

Note: This parameter is for advanced users

Desired baud rate

Values

Value

Meaning

0

Low Speed

1

High Speed

RNGFND4_RECV_ID: RangeFinder CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

RNGFND4_SNR_MIN: RangeFinder Minimum signal strength

Note: This parameter is for advanced users

RangeFinder Minimum signal strength (SNR) to accept distance

Range

0 to 65535

RNGFND5_ Parameters

RNGFND5_TYPE: Rangefinder type

Type of connected rangefinder

Values

Value

Meaning

0

None

1

Analog

2

MaxbotixI2C

3

LidarLite-I2C

5

PWM

6

BBB-PRU

7

LightWareI2C

8

LightWareSerial

9

Bebop

10

MAVLink

11

USD1_Serial

12

LeddarOne

13

MaxbotixSerial

14

TeraRangerI2C

15

LidarLiteV3-I2C

16

VL53L0X or VL53L1X

17

NMEA

18

WASP-LRF

19

BenewakeTF02

20

Benewake-Serial

21

LidarLightV3HP

22

PWM

23

BlueRoboticsPing

24

DroneCAN

25

BenewakeTFminiPlus-I2C

26

LanbaoPSK-CM8JL65-CC5

27

BenewakeTF03

28

VL53L1X-ShortRange

29

LeddarVu8-Serial

30

HC-SR04

31

GYUS42v2

32

MSP

33

USD1_CAN

34

Benewake_CAN

35

TeraRangerSerial

36

Lua_Scripting

37

NoopLoop_TOFSense

38

NoopLoop_TOFSense_CAN

39

NRA24_CAN

40

NoopLoop_TOFSenseF_I2C

41

JRE_Serial

42

Ainstein_LR_D1

43

RDS02UF

100

SITL

RNGFND5_PIN: Rangefinder pin

Analog or PWM input pin that rangefinder is connected to. Analog RSSI or Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

-1

Not Used

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RNGFND5_SCALING: Rangefinder scaling

Scaling factor between rangefinder reading and distance. For the linear and inverted functions this is in meters per volt. For the hyperbolic function the units are meterVolts. For Maxbotix serial sonar this is unit conversion to meters.

Increment

Units

0.001

meters per volt

RNGFND5_OFFSET: rangefinder offset

Offset in volts for zero distance for analog rangefinders. Offset added to distance in centimeters for PWM lidars

Increment

Units

0.001

volt

RNGFND5_FUNCTION: Rangefinder function

Control over what function is used to calculate distance. For a linear function, the distance is (voltage-offset)*scaling. For a inverted function the distance is (offset-voltage)*scaling. For a hyperbolic function the distance is scaling/(voltage-offset). The functions return the distance in meters.

Values

Value

Meaning

0

Linear

1

Inverted

2

Hyperbolic

RNGFND5_MIN_CM: Rangefinder minimum distance

Minimum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND5_MAX_CM: Rangefinder maximum distance

Maximum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND5_STOP_PIN: Rangefinder stop pin

Digital pin that enables/disables rangefinder measurement for the pwm rangefinder. A value of -1 means no pin. If this is set, then the pin is set to 1 to enable the rangefinder and set to 0 to disable it. This is used to enable powersaving when out of range. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Not Used

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

111

PX4 FMU Relay1

112

PX4 FMU Relay2

113

PX4IO Relay1

114

PX4IO Relay2

115

PX4IO ACC1

116

PX4IO ACC2

RNGFND5_RMETRIC: Ratiometric

This parameter sets whether an analog rangefinder is ratiometric. Most analog rangefinders are ratiometric, meaning that their output voltage is influenced by the supply voltage. Some analog rangefinders (such as the SF/02) have their own internal voltage regulators so they are not ratiometric.

Values

Value

Meaning

0

No

1

Yes

RNGFND5_PWRRNG: Powersave range

This parameter sets the estimated terrain distance in meters above which the sensor will be put into a power saving mode (if available). A value of zero means power saving is not enabled

Range

Units

0 to 32767

meters

RNGFND5_GNDCLEAR: Distance (in cm) from the range finder to the ground

This parameter sets the expected range measurement(in cm) that the range finder should return when the vehicle is on the ground.

Increment

Range

Units

1

5 to 127

centimeters

RNGFND5_ADDR: Bus address of sensor

This sets the bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

RNGFND5_POS_X: X position offset

Note: This parameter is for advanced users

X position of the rangefinder in body frame. Positive X is forward of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND5_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the rangefinder in body frame. Positive Y is to the right of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND5_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the rangefinder in body frame. Positive Z is down from the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND5_ORIENT: Rangefinder orientation

Note: This parameter is for advanced users

Orientation of rangefinder

Values

Value

Meaning

0

Forward

1

Forward-Right

2

Right

3

Back-Right

4

Back

5

Back-Left

6

Left

7

Forward-Left

24

Up

25

Down

RNGFND5_WSP_MAVG: Moving Average Range

Note: This parameter is for advanced users

Sets the number of historic range results to use for calculating the current range result. When MAVG is greater than 1, the current range result will be the current measured value averaged with the N-1 previous results

Range

0 to 255

RNGFND5_WSP_MEDF: Moving Median Filter

Note: This parameter is for advanced users

Sets the window size for the real-time median filter. When MEDF is greater than 0 the median filter is active

Range

0 to 255

RNGFND5_WSP_FRQ: Frequency

Note: This parameter is for advanced users

Sets the repetition frequency of the ranging operation in Hertz. Upon entering the desired frequency the system will calculate the nearest frequency that it can handle according to the resolution of internal timers.

Range

0 to 10000

RNGFND5_WSP_AVG: Multi-pulse averages

Note: This parameter is for advanced users

Sets the number of pulses to be used in multi-pulse averaging mode. In this mode, a sequence of rapid fire ranges are taken and then averaged to improve the accuracy of the measurement

Range

0 to 255

RNGFND5_WSP_THR: Sensitivity threshold

Note: This parameter is for advanced users

Sets the system sensitivity. Larger values of THR represent higher sensitivity. The system may limit the maximum value of THR to prevent excessive false alarm rates based on settings made at the factory. Set to -1 for automatic threshold adjustments

Range

-1 to 255

RNGFND5_WSP_BAUD: Baud rate

Note: This parameter is for advanced users

Desired baud rate

Values

Value

Meaning

0

Low Speed

1

High Speed

RNGFND5_RECV_ID: RangeFinder CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

RNGFND5_SNR_MIN: RangeFinder Minimum signal strength

Note: This parameter is for advanced users

RangeFinder Minimum signal strength (SNR) to accept distance

Range

0 to 65535

RNGFND6_ Parameters

RNGFND6_TYPE: Rangefinder type

Type of connected rangefinder

Values

Value

Meaning

0

None

1

Analog

2

MaxbotixI2C

3

LidarLite-I2C

5

PWM

6

BBB-PRU

7

LightWareI2C

8

LightWareSerial

9

Bebop

10

MAVLink

11

USD1_Serial

12

LeddarOne

13

MaxbotixSerial

14

TeraRangerI2C

15

LidarLiteV3-I2C

16

VL53L0X or VL53L1X

17

NMEA

18

WASP-LRF

19

BenewakeTF02

20

Benewake-Serial

21

LidarLightV3HP

22

PWM

23

BlueRoboticsPing

24

DroneCAN

25

BenewakeTFminiPlus-I2C

26

LanbaoPSK-CM8JL65-CC5

27

BenewakeTF03

28

VL53L1X-ShortRange

29

LeddarVu8-Serial

30

HC-SR04

31

GYUS42v2

32

MSP

33

USD1_CAN

34

Benewake_CAN

35

TeraRangerSerial

36

Lua_Scripting

37

NoopLoop_TOFSense

38

NoopLoop_TOFSense_CAN

39

NRA24_CAN

40

NoopLoop_TOFSenseF_I2C

41

JRE_Serial

42

Ainstein_LR_D1

43

RDS02UF

100

SITL

RNGFND6_PIN: Rangefinder pin

Analog or PWM input pin that rangefinder is connected to. Analog RSSI or Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

-1

Not Used

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RNGFND6_SCALING: Rangefinder scaling

Scaling factor between rangefinder reading and distance. For the linear and inverted functions this is in meters per volt. For the hyperbolic function the units are meterVolts. For Maxbotix serial sonar this is unit conversion to meters.

Increment

Units

0.001

meters per volt

RNGFND6_OFFSET: rangefinder offset

Offset in volts for zero distance for analog rangefinders. Offset added to distance in centimeters for PWM lidars

Increment

Units

0.001

volt

RNGFND6_FUNCTION: Rangefinder function

Control over what function is used to calculate distance. For a linear function, the distance is (voltage-offset)*scaling. For a inverted function the distance is (offset-voltage)*scaling. For a hyperbolic function the distance is scaling/(voltage-offset). The functions return the distance in meters.

Values

Value

Meaning

0

Linear

1

Inverted

2

Hyperbolic

RNGFND6_MIN_CM: Rangefinder minimum distance

Minimum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND6_MAX_CM: Rangefinder maximum distance

Maximum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND6_STOP_PIN: Rangefinder stop pin

Digital pin that enables/disables rangefinder measurement for the pwm rangefinder. A value of -1 means no pin. If this is set, then the pin is set to 1 to enable the rangefinder and set to 0 to disable it. This is used to enable powersaving when out of range. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Not Used

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

111

PX4 FMU Relay1

112

PX4 FMU Relay2

113

PX4IO Relay1

114

PX4IO Relay2

115

PX4IO ACC1

116

PX4IO ACC2

RNGFND6_RMETRIC: Ratiometric

This parameter sets whether an analog rangefinder is ratiometric. Most analog rangefinders are ratiometric, meaning that their output voltage is influenced by the supply voltage. Some analog rangefinders (such as the SF/02) have their own internal voltage regulators so they are not ratiometric.

Values

Value

Meaning

0

No

1

Yes

RNGFND6_PWRRNG: Powersave range

This parameter sets the estimated terrain distance in meters above which the sensor will be put into a power saving mode (if available). A value of zero means power saving is not enabled

Range

Units

0 to 32767

meters

RNGFND6_GNDCLEAR: Distance (in cm) from the range finder to the ground

This parameter sets the expected range measurement(in cm) that the range finder should return when the vehicle is on the ground.

Increment

Range

Units

1

5 to 127

centimeters

RNGFND6_ADDR: Bus address of sensor

This sets the bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

RNGFND6_POS_X: X position offset

Note: This parameter is for advanced users

X position of the rangefinder in body frame. Positive X is forward of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND6_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the rangefinder in body frame. Positive Y is to the right of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND6_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the rangefinder in body frame. Positive Z is down from the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND6_ORIENT: Rangefinder orientation

Note: This parameter is for advanced users

Orientation of rangefinder

Values

Value

Meaning

0

Forward

1

Forward-Right

2

Right

3

Back-Right

4

Back

5

Back-Left

6

Left

7

Forward-Left

24

Up

25

Down

RNGFND6_WSP_MAVG: Moving Average Range

Note: This parameter is for advanced users

Sets the number of historic range results to use for calculating the current range result. When MAVG is greater than 1, the current range result will be the current measured value averaged with the N-1 previous results

Range

0 to 255

RNGFND6_WSP_MEDF: Moving Median Filter

Note: This parameter is for advanced users

Sets the window size for the real-time median filter. When MEDF is greater than 0 the median filter is active

Range

0 to 255

RNGFND6_WSP_FRQ: Frequency

Note: This parameter is for advanced users

Sets the repetition frequency of the ranging operation in Hertz. Upon entering the desired frequency the system will calculate the nearest frequency that it can handle according to the resolution of internal timers.

Range

0 to 10000

RNGFND6_WSP_AVG: Multi-pulse averages

Note: This parameter is for advanced users

Sets the number of pulses to be used in multi-pulse averaging mode. In this mode, a sequence of rapid fire ranges are taken and then averaged to improve the accuracy of the measurement

Range

0 to 255

RNGFND6_WSP_THR: Sensitivity threshold

Note: This parameter is for advanced users

Sets the system sensitivity. Larger values of THR represent higher sensitivity. The system may limit the maximum value of THR to prevent excessive false alarm rates based on settings made at the factory. Set to -1 for automatic threshold adjustments

Range

-1 to 255

RNGFND6_WSP_BAUD: Baud rate

Note: This parameter is for advanced users

Desired baud rate

Values

Value

Meaning

0

Low Speed

1

High Speed

RNGFND6_RECV_ID: RangeFinder CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

RNGFND6_SNR_MIN: RangeFinder Minimum signal strength

Note: This parameter is for advanced users

RangeFinder Minimum signal strength (SNR) to accept distance

Range

0 to 65535

RNGFND7_ Parameters

RNGFND7_TYPE: Rangefinder type

Type of connected rangefinder

Values

Value

Meaning

0

None

1

Analog

2

MaxbotixI2C

3

LidarLite-I2C

5

PWM

6

BBB-PRU

7

LightWareI2C

8

LightWareSerial

9

Bebop

10

MAVLink

11

USD1_Serial

12

LeddarOne

13

MaxbotixSerial

14

TeraRangerI2C

15

LidarLiteV3-I2C

16

VL53L0X or VL53L1X

17

NMEA

18

WASP-LRF

19

BenewakeTF02

20

Benewake-Serial

21

LidarLightV3HP

22

PWM

23

BlueRoboticsPing

24

DroneCAN

25

BenewakeTFminiPlus-I2C

26

LanbaoPSK-CM8JL65-CC5

27

BenewakeTF03

28

VL53L1X-ShortRange

29

LeddarVu8-Serial

30

HC-SR04

31

GYUS42v2

32

MSP

33

USD1_CAN

34

Benewake_CAN

35

TeraRangerSerial

36

Lua_Scripting

37

NoopLoop_TOFSense

38

NoopLoop_TOFSense_CAN

39

NRA24_CAN

40

NoopLoop_TOFSenseF_I2C

41

JRE_Serial

42

Ainstein_LR_D1

43

RDS02UF

100

SITL

RNGFND7_PIN: Rangefinder pin

Analog or PWM input pin that rangefinder is connected to. Analog RSSI or Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

-1

Not Used

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RNGFND7_SCALING: Rangefinder scaling

Scaling factor between rangefinder reading and distance. For the linear and inverted functions this is in meters per volt. For the hyperbolic function the units are meterVolts. For Maxbotix serial sonar this is unit conversion to meters.

Increment

Units

0.001

meters per volt

RNGFND7_OFFSET: rangefinder offset

Offset in volts for zero distance for analog rangefinders. Offset added to distance in centimeters for PWM lidars

Increment

Units

0.001

volt

RNGFND7_FUNCTION: Rangefinder function

Control over what function is used to calculate distance. For a linear function, the distance is (voltage-offset)*scaling. For a inverted function the distance is (offset-voltage)*scaling. For a hyperbolic function the distance is scaling/(voltage-offset). The functions return the distance in meters.

Values

Value

Meaning

0

Linear

1

Inverted

2

Hyperbolic

RNGFND7_MIN_CM: Rangefinder minimum distance

Minimum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND7_MAX_CM: Rangefinder maximum distance

Maximum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND7_STOP_PIN: Rangefinder stop pin

Digital pin that enables/disables rangefinder measurement for the pwm rangefinder. A value of -1 means no pin. If this is set, then the pin is set to 1 to enable the rangefinder and set to 0 to disable it. This is used to enable powersaving when out of range. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Not Used

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

111

PX4 FMU Relay1

112

PX4 FMU Relay2

113

PX4IO Relay1

114

PX4IO Relay2

115

PX4IO ACC1

116

PX4IO ACC2

RNGFND7_RMETRIC: Ratiometric

This parameter sets whether an analog rangefinder is ratiometric. Most analog rangefinders are ratiometric, meaning that their output voltage is influenced by the supply voltage. Some analog rangefinders (such as the SF/02) have their own internal voltage regulators so they are not ratiometric.

Values

Value

Meaning

0

No

1

Yes

RNGFND7_PWRRNG: Powersave range

This parameter sets the estimated terrain distance in meters above which the sensor will be put into a power saving mode (if available). A value of zero means power saving is not enabled

Range

Units

0 to 32767

meters

RNGFND7_GNDCLEAR: Distance (in cm) from the range finder to the ground

This parameter sets the expected range measurement(in cm) that the range finder should return when the vehicle is on the ground.

Increment

Range

Units

1

5 to 127

centimeters

RNGFND7_ADDR: Bus address of sensor

This sets the bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

RNGFND7_POS_X: X position offset

Note: This parameter is for advanced users

X position of the rangefinder in body frame. Positive X is forward of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND7_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the rangefinder in body frame. Positive Y is to the right of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND7_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the rangefinder in body frame. Positive Z is down from the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND7_ORIENT: Rangefinder orientation

Note: This parameter is for advanced users

Orientation of rangefinder

Values

Value

Meaning

0

Forward

1

Forward-Right

2

Right

3

Back-Right

4

Back

5

Back-Left

6

Left

7

Forward-Left

24

Up

25

Down

RNGFND7_WSP_MAVG: Moving Average Range

Note: This parameter is for advanced users

Sets the number of historic range results to use for calculating the current range result. When MAVG is greater than 1, the current range result will be the current measured value averaged with the N-1 previous results

Range

0 to 255

RNGFND7_WSP_MEDF: Moving Median Filter

Note: This parameter is for advanced users

Sets the window size for the real-time median filter. When MEDF is greater than 0 the median filter is active

Range

0 to 255

RNGFND7_WSP_FRQ: Frequency

Note: This parameter is for advanced users

Sets the repetition frequency of the ranging operation in Hertz. Upon entering the desired frequency the system will calculate the nearest frequency that it can handle according to the resolution of internal timers.

Range

0 to 10000

RNGFND7_WSP_AVG: Multi-pulse averages

Note: This parameter is for advanced users

Sets the number of pulses to be used in multi-pulse averaging mode. In this mode, a sequence of rapid fire ranges are taken and then averaged to improve the accuracy of the measurement

Range

0 to 255

RNGFND7_WSP_THR: Sensitivity threshold

Note: This parameter is for advanced users

Sets the system sensitivity. Larger values of THR represent higher sensitivity. The system may limit the maximum value of THR to prevent excessive false alarm rates based on settings made at the factory. Set to -1 for automatic threshold adjustments

Range

-1 to 255

RNGFND7_WSP_BAUD: Baud rate

Note: This parameter is for advanced users

Desired baud rate

Values

Value

Meaning

0

Low Speed

1

High Speed

RNGFND7_RECV_ID: RangeFinder CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

RNGFND7_SNR_MIN: RangeFinder Minimum signal strength

Note: This parameter is for advanced users

RangeFinder Minimum signal strength (SNR) to accept distance

Range

0 to 65535

RNGFND8_ Parameters

RNGFND8_TYPE: Rangefinder type

Type of connected rangefinder

Values

Value

Meaning

0

None

1

Analog

2

MaxbotixI2C

3

LidarLite-I2C

5

PWM

6

BBB-PRU

7

LightWareI2C

8

LightWareSerial

9

Bebop

10

MAVLink

11

USD1_Serial

12

LeddarOne

13

MaxbotixSerial

14

TeraRangerI2C

15

LidarLiteV3-I2C

16

VL53L0X or VL53L1X

17

NMEA

18

WASP-LRF

19

BenewakeTF02

20

Benewake-Serial

21

LidarLightV3HP

22

PWM

23

BlueRoboticsPing

24

DroneCAN

25

BenewakeTFminiPlus-I2C

26

LanbaoPSK-CM8JL65-CC5

27

BenewakeTF03

28

VL53L1X-ShortRange

29

LeddarVu8-Serial

30

HC-SR04

31

GYUS42v2

32

MSP

33

USD1_CAN

34

Benewake_CAN

35

TeraRangerSerial

36

Lua_Scripting

37

NoopLoop_TOFSense

38

NoopLoop_TOFSense_CAN

39

NRA24_CAN

40

NoopLoop_TOFSenseF_I2C

41

JRE_Serial

42

Ainstein_LR_D1

43

RDS02UF

100

SITL

RNGFND8_PIN: Rangefinder pin

Analog or PWM input pin that rangefinder is connected to. Analog RSSI or Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

-1

Not Used

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RNGFND8_SCALING: Rangefinder scaling

Scaling factor between rangefinder reading and distance. For the linear and inverted functions this is in meters per volt. For the hyperbolic function the units are meterVolts. For Maxbotix serial sonar this is unit conversion to meters.

Increment

Units

0.001

meters per volt

RNGFND8_OFFSET: rangefinder offset

Offset in volts for zero distance for analog rangefinders. Offset added to distance in centimeters for PWM lidars

Increment

Units

0.001

volt

RNGFND8_FUNCTION: Rangefinder function

Control over what function is used to calculate distance. For a linear function, the distance is (voltage-offset)*scaling. For a inverted function the distance is (offset-voltage)*scaling. For a hyperbolic function the distance is scaling/(voltage-offset). The functions return the distance in meters.

Values

Value

Meaning

0

Linear

1

Inverted

2

Hyperbolic

RNGFND8_MIN_CM: Rangefinder minimum distance

Minimum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND8_MAX_CM: Rangefinder maximum distance

Maximum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND8_STOP_PIN: Rangefinder stop pin

Digital pin that enables/disables rangefinder measurement for the pwm rangefinder. A value of -1 means no pin. If this is set, then the pin is set to 1 to enable the rangefinder and set to 0 to disable it. This is used to enable powersaving when out of range. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Not Used

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

111

PX4 FMU Relay1

112

PX4 FMU Relay2

113

PX4IO Relay1

114

PX4IO Relay2

115

PX4IO ACC1

116

PX4IO ACC2

RNGFND8_RMETRIC: Ratiometric

This parameter sets whether an analog rangefinder is ratiometric. Most analog rangefinders are ratiometric, meaning that their output voltage is influenced by the supply voltage. Some analog rangefinders (such as the SF/02) have their own internal voltage regulators so they are not ratiometric.

Values

Value

Meaning

0

No

1

Yes

RNGFND8_PWRRNG: Powersave range

This parameter sets the estimated terrain distance in meters above which the sensor will be put into a power saving mode (if available). A value of zero means power saving is not enabled

Range

Units

0 to 32767

meters

RNGFND8_GNDCLEAR: Distance (in cm) from the range finder to the ground

This parameter sets the expected range measurement(in cm) that the range finder should return when the vehicle is on the ground.

Increment

Range

Units

1

5 to 127

centimeters

RNGFND8_ADDR: Bus address of sensor

This sets the bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

RNGFND8_POS_X: X position offset

Note: This parameter is for advanced users

X position of the rangefinder in body frame. Positive X is forward of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND8_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the rangefinder in body frame. Positive Y is to the right of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND8_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the rangefinder in body frame. Positive Z is down from the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND8_ORIENT: Rangefinder orientation

Note: This parameter is for advanced users

Orientation of rangefinder

Values

Value

Meaning

0

Forward

1

Forward-Right

2

Right

3

Back-Right

4

Back

5

Back-Left

6

Left

7

Forward-Left

24

Up

25

Down

RNGFND8_WSP_MAVG: Moving Average Range

Note: This parameter is for advanced users

Sets the number of historic range results to use for calculating the current range result. When MAVG is greater than 1, the current range result will be the current measured value averaged with the N-1 previous results

Range

0 to 255

RNGFND8_WSP_MEDF: Moving Median Filter

Note: This parameter is for advanced users

Sets the window size for the real-time median filter. When MEDF is greater than 0 the median filter is active

Range

0 to 255

RNGFND8_WSP_FRQ: Frequency

Note: This parameter is for advanced users

Sets the repetition frequency of the ranging operation in Hertz. Upon entering the desired frequency the system will calculate the nearest frequency that it can handle according to the resolution of internal timers.

Range

0 to 10000

RNGFND8_WSP_AVG: Multi-pulse averages

Note: This parameter is for advanced users

Sets the number of pulses to be used in multi-pulse averaging mode. In this mode, a sequence of rapid fire ranges are taken and then averaged to improve the accuracy of the measurement

Range

0 to 255

RNGFND8_WSP_THR: Sensitivity threshold

Note: This parameter is for advanced users

Sets the system sensitivity. Larger values of THR represent higher sensitivity. The system may limit the maximum value of THR to prevent excessive false alarm rates based on settings made at the factory. Set to -1 for automatic threshold adjustments

Range

-1 to 255

RNGFND8_WSP_BAUD: Baud rate

Note: This parameter is for advanced users

Desired baud rate

Values

Value

Meaning

0

Low Speed

1

High Speed

RNGFND8_RECV_ID: RangeFinder CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

RNGFND8_SNR_MIN: RangeFinder Minimum signal strength

Note: This parameter is for advanced users

RangeFinder Minimum signal strength (SNR) to accept distance

Range

0 to 65535

RNGFND9_ Parameters

RNGFND9_TYPE: Rangefinder type

Type of connected rangefinder

Values

Value

Meaning

0

None

1

Analog

2

MaxbotixI2C

3

LidarLite-I2C

5

PWM

6

BBB-PRU

7

LightWareI2C

8

LightWareSerial

9

Bebop

10

MAVLink

11

USD1_Serial

12

LeddarOne

13

MaxbotixSerial

14

TeraRangerI2C

15

LidarLiteV3-I2C

16

VL53L0X or VL53L1X

17

NMEA

18

WASP-LRF

19

BenewakeTF02

20

Benewake-Serial

21

LidarLightV3HP

22

PWM

23

BlueRoboticsPing

24

DroneCAN

25

BenewakeTFminiPlus-I2C

26

LanbaoPSK-CM8JL65-CC5

27

BenewakeTF03

28

VL53L1X-ShortRange

29

LeddarVu8-Serial

30

HC-SR04

31

GYUS42v2

32

MSP

33

USD1_CAN

34

Benewake_CAN

35

TeraRangerSerial

36

Lua_Scripting

37

NoopLoop_TOFSense

38

NoopLoop_TOFSense_CAN

39

NRA24_CAN

40

NoopLoop_TOFSenseF_I2C

41

JRE_Serial

42

Ainstein_LR_D1

43

RDS02UF

100

SITL

RNGFND9_PIN: Rangefinder pin

Analog or PWM input pin that rangefinder is connected to. Analog RSSI or Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

-1

Not Used

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RNGFND9_SCALING: Rangefinder scaling

Scaling factor between rangefinder reading and distance. For the linear and inverted functions this is in meters per volt. For the hyperbolic function the units are meterVolts. For Maxbotix serial sonar this is unit conversion to meters.

Increment

Units

0.001

meters per volt

RNGFND9_OFFSET: rangefinder offset

Offset in volts for zero distance for analog rangefinders. Offset added to distance in centimeters for PWM lidars

Increment

Units

0.001

volt

RNGFND9_FUNCTION: Rangefinder function

Control over what function is used to calculate distance. For a linear function, the distance is (voltage-offset)*scaling. For a inverted function the distance is (offset-voltage)*scaling. For a hyperbolic function the distance is scaling/(voltage-offset). The functions return the distance in meters.

Values

Value

Meaning

0

Linear

1

Inverted

2

Hyperbolic

RNGFND9_MIN_CM: Rangefinder minimum distance

Minimum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND9_MAX_CM: Rangefinder maximum distance

Maximum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFND9_STOP_PIN: Rangefinder stop pin

Digital pin that enables/disables rangefinder measurement for the pwm rangefinder. A value of -1 means no pin. If this is set, then the pin is set to 1 to enable the rangefinder and set to 0 to disable it. This is used to enable powersaving when out of range. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Not Used

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

111

PX4 FMU Relay1

112

PX4 FMU Relay2

113

PX4IO Relay1

114

PX4IO Relay2

115

PX4IO ACC1

116

PX4IO ACC2

RNGFND9_RMETRIC: Ratiometric

This parameter sets whether an analog rangefinder is ratiometric. Most analog rangefinders are ratiometric, meaning that their output voltage is influenced by the supply voltage. Some analog rangefinders (such as the SF/02) have their own internal voltage regulators so they are not ratiometric.

Values

Value

Meaning

0

No

1

Yes

RNGFND9_PWRRNG: Powersave range

This parameter sets the estimated terrain distance in meters above which the sensor will be put into a power saving mode (if available). A value of zero means power saving is not enabled

Range

Units

0 to 32767

meters

RNGFND9_GNDCLEAR: Distance (in cm) from the range finder to the ground

This parameter sets the expected range measurement(in cm) that the range finder should return when the vehicle is on the ground.

Increment

Range

Units

1

5 to 127

centimeters

RNGFND9_ADDR: Bus address of sensor

This sets the bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

RNGFND9_POS_X: X position offset

Note: This parameter is for advanced users

X position of the rangefinder in body frame. Positive X is forward of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND9_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the rangefinder in body frame. Positive Y is to the right of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND9_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the rangefinder in body frame. Positive Z is down from the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFND9_ORIENT: Rangefinder orientation

Note: This parameter is for advanced users

Orientation of rangefinder

Values

Value

Meaning

0

Forward

1

Forward-Right

2

Right

3

Back-Right

4

Back

5

Back-Left

6

Left

7

Forward-Left

24

Up

25

Down

RNGFND9_WSP_MAVG: Moving Average Range

Note: This parameter is for advanced users

Sets the number of historic range results to use for calculating the current range result. When MAVG is greater than 1, the current range result will be the current measured value averaged with the N-1 previous results

Range

0 to 255

RNGFND9_WSP_MEDF: Moving Median Filter

Note: This parameter is for advanced users

Sets the window size for the real-time median filter. When MEDF is greater than 0 the median filter is active

Range

0 to 255

RNGFND9_WSP_FRQ: Frequency

Note: This parameter is for advanced users

Sets the repetition frequency of the ranging operation in Hertz. Upon entering the desired frequency the system will calculate the nearest frequency that it can handle according to the resolution of internal timers.

Range

0 to 10000

RNGFND9_WSP_AVG: Multi-pulse averages

Note: This parameter is for advanced users

Sets the number of pulses to be used in multi-pulse averaging mode. In this mode, a sequence of rapid fire ranges are taken and then averaged to improve the accuracy of the measurement

Range

0 to 255

RNGFND9_WSP_THR: Sensitivity threshold

Note: This parameter is for advanced users

Sets the system sensitivity. Larger values of THR represent higher sensitivity. The system may limit the maximum value of THR to prevent excessive false alarm rates based on settings made at the factory. Set to -1 for automatic threshold adjustments

Range

-1 to 255

RNGFND9_WSP_BAUD: Baud rate

Note: This parameter is for advanced users

Desired baud rate

Values

Value

Meaning

0

Low Speed

1

High Speed

RNGFND9_RECV_ID: RangeFinder CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

RNGFND9_SNR_MIN: RangeFinder Minimum signal strength

Note: This parameter is for advanced users

RangeFinder Minimum signal strength (SNR) to accept distance

Range

0 to 65535

RNGFNDA_ Parameters

RNGFNDA_TYPE: Rangefinder type

Type of connected rangefinder

Values

Value

Meaning

0

None

1

Analog

2

MaxbotixI2C

3

LidarLite-I2C

5

PWM

6

BBB-PRU

7

LightWareI2C

8

LightWareSerial

9

Bebop

10

MAVLink

11

USD1_Serial

12

LeddarOne

13

MaxbotixSerial

14

TeraRangerI2C

15

LidarLiteV3-I2C

16

VL53L0X or VL53L1X

17

NMEA

18

WASP-LRF

19

BenewakeTF02

20

Benewake-Serial

21

LidarLightV3HP

22

PWM

23

BlueRoboticsPing

24

DroneCAN

25

BenewakeTFminiPlus-I2C

26

LanbaoPSK-CM8JL65-CC5

27

BenewakeTF03

28

VL53L1X-ShortRange

29

LeddarVu8-Serial

30

HC-SR04

31

GYUS42v2

32

MSP

33

USD1_CAN

34

Benewake_CAN

35

TeraRangerSerial

36

Lua_Scripting

37

NoopLoop_TOFSense

38

NoopLoop_TOFSense_CAN

39

NRA24_CAN

40

NoopLoop_TOFSenseF_I2C

41

JRE_Serial

42

Ainstein_LR_D1

43

RDS02UF

100

SITL

RNGFNDA_PIN: Rangefinder pin

Analog or PWM input pin that rangefinder is connected to. Analog RSSI or Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

-1

Not Used

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RNGFNDA_SCALING: Rangefinder scaling

Scaling factor between rangefinder reading and distance. For the linear and inverted functions this is in meters per volt. For the hyperbolic function the units are meterVolts. For Maxbotix serial sonar this is unit conversion to meters.

Increment

Units

0.001

meters per volt

RNGFNDA_OFFSET: rangefinder offset

Offset in volts for zero distance for analog rangefinders. Offset added to distance in centimeters for PWM lidars

Increment

Units

0.001

volt

RNGFNDA_FUNCTION: Rangefinder function

Control over what function is used to calculate distance. For a linear function, the distance is (voltage-offset)*scaling. For a inverted function the distance is (offset-voltage)*scaling. For a hyperbolic function the distance is scaling/(voltage-offset). The functions return the distance in meters.

Values

Value

Meaning

0

Linear

1

Inverted

2

Hyperbolic

RNGFNDA_MIN_CM: Rangefinder minimum distance

Minimum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFNDA_MAX_CM: Rangefinder maximum distance

Maximum distance in centimeters that rangefinder can reliably read

Increment

Units

1

centimeters

RNGFNDA_STOP_PIN: Rangefinder stop pin

Digital pin that enables/disables rangefinder measurement for the pwm rangefinder. A value of -1 means no pin. If this is set, then the pin is set to 1 to enable the rangefinder and set to 0 to disable it. This is used to enable powersaving when out of range. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Not Used

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

111

PX4 FMU Relay1

112

PX4 FMU Relay2

113

PX4IO Relay1

114

PX4IO Relay2

115

PX4IO ACC1

116

PX4IO ACC2

RNGFNDA_RMETRIC: Ratiometric

This parameter sets whether an analog rangefinder is ratiometric. Most analog rangefinders are ratiometric, meaning that their output voltage is influenced by the supply voltage. Some analog rangefinders (such as the SF/02) have their own internal voltage regulators so they are not ratiometric.

Values

Value

Meaning

0

No

1

Yes

RNGFNDA_PWRRNG: Powersave range

This parameter sets the estimated terrain distance in meters above which the sensor will be put into a power saving mode (if available). A value of zero means power saving is not enabled

Range

Units

0 to 32767

meters

RNGFNDA_GNDCLEAR: Distance (in cm) from the range finder to the ground

This parameter sets the expected range measurement(in cm) that the range finder should return when the vehicle is on the ground.

Increment

Range

Units

1

5 to 127

centimeters

RNGFNDA_ADDR: Bus address of sensor

This sets the bus address of the sensor, where applicable. Used for the I2C and DroneCAN sensors to allow for multiple sensors on different addresses.

Increment

Range

1

0 to 127

RNGFNDA_POS_X: X position offset

Note: This parameter is for advanced users

X position of the rangefinder in body frame. Positive X is forward of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFNDA_POS_Y: Y position offset

Note: This parameter is for advanced users

Y position of the rangefinder in body frame. Positive Y is to the right of the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFNDA_POS_Z: Z position offset

Note: This parameter is for advanced users

Z position of the rangefinder in body frame. Positive Z is down from the origin. Use the zero range datum point if supplied.

Increment

Range

Units

0.01

-5 to 5

meters

RNGFNDA_ORIENT: Rangefinder orientation

Note: This parameter is for advanced users

Orientation of rangefinder

Values

Value

Meaning

0

Forward

1

Forward-Right

2

Right

3

Back-Right

4

Back

5

Back-Left

6

Left

7

Forward-Left

24

Up

25

Down

RNGFNDA_WSP_MAVG: Moving Average Range

Note: This parameter is for advanced users

Sets the number of historic range results to use for calculating the current range result. When MAVG is greater than 1, the current range result will be the current measured value averaged with the N-1 previous results

Range

0 to 255

RNGFNDA_WSP_MEDF: Moving Median Filter

Note: This parameter is for advanced users

Sets the window size for the real-time median filter. When MEDF is greater than 0 the median filter is active

Range

0 to 255

RNGFNDA_WSP_FRQ: Frequency

Note: This parameter is for advanced users

Sets the repetition frequency of the ranging operation in Hertz. Upon entering the desired frequency the system will calculate the nearest frequency that it can handle according to the resolution of internal timers.

Range

0 to 10000

RNGFNDA_WSP_AVG: Multi-pulse averages

Note: This parameter is for advanced users

Sets the number of pulses to be used in multi-pulse averaging mode. In this mode, a sequence of rapid fire ranges are taken and then averaged to improve the accuracy of the measurement

Range

0 to 255

RNGFNDA_WSP_THR: Sensitivity threshold

Note: This parameter is for advanced users

Sets the system sensitivity. Larger values of THR represent higher sensitivity. The system may limit the maximum value of THR to prevent excessive false alarm rates based on settings made at the factory. Set to -1 for automatic threshold adjustments

Range

-1 to 255

RNGFNDA_WSP_BAUD: Baud rate

Note: This parameter is for advanced users

Desired baud rate

Values

Value

Meaning

0

Low Speed

1

High Speed

RNGFNDA_RECV_ID: RangeFinder CAN receive ID

Note: This parameter is for advanced users

The receive ID of the CAN frames. A value of zero means all IDs are accepted.

Range

0 to 65535

RNGFNDA_SNR_MIN: RangeFinder Minimum signal strength

Note: This parameter is for advanced users

RangeFinder Minimum signal strength (SNR) to accept distance

Range

0 to 65535

RPM1_ Parameters

RPM1_TYPE: RPM type

What type of RPM sensor is connected

Values

Value

Meaning

0

None

1

Not Used

2

GPIO

3

EFI

4

Harmonic Notch

5

ESC Telemetry Motors Bitmask

6

Generator

7

DroneCAN

RPM1_SCALING: RPM scaling

Scaling factor between sensor reading and RPM.

Increment

0.001

RPM1_MAX: Maximum RPM

Maximum RPM to report. Only used on type = GPIO.

Increment

1

RPM1_MIN: Minimum RPM

Minimum RPM to report. Only used on type = GPIO.

Increment

1

RPM1_MIN_QUAL: Minimum Quality

Note: This parameter is for advanced users

Minimum data quality to be used

Increment

0.1

RPM1_PIN: Input pin number

Which digital GPIO pin to use. Only used on type = GPIO. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

RPM1_ESC_MASK: Bitmask of ESC telemetry channels to average

Note: This parameter is for advanced users

Mask of channels which support ESC rpm telemetry. RPM telemetry of the selected channels will be averaged

Bitmask

Bit

Meaning

0

Channel1

1

Channel2

2

Channel3

3

Channel4

4

Channel5

5

Channel6

6

Channel7

7

Channel8

8

Channel9

9

Channel10

10

Channel11

11

Channel12

12

Channel13

13

Channel14

14

Channel15

15

Channel16

RPM1_ESC_INDEX: ESC Telemetry Index to write RPM to

Note: This parameter is for advanced users

ESC Telemetry Index to write RPM to. Use 0 to disable.

Increment

Range

1

0 to 10

RPM1_DC_ID: DroneCAN Sensor ID

Note: This parameter is for advanced users

DroneCAN sensor ID to assign to this backend

Increment

Range

1

-1 to 10

RPM2_ Parameters

RPM2_TYPE: RPM type

What type of RPM sensor is connected

Values

Value

Meaning

0

None

1

Not Used

2

GPIO

3

EFI

4

Harmonic Notch

5

ESC Telemetry Motors Bitmask

6

Generator

7

DroneCAN

RPM2_SCALING: RPM scaling

Scaling factor between sensor reading and RPM.

Increment

0.001

RPM2_MAX: Maximum RPM

Maximum RPM to report. Only used on type = GPIO.

Increment

1

RPM2_MIN: Minimum RPM

Minimum RPM to report. Only used on type = GPIO.

Increment

1

RPM2_MIN_QUAL: Minimum Quality

Note: This parameter is for advanced users

Minimum data quality to be used

Increment

0.1

RPM2_PIN: Input pin number

Which digital GPIO pin to use. Only used on type = GPIO. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

RPM2_ESC_MASK: Bitmask of ESC telemetry channels to average

Note: This parameter is for advanced users

Mask of channels which support ESC rpm telemetry. RPM telemetry of the selected channels will be averaged

Bitmask

Bit

Meaning

0

Channel1

1

Channel2

2

Channel3

3

Channel4

4

Channel5

5

Channel6

6

Channel7

7

Channel8

8

Channel9

9

Channel10

10

Channel11

11

Channel12

12

Channel13

13

Channel14

14

Channel15

15

Channel16

RPM2_ESC_INDEX: ESC Telemetry Index to write RPM to

Note: This parameter is for advanced users

ESC Telemetry Index to write RPM to. Use 0 to disable.

Increment

Range

1

0 to 10

RPM2_DC_ID: DroneCAN Sensor ID

Note: This parameter is for advanced users

DroneCAN sensor ID to assign to this backend

Increment

Range

1

-1 to 10

RPM3_ Parameters

RPM3_TYPE: RPM type

What type of RPM sensor is connected

Values

Value

Meaning

0

None

1

Not Used

2

GPIO

3

EFI

4

Harmonic Notch

5

ESC Telemetry Motors Bitmask

6

Generator

7

DroneCAN

RPM3_SCALING: RPM scaling

Scaling factor between sensor reading and RPM.

Increment

0.001

RPM3_MAX: Maximum RPM

Maximum RPM to report. Only used on type = GPIO.

Increment

1

RPM3_MIN: Minimum RPM

Minimum RPM to report. Only used on type = GPIO.

Increment

1

RPM3_MIN_QUAL: Minimum Quality

Note: This parameter is for advanced users

Minimum data quality to be used

Increment

0.1

RPM3_PIN: Input pin number

Which digital GPIO pin to use. Only used on type = GPIO. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

RPM3_ESC_MASK: Bitmask of ESC telemetry channels to average

Note: This parameter is for advanced users

Mask of channels which support ESC rpm telemetry. RPM telemetry of the selected channels will be averaged

Bitmask

Bit

Meaning

0

Channel1

1

Channel2

2

Channel3

3

Channel4

4

Channel5

5

Channel6

6

Channel7

7

Channel8

8

Channel9

9

Channel10

10

Channel11

11

Channel12

12

Channel13

13

Channel14

14

Channel15

15

Channel16

RPM3_ESC_INDEX: ESC Telemetry Index to write RPM to

Note: This parameter is for advanced users

ESC Telemetry Index to write RPM to. Use 0 to disable.

Increment

Range

1

0 to 10

RPM3_DC_ID: DroneCAN Sensor ID

Note: This parameter is for advanced users

DroneCAN sensor ID to assign to this backend

Increment

Range

1

-1 to 10

RPM4_ Parameters

RPM4_TYPE: RPM type

What type of RPM sensor is connected

Values

Value

Meaning

0

None

1

Not Used

2

GPIO

3

EFI

4

Harmonic Notch

5

ESC Telemetry Motors Bitmask

6

Generator

7

DroneCAN

RPM4_SCALING: RPM scaling

Scaling factor between sensor reading and RPM.

Increment

0.001

RPM4_MAX: Maximum RPM

Maximum RPM to report. Only used on type = GPIO.

Increment

1

RPM4_MIN: Minimum RPM

Minimum RPM to report. Only used on type = GPIO.

Increment

1

RPM4_MIN_QUAL: Minimum Quality

Note: This parameter is for advanced users

Minimum data quality to be used

Increment

0.1

RPM4_PIN: Input pin number

Which digital GPIO pin to use. Only used on type = GPIO. Some common values are given, but see the Wiki's "GPIOs" page for how to determine the pin number for a given autopilot.

Values

Value

Meaning

-1

Disabled

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

RPM4_ESC_MASK: Bitmask of ESC telemetry channels to average

Note: This parameter is for advanced users

Mask of channels which support ESC rpm telemetry. RPM telemetry of the selected channels will be averaged

Bitmask

Bit

Meaning

0

Channel1

1

Channel2

2

Channel3

3

Channel4

4

Channel5

5

Channel6

6

Channel7

7

Channel8

8

Channel9

9

Channel10

10

Channel11

11

Channel12

12

Channel13

13

Channel14

14

Channel15

15

Channel16

RPM4_ESC_INDEX: ESC Telemetry Index to write RPM to

Note: This parameter is for advanced users

ESC Telemetry Index to write RPM to. Use 0 to disable.

Increment

Range

1

0 to 10

RPM4_DC_ID: DroneCAN Sensor ID

Note: This parameter is for advanced users

DroneCAN sensor ID to assign to this backend

Increment

Range

1

-1 to 10

RSSI_ Parameters

RSSI_TYPE: RSSI Type

Radio Receiver RSSI type. If your radio receiver supports RSSI of some kind, set it here, then set its associated RSSI_XXXXX parameters, if any.

Values

Value

Meaning

0

Disabled

1

AnalogPin

2

RCChannelPwmValue

3

ReceiverProtocol

4

PWMInputPin

5

TelemetryRadioRSSI

RSSI_ANA_PIN: Receiver RSSI sensing pin

Pin used to read the RSSI voltage or PWM value. Analog Airspeed ports can be used for Analog inputs (some autopilots provide others also), Non-IOMCU Servo/MotorOutputs can be used for PWM input when configured as "GPIOs". Values for some autopilots are given as examples. Search wiki for "Analog pins" for analog pin or "GPIOs", if PWM input type, to determine pin number.

Values

Value

Meaning

8

V5 Nano

11

Pixracer

13

Pixhawk ADC4

14

Pixhawk ADC3

15

Pixhawk ADC6/Pixhawk2 ADC

50

AUX1

51

AUX2

52

AUX3

53

AUX4

54

AUX5

55

AUX6

103

Pixhawk SBUS

RSSI_PIN_LOW: RSSI pin's lowest voltage

RSSI pin's voltage received on the RSSI_ANA_PIN when the signal strength is the weakest. Some radio receivers put out inverted values so this value may be higher than RSSI_PIN_HIGH. When using pin 103, the maximum value of the parameter is 3.3V.

Increment

Range

Units

0.01

0 to 5.0

volt

RSSI_PIN_HIGH: RSSI pin's highest voltage

RSSI pin's voltage received on the RSSI_ANA_PIN when the signal strength is the strongest. Some radio receivers put out inverted values so this value may be lower than RSSI_PIN_LOW. When using pin 103, the maximum value of the parameter is 3.3V.

Increment

Range

Units

0.01

0 to 5.0

volt

RSSI_CHANNEL: Receiver RSSI channel number

The channel number where RSSI will be output by the radio receiver (5 and above).

Range

0 to 16

RSSI_CHAN_LOW: RSSI PWM low value

PWM value that the radio receiver will put on the RSSI_CHANNEL or RSSI_ANA_PIN when the signal strength is the weakest. Some radio receivers output inverted values so this value may be lower than RSSI_CHAN_HIGH

Range

Units

0 to 2000

PWM in microseconds

RSSI_CHAN_HIGH: Receiver RSSI PWM high value

PWM value that the radio receiver will put on the RSSI_CHANNEL or RSSI_ANA_PIN when the signal strength is the strongest. Some radio receivers output inverted values so this value may be higher than RSSI_CHAN_LOW

Range

Units

0 to 2000

PWM in microseconds

SCHED_ Parameters

SCHED_DEBUG: Scheduler debug level

Note: This parameter is for advanced users

Set to non-zero to enable scheduler debug messages. When set to show "Slips" the scheduler will display a message whenever a scheduled task is delayed due to too much CPU load. When set to ShowOverruns the scheduled will display a message whenever a task takes longer than the limit promised in the task table.

Values

Value

Meaning

0

Disabled

2

ShowSlips

3

ShowOverruns

SCHED_LOOP_RATE: Scheduling main loop rate

Note: This parameter is for advanced users
Note: Reboot required after change

This controls the rate of the main control loop in Hz. This should only be changed by developers. This only takes effect on restart. Values over 400 are considered highly experimental.

Range

Units

50 to 400

hertz

SCHED_OPTIONS: Scheduling options

Note: This parameter is for advanced users

This controls optional aspects of the scheduler.

Bitmask

Bit

Meaning

0

Enable per-task perf info

SCR_ Parameters

SCR_ENABLE: Enable Scripting

Note: This parameter is for advanced users
Note: Reboot required after change

Controls if scripting is enabled

Values

Value

Meaning

0

None

1

Lua Scripts

SCR_VM_I_COUNT: Scripting Virtual Machine Instruction Count

Note: This parameter is for advanced users

The number virtual machine instructions that can be run before considering a script to have taken an excessive amount of time

Increment

Range

10000

1000 to 1000000

SCR_HEAP_SIZE: Scripting Heap Size

Note: This parameter is for advanced users
Note: Reboot required after change

Amount of memory available for scripting

Increment

Range

1024

1024 to 1048576

SCR_DEBUG_OPTS: Scripting Debug Level

Note: This parameter is for advanced users

Debugging options

Bitmask

Bit

Meaning

0

No Scripts to run message if all scripts have stopped

1

Runtime messages for memory usage and execution time

2

Suppress logging scripts to dataflash

3

log runtime memory usage and execution time

4

Disable pre-arm check

5

Save CRC of current scripts to loaded and running checksum parameters enabling pre-arm

6

Disable heap expansion on allocation failure

SCR_USER1: Scripting User Parameter1

General purpose user variable input for scripts

SCR_USER2: Scripting User Parameter2

General purpose user variable input for scripts

SCR_USER3: Scripting User Parameter3

General purpose user variable input for scripts

SCR_USER4: Scripting User Parameter4

General purpose user variable input for scripts

SCR_USER5: Scripting User Parameter5

General purpose user variable input for scripts

SCR_USER6: Scripting User Parameter6

General purpose user variable input for scripts

SCR_DIR_DISABLE: Directory disable

Note: This parameter is for advanced users
Note: Reboot required after change

This will stop scripts being loaded from the given locations

Bitmask

Bit

Meaning

0

ROMFS

1

APM/scripts

SCR_LD_CHECKSUM: Loaded script checksum

Note: This parameter is for advanced users

Required XOR of CRC32 checksum of loaded scripts, vehicle will not arm with incorrect scripts loaded, -1 disables

SCR_RUN_CHECKSUM: Running script checksum

Note: This parameter is for advanced users

Required XOR of CRC32 checksum of running scripts, vehicle will not arm with incorrect scripts running, -1 disables

SCR_THD_PRIORITY: Scripting thread priority

Note: This parameter is for advanced users
Note: Reboot required after change

This sets the priority of the scripting thread. This is normally set to a low priority to prevent scripts from interfering with other parts of the system. Advanced users can change this priority if scripting needs to be prioritised for realtime applications. WARNING: changing this parameter can impact the stability of your flight controller. The scipting thread priority in this parameter is chosen based on a set of system level priorities for other subsystems. It is strongly recommended that you use the lowest priority that is sufficient for your application. Note that all scripts run at the same priority, so if you raise this priority you must carefully audit all lua scripts for behaviour that does not interfere with the operation of the system.

Values

Value

Meaning

0

Normal

1

IO Priority

2

Storage Priority

3

UART Priority

4

I2C Priority

5

SPI Priority

6

Timer Priority

7

Main Priority

8

Boost Priority

SCR_SDEV_EN: Scripting serial device enable

Note: This parameter is for advanced users
Note: Reboot required after change

Enable scripting serial devices

Values

Value

Meaning

0

Disabled

1

Enabled

SCR_SDEV1_PROTO: Serial protocol of scripting serial device

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of scripting serial device

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SCR_SDEV2_PROTO: Serial protocol of scripting serial device

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of scripting serial device

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SCR_SDEV3_PROTO: Serial protocol of scripting serial device

Note: This parameter is for advanced users
Note: Reboot required after change

Serial protocol of scripting serial device

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SERIAL Parameters

SERIAL0_BAUD: Serial0 baud rate

The baud rate used on the USB console. Most stm32-based boards can support rates of up to 1500. If you setup a rate you cannot support and then can't connect to your board you should load a firmware from a different vehicle type. That will reset all your parameters to defaults.

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

SERIAL0_PROTOCOL: Console protocol selection

Note: Reboot required after change

Control what protocol to use on the console.

Values

Value

Meaning

1

MAVLink1

2

MAVLink2

SERIAL1_PROTOCOL: Telem1 protocol selection

Note: Reboot required after change

Control what protocol to use on the Telem1 port. Note that the Frsky options require external converter hardware. See the wiki for details.

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SERIAL1_BAUD: Telem1 Baud Rate

The baud rate used on the Telem1 port. Most stm32-based boards can support rates of up to 1500. If you setup a rate you cannot support and then can't connect to your board you should load a firmware from a different vehicle type. That will reset all your parameters to defaults.

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

SERIAL2_PROTOCOL: Telemetry 2 protocol selection

Note: Reboot required after change

Control what protocol to use on the Telem2 port. Note that the Frsky options require external converter hardware. See the wiki for details.

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SERIAL2_BAUD: Telemetry 2 Baud Rate

The baud rate of the Telem2 port. Most stm32-based boards can support rates of up to 1500. If you setup a rate you cannot support and then can't connect to your board you should load a firmware from a different vehicle type. That will reset all your parameters to defaults.

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

SERIAL3_PROTOCOL: Serial 3 (GPS) protocol selection

Note: Reboot required after change

Control what protocol Serial 3 (GPS) should be used for. Note that the Frsky options require external converter hardware. See the wiki for details.

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SERIAL3_BAUD: Serial 3 (GPS) Baud Rate

The baud rate used for the Serial 3 (GPS). Most stm32-based boards can support rates of up to 1500. If you setup a rate you cannot support and then can't connect to your board you should load a firmware from a different vehicle type. That will reset all your parameters to defaults.

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

SERIAL4_PROTOCOL: Serial4 protocol selection

Note: Reboot required after change

Control what protocol Serial4 port should be used for. Note that the Frsky options require external converter hardware. See the wiki for details.

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SERIAL4_BAUD: Serial 4 Baud Rate

The baud rate used for Serial4. Most stm32-based boards can support rates of up to 1500. If you setup a rate you cannot support and then can't connect to your board you should load a firmware from a different vehicle type. That will reset all your parameters to defaults.

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

SERIAL5_PROTOCOL: Serial5 protocol selection

Note: Reboot required after change

Control what protocol Serial5 port should be used for. Note that the Frsky options require external converter hardware. See the wiki for details.

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SERIAL5_BAUD: Serial 5 Baud Rate

The baud rate used for Serial5. Most stm32-based boards can support rates of up to 1500. If you setup a rate you cannot support and then can't connect to your board you should load a firmware from a different vehicle type. That will reset all your parameters to defaults.

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

SERIAL6_PROTOCOL: Serial6 protocol selection

Note: Reboot required after change

Control what protocol Serial6 port should be used for. Note that the Frsky options require external converter hardware. See the wiki for details.

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SERIAL6_BAUD: Serial 6 Baud Rate

The baud rate used for Serial6. Most stm32-based boards can support rates of up to 1500. If you setup a rate you cannot support and then can't connect to your board you should load a firmware from a different vehicle type. That will reset all your parameters to defaults.

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

SERIAL1_OPTIONS: Telem1 options

Note: This parameter is for advanced users
Note: Reboot required after change

Control over UART options. The InvertRX option controls invert of the receive pin. The InvertTX option controls invert of the transmit pin. The HalfDuplex option controls half-duplex (onewire) mode, where both transmit and receive is done on the transmit wire. The Swap option allows the RX and TX pins to be swapped on STM32F7 based boards.

Bitmask

Bit

Meaning

0

InvertRX

1

InvertTX

2

HalfDuplex

3

SwapTXRX

4

RX_PullDown

5

RX_PullUp

6

TX_PullDown

7

TX_PullUp

8

RX_NoDMA

9

TX_NoDMA

10

Don’t forward mavlink to/from

11

DisableFIFO

12

Ignore Streamrate

SERIAL2_OPTIONS: Telem2 options

Note: This parameter is for advanced users
Note: Reboot required after change

Control over UART options. The InvertRX option controls invert of the receive pin. The InvertTX option controls invert of the transmit pin. The HalfDuplex option controls half-duplex (onewire) mode, where both transmit and receive is done on the transmit wire. The Swap option allows the RX and TX pins to be swapped on STM32F7 based boards.

Bitmask

Bit

Meaning

0

InvertRX

1

InvertTX

2

HalfDuplex

3

SwapTXRX

4

RX_PullDown

5

RX_PullUp

6

TX_PullDown

7

TX_PullUp

8

RX_NoDMA

9

TX_NoDMA

10

Don’t forward mavlink to/from

11

DisableFIFO

12

Ignore Streamrate

SERIAL3_OPTIONS: Serial3 options

Note: This parameter is for advanced users
Note: Reboot required after change

Control over UART options. The InvertRX option controls invert of the receive pin. The InvertTX option controls invert of the transmit pin. The HalfDuplex option controls half-duplex (onewire) mode, where both transmit and receive is done on the transmit wire. The Swap option allows the RX and TX pins to be swapped on STM32F7 based boards.

Bitmask

Bit

Meaning

0

InvertRX

1

InvertTX

2

HalfDuplex

3

SwapTXRX

4

RX_PullDown

5

RX_PullUp

6

TX_PullDown

7

TX_PullUp

8

RX_NoDMA

9

TX_NoDMA

10

Don’t forward mavlink to/from

11

DisableFIFO

12

Ignore Streamrate

SERIAL4_OPTIONS: Serial4 options

Note: This parameter is for advanced users
Note: Reboot required after change

Control over UART options. The InvertRX option controls invert of the receive pin. The InvertTX option controls invert of the transmit pin. The HalfDuplex option controls half-duplex (onewire) mode, where both transmit and receive is done on the transmit wire. The Swap option allows the RX and TX pins to be swapped on STM32F7 based boards.

Bitmask

Bit

Meaning

0

InvertRX

1

InvertTX

2

HalfDuplex

3

SwapTXRX

4

RX_PullDown

5

RX_PullUp

6

TX_PullDown

7

TX_PullUp

8

RX_NoDMA

9

TX_NoDMA

10

Don’t forward mavlink to/from

11

DisableFIFO

12

Ignore Streamrate

SERIAL5_OPTIONS: Serial5 options

Note: This parameter is for advanced users
Note: Reboot required after change

Control over UART options. The InvertRX option controls invert of the receive pin. The InvertTX option controls invert of the transmit pin. The HalfDuplex option controls half-duplex (onewire) mode, where both transmit and receive is done on the transmit wire. The Swap option allows the RX and TX pins to be swapped on STM32F7 based boards.

Bitmask

Bit

Meaning

0

InvertRX

1

InvertTX

2

HalfDuplex

3

SwapTXRX

4

RX_PullDown

5

RX_PullUp

6

TX_PullDown

7

TX_PullUp

8

RX_NoDMA

9

TX_NoDMA

10

Don’t forward mavlink to/from

11

DisableFIFO

12

Ignore Streamrate

SERIAL6_OPTIONS: Serial6 options

Note: This parameter is for advanced users
Note: Reboot required after change

Control over UART options. The InvertRX option controls invert of the receive pin. The InvertTX option controls invert of the transmit pin. The HalfDuplex option controls half-duplex (onewire) mode, where both transmit and receive is done on the transmit wire. The Swap option allows the RX and TX pins to be swapped on STM32F7 based boards.

Bitmask

Bit

Meaning

0

InvertRX

1

InvertTX

2

HalfDuplex

3

SwapTXRX

4

RX_PullDown

5

RX_PullUp

6

TX_PullDown

7

TX_PullUp

8

RX_NoDMA

9

TX_NoDMA

10

Don’t forward mavlink to/from

11

DisableFIFO

12

Ignore Streamrate

SERIAL_PASS1: Serial passthru first port

Note: This parameter is for advanced users

This sets one side of pass-through between two serial ports. Once both sides are set then all data received on either port will be passed to the other port

Values

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

SERIAL_PASS2: Serial passthru second port

Note: This parameter is for advanced users

This sets one side of pass-through between two serial ports. Once both sides are set then all data received on either port will be passed to the other port

Values

Value

Meaning

-1

Disabled

0

Serial0

1

Serial1

2

Serial2

3

Serial3

4

Serial4

5

Serial5

6

Serial6

SERIAL_PASSTIMO: Serial passthru timeout

Note: This parameter is for advanced users

This sets a timeout for serial pass-through in seconds. When the pass-through is enabled by setting the SERIAL_PASS1 and SERIAL_PASS2 parameters then it remains in effect until no data comes from the first port for SERIAL_PASSTIMO seconds. This allows the port to revent to its normal usage (such as MAVLink connection to a GCS) when it is no longer needed. A value of 0 means no timeout.

Range

Units

0 to 120

seconds

SERIAL7_PROTOCOL: Serial7 protocol selection

Note: Reboot required after change

Control what protocol Serial7 port should be used for. Note that the Frsky options require external converter hardware. See the wiki for details.

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SERIAL7_BAUD: Serial 7 Baud Rate

The baud rate used for Serial7. Most stm32-based boards can support rates of up to 1500. If you setup a rate you cannot support and then can't connect to your board you should load a firmware from a different vehicle type. That will reset all your parameters to defaults.

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

SERIAL7_OPTIONS: Serial7 options

Note: This parameter is for advanced users
Note: Reboot required after change

Control over UART options. The InvertRX option controls invert of the receive pin. The InvertTX option controls invert of the transmit pin. The HalfDuplex option controls half-duplex (onewire) mode, where both transmit and receive is done on the transmit wire. The Swap option allows the RX and TX pins to be swapped on STM32F7 based boards.

Bitmask

Bit

Meaning

0

InvertRX

1

InvertTX

2

HalfDuplex

3

SwapTXRX

4

RX_PullDown

5

RX_PullUp

6

TX_PullDown

7

TX_PullUp

8

RX_NoDMA

9

TX_NoDMA

10

Don’t forward mavlink to/from

11

DisableFIFO

12

Ignore Streamrate

SERIAL8_PROTOCOL: Serial8 protocol selection

Note: Reboot required after change

Control what protocol Serial8 port should be used for. Note that the Frsky options require external converter hardware. See the wiki for details.

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SERIAL8_BAUD: Serial 8 Baud Rate

The baud rate used for Serial8. Most stm32-based boards can support rates of up to 1500. If you setup a rate you cannot support and then can't connect to your board you should load a firmware from a different vehicle type. That will reset all your parameters to defaults.

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

SERIAL8_OPTIONS: Serial8 options

Note: This parameter is for advanced users
Note: Reboot required after change

Control over UART options. The InvertRX option controls invert of the receive pin. The InvertTX option controls invert of the transmit pin. The HalfDuplex option controls half-duplex (onewire) mode, where both transmit and receive is done on the transmit wire. The Swap option allows the RX and TX pins to be swapped on STM32F7 based boards.

Bitmask

Bit

Meaning

0

InvertRX

1

InvertTX

2

HalfDuplex

3

SwapTXRX

4

RX_PullDown

5

RX_PullUp

6

TX_PullDown

7

TX_PullUp

8

RX_NoDMA

9

TX_NoDMA

10

Don’t forward mavlink to/from

11

DisableFIFO

12

Ignore Streamrate

SERIAL9_PROTOCOL: Serial9 protocol selection

Note: Reboot required after change

Control what protocol Serial9 port should be used for. Note that the Frsky options require external converter hardware. See the wiki for details.

Values

Value

Meaning

-1

None

1

MAVLink1

2

MAVLink2

3

Frsky D

4

Frsky SPort

5

GPS

7

Alexmos Gimbal Serial

8

Gimbal

9

Rangefinder

10

FrSky SPort Passthrough (OpenTX)

11

Lidar360

13

Beacon

14

Volz servo out

15

SBus servo out

16

ESC Telemetry

17

Devo Telemetry

18

OpticalFlow

19

RobotisServo

20

NMEA Output

21

WindVane

22

SLCAN

23

RCIN

24

EFI Serial

25

LTM

26

RunCam

27

HottTelem

28

Scripting

29

Crossfire VTX

30

Generator

31

Winch

32

MSP

33

DJI FPV

34

AirSpeed

35

ADSB

36

AHRS

37

SmartAudio

38

FETtecOneWire

39

Torqeedo

40

AIS

41

CoDevESC

42

DisplayPort

43

MAVLink High Latency

44

IRC Tramp

45

DDS XRCE

46

IMUDATA

48

PPP

SERIAL9_BAUD: Serial 9 Baud Rate

The baud rate used for Serial8. Most stm32-based boards can support rates of up to 1500. If you setup a rate you cannot support and then can't connect to your board you should load a firmware from a different vehicle type. That will reset all your parameters to defaults.

Values

Value

Meaning

1

1200

2

2400

4

4800

9

9600

19

19200

38

38400

57

57600

111

111100

115

115200

230

230400

256

256000

460

460800

500

500000

921

921600

1500

1500000

2000

2000000

SERIAL9_OPTIONS: Serial9 options

Note: This parameter is for advanced users
Note: Reboot required after change

Control over UART options. The InvertRX option controls invert of the receive pin. The InvertTX option controls invert of the transmit pin. The HalfDuplex option controls half-duplex (onewire) mode, where both transmit and receive is done on the transmit wire. The Swap option allows the RX and TX pins to be swapped on STM32F7 based boards.

Bitmask

Bit

Meaning

0

InvertRX

1

InvertTX

2

HalfDuplex

3

SwapTXRX

4

RX_PullDown

5

RX_PullUp

6

TX_PullDown

7

TX_PullUp

8

RX_NoDMA

9

TX_NoDMA

10

Don’t forward mavlink to/from

11

DisableFIFO

12

Ignore Streamrate

SERVO Parameters

SERVO_RATE: Servo default output rate

Note: This parameter is for advanced users

Default output rate in Hz for all PWM outputs.

Range

Units

25 to 400

hertz

SERVO_DSHOT_RATE: Servo DShot output rate

Note: This parameter is for advanced users

DShot output rate for all outputs as a multiple of the loop rate. 0 sets the output rate to be fixed at 1Khz for low loop rates. This value should never be set below 500Hz.

Values

Value

Meaning

0

1Khz

1

loop-rate

2

double loop-rate

3

triple loop-rate

4

quadruple loop rate

SERVO_DSHOT_ESC: Servo DShot ESC type

Note: This parameter is for advanced users

DShot ESC type for all outputs. The ESC type affects the range of DShot commands available and the bit widths used. None means that no dshot commands will be executed. Some ESC types support Extended DShot Telemetry (EDT) which allows telemetry other than RPM data to be returned when using bi-directional dshot. If you enable EDT you must install EDT capable firmware for correct operation.

Values

Value

Meaning

0

None

1

BLHeli32/Kiss/AM32

2

BLHeli_S/BlueJay

3

BLHeli32/AM32/Kiss+EDT

4

BLHeli_S/BlueJay+EDT

SERVO_GPIO_MASK: Servo GPIO mask

Note: This parameter is for advanced users
Note: Reboot required after change

Bitmask of outputs which will be available as GPIOs. Any output with either the function set to -1 or with the corresponding bit set in this mask will be available for use as a GPIO pin

Bitmask

Bit

Meaning

0

Servo 1

1

Servo 2

2

Servo 3

3

Servo 4

4

Servo 5

5

Servo 6

6

Servo 7

7

Servo 8

8

Servo 9

9

Servo 10

10

Servo 11

11

Servo 12

12

Servo 13

13

Servo 14

14

Servo 15

15

Servo 16

16

Servo 17

17

Servo 18

18

Servo 19

19

Servo 20

20

Servo 21

21

Servo 22

22

Servo 23

23

Servo 24

24

Servo 25

25

Servo 26

26

Servo 27

27

Servo 28

28

Servo 29

29

Servo 30

30

Servo 31

31

Servo 32

SERVO_RC_FS_MSK: Servo RC Failsafe Mask

Note: This parameter is for advanced users

Bitmask of scaled passthru output channels which will be set to their trim value during rc failsafe instead of holding their last position before failsafe.

Bitmask

Bit

Meaning

0

RCIN1Scaled

1

RCIN2Scaled

2

RCIN3Scaled

3

RCIN4Scaled

4

RCIN5Scaled

5

RCIN6Scaled

6

RCIN7Scaled

7

RCIN8Scaled

8

RCIN9Scaled

9

RCIN10Scaled

10

RCIN11Scaled

11

SRCIN12Scaled

12

RCIN13Scaled

13

RCIN14Scaled

14

RCIN15Scaled

15

RCIN16Scaled

SERVO_32_ENABLE: Enable outputs 17 to 31

Note: This parameter is for advanced users

This allows for up to 32 outputs, enabling parameters for outputs above 16

Values

Value

Meaning

0

Disabled

1

Enabled

SERVO10_ Parameters

SERVO10_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO10_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO10_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO10_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO10_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO11_ Parameters

SERVO11_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO11_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO11_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO11_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO11_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO12_ Parameters

SERVO12_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO12_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO12_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO12_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO12_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO13_ Parameters

SERVO13_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO13_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO13_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO13_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO13_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO14_ Parameters

SERVO14_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO14_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO14_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO14_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO14_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO15_ Parameters

SERVO15_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO15_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO15_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO15_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO15_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO16_ Parameters

SERVO16_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO16_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO16_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO16_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO16_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO17_ Parameters

SERVO17_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO17_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO17_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO17_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO17_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO18_ Parameters

SERVO18_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO18_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO18_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO18_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO18_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO19_ Parameters

SERVO19_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO19_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO19_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO19_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO19_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO1_ Parameters

SERVO1_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO1_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO1_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO1_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO1_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO20_ Parameters

SERVO20_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO20_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO20_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO20_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO20_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO21_ Parameters

SERVO21_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO21_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO21_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO21_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO21_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO22_ Parameters

SERVO22_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO22_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO22_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO22_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO22_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO23_ Parameters

SERVO23_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO23_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO23_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO23_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO23_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO24_ Parameters

SERVO24_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO24_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO24_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO24_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO24_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO25_ Parameters

SERVO25_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO25_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO25_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO25_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO25_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO26_ Parameters

SERVO26_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO26_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO26_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO26_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO26_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO27_ Parameters

SERVO27_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO27_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO27_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO27_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO27_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO28_ Parameters

SERVO28_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO28_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO28_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO28_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO28_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO29_ Parameters

SERVO29_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO29_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO29_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO29_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO29_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO2_ Parameters

SERVO2_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO2_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO2_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO2_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO2_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO30_ Parameters

SERVO30_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO30_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO30_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO30_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO30_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO31_ Parameters

SERVO31_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO31_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO31_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO31_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO31_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO32_ Parameters

SERVO32_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO32_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO32_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO32_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO32_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO3_ Parameters

SERVO3_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO3_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO3_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO3_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO3_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO4_ Parameters

SERVO4_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO4_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO4_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO4_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO4_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO5_ Parameters

SERVO5_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO5_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO5_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO5_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO5_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO6_ Parameters

SERVO6_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO6_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO6_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO6_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO6_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO7_ Parameters

SERVO7_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO7_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO7_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO7_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO7_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO8_ Parameters

SERVO8_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO8_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO8_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO8_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO8_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO9_ Parameters

SERVO9_MIN: Minimum PWM

minimum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO9_MAX: Maximum PWM

maximum PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO9_TRIM: Trim PWM

Trim PWM pulse width in microseconds. Typically 1000 is lower limit, 1500 is neutral and 2000 is upper limit.

Increment

Range

Units

1

800 to 2200

PWM in microseconds

SERVO9_REVERSED: Servo reverse

Reverse servo operation. Set to 0 for normal operation. Set to 1 to reverse this output channel.

Values

Value

Meaning

0

Normal

1

Reversed

SERVO9_FUNCTION: Servo output function

Note: Reboot required after change

Function assigned to this servo. Setting this to Disabled(0) will setup this output for control by auto missions or MAVLink servo set commands. any other value will enable the corresponding function

Values

Value

Meaning

-1

GPIO

0

Disabled

1

RCPassThru

6

Mount1Yaw

7

Mount1Pitch

8

Mount1Roll

9

Mount1Retract

10

CameraTrigger

12

Mount2Yaw

13

Mount2Pitch

14

Mount2Roll

15

Mount2Retract

22

SprayerPump

23

SprayerSpinner

27

Parachute

28

Gripper

29

LandingGear

30

EngineRunEnable

31

HeliRSC

32

HeliTailRSC

33

Motor1

34

Motor2

35

Motor3

36

Motor4

37

Motor5

38

Motor6

39

Motor7

40

Motor8

51

RCIN1

52

RCIN2

53

RCIN3

54

RCIN4

55

RCIN5

56

RCIN6

57

RCIN7

58

RCIN8

59

RCIN9

60

RCIN10

61

RCIN11

62

RCIN12

63

RCIN13

64

RCIN14

65

RCIN15

66

RCIN16

73

ThrottleLeft

74

ThrottleRight

75

TiltMotorFrontLeft

76

TiltMotorFrontRight

81

BoostThrottle

82

Motor9

83

Motor10

84

Motor11

85

Motor12

88

Winch

90

CameraISO

91

CameraAperture

92

CameraFocus

93

CameraShutterSpeed

94

Script1

95

Script2

96

Script3

97

Script4

98

Script5

99

Script6

100

Script7

101

Script8

102

Script9

103

Script10

104

Script11

105

Script12

106

Script13

107

Script14

108

Script15

109

Script16

120

NeoPixel1

121

NeoPixel2

122

NeoPixel3

123

NeoPixel4

124

RateRoll

125

RatePitch

126

RateThrust

127

RateYaw

129

ProfiLED1

130

ProfiLED2

131

ProfiLED3

132

ProfiLEDClock

133

Winch Clutch

134

SERVOn_MIN

135

SERVOn_TRIM

136

SERVOn_MAX

138

Alarm

139

Alarm Inverted

140

RCIN1Scaled

141

RCIN2Scaled

142

RCIN3Scaled

143

RCIN4Scaled

144

RCIN5Scaled

145

RCIN6Scaled

146

RCIN7Scaled

147

RCIN8Scaled

148

RCIN9Scaled

149

RCIN10Scaled

150

RCIN11Scaled

151

RCIN12Scaled

152

RCIN13Scaled

153

RCIN14Scaled

154

RCIN15Scaled

155

RCIN16Scaled

SERVO_BLH_ Parameters

SERVO_BLH_MASK: BLHeli Channel Bitmask

Note: This parameter is for advanced users
Note: Reboot required after change

Enable of BLHeli pass-thru servo protocol support to specific channels. This mask is in addition to motors enabled using SERVO_BLH_AUTO (if any)

Bitmask

Bit

Meaning

0

Channel1

1

Channel2

2

Channel3

3

Channel4

4

Channel5

5

Channel6

6

Channel7

7

Channel8

8

Channel9

9

Channel10

10

Channel11

11

Channel12

12

Channel13

13

Channel14

14

Channel15

15

Channel16

16

Channel 17

17

Channel 18

18

Channel 19

19

Channel 20

20

Channel 21

21

Channel 22

22

Channel 23

23

Channel 24

24

Channel 25

25

Channel 26

26

Channel 27

27

Channel 28

28

Channel 29

29

Channel 30

30

Channel 31

31

Channel 32

SERVO_BLH_AUTO: BLHeli pass-thru auto-enable for multicopter motors

Note: Reboot required after change

If set to 1 this auto-enables BLHeli pass-thru support for all multicopter motors

Values

Value

Meaning

0

Disabled

1

Enabled

SERVO_BLH_TEST: BLHeli internal interface test

Note: This parameter is for advanced users

Setting SERVO_BLH_TEST to a motor number enables an internal test of the BLHeli ESC protocol to the corresponding ESC. The debug output is displayed on the USB console.

Values

Value

Meaning

0

Disabled

1

TestMotor1

2

TestMotor2

3

TestMotor3

4

TestMotor4

5

TestMotor5

6

TestMotor6

7

TestMotor7

8

TestMotor8

SERVO_BLH_TMOUT: BLHeli protocol timeout

This sets the inactivity timeout for the BLHeli protocol in seconds. If no packets are received in this time normal MAVLink operations are resumed. A value of 0 means no timeout

Range

Units

0 to 300

seconds

SERVO_BLH_TRATE: BLHeli telemetry rate

This sets the rate in Hz for requesting telemetry from ESCs. It is the rate per ESC. Setting to zero disables telemetry requests

Range

Units

0 to 500

hertz

SERVO_BLH_DEBUG: BLHeli debug level

When set to 1 this enabled verbose debugging output over MAVLink when the blheli protocol is active. This can be used to diagnose failures.

Values

Value

Meaning

0

Disabled

1

Enabled

SERVO_BLH_OTYPE: BLHeli output type override

Note: This parameter is for advanced users
Note: Reboot required after change

When set to a non-zero value this overrides the output type for the output channels given by SERVO_BLH_MASK. This can be used to enable DShot on outputs that are not part of the multicopter motors group.

Values

Value

Meaning

0

None

1

OneShot

2

OneShot125

3

Brushed

4

DShot150

5

DShot300

6

DShot600

7

DShot1200

SERVO_BLH_PORT: Control port

Note: This parameter is for advanced users

This sets the mavlink channel to use for blheli pass-thru. The channel number is determined by the number of serial ports configured to use mavlink. So 0 is always the console, 1 is the next serial port using mavlink, 2 the next after that and so on.

Values

Value

Meaning

0

Console

1

Mavlink Serial Channel1

2

Mavlink Serial Channel2

3

Mavlink Serial Channel3

4

Mavlink Serial Channel4

5

Mavlink Serial Channel5

SERVO_BLH_POLES: BLHeli Motor Poles

Note: This parameter is for advanced users
Note: Reboot required after change

This allows calculation of true RPM from ESC's eRPM. The default is 14.

Range

1 to 127

SERVO_BLH_3DMASK: BLHeli bitmask of 3D channels

Note: This parameter is for advanced users
Note: Reboot required after change

Mask of channels which are dynamically reversible. This is used to configure ESCs in '3D' mode, allowing for the motor to spin in either direction. Do not use for channels selected with SERVO_BLH_RVMASK.

Bitmask

Bit

Meaning

0

Channel1

1

Channel2

2

Channel3

3

Channel4

4

Channel5

5

Channel6

6

Channel7

7

Channel8

8

Channel9

9

Channel10

10

Channel11

11

Channel12

12

Channel13

13

Channel14

14

Channel15

15

Channel16

16

Channel 17

17

Channel 18

18

Channel 19

19

Channel 20

20

Channel 21

21

Channel 22

22

Channel 23

23

Channel 24

24

Channel 25

25

Channel 26

26

Channel 27

27

Channel 28

28

Channel 29

29

Channel 30

30

Channel 31

31

Channel 32

SERVO_BLH_BDMASK: BLHeli bitmask of bi-directional dshot channels

Note: This parameter is for advanced users
Note: Reboot required after change

Mask of channels which support bi-directional dshot telemetry. This is used for ESCs which have firmware that supports bi-directional dshot allowing fast rpm telemetry values to be returned for the harmonic notch.

Bitmask

Bit

Meaning

0

Channel1

1

Channel2

2

Channel3

3

Channel4

4

Channel5

5

Channel6

6

Channel7

7

Channel8

8

Channel9

9

Channel10

10

Channel11

11

Channel12

12

Channel13

13

Channel14

14

Channel15

15

Channel16

16

Channel 17

17

Channel 18

18

Channel 19

19

Channel 20

20

Channel 21

21

Channel 22

22

Channel 23

23

Channel 24

24

Channel 25

25

Channel 26

26

Channel 27

27

Channel 28

28

Channel 29

29

Channel 30

30

Channel 31

31

Channel 32

SERVO_BLH_RVMASK: BLHeli bitmask of reversed channels

Note: This parameter is for advanced users
Note: Reboot required after change

Mask of channels which are reversed. This is used to configure ESCs to reverse motor direction for unidirectional rotation. Do not use for channels selected with SERVO_BLH_3DMASK.

Bitmask

Bit

Meaning

0

Channel1

1

Channel2

2

Channel3

3

Channel4

4

Channel5

5

Channel6

6

Channel7

7

Channel8

8

Channel9

9

Channel10

10

Channel11

11

Channel12

12

Channel13

13

Channel14

14

Channel15

15

Channel16

16

Channel 17

17

Channel 18

18

Channel 19

19

Channel 20

20

Channel 21

21

Channel 22

22

Channel 23

23

Channel 24

24

Channel 25

25

Channel 26

26

Channel 27

27

Channel 28

28

Channel 29

29

Channel 30

30

Channel 31

31

Channel 32

SERVO_FTW_ Parameters

SERVO_FTW_MASK: Servo channel output bitmask

Note: Reboot required after change

Servo channel mask specifying FETtec ESC output.

Bitmask

Bit

Meaning

0

SERVO1

1

SERVO2

2

SERVO3

3

SERVO4

4

SERVO5

5

SERVO6

6

SERVO7

7

SERVO8

8

SERVO9

9

SERVO10

10

SERVO11

11

SERVO12

SERVO_FTW_RVMASK: Servo channel reverse rotation bitmask

Servo channel mask to reverse rotation of FETtec ESC outputs.

Bitmask

Bit

Meaning

0

SERVO1

1

SERVO2

2

SERVO3

3

SERVO4

4

SERVO5

5

SERVO6

6

SERVO7

7

SERVO8

8

SERVO9

9

SERVO10

10

SERVO11

11

SERVO12

SERVO_FTW_POLES: Nr. electrical poles

Number of motor electrical poles

Range

2 to 50

SERVO_ROB_ Parameters

SERVO_ROB_POSMIN: Robotis servo position min

Position minimum at servo min value. This should be within the position control range of the servos, normally 0 to 4095

Range

0 to 4095

SERVO_ROB_POSMAX: Robotis servo position max

Position maximum at servo max value. This should be within the position control range of the servos, normally 0 to 4095

Range

0 to 4095

SERVO_SBUS_ Parameters

SERVO_SBUS_RATE: SBUS default output rate

Note: This parameter is for advanced users

This sets the SBUS output frame rate in Hz.

Range

Units

25 to 250

hertz

SERVO_VOLZ_ Parameters

SERVO_VOLZ_MASK: Channel Bitmask

Enable of volz servo protocol to specific channels

Bitmask

Bit

Meaning

0

Channel1

1

Channel2

2

Channel3

3

Channel4

4

Channel5

5

Channel6

6

Channel7

7

Channel8

8

Channel9

9

Channel10

10

Channel11

11

Channel12

12

Channel13

13

Channel14

14

Channel15

15

Channel16

16

Channel17

17

Channel18

18

Channel19

19

Channel20

20

Channel21

21

Channel22

22

Channel23

23

Channel24

24

Channel25

25

Channel26

26

Channel27

28

Channel29

29

Channel30

30

Channel31

31

Channel32

SERVO_VOLZ_RANGE: Range of travel

Range to map between 1000 and 2000 PWM. Default value of 200 gives full +-100 deg range of extended position command. This results in 0.2 deg movement per US change in PWM. If the full range is not needed it can be reduced to increase resolution. 40 deg range gives 0.04 deg movement per US change in PWM, this is higher resolution than possible with the VOLZ protocol so further reduction in range will not improve resolution. Reduced range does allow PWMs outside the 1000 to 2000 range, with 40 deg range 750 PWM results in a angle of -30 deg, 2250 would be +30 deg. This is still limited by the 200 deg maximum range of the actuator.

Units

degrees

SID Parameters

SID_AXIS: System identification axis

Controls which axis are being excited. Set to non-zero to see more parameters

Values

Value

Meaning

0

None

1

Input Roll Angle

2

Input Pitch Angle

3

Input Yaw Angle

4

Recovery Roll Angle

5

Recovery Pitch Angle

6

Recovery Yaw Angle

7

Rate Roll

8

Rate Pitch

9

Rate Yaw

10

Mixer Roll

11

Mixer Pitch

12

Mixer Yaw

13

Mixer Thrust

14

Measured Lateral Position

15

Measured Longitudinal Position

16

Measured Lateral Velocity

17

Measured Longitudinal Velocity

18

Input Lateral Velocity

19

Input Longitudinal Velocity

SID_MAGNITUDE: System identification Chirp Magnitude

Magnitude of sweep in deg, deg/s and 0-1 for mixer outputs.

SID_F_START_HZ: System identification Start Frequency

Frequency at the start of the sweep

Range

Units

0.01 to 100

hertz

SID_F_STOP_HZ: System identification Stop Frequency

Frequency at the end of the sweep

Range

Units

0.01 to 100

hertz

SID_T_FADE_IN: System identification Fade in time

Time to reach maximum amplitude of sweep

Range

Units

0 to 20

seconds

SID_T_REC: System identification Total Sweep length

Time taken to complete the sweep

Range

Units

0 to 255

seconds

SID_T_FADE_OUT: System identification Fade out time

Time to reach zero amplitude at the end of the sweep

Range

Units

0 to 5

seconds

Simulation Parameters

SIM_ACC1_BIAS_X: Accel 1 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (X-axis)

SIM_ACC1_BIAS_Y: Accel 1 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (Y-axis)

SIM_ACC1_BIAS_Z: Accel 1 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (Z-axis)

SIM_ACC1_RND: Accel 1 motor noise factor

Note: This parameter is for advanced users

scaling factor for simulated vibration from motors

SIM_ACC1_SCAL_X: Accel 1 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (X-axis)

SIM_ACC1_SCAL_Y: Accel 1 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (Y-axis)

SIM_ACC1_SCAL_Z: Accel 1 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (Z-axis)

SIM_ACC2_BIAS_X: Accel 2 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (X-axis)

SIM_ACC2_BIAS_Y: Accel 2 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (Y-axis)

SIM_ACC2_BIAS_Z: Accel 2 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (Z-axis)

SIM_ACC2_RND: Accel 2 motor noise factor

Note: This parameter is for advanced users

scaling factor for simulated vibration from motors

SIM_ACC2_SCAL_X: Accel 2 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (X-axis)

SIM_ACC2_SCAL_Y: Accel 2 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (Y-axis)

SIM_ACC2_SCAL_Z: Accel 2 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (Z-axis)

SIM_ACC3_BIAS_X: Accel 3 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (X-axis)

SIM_ACC3_BIAS_Y: Accel 3 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (Y-axis)

SIM_ACC3_BIAS_Z: Accel 3 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (Z-axis)

SIM_ACC3_RND: Accel 3 motor noise factor

Note: This parameter is for advanced users

scaling factor for simulated vibration from motors

SIM_ACC3_SCAL_X: Accel 3 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (X-axis)

SIM_ACC3_SCAL_Y: Accel 3 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (Y-axis)

SIM_ACC3_SCAL_Z: Accel 3 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (Z-axis)

SIM_ACC4_BIAS_X: Accel 4 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (X-axis)

SIM_ACC4_BIAS_Y: Accel 4 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (Y-axis)

SIM_ACC4_BIAS_Z: Accel 4 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (Z-axis)

SIM_ACC4_RND: Accel 4 motor noise factor

Note: This parameter is for advanced users

scaling factor for simulated vibration from motors

SIM_ACC4_SCAL_X: Accel 4 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (X-axis)

SIM_ACC4_SCAL_Y: Accel 4 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (Y-axis)

SIM_ACC4_SCAL_Z: Accel 4 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (Z-axis)

SIM_ACC5_BIAS_X: Accel 5 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (X-axis)

SIM_ACC5_BIAS_Y: Accel 5 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (Y-axis)

SIM_ACC5_BIAS_Z: Accel 5 bias

Note: This parameter is for advanced users

bias of simulated accelerometer sensor (Z-axis)

SIM_ACC5_RND: Accel 5 motor noise factor

Note: This parameter is for advanced users

scaling factor for simulated vibration from motors

SIM_ACC5_SCAL_X: Accel 4 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (X-axis)

SIM_ACC5_SCAL_Y: Accel 4 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (Y-axis)

SIM_ACC5_SCAL_Z: Accel 4 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated accelerometer (Z-axis)

SIM_ACCEL1_FAIL: ACCEL1 Failure

Note: This parameter is for advanced users

Simulated failure of ACCEL1

Values

Value

Meaning

0

Disabled

1

ACCEL1 Failure

SIM_ACCEL2_FAIL: ACCEL2 Failure

Note: This parameter is for advanced users

Simulated failure of ACCEL2

Values

Value

Meaning

0

Disabled

1

ACCEL2 Failure

SIM_ACCEL3_FAIL: ACCEL3 Failure

Note: This parameter is for advanced users

Simulated failure of ACCEL3

Values

Value

Meaning

0

Disabled

1

ACCEL3 Failure

SIM_ACCEL4_FAIL: ACCEL4 Failure

Note: This parameter is for advanced users

Simulated failure of ACCEL4

Values

Value

Meaning

0

Disabled

1

ACCEL4 Failure

SIM_ACCEL5_FAIL: ACCEL5 Failure

Note: This parameter is for advanced users

Simulated failure of ACCEL5

Values

Value

Meaning

0

Disabled

1

ACCEL5 Failure

SIM_ACC_FAIL_MSK: Accelerometer Failure Mask

Note: This parameter is for advanced users

Determines if the acclerometer reading updates are stopped when for an IMU simulated failure by ACCELx_FAIL params

Values

Value

Meaning

0

Disabled

1

Readings stopped

SIM_ACC_FILE_RW: Accelerometer data to/from files

Read and write accelerometer data to/from files

Values

Value

Meaning

0

Stop writing data

1

Read data from file

2

Write data to a file

3

Read data from file and stop on EOF

SIM_ADSB_ALT: ADSB altitude of another aircraft

Simulated ADSB altitude of another aircraft

Units

meters

SIM_ADSB_COUNT: Number of ADSB aircrafts

Total number of ADSB simulated aircraft

SIM_ADSB_RADIUS: ADSB radius stddev of another aircraft

Simulated standard deviation of radius in ADSB of another aircraft

Units

meters

SIM_ADSB_TX: ADSB transmit enable

ADSB transceiever enable and disable

Values

Value

Meaning

0

Transceiever disable

1

Transceiever enable

SIM_ADSB_TYPES: Simulated ADSB Type mask

Note: This parameter is for advanced users

specifies which simulated ADSB types are active

Bitmask

Bit

Meaning

0

MAVLink

3

SageTechMXS

SIM_ARSPD2_FAIL: Airspeed sensor failure

Note: This parameter is for advanced users

Simulates Airspeed sensor 1 failure

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_ARSPD2_FAILP: Airspeed sensor failure pressure

Note: This parameter is for advanced users

Simulated airspeed sensor failure pressure

Units

pascal

SIM_ARSPD2_PITOT: Airspeed pitot tube failure pressure

Note: This parameter is for advanced users

Simulated airspeed sensor pitot tube failure pressure

Units

pascal

SIM_ARSPD2_RATIO: Airspeed ratios

Note: This parameter is for advanced users

Simulated airspeed sensor ratio

SIM_ARSPD2_SIGN: Airspeed signflip

Note: This parameter is for advanced users

Simulated airspeed sensor with reversed pitot/static connections

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_ARSPD_FAIL: Airspeed sensor failure

Note: This parameter is for advanced users

Simulates Airspeed sensor 1 failure

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_ARSPD_FAILP: Airspeed sensor failure pressure

Note: This parameter is for advanced users

Simulated airspeed sensor failure pressure

Units

pascal

SIM_ARSPD_PITOT: Airspeed pitot tube failure pressure

Note: This parameter is for advanced users

Simulated airspeed sensor pitot tube failure pressure

Units

pascal

SIM_ARSPD_RATIO: Airspeed ratios

Note: This parameter is for advanced users

Simulated airspeed sensor ratio

SIM_ARSPD_SIGN: Airspeed signflip

Note: This parameter is for advanced users

Simulated airspeed sensor with reversed pitot/static connections

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_BAR2_DELAY: Barometer delay

Note: This parameter is for advanced users

Barometer data time delay

Units

milliseconds

SIM_BAR2_DISABLE: Barometer disable

Note: This parameter is for advanced users

Disable barometer in SITL

Values

Value

Meaning

0

Disable

1

Enable

SIM_BAR2_DRIFT: Barometer altitude drift

Note: This parameter is for advanced users

Barometer altitude drifts at this rate

Units

meters per second

SIM_BAR2_FREEZE: Barometer freeze

Note: This parameter is for advanced users

Freeze barometer to last recorded altitude

SIM_BAR2_GLITCH: Barometer glitch

Note: This parameter is for advanced users

Barometer glitch height in SITL

Units

meters

SIM_BAR2_RND: Barometer noise

Note: This parameter is for advanced users

Barometer noise in height

Units

meters

SIM_BAR2_WCF_BAK: Wind coefficient backward

Note: This parameter is for advanced users

Barometer wind coefficient direction backward in SITL

SIM_BAR2_WCF_DN: Wind coefficient down

Note: This parameter is for advanced users

Barometer wind coefficient direction down in SITL

SIM_BAR2_WCF_FWD: Wind coefficient forward

Note: This parameter is for advanced users

Barometer wind coefficient direction forward in SITL

SIM_BAR2_WCF_LFT: Wind coefficient left

Note: This parameter is for advanced users

Barometer wind coefficient direction left in SITL

SIM_BAR2_WCF_RGT: Wind coefficient right

Note: This parameter is for advanced users

Barometer wind coefficient direction right in SITL

SIM_BAR2_WCF_UP: Wind coefficient up

Note: This parameter is for advanced users

Barometer wind coefficient direction up in SITL

SIM_BAR3_DELAY: Barometer delay

Note: This parameter is for advanced users

Barometer data time delay

Units

milliseconds

SIM_BAR3_DISABLE: Barometer disable

Note: This parameter is for advanced users

Disable barometer in SITL

Values

Value

Meaning

0

Disable

1

Enable

SIM_BAR3_DRIFT: Barometer altitude drift

Note: This parameter is for advanced users

Barometer altitude drifts at this rate

Units

meters per second

SIM_BAR3_FREEZE: Barometer freeze

Note: This parameter is for advanced users

Freeze barometer to last recorded altitude

SIM_BAR3_GLITCH: Barometer glitch

Note: This parameter is for advanced users

Barometer glitch height in SITL

Units

meters

SIM_BAR3_RND: Barometer noise

Note: This parameter is for advanced users

Barometer noise in height

Units

meters

SIM_BAR3_WCF_BAK: Wind coefficient backward

Note: This parameter is for advanced users

Barometer wind coefficient direction backward in SITL

SIM_BAR3_WCF_DN: Wind coefficient down

Note: This parameter is for advanced users

Barometer wind coefficient direction down in SITL

SIM_BAR3_WCF_FWD: Wind coefficient forward

Note: This parameter is for advanced users

Barometer wind coefficient direction forward in SITL

SIM_BAR3_WCF_LFT: Wind coefficient left

Note: This parameter is for advanced users

Barometer wind coefficient direction left in SITL

SIM_BAR3_WCF_RGT: Wind coefficient right

Note: This parameter is for advanced users

Barometer wind coefficient direction right in SITL

SIM_BAR3_WCF_UP: Wind coefficient up

Note: This parameter is for advanced users

Barometer wind coefficient direction up in SITL

SIM_BARO_COUNT: Baro count

Number of simulated baros to create in SITL

Range

0 to 3

SIM_BARO_DELAY: Barometer delay

Note: This parameter is for advanced users

Barometer data time delay

Units

milliseconds

SIM_BARO_DISABLE: Barometer disable

Note: This parameter is for advanced users

Disable barometer in SITL

Values

Value

Meaning

0

Disable

1

Enable

SIM_BARO_DRIFT: Barometer altitude drift

Note: This parameter is for advanced users

Barometer altitude drifts at this rate

Units

meters per second

SIM_BARO_FREEZE: Barometer freeze

Note: This parameter is for advanced users

Freeze barometer to last recorded altitude

SIM_BARO_GLITCH: Barometer glitch

Note: This parameter is for advanced users

Barometer glitch height in SITL

Units

meters

SIM_BARO_RND: Barometer noise

Note: This parameter is for advanced users

Barometer noise in height

Units

meters

SIM_BARO_WCF_BAK: Wind coefficient backward

Note: This parameter is for advanced users

Barometer wind coefficient direction backward in SITL

SIM_BARO_WCF_DN: Wind coefficient down

Note: This parameter is for advanced users

Barometer wind coefficient direction down in SITL

SIM_BARO_WCF_FWD: Wind coefficient forward

Note: This parameter is for advanced users

Barometer wind coefficient direction forward in SITL

SIM_BARO_WCF_LFT: Wind coefficient left

Note: This parameter is for advanced users

Barometer wind coefficient direction left in SITL

SIM_BARO_WCF_RGT: Wind coefficient right

Note: This parameter is for advanced users

Barometer wind coefficient direction right in SITL

SIM_BARO_WCF_UP: Wind coefficient up

Note: This parameter is for advanced users

Barometer wind coefficient direction up in SITL

SIM_BATT_CAP_AH: Simulated battery capacity

Note: This parameter is for advanced users

Simulated battery capacity

Units

ampere hour

SIM_BATT_VOLTAGE: Simulated battery voltage

Note: This parameter is for advanced users

Simulated battery (constant) voltage

Units

volt

SIM_BAUDLIMIT_EN: Telemetry bandwidth limitting

SITL enable bandwidth limitting on telemetry ports with non-zero values

SIM_CAN_SRV_MSK: Mask of CAN servos/ESCs

Note: This parameter is for advanced users

The set of actuators controlled externally by CAN SITL AP_Periph

Bitmask

Bit

Meaning

0

Servo 1

1

Servo 2

2

Servo 3

3

Servo 4

4

Servo 5

5

Servo 6

6

Servo 7

7

Servo 8

8

Servo 9

9

Servo 10

10

Servo 11

11

Servo 12

12

Servo 13

13

Servo 14

14

Servo 15

15

Servo 16

16

Servo 17

17

Servo 18

18

Servo 19

19

Servo 20

20

Servo 21

21

Servo 22

22

Servo 23

23

Servo 24

24

Servo 25

25

Servo 26

26

Servo 27

27

Servo 28

28

Servo 29

29

Servo 30

30

Servo 31

31

Servo 32

SIM_CAN_TYPE1: transport type for first CAN interface

Note: This parameter is for advanced users

transport type for first CAN interface

Values

Value

Meaning

0

None

1

MulticastUDP

2

SocketCAN

SIM_CAN_TYPE2: transport type for second CAN interface

Note: This parameter is for advanced users

transport type for second CAN interface

Values

Value

Meaning

0

None

1

MulticastUDP

2

SocketCAN

SIM_CLAMP_CH: Simulated Clamp Channel

If non-zero the vehicle will be clamped in position until the value on this servo channel passes 1800PWM

SIM_DRIFT_SPEED: Gyro drift speed

Gyro drift rate of change in degrees/second/minute

SIM_DRIFT_TIME: Gyro drift time

Gyro drift duration of one full drift cycle (period in minutes)

SIM_EFI_TYPE: Type of Electronic Fuel Injection

Different types of Electronic Fuel Injection (EFI) systems

Values

Value

Meaning

0

None

1

MegaSquirt EFI system

2

Löweheiser EFI system

8

Hirth engines

SIM_ENGINE_FAIL: Engine Fail Mask

mask of motors which SIM_ENGINE_MUL will be applied to

Bitmask

Bit

Meaning

0

Servo 1

1

Servo 2

2

Servo 3

3

Servo 4

4

Servo 5

5

Servo 6

6

Servo 7

7

Servo 8

SIM_ENGINE_MUL: Engine failure thrust scaler

Thrust from Motors in SIM_ENGINE_FAIL will be multiplied by this factor

Units

milliseconds

SIM_ESC_ARM_RPM: ESC RPM when armed

Note: This parameter is for advanced users

Simulated RPM when motors are armed

SIM_ESC_TELEM: Simulated ESC Telemetry

Note: This parameter is for advanced users

enable perfect simulated ESC telemetry

SIM_FLOAT_EXCEPT: Generate floating point exceptions

Note: This parameter is for advanced users

If set, if a numerical error occurs SITL will die with a floating point exception.

SIM_FLOW_DELAY: Opflow Delay

Opflow data delay

Units

milliseconds

SIM_FLOW_ENABLE: Opflow Enable

Enable simulated Optical Flow sensor

Values

Value

Meaning

0

Disable

1

Enabled

SIM_FLOW_POS_X: Opflow Pos

XYZ position of the optical flow sensor focal point relative to the body frame origin (X-axis)

Units

meters

SIM_FLOW_POS_Y: Opflow Pos

XYZ position of the optical flow sensor focal point relative to the body frame origin (Y-axis)

Units

meters

SIM_FLOW_POS_Z: Opflow Pos

XYZ position of the optical flow sensor focal point relative to the body frame origin (Z-axis)

Units

meters

SIM_FLOW_RATE: Opflow Rate

Opflow Data Rate

Units

hertz

SIM_FLOW_RND: Opflow noise

Optical Flow sensor measurement noise

Units

radians per second

SIM_GLD_BLN_BRST: balloon burst height

balloon burst height

Units

meters

SIM_GLD_BLN_RATE: balloon climb rate

balloon climb rate

Units

meters per second

SIM_GND_BEHAV: Ground behavior

Ground behavior of aircraft (tailsitter, no movement, forward only)

SIM_GPS1_ACC: GPS Accuracy

Note: This parameter is for advanced users

GPS Accuracy

SIM_GPS1_ALT_OFS: GPS Altitude Offset

GPS Altitude Error

Units

meters

SIM_GPS1_BYTELOS: GPS Byteloss

Note: This parameter is for advanced users

Percent of bytes lost from GPS

Units

percent

SIM_GPS1_DRFTALT: GPS Altitude Drift

Note: This parameter is for advanced users

GPS altitude drift error

Units

meters

SIM_GPS1_ENABLE: GPS enable

Note: This parameter is for advanced users

Enable simulated GPS

Values

Value

Meaning

0

Disable

1

Enable

SIM_GPS1_GLTCH_X: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (X-axis)

SIM_GPS1_GLTCH_Y: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (Y-axis)

SIM_GPS1_GLTCH_Z: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (Z-axis)

SIM_GPS1_HDG: GPS Heading

Note: This parameter is for advanced users

Enable GPS output of NMEA heading HDT sentence or UBLOX_RELPOSNED

Values

Value

Meaning

0

Disabled

1

Emit HDT

2

Emit THS

3

KSXT

4

Be Moving Baseline Base

SIM_GPS1_HZ: GPS Hz

GPS Update rate

Units

hertz

SIM_GPS1_JAM: GPS jamming enable

Note: This parameter is for advanced users

Enable simulated GPS jamming

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_GPS1_LAG_MS: GPS Lag

Note: This parameter is for advanced users

GPS lag

Units

milliseconds

SIM_GPS1_LCKTIME: GPS Lock Time

Note: This parameter is for advanced users

Delay in seconds before GPS acquires lock

Units

seconds

SIM_GPS1_NOISE: GPS Noise

Note: This parameter is for advanced users

Amplitude of the GPS altitude error

Units

meters

SIM_GPS1_NUMSATS: GPS Num Satellites

Number of satellites GPS has in view

SIM_GPS1_POS_X: GPS Position

GPS antenna phase center position relative to the body frame origin (X-axis)

Units

meters

SIM_GPS1_POS_Y: GPS Position

GPS antenna phase center position relative to the body frame origin (Y-axis)

Units

meters

SIM_GPS1_POS_Z: GPS Position

GPS antenna phase center position relative to the body frame origin (Z-axis)

Units

meters

SIM_GPS1_TYPE: GPS type

Note: This parameter is for advanced users

Sets the type of simulation used for GPS

Values

Value

Meaning

0

None

1

UBlox

5

NMEA

6

SBP

7

File

8

Nova

9

SBP2

11

Trimble

19

MSP

SIM_GPS1_VERR_X: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (X-axis)

SIM_GPS1_VERR_Y: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (Y-axis)

SIM_GPS1_VERR_Z: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (Z-axis)

SIM_GPS2_ACC: GPS Accuracy

Note: This parameter is for advanced users

GPS Accuracy

SIM_GPS2_ALT_OFS: GPS Altitude Offset

GPS Altitude Error

Units

meters

SIM_GPS2_BYTELOS: GPS Byteloss

Note: This parameter is for advanced users

Percent of bytes lost from GPS

Units

percent

SIM_GPS2_DRFTALT: GPS Altitude Drift

Note: This parameter is for advanced users

GPS altitude drift error

Units

meters

SIM_GPS2_ENABLE: GPS enable

Note: This parameter is for advanced users

Enable simulated GPS

Values

Value

Meaning

0

Disable

1

Enable

SIM_GPS2_GLTCH_X: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (X-axis)

SIM_GPS2_GLTCH_Y: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (Y-axis)

SIM_GPS2_GLTCH_Z: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (Z-axis)

SIM_GPS2_HDG: GPS Heading

Note: This parameter is for advanced users

Enable GPS output of NMEA heading HDT sentence or UBLOX_RELPOSNED

Values

Value

Meaning

0

Disabled

1

Emit HDT

2

Emit THS

3

KSXT

4

Be Moving Baseline Base

SIM_GPS2_HZ: GPS Hz

GPS Update rate

Units

hertz

SIM_GPS2_JAM: GPS jamming enable

Note: This parameter is for advanced users

Enable simulated GPS jamming

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_GPS2_LAG_MS: GPS Lag

Note: This parameter is for advanced users

GPS lag

Units

milliseconds

SIM_GPS2_LCKTIME: GPS Lock Time

Note: This parameter is for advanced users

Delay in seconds before GPS acquires lock

Units

seconds

SIM_GPS2_NOISE: GPS Noise

Note: This parameter is for advanced users

Amplitude of the GPS altitude error

Units

meters

SIM_GPS2_NUMSATS: GPS Num Satellites

Number of satellites GPS has in view

SIM_GPS2_POS_X: GPS Position

GPS antenna phase center position relative to the body frame origin (X-axis)

Units

meters

SIM_GPS2_POS_Y: GPS Position

GPS antenna phase center position relative to the body frame origin (Y-axis)

Units

meters

SIM_GPS2_POS_Z: GPS Position

GPS antenna phase center position relative to the body frame origin (Z-axis)

Units

meters

SIM_GPS2_TYPE: GPS type

Note: This parameter is for advanced users

Sets the type of simulation used for GPS

Values

Value

Meaning

0

None

1

UBlox

5

NMEA

6

SBP

7

File

8

Nova

9

SBP2

11

Trimble

19

MSP

SIM_GPS2_VERR_X: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (X-axis)

SIM_GPS2_VERR_Y: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (Y-axis)

SIM_GPS2_VERR_Z: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (Z-axis)

SIM_GPS3_ACC: GPS Accuracy

Note: This parameter is for advanced users

GPS Accuracy

SIM_GPS3_ALT_OFS: GPS Altitude Offset

GPS Altitude Error

Units

meters

SIM_GPS3_BYTELOS: GPS Byteloss

Note: This parameter is for advanced users

Percent of bytes lost from GPS

Units

percent

SIM_GPS3_DRFTALT: GPS Altitude Drift

Note: This parameter is for advanced users

GPS altitude drift error

Units

meters

SIM_GPS3_ENABLE: GPS enable

Note: This parameter is for advanced users

Enable simulated GPS

Values

Value

Meaning

0

Disable

1

Enable

SIM_GPS3_GLTCH_X: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (X-axis)

SIM_GPS3_GLTCH_Y: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (Y-axis)

SIM_GPS3_GLTCH_Z: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (Z-axis)

SIM_GPS3_HDG: GPS Heading

Note: This parameter is for advanced users

Enable GPS output of NMEA heading HDT sentence or UBLOX_RELPOSNED

Values

Value

Meaning

0

Disabled

1

Emit HDT

2

Emit THS

3

KSXT

4

Be Moving Baseline Base

SIM_GPS3_HZ: GPS Hz

GPS Update rate

Units

hertz

SIM_GPS3_JAM: GPS jamming enable

Note: This parameter is for advanced users

Enable simulated GPS jamming

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_GPS3_LAG_MS: GPS Lag

Note: This parameter is for advanced users

GPS lag

Units

milliseconds

SIM_GPS3_LCKTIME: GPS Lock Time

Note: This parameter is for advanced users

Delay in seconds before GPS acquires lock

Units

seconds

SIM_GPS3_NOISE: GPS Noise

Note: This parameter is for advanced users

Amplitude of the GPS altitude error

Units

meters

SIM_GPS3_NUMSATS: GPS Num Satellites

Number of satellites GPS has in view

SIM_GPS3_POS_X: GPS Position

GPS antenna phase center position relative to the body frame origin (X-axis)

Units

meters

SIM_GPS3_POS_Y: GPS Position

GPS antenna phase center position relative to the body frame origin (Y-axis)

Units

meters

SIM_GPS3_POS_Z: GPS Position

GPS antenna phase center position relative to the body frame origin (Z-axis)

Units

meters

SIM_GPS3_TYPE: GPS type

Note: This parameter is for advanced users

Sets the type of simulation used for GPS

Values

Value

Meaning

0

None

1

UBlox

5

NMEA

6

SBP

7

File

8

Nova

9

SBP2

11

Trimble

19

MSP

SIM_GPS3_VERR_X: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (X-axis)

SIM_GPS3_VERR_Y: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (Y-axis)

SIM_GPS3_VERR_Z: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (Z-axis)

SIM_GPS4_ACC: GPS Accuracy

Note: This parameter is for advanced users

GPS Accuracy

SIM_GPS4_ALT_OFS: GPS Altitude Offset

GPS Altitude Error

Units

meters

SIM_GPS4_BYTELOS: GPS Byteloss

Note: This parameter is for advanced users

Percent of bytes lost from GPS

Units

percent

SIM_GPS4_DRFTALT: GPS Altitude Drift

Note: This parameter is for advanced users

GPS altitude drift error

Units

meters

SIM_GPS4_ENABLE: GPS enable

Note: This parameter is for advanced users

Enable simulated GPS

Values

Value

Meaning

0

Disable

1

Enable

SIM_GPS4_GLTCH_X: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (X-axis)

SIM_GPS4_GLTCH_Y: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (Y-axis)

SIM_GPS4_GLTCH_Z: GPS Glitch

Note: This parameter is for advanced users

Glitch offsets of simulated GPS sensor (Z-axis)

SIM_GPS4_HDG: GPS Heading

Note: This parameter is for advanced users

Enable GPS output of NMEA heading HDT sentence or UBLOX_RELPOSNED

Values

Value

Meaning

0

Disabled

1

Emit HDT

2

Emit THS

3

KSXT

4

Be Moving Baseline Base

SIM_GPS4_HZ: GPS Hz

GPS Update rate

Units

hertz

SIM_GPS4_JAM: GPS jamming enable

Note: This parameter is for advanced users

Enable simulated GPS jamming

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_GPS4_LAG_MS: GPS Lag

Note: This parameter is for advanced users

GPS lag

Units

milliseconds

SIM_GPS4_LCKTIME: GPS Lock Time

Note: This parameter is for advanced users

Delay in seconds before GPS acquires lock

Units

seconds

SIM_GPS4_NOISE: GPS Noise

Note: This parameter is for advanced users

Amplitude of the GPS altitude error

Units

meters

SIM_GPS4_NUMSATS: GPS Num Satellites

Number of satellites GPS has in view

SIM_GPS4_POS_X: GPS Position

GPS antenna phase center position relative to the body frame origin (X-axis)

Units

meters

SIM_GPS4_POS_Y: GPS Position

GPS antenna phase center position relative to the body frame origin (Y-axis)

Units

meters

SIM_GPS4_POS_Z: GPS Position

GPS antenna phase center position relative to the body frame origin (Z-axis)

Units

meters

SIM_GPS4_TYPE: GPS type

Note: This parameter is for advanced users

Sets the type of simulation used for GPS

Values

Value

Meaning

0

None

1

UBlox

5

NMEA

6

SBP

7

File

8

Nova

9

SBP2

11

Trimble

19

MSP

SIM_GPS4_VERR_X: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (X-axis)

SIM_GPS4_VERR_Y: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (Y-axis)

SIM_GPS4_VERR_Z: GPS Velocity Error

Note: This parameter is for advanced users

GPS Velocity Error Offsets in NED (Z-axis)

SIM_GPS_LOG_NUM: GPS Log Number

Log number for GPS:update_file()

SIM_GRPE_ENABLE: Gripper servo Sim enable/disable

Note: This parameter is for advanced users

Allows you to enable (1) or disable (0) the gripper servo simulation

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_GRPE_PIN: Gripper emp pin

Note: This parameter is for advanced users

The pin number that the gripper emp is connected to. (start at 1)

Range

0 to 15

SIM_GRPS_ENABLE: Gripper servo Sim enable/disable

Note: This parameter is for advanced users

Allows you to enable (1) or disable (0) the gripper servo simulation

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_GRPS_GRAB: Gripper Grab PWM

Note: This parameter is for advanced users

PWM value in microseconds sent to Gripper to initiate grabbing the cargo

Range

Units

1000 to 2000

PWM in microseconds

SIM_GRPS_PIN: Gripper servo pin

Note: This parameter is for advanced users

The pin number that the gripper servo is connected to. (start at 1)

Range

0 to 15

SIM_GRPS_RELEASE: Gripper Release PWM

Note: This parameter is for advanced users

PWM value in microseconds sent to Gripper to release the cargo

Range

Units

1000 to 2000

PWM in microseconds

SIM_GRPS_REVERSE: Gripper close direction

Note: This parameter is for advanced users

Reverse the closing direction.

Values

Value

Meaning

0

Normal

1

Reverse

SIM_GYR1_BIAS_X: First Gyro bias on X axis

Note: This parameter is for advanced users

First Gyro bias on X axis

Units

radians per second

SIM_GYR1_BIAS_Y: First Gyro bias on Y axis

Note: This parameter is for advanced users

First Gyro bias on Y axis

Units

radians per second

SIM_GYR1_BIAS_Z: First Gyro bias on Z axis

Note: This parameter is for advanced users

First Gyro bias on Z axis

Units

radians per second

SIM_GYR1_RND: Gyro 1 motor noise factor

Note: This parameter is for advanced users

scaling factor for simulated vibration from motors

SIM_GYR1_SCALE_X: Gyro 1 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (X-axis)

SIM_GYR1_SCALE_Y: Gyro 1 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (Y-axis)

SIM_GYR1_SCALE_Z: Gyro 1 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (Z-axis)

SIM_GYR2_BIAS_X: Second Gyro bias on X axis

Note: This parameter is for advanced users

Second Gyro bias on X axis

Units

radians per second

SIM_GYR2_BIAS_Y: Second Gyro bias on Y axis

Note: This parameter is for advanced users

Second Gyro bias on Y axis

Units

radians per second

SIM_GYR2_BIAS_Z: Second Gyro bias on Z axis

Note: This parameter is for advanced users

Second Gyro bias on Z axis

Units

radians per second

SIM_GYR2_RND: Gyro 2 motor noise factor

Note: This parameter is for advanced users

scaling factor for simulated vibration from motors

SIM_GYR2_SCALE_X: Gyro 2 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (X-axis)

SIM_GYR2_SCALE_Y: Gyro 2 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (Y-axis)

SIM_GYR2_SCALE_Z: Gyro 2 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (Z-axis)

SIM_GYR3_BIAS_X: Third Gyro bias on X axis

Note: This parameter is for advanced users

Third Gyro bias on X axis

Units

radians per second

SIM_GYR3_BIAS_Y: Third Gyro bias on Y axis

Note: This parameter is for advanced users

Third Gyro bias on Y axis

Units

radians per second

SIM_GYR3_BIAS_Z: Third Gyro bias on Z axis

Note: This parameter is for advanced users

Third Gyro bias on Z axis

Units

radians per second

SIM_GYR3_RND: Gyro 3 motor noise factor

Note: This parameter is for advanced users

scaling factor for simulated vibration from motors

SIM_GYR3_SCALE_X: Gyro 3 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (X-axis)

SIM_GYR3_SCALE_Y: Gyro 3 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (Y-axis)

SIM_GYR3_SCALE_Z: Gyro 3 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (Z-axis)

SIM_GYR4_BIAS_X: Fourth Gyro bias on X axis

Note: This parameter is for advanced users

Fourth Gyro bias on X axis

Units

radians per second

SIM_GYR4_BIAS_Y: Fourth Gyro bias on Y axis

Note: This parameter is for advanced users

Fourth Gyro bias on Y axis

Units

radians per second

SIM_GYR4_BIAS_Z: Fourth Gyro bias on Z axis

Note: This parameter is for advanced users

Fourth Gyro bias on Z axis

Units

radians per second

SIM_GYR4_RND: Gyro 4 motor noise factor

Note: This parameter is for advanced users

scaling factor for simulated vibration from motors

SIM_GYR4_SCALE_X: Gyro 4 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (X-axis)

SIM_GYR4_SCALE_Y: Gyro 4 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (Y-axis)

SIM_GYR4_SCALE_Z: Gyro 4 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (Z-axis)

SIM_GYR5_BIAS_X: Fifth Gyro bias on X axis

Note: This parameter is for advanced users

Fifth Gyro bias on X axis

Units

radians per second

SIM_GYR5_BIAS_Y: Fifth Gyro bias on Y axis

Note: This parameter is for advanced users

Fifth Gyro bias on Y axis

Units

radians per second

SIM_GYR5_BIAS_Z: Fifth Gyro bias on Z axis

Note: This parameter is for advanced users

Fifth Gyro bias on Z axis

Units

radians per second

SIM_GYR5_RND: Gyro 5 motor noise factor

Note: This parameter is for advanced users

scaling factor for simulated vibration from motors

SIM_GYR5_SCALE_X: Gyro 5 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (X-axis)

SIM_GYR5_SCALE_Y: Gyro 5 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (Y-axis)

SIM_GYR5_SCALE_Z: Gyro 5 scaling factor

Note: This parameter is for advanced users

scaling factors applied to simulated gyroscope (Z-axis)

SIM_GYR_FAIL_MSK: Gyro Failure Mask

Note: This parameter is for advanced users

Determines if the gyro reading updates are stopped when for an IMU simulated failure by ACCELx_FAIL params

Values

Value

Meaning

0

Disabled

1

Readings stopped

SIM_GYR_FILE_RW: Gyro data to/from files

Read and write gyro data to/from files

Values

Value

Meaning

0

Stop writing data

1

Read data from file

2

Write data to a file

3

Read data from file and stop on EOF

SIM_IMUT_END: IMU temperature end

Ending IMU temperature of a curve

SIM_IMUT_FIXED: IMU fixed temperature

IMU fixed temperature by user

SIM_IMUT_START: IMU temperature start

Starting IMU temperature of a curve

SIM_IMUT_TCONST: IMU temperature time constant

IMU temperature time constant of the curve

SIM_IMU_COUNT: IMU count

Number of simulated IMUs to create

SIM_IMU_POS_X: IMU Offsets

XYZ position of the IMU accelerometer relative to the body frame origin (X-axis)

Units

meters

SIM_IMU_POS_Y: IMU Offsets

XYZ position of the IMU accelerometer relative to the body frame origin (Y-axis)

Units

meters

SIM_IMU_POS_Z: IMU Offsets

XYZ position of the IMU accelerometer relative to the body frame origin (Z-axis)

Units

meters

SIM_INIT_ALT_OFS: Initial Altitude Offset

GPS initial alt offset from origin

SIM_INIT_LAT_OFS: Initial Latitude Offset

GPS initial lat offset from origin

SIM_INIT_LON_OFS: Initial Longitude Offset

GPS initial lon offset from origin

SIM_INS_THR_MIN: Minimum throttle INS noise

Minimum throttle for simulated ins noise

SIM_JSON_MASTER: JSON master instance

the instance number to take servos from

SIM_LED_LAYOUT: LED layout

LED layout config value

SIM_LOOP_DELAY: Extra delay per main loop

Extra time delay per main loop

Units

microseconds

SIM_MAG1_DEVID: MAG1 Device ID

Note: This parameter is for advanced users

Device ID of simulated compass 1

SIM_MAG1_FAIL: MAG1 Failure

Note: This parameter is for advanced users

Simulated failure of MAG1

Values

Value

Meaning

0

Disabled

1

MAG1 Failure

SIM_MAG1_ORIENT: MAG1 Orientation

Note: This parameter is for advanced users

MAG1 external compass orientation

SIM_MAG1_SCALING: MAG1 Scaling factor

Note: This parameter is for advanced users

Scale the compass 1 to simulate sensor scale factor errors

SIM_MAG2_DEVID: MAG2 Device ID

Note: This parameter is for advanced users

Device ID of simulated compass 2

SIM_MAG2_FAIL: MAG2 Failure

Note: This parameter is for advanced users

Simulated failure of MAG2

Values

Value

Meaning

0

Disabled

1

MAG2 Failure

SIM_MAG2_ORIENT: MAG2 Orientation

Note: This parameter is for advanced users

MAG2 external compass orientation

SIM_MAG2_SCALING: MAG2 Scaling factor

Note: This parameter is for advanced users

Scale the compass 2 to simulate sensor scale factor errors

SIM_MAG3_DEVID: MAG3 Device ID

Note: This parameter is for advanced users

Device ID of simulated compass 3

SIM_MAG3_FAIL: MAG3 Failure

Note: This parameter is for advanced users

Simulated failure of MAG3

Values

Value

Meaning

0

Disabled

1

MAG3 Failure

SIM_MAG3_ORIENT: MAG3 Orientation

Note: This parameter is for advanced users

MAG3 external compass orientation

SIM_MAG3_SCALING: MAG3 Scaling factor

Note: This parameter is for advanced users

Scale the compass 3 to simulate sensor scale factor errors

SIM_MAG4_DEVID: MAG2 Device ID

Note: This parameter is for advanced users

Device ID of simulated compass 4

SIM_MAG5_DEVID: MAG5 Device ID

Note: This parameter is for advanced users

Device ID of simulated compass 5

SIM_MAG6_DEVID: MAG6 Device ID

Note: This parameter is for advanced users

Device ID of simulated compass 6

SIM_MAG7_DEVID: MAG7 Device ID

Note: This parameter is for advanced users

Device ID of simulated compass 7

SIM_MAG8_DEVID: MAG8 Device ID

Note: This parameter is for advanced users

Device ID of simulated compass 8

SIM_MAG_ALY_HGT: Magnetic anomaly height

Note: This parameter is for advanced users

Height above ground where anomally strength has decayed to 1/8 of the ground level value

Units

meters

SIM_MAG_DELAY: Mag measurement delay

Note: This parameter is for advanced users

Magnetometer measurement delay

Units

milliseconds

SIM_MAG_RND: Mag motor noise factor

Note: This parameter is for advanced users

Scaling factor for simulated vibration from motors

SIM_MAG_SAVE_IDS: Save MAG devids on startup

Note: This parameter is for advanced users

This forces saving of compass devids on startup so that simulated compasses start as calibrated

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_ODOM_ENABLE: Odometry enable

SITL odometry enabl

Values

Value

Meaning

0

Disable

1

Enable

SIM_OH_MASK: SIM-on_hardware Output Enable Mask

channels which are passed through to actual hardware when running sim on actual hardware

SIM_OH_RELAY_MSK: SIM-on_hardware Relay Enable Mask

Allow relay output operation when running SIM-on-hardware

SIM_OPOS_ALT: Original Position (Altitude)

Note: This parameter is for advanced users

Specifies vehicle's startup altitude (AMSL)

SIM_OPOS_HDG: Original Position (Heading)

Note: This parameter is for advanced users

Specifies vehicle's startup heading (0-360)

SIM_OPOS_LAT: Original Position (Latitude)

Note: This parameter is for advanced users

Specifies vehicle's startup latitude

SIM_OPOS_LNG: Original Position (Longitude)

Note: This parameter is for advanced users

Specifies vehicle's startup longitude

SIM_OSD_COLUMNS: Simulated OSD number of text columns

Simulated OSD number of text columns

Range

10 to 100

SIM_OSD_ROWS: Simulated OSD number of text rows

Simulated OSD number of text rows

Range

10 to 100

SIM_PIN_MASK: GPIO emulation

SITL GPIO emulation

SIM_PLD_ALT_LMT: Precland device alt range

Note: This parameter is for advanced users

Precland device maximum range altitude

Range

Units

0 to 100

meters

SIM_PLD_DIST_LMT: Precland device lateral range

Note: This parameter is for advanced users

Precland device maximum lateral range

Range

Units

5 to 100

meters

SIM_PLD_ENABLE: Preland device Sim enable/disable

Note: This parameter is for advanced users

Allows you to enable (1) or disable (0) the Preland simulation

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_PLD_HEIGHT: Precland device center's height SITL origin

Note: This parameter is for advanced users

Precland device center's height above SITL origin. Assumes a 2x2m square as station base

Increment

Range

Units

1

0 to 10000

meters

SIM_PLD_LAT: Precland device center's latitude

Note: This parameter is for advanced users

Precland device center's latitude

Increment

Range

Units

0.000001

-90 to 90

degrees

SIM_PLD_LON: Precland device center's longitude

Note: This parameter is for advanced users

Precland device center's longitude

Increment

Range

Units

0.000001

-180 to 180

degrees

SIM_PLD_OPTIONS: SIM_Precland extra options

Note: This parameter is for advanced users

SIM_Precland extra options

Bitmask

Bit

Meaning

0

Enable target distance

SIM_PLD_ORIENT: Precland device orientation

Note: This parameter is for advanced users

Precland device orientation vector

Values

Value

Meaning

0

Front

4

Back

24

Up

SIM_PLD_RATE: Precland device update rate

Note: This parameter is for advanced users

Precland device rate. e.g led patter refresh rate, RF message rate, etc.

Range

Units

0 to 200

hertz

SIM_PLD_SHIP: SIM_Precland follow ship

Note: This parameter is for advanced users

This makes the position of the landing beacon follow the simulated ship from SIM_SHIP. The ship movement is controlled with the SIM_SHIP parameters

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_PLD_TYPE: Precland device radiance type

Note: This parameter is for advanced users

Precland device radiance type: it can be a cylinder, a cone, or a sphere.

Values

Value

Meaning

0

cylinder

1

cone

2

sphere

SIM_PLD_YAW: Precland device systems rotation from north

Note: This parameter is for advanced users

Precland device systems rotation from north

Increment

Range

Units

1

-180 to +180

degrees

SIM_RATE_HZ: Loop rate

SITL Loop rate

Units

hertz

SIM_RC_CHANCOUNT: RC channel count

SITL RC channel count

SIM_RC_FAIL: Simulated RC signal failure

Note: This parameter is for advanced users

Allows you to emulate rc failures in sim

Values

Value

Meaning

0

Disabled

1

No RC pusles

2

All Channels neutral except Throttle is 950us

SIM_RFL_OPTS: FlightAxis options

Note: This parameter is for advanced users

Bitmask of FlightAxis options

Bitmask

Bit

Meaning

0

Reset position on startup

1

Swap first 4 and last 4 servos (for quadplane testing)

2

Demix heli servos and send roll/pitch/collective/yaw

3

Don’t print frame rate stats

SIM_SB_ALT_TARG: altitude target

altitude target

Units

meters

SIM_SB_ARM_LEN: arm length

distance from center of mass to one motor

Units

meters

SIM_SB_CLMB_RT: target climb rate

target climb rate

Units

meters per second

SIM_SB_COL: center of lift

center of lift position above CoG

Units

meters

SIM_SB_DRAG_FWD: drag in forward direction

drag on X axis

SIM_SB_DRAG_SIDE: drag in sidewards direction

drag on Y axis

SIM_SB_DRAG_UP: drag in upward direction

drag on Z axis

SIM_SB_FLR: free lift rate

amount of additional lift generated by the helper balloon (for the purpose of ascent), as a proportion of the 'neutral buoyancy' lift

SIM_SB_HMASS: helium mass

mass of lifting gas

Units

kilograms

SIM_SB_MASS: mass

mass of blimp not including lifting gas

Units

kilograms

SIM_SB_MOI_PITCH: moment of inertia in pitch

moment of inertia in pitch

SIM_SB_MOI_ROLL: moment of inertia in roll

moment of inertia in roll

SIM_SB_MOI_YAW: moment of inertia in yaw

moment of inertia in yaw

SIM_SB_MOT_ANG: motor angle

maximum motor tilt angle

Units

degrees

SIM_SB_MOT_THST: motor thrust

thrust at max throttle for one motor

Units

Newtons

SIM_SB_WVANE: weathervaning offset

center of drag for weathervaning

Units

meters

SIM_SB_YAW_RT: yaw rate

maximum yaw rate with full left throttle at target altitude

Units

degrees per second

SIM_SERVO_DELAY: servo delay

servo delay

Units

seconds

SIM_SERVO_FILTER: servo filter

servo filter

Units

hertz

SIM_SERVO_SPEED: servo speed

servo speed (time for 60 degree deflection). If DELAY and FILTER are not set then this is converted to a 1p lowpass filter. If DELAY or FILTER are set then this is treated as a rate of change limit

Units

seconds

SIM_SHOVE_TIME: Time length for shove

Force to the vehicle over a period of time

Units

milliseconds

SIM_SHOVE_X: Acceleration of shove x

Acceleration of shove to vehicle in x axis

Units

meters per square second

SIM_SHOVE_Y: Acceleration of shove y

Acceleration of shove to vehicle in y axis

Units

meters per square second

SIM_SHOVE_Z: Acceleration of shove z

Acceleration of shove to vehicle in z axis

Units

meters per square second

SIM_SLUP_DRAG: Slung Payload drag coefficient

Note: This parameter is for advanced users

Slung Payload drag coefficient. Higher values increase drag and slow the payload more quickly

Range

Units

0 to 10

meters

SIM_SLUP_ENABLE: Slung Payload Sim enable/disable

Note: This parameter is for advanced users

Slung Payload Sim enable/disable

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_SLUP_LINELEN: Slung Payload line length

Note: This parameter is for advanced users

Slung Payload line length in meters

Range

Units

0 to 100

meters

SIM_SLUP_WEIGHT: Slung Payload weight

Note: This parameter is for advanced users

Slung Payload weight in kg

Range

Units

0 to 15

kilograms

SIM_SONAR_GLITCH: Sonar glitch probablility

Note: This parameter is for advanced users

Probablility a sonar glitch would happen

Range

0 to 1

SIM_SONAR_RND: Sonar noise factor

Note: This parameter is for advanced users

Scaling factor for simulated sonar noise

SIM_SONAR_ROT: Sonar rotation

Sonar rotation from rotations enumeration

SIM_SONAR_SCALE: Sonar conversion scale

Sonar conversion scale from distance to voltage

Units

meters per volt

SIM_SPEEDUP: Sim Speedup

Runs the simulation at multiples of normal speed. Do not use if realtime physics, like RealFlight, is being used

Range

1 to 10

SIM_SPR_ENABLE: Sprayer Sim enable/disable

Note: This parameter is for advanced users

Allows you to enable (1) or disable (0) the Sprayer simulation

Values

Value

Meaning

0

Disabled

1

Enabled

SIM_SPR_PUMP: Sprayer pump pin

Note: This parameter is for advanced users

The pin number that the Sprayer pump is connected to. (start at 1)

Range

0 to 15

SIM_SPR_SPIN: Sprayer spinner servo pin

Note: This parameter is for advanced users

The pin number that the Sprayer spinner servo is connected to. (start at 1)

Range

0 to 15

SIM_TEMP_BFACTOR: Baro temperature factor

Note: This parameter is for advanced users

A pressure change with temperature that closely matches what has been observed with a ICM-20789

SIM_TEMP_BRD_OFF: Baro temperature offset

Note: This parameter is for advanced users

Barometer board temperature offset from atmospheric temperature

Units

degrees Celsius

SIM_TEMP_START: Start temperature

Note: This parameter is for advanced users

Baro start temperature

Units

degrees Celsius

SIM_TEMP_TCONST: Warmup time constant

Note: This parameter is for advanced users

Barometer warmup temperature time constant

Units

degrees Celsius

SIM_TERRAIN: Terrain Enable

Enable using terrain for height

Values

Value

Meaning

0

Disable

1

Enabled

SIM_THML_SCENARI: Thermal scenarios

Scenario for thermalling simulation, for soaring

SIM_TIDE_DIR: Tide direction

Tide direction wave is coming from

Units

degrees

SIM_TIDE_SPEED: Tide speed

Tide speed in simulation

Units

meters per second

SIM_TIME_JITTER: Loop time jitter

Note: This parameter is for advanced users

Upper limit of random jitter in loop time

Units

microseconds

SIM_TWIST_TIME: Twist time

Time that twist is applied on the vehicle

Units

milliseconds

SIM_TWIST_X: Twist x

Rotational acceleration of twist x axis

Units

radians per square second

SIM_TWIST_Y: Twist y

Rotational acceleration of twist y axis

Units

radians per square second

SIM_TWIST_Z: Twist z

Rotational acceleration of twist z axis

Units

radians per square second

SIM_UART_LOSS: UART byte loss percentage

Note: This parameter is for advanced users

Sets percentage of outgoing byte loss on UARTs

Units

percent

SIM_VIB_MOT_HMNC: Motor harmonics

Motor harmonics generated in SITL

SIM_VIB_MOT_MASK: Motor mask

Motor mask, allowing external simulators to mark motors

SIM_VIB_MOT_MAX: Max motor vibration frequency

Max frequency to use as baseline for adding motor noise for the gyros and accels

Units

hertz

SIM_VIB_MOT_MULT: Vibration motor scale

Amplitude scaling of motor noise relative to gyro/accel noise

SIM_VICON_FAIL: SITL vicon failure

Note: This parameter is for advanced users

SITL vicon failure

Values

Value

Meaning

0

Vicon Healthy

1

Vicon Failed

SIM_VICON_GLIT_X: SITL vicon position glitch North

Note: This parameter is for advanced users

SITL vicon position glitch North

Units

meters

SIM_VICON_GLIT_Y: SITL vicon position glitch East

Note: This parameter is for advanced users

SITL vicon position glitch East

Units

meters

SIM_VICON_GLIT_Z: SITL vicon position glitch Down

Note: This parameter is for advanced users

SITL vicon position glitch Down

Units

meters

SIM_VICON_POS_X: SITL vicon position on vehicle in Forward direction

Note: This parameter is for advanced users

SITL vicon position on vehicle in Forward direction

Range

Units

0 to 10

meters

SIM_VICON_POS_Y: SITL vicon position on vehicle in Right direction

Note: This parameter is for advanced users

SITL vicon position on vehicle in Right direction

Range

Units

0 to 10

meters

SIM_VICON_POS_Z: SITL vicon position on vehicle in Down direction

SITL vicon position on vehicle in Down direction

Range

Units

0 to 10

meters

SIM_VICON_TMASK: SITL vicon type mask

Note: This parameter is for advanced users

SITL vicon messages sent

Bitmask

Bit

Meaning

0

VISION_POSITION_ESTIMATE

1

VISION_SPEED_ESTIMATE

2

VICON_POSITION_ESTIMATE

3

VISION_POSITION_DELTA

4

ODOMETRY

SIM_VICON_VGLI_X: SITL vicon velocity glitch North

Note: This parameter is for advanced users

SITL vicon velocity glitch North

Units

meters per second

SIM_VICON_VGLI_Y: SITL vicon velocity glitch East

Note: This parameter is for advanced users

SITL vicon velocity glitch East

Units

meters per second

SIM_VICON_VGLI_Z: SITL vicon velocity glitch Down

Note: This parameter is for advanced users

SITL vicon velocity glitch Down

Units

meters per second

SIM_VICON_YAW: SITL vicon yaw angle in earth frame

Note: This parameter is for advanced users

SITL vicon yaw angle in earth frame

Range

Units

0 to 360

degrees

SIM_VICON_YAWERR: SITL vicon yaw error

Note: This parameter is for advanced users

SITL vicon yaw added to reported yaw sent to vehicle

Range

Units

-180 to 180

degrees

SIM_WAVE_AMP: Wave amplitude

Wave amplitude in SITL

Units

meters

SIM_WAVE_DIR: Wave direction

Direction wave is coming from

Units

degrees

SIM_WAVE_ENABLE: Wave enable

Wave enable and modes

Values

Value

Meaning

0

disabled

1

roll and pitch

2

roll and pitch and heave

SIM_WAVE_LENGTH: Wave length

Wave length in SITL

Units

meters

SIM_WAVE_SPEED: Wave speed

Wave speed in SITL

Units

meters per second

SIM_WIND_DIR: Direction simulated wind is coming from

Note: This parameter is for advanced users

Allows you to set wind direction (true deg) in sim

Units

degrees

SIM_WIND_DIR_Z: Simulated wind vertical direction

Note: This parameter is for advanced users

Allows you to set vertical wind direction (true deg) in sim. 0 means pure horizontal wind. 90 means pure updraft.

Units

degrees

SIM_WIND_SPD: Simulated Wind speed

Note: This parameter is for advanced users

Allows you to emulate wind in sim

Units

meters per second

SIM_WIND_T: Wind Profile Type

Selects how wind varies from surface to WIND_T_ALT

Values

Value

Meaning

0

square law

1

none

2

linear-see WIND_T_COEF

SIM_WIND_TC: Wind variation time constant

Note: This parameter is for advanced users

this controls the time over which wind changes take effect

Units

seconds

SIM_WIND_TURB: Simulated Wind variation

Note: This parameter is for advanced users

Allows you to emulate random wind variations in sim

Units

meters per second

SIM_WIND_T_ALT: Full Wind Altitude

Note: This parameter is for advanced users

Altitude at which wind reaches full strength, decaying from full strength as altitude lowers to ground level

Units

meters

SIM_WIND_T_COEF: Linear Wind Curve Coeff

Note: This parameter is for advanced users

For linear wind profile,wind is reduced by (Altitude-WIND_T_ALT) x this value

SIM_WOW_PIN: Weight on Wheels Pin

Note: This parameter is for advanced users

SITL set this simulated pin to true if vehicle is on ground

SPRAY_ Parameters

SPRAY_ENABLE: Sprayer enable/disable

Allows you to enable (1) or disable (0) the sprayer

Values

Value

Meaning

0

Disabled

1

Enabled

SPRAY_PUMP_RATE: Pump speed

Desired pump speed when travelling 1m/s expressed as a percentage

Range

Units

0 to 100

percent

SPRAY_SPINNER: Spinner rotation speed

Spinner's rotation speed in PWM (a higher rate will disperse the spray over a wider area horizontally)

Range

Units

1000 to 2000

milliseconds

SPRAY_SPEED_MIN: Speed minimum

Speed minimum at which we will begin spraying

Range

Units

0 to 1000

centimeters per second

SPRAY_PUMP_MIN: Pump speed minimum

Minimum pump speed expressed as a percentage

Range

Units

0 to 100

percent

SR0_ Parameters

SR0_RAW_SENS: Raw sensor stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of RAW_IMU, SCALED_IMU2, SCALED_IMU3, SCALED_PRESSURE, SCALED_PRESSURE2, SCALED_PRESSURE3 and AIRSPEED

Increment

Range

Units

1

0 to 50

hertz

SR0_EXT_STAT: Extended status stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SYS_STATUS, POWER_STATUS, MCU_STATUS, MEMINFO, CURRENT_WAYPOINT, GPS_RAW_INT, GPS_RTK (if available), GPS2_RAW_INT (if available), GPS2_RTK (if available), NAV_CONTROLLER_OUTPUT, FENCE_STATUS, and GLOBAL_TARGET_POS_INT

Increment

Range

Units

1

0 to 50

hertz

SR0_RC_CHAN: RC Channel stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SERVO_OUTPUT_RAW and RC_CHANNELS

Increment

Range

Units

1

0 to 50

hertz

SR0_RAW_CTRL: Unused

Note: This parameter is for advanced users
Note: Reboot required after change

Unused

Increment

Range

Units

1

0 to 50

hertz

SR0_POSITION: Position stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of GLOBAL_POSITION_INT and LOCAL_POSITION_NED

Increment

Range

Units

1

0 to 50

hertz

SR0_EXTRA1: Extra data type 1 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of ATTITUDE, SIMSTATE (SIM only), AHRS2 and PID_TUNING

Increment

Range

1

0 to 50

SR0_EXTRA2: Extra data type 2 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of VFR_HUD

Increment

Range

Units

1

0 to 50

hertz

SR0_EXTRA3: Extra data type 3 stream rate

MAVLink Stream rate of AHRS, SYSTEM_TIME, WIND, RANGEFINDER, DISTANCE_SENSOR, TERRAIN_REQUEST, TERRAIN_REPORT, BATTERY_STATUS, GIMBAL_DEVICE_ATTITUDE_STATUS, OPTICAL_FLOW, MAG_CAL_REPORT, MAG_CAL_PROGRESS, EKF_STATUS_REPORT, VIBRATION, RPM, ESC TELEMETRY,GENERATOR_STATUS, and WINCH_STATUS

SR0_PARAMS: Parameter stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of PARAM_VALUE

Increment

Range

Units

1

0 to 50

hertz

SR0_ADSB: ADSB stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink ADSB stream rate

Increment

Range

Units

1

0 to 50

hertz

SR1_ Parameters

SR1_RAW_SENS: Raw sensor stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of RAW_IMU, SCALED_IMU2, SCALED_IMU3, SCALED_PRESSURE, SCALED_PRESSURE2, SCALED_PRESSURE3 and AIRSPEED

Increment

Range

Units

1

0 to 50

hertz

SR1_EXT_STAT: Extended status stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SYS_STATUS, POWER_STATUS, MCU_STATUS, MEMINFO, CURRENT_WAYPOINT, GPS_RAW_INT, GPS_RTK (if available), GPS2_RAW_INT (if available), GPS2_RTK (if available), NAV_CONTROLLER_OUTPUT, FENCE_STATUS, and GLOBAL_TARGET_POS_INT

Increment

Range

Units

1

0 to 50

hertz

SR1_RC_CHAN: RC Channel stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SERVO_OUTPUT_RAW and RC_CHANNELS

Increment

Range

Units

1

0 to 50

hertz

SR1_RAW_CTRL: Unused

Note: This parameter is for advanced users
Note: Reboot required after change

Unused

Increment

Range

Units

1

0 to 50

hertz

SR1_POSITION: Position stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of GLOBAL_POSITION_INT and LOCAL_POSITION_NED

Increment

Range

Units

1

0 to 50

hertz

SR1_EXTRA1: Extra data type 1 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of ATTITUDE, SIMSTATE (SIM only), AHRS2 and PID_TUNING

Increment

Range

1

0 to 50

SR1_EXTRA2: Extra data type 2 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of VFR_HUD

Increment

Range

Units

1

0 to 50

hertz

SR1_EXTRA3: Extra data type 3 stream rate

MAVLink Stream rate of AHRS, SYSTEM_TIME, WIND, RANGEFINDER, DISTANCE_SENSOR, TERRAIN_REQUEST, TERRAIN_REPORT, BATTERY_STATUS, GIMBAL_DEVICE_ATTITUDE_STATUS, OPTICAL_FLOW, MAG_CAL_REPORT, MAG_CAL_PROGRESS, EKF_STATUS_REPORT, VIBRATION, RPM, ESC TELEMETRY,GENERATOR_STATUS, and WINCH_STATUS

SR1_PARAMS: Parameter stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of PARAM_VALUE

Increment

Range

Units

1

0 to 50

hertz

SR1_ADSB: ADSB stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink ADSB stream rate

Increment

Range

Units

1

0 to 50

hertz

SR2_ Parameters

SR2_RAW_SENS: Raw sensor stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of RAW_IMU, SCALED_IMU2, SCALED_IMU3, SCALED_PRESSURE, SCALED_PRESSURE2, SCALED_PRESSURE3 and AIRSPEED

Increment

Range

Units

1

0 to 50

hertz

SR2_EXT_STAT: Extended status stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SYS_STATUS, POWER_STATUS, MCU_STATUS, MEMINFO, CURRENT_WAYPOINT, GPS_RAW_INT, GPS_RTK (if available), GPS2_RAW_INT (if available), GPS2_RTK (if available), NAV_CONTROLLER_OUTPUT, FENCE_STATUS, and GLOBAL_TARGET_POS_INT

Increment

Range

Units

1

0 to 50

hertz

SR2_RC_CHAN: RC Channel stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SERVO_OUTPUT_RAW and RC_CHANNELS

Increment

Range

Units

1

0 to 50

hertz

SR2_RAW_CTRL: Unused

Note: This parameter is for advanced users
Note: Reboot required after change

Unused

Increment

Range

Units

1

0 to 50

hertz

SR2_POSITION: Position stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of GLOBAL_POSITION_INT and LOCAL_POSITION_NED

Increment

Range

Units

1

0 to 50

hertz

SR2_EXTRA1: Extra data type 1 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of ATTITUDE, SIMSTATE (SIM only), AHRS2 and PID_TUNING

Increment

Range

1

0 to 50

SR2_EXTRA2: Extra data type 2 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of VFR_HUD

Increment

Range

Units

1

0 to 50

hertz

SR2_EXTRA3: Extra data type 3 stream rate

MAVLink Stream rate of AHRS, SYSTEM_TIME, WIND, RANGEFINDER, DISTANCE_SENSOR, TERRAIN_REQUEST, TERRAIN_REPORT, BATTERY_STATUS, GIMBAL_DEVICE_ATTITUDE_STATUS, OPTICAL_FLOW, MAG_CAL_REPORT, MAG_CAL_PROGRESS, EKF_STATUS_REPORT, VIBRATION, RPM, ESC TELEMETRY,GENERATOR_STATUS, and WINCH_STATUS

SR2_PARAMS: Parameter stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of PARAM_VALUE

Increment

Range

Units

1

0 to 50

hertz

SR2_ADSB: ADSB stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink ADSB stream rate

Increment

Range

Units

1

0 to 50

hertz

SR3_ Parameters

SR3_RAW_SENS: Raw sensor stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of RAW_IMU, SCALED_IMU2, SCALED_IMU3, SCALED_PRESSURE, SCALED_PRESSURE2, SCALED_PRESSURE3 and AIRSPEED

Increment

Range

Units

1

0 to 50

hertz

SR3_EXT_STAT: Extended status stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SYS_STATUS, POWER_STATUS, MCU_STATUS, MEMINFO, CURRENT_WAYPOINT, GPS_RAW_INT, GPS_RTK (if available), GPS2_RAW_INT (if available), GPS2_RTK (if available), NAV_CONTROLLER_OUTPUT, FENCE_STATUS, and GLOBAL_TARGET_POS_INT

Increment

Range

Units

1

0 to 50

hertz

SR3_RC_CHAN: RC Channel stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SERVO_OUTPUT_RAW and RC_CHANNELS

Increment

Range

Units

1

0 to 50

hertz

SR3_RAW_CTRL: Unused

Note: This parameter is for advanced users
Note: Reboot required after change

Unused

Increment

Range

Units

1

0 to 50

hertz

SR3_POSITION: Position stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of GLOBAL_POSITION_INT and LOCAL_POSITION_NED

Increment

Range

Units

1

0 to 50

hertz

SR3_EXTRA1: Extra data type 1 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of ATTITUDE, SIMSTATE (SIM only), AHRS2 and PID_TUNING

Increment

Range

1

0 to 50

SR3_EXTRA2: Extra data type 2 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of VFR_HUD

Increment

Range

Units

1

0 to 50

hertz

SR3_EXTRA3: Extra data type 3 stream rate

MAVLink Stream rate of AHRS, SYSTEM_TIME, WIND, RANGEFINDER, DISTANCE_SENSOR, TERRAIN_REQUEST, TERRAIN_REPORT, BATTERY_STATUS, GIMBAL_DEVICE_ATTITUDE_STATUS, OPTICAL_FLOW, MAG_CAL_REPORT, MAG_CAL_PROGRESS, EKF_STATUS_REPORT, VIBRATION, RPM, ESC TELEMETRY,GENERATOR_STATUS, and WINCH_STATUS

SR3_PARAMS: Parameter stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of PARAM_VALUE

Increment

Range

Units

1

0 to 50

hertz

SR3_ADSB: ADSB stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink ADSB stream rate

Increment

Range

Units

1

0 to 50

hertz

SR4_ Parameters

SR4_RAW_SENS: Raw sensor stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of RAW_IMU, SCALED_IMU2, SCALED_IMU3, SCALED_PRESSURE, SCALED_PRESSURE2, SCALED_PRESSURE3 and AIRSPEED

Increment

Range

Units

1

0 to 50

hertz

SR4_EXT_STAT: Extended status stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SYS_STATUS, POWER_STATUS, MCU_STATUS, MEMINFO, CURRENT_WAYPOINT, GPS_RAW_INT, GPS_RTK (if available), GPS2_RAW_INT (if available), GPS2_RTK (if available), NAV_CONTROLLER_OUTPUT, FENCE_STATUS, and GLOBAL_TARGET_POS_INT

Increment

Range

Units

1

0 to 50

hertz

SR4_RC_CHAN: RC Channel stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SERVO_OUTPUT_RAW and RC_CHANNELS

Increment

Range

Units

1

0 to 50

hertz

SR4_RAW_CTRL: Unused

Note: This parameter is for advanced users
Note: Reboot required after change

Unused

Increment

Range

Units

1

0 to 50

hertz

SR4_POSITION: Position stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of GLOBAL_POSITION_INT and LOCAL_POSITION_NED

Increment

Range

Units

1

0 to 50

hertz

SR4_EXTRA1: Extra data type 1 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of ATTITUDE, SIMSTATE (SIM only), AHRS2 and PID_TUNING

Increment

Range

1

0 to 50

SR4_EXTRA2: Extra data type 2 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of VFR_HUD

Increment

Range

Units

1

0 to 50

hertz

SR4_EXTRA3: Extra data type 3 stream rate

MAVLink Stream rate of AHRS, SYSTEM_TIME, WIND, RANGEFINDER, DISTANCE_SENSOR, TERRAIN_REQUEST, TERRAIN_REPORT, BATTERY_STATUS, GIMBAL_DEVICE_ATTITUDE_STATUS, OPTICAL_FLOW, MAG_CAL_REPORT, MAG_CAL_PROGRESS, EKF_STATUS_REPORT, VIBRATION, RPM, ESC TELEMETRY,GENERATOR_STATUS, and WINCH_STATUS

SR4_PARAMS: Parameter stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of PARAM_VALUE

Increment

Range

Units

1

0 to 50

hertz

SR4_ADSB: ADSB stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink ADSB stream rate

Increment

Range

Units

1

0 to 50

hertz

SR5_ Parameters

SR5_RAW_SENS: Raw sensor stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of RAW_IMU, SCALED_IMU2, SCALED_IMU3, SCALED_PRESSURE, SCALED_PRESSURE2, SCALED_PRESSURE3 and AIRSPEED

Increment

Range

Units

1

0 to 50

hertz

SR5_EXT_STAT: Extended status stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SYS_STATUS, POWER_STATUS, MCU_STATUS, MEMINFO, CURRENT_WAYPOINT, GPS_RAW_INT, GPS_RTK (if available), GPS2_RAW_INT (if available), GPS2_RTK (if available), NAV_CONTROLLER_OUTPUT, FENCE_STATUS, and GLOBAL_TARGET_POS_INT

Increment

Range

Units

1

0 to 50

hertz

SR5_RC_CHAN: RC Channel stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SERVO_OUTPUT_RAW and RC_CHANNELS

Increment

Range

Units

1

0 to 50

hertz

SR5_RAW_CTRL: Unused

Note: This parameter is for advanced users
Note: Reboot required after change

Unused

Increment

Range

Units

1

0 to 50

hertz

SR5_POSITION: Position stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of GLOBAL_POSITION_INT and LOCAL_POSITION_NED

Increment

Range

Units

1

0 to 50

hertz

SR5_EXTRA1: Extra data type 1 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of ATTITUDE, SIMSTATE (SIM only), AHRS2 and PID_TUNING

Increment

Range

1

0 to 50

SR5_EXTRA2: Extra data type 2 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of VFR_HUD

Increment

Range

Units

1

0 to 50

hertz

SR5_EXTRA3: Extra data type 3 stream rate

MAVLink Stream rate of AHRS, SYSTEM_TIME, WIND, RANGEFINDER, DISTANCE_SENSOR, TERRAIN_REQUEST, TERRAIN_REPORT, BATTERY_STATUS, GIMBAL_DEVICE_ATTITUDE_STATUS, OPTICAL_FLOW, MAG_CAL_REPORT, MAG_CAL_PROGRESS, EKF_STATUS_REPORT, VIBRATION, RPM, ESC TELEMETRY,GENERATOR_STATUS, and WINCH_STATUS

SR5_PARAMS: Parameter stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of PARAM_VALUE

Increment

Range

Units

1

0 to 50

hertz

SR5_ADSB: ADSB stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink ADSB stream rate

Increment

Range

Units

1

0 to 50

hertz

SR6_ Parameters

SR6_RAW_SENS: Raw sensor stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of RAW_IMU, SCALED_IMU2, SCALED_IMU3, SCALED_PRESSURE, SCALED_PRESSURE2, SCALED_PRESSURE3 and AIRSPEED

Increment

Range

Units

1

0 to 50

hertz

SR6_EXT_STAT: Extended status stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SYS_STATUS, POWER_STATUS, MCU_STATUS, MEMINFO, CURRENT_WAYPOINT, GPS_RAW_INT, GPS_RTK (if available), GPS2_RAW_INT (if available), GPS2_RTK (if available), NAV_CONTROLLER_OUTPUT, FENCE_STATUS, and GLOBAL_TARGET_POS_INT

Increment

Range

Units

1

0 to 50

hertz

SR6_RC_CHAN: RC Channel stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of SERVO_OUTPUT_RAW and RC_CHANNELS

Increment

Range

Units

1

0 to 50

hertz

SR6_RAW_CTRL: Unused

Note: This parameter is for advanced users
Note: Reboot required after change

Unused

Increment

Range

Units

1

0 to 50

hertz

SR6_POSITION: Position stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of GLOBAL_POSITION_INT and LOCAL_POSITION_NED

Increment

Range

Units

1

0 to 50

hertz

SR6_EXTRA1: Extra data type 1 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of ATTITUDE, SIMSTATE (SIM only), AHRS2 and PID_TUNING

Increment

Range

1

0 to 50

SR6_EXTRA2: Extra data type 2 stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of VFR_HUD

Increment

Range

Units

1

0 to 50

hertz

SR6_EXTRA3: Extra data type 3 stream rate

MAVLink Stream rate of AHRS, SYSTEM_TIME, WIND, RANGEFINDER, DISTANCE_SENSOR, TERRAIN_REQUEST, TERRAIN_REPORT, BATTERY_STATUS, GIMBAL_DEVICE_ATTITUDE_STATUS, OPTICAL_FLOW, MAG_CAL_REPORT, MAG_CAL_PROGRESS, EKF_STATUS_REPORT, VIBRATION, RPM, ESC TELEMETRY,GENERATOR_STATUS, and WINCH_STATUS

SR6_PARAMS: Parameter stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink Stream rate of PARAM_VALUE

Increment

Range

Units

1

0 to 50

hertz

SR6_ADSB: ADSB stream rate

Note: This parameter is for advanced users
Note: Reboot required after change

MAVLink ADSB stream rate

Increment

Range

Units

1

0 to 50

hertz

SRTL_ Parameters

SRTL_ACCURACY: SmartRTL accuracy

Note: This parameter is for advanced users

SmartRTL accuracy. The minimum distance between points.

Range

Units

0 to 10

meters

SRTL_POINTS: SmartRTL maximum number of points on path

Note: This parameter is for advanced users
Note: Reboot required after change

SmartRTL maximum number of points on path. Set to 0 to disable SmartRTL. 100 points consumes about 3k of memory.

Range

0 to 500

SRTL_OPTIONS: SmartRTL options

Bitmask of SmartRTL options.

Bitmask

Bit

Meaning

2

Ignore pilot yaw

STAT Parameters

STAT_BOOTCNT: Boot Count

Number of times board has been booted

ReadOnly

True

STAT_FLTTIME: Total FlightTime

Total FlightTime (seconds)

ReadOnly

Units

True

seconds

STAT_RUNTIME: Total RunTime

Total time autopilot has run

ReadOnly

Units

True

seconds

STAT_RESET: Statistics Reset Time

Seconds since January 1st 2016 (Unix epoch+1451606400) since statistics reset (set to 0 to reset statistics, other set values will be ignored)

ReadOnly

Units

True

seconds

TCAL Parameters

TCAL_ENABLED: Temperature calibration enable

Note: This parameter is for advanced users

Enable temperature calibration. Set to 0 to disable. Set to 1 to use learned values. Set to 2 to learn new values and use the values

Values

Value

Meaning

0

Disabled

1

Enabled

2

EnableAndLearn

TCAL_TEMP_MIN: Temperature calibration min learned temperature

Note: This parameter is for advanced users

Minimum learned temperature. This is automatically set by the learning process

ReadOnly

Units

Volatile

True

degrees Celsius

True

TCAL_TEMP_MAX: Temperature calibration max learned temperature

Note: This parameter is for advanced users

Maximum learned temperature. This is automatically set by the learning process

ReadOnly

Units

Volatile

True

degrees Celsius

True

TCAL_BARO_EXP: Temperature Calibration barometer exponent

Note: This parameter is for advanced users

Learned exponent for barometer temperature correction

ReadOnly

Volatile

True

True

TEMP Parameters

TEMP_LOG: Logging

Enables temperature sensor logging

Values

Value

Meaning

0

Disabled

1

Log all instances

2

Log only instances with sensor source set to None

TEMP1_ Parameters

TEMP1_TYPE: Temperature Sensor Type

Note: Reboot required after change

Enables temperature sensors

Values

Value

Meaning

0

Disabled

1

TSYS01

2

MCP9600

3

MAX31865

4

TSYS03

5

Analog

6

DroneCAN

7

MLX90614

TEMP1_BUS: Temperature sensor bus

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor bus number, typically used to select from multiple I2C buses

Range

0 to 3

TEMP1_ADDR: Temperature sensor address

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor address, typically used for I2C address

Range

0 to 127

TEMP1_SRC: Sensor Source

Sensor Source is used to designate which device's temperature report will be replaced by this temperature sensor's data. If 0 (None) then the data is only available via log. In the future a new Motor temperature report will be created for returning data directly.

Values

Value

Meaning

0

None

1

ESC

2

Motor

3

Battery Index

4

Battery ID/SerialNumber

5

CAN based Pitot tube

6

DroneCAN-out on AP_Periph

TEMP1_SRC_ID: Sensor Source Identification

Sensor Source Identification is used to replace a specific instance of a system component's temperature report with the temp sensor's. Examples: TEMP_SRC = 1 (ESC), TEMP_SRC_ID = 1 will set the temp of ESC1. TEMP_SRC = 3 (BatteryIndex),TEMP_SRC_ID = 2 will set the temp of BATT2. TEMP_SRC = 4 (BatteryId/SerialNum),TEMP_SRC_ID=42 will set the temp of all batteries that have param BATTn_SERIAL = 42.

TEMP1_PIN: Temperature sensor analog voltage sensing pin

Sets the analog input pin that should be used for temprature monitoring. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

TEMP1_A0: Temperature sensor analog 0th polynomial coefficient

a0 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP1_A1: Temperature sensor analog 1st polynomial coefficient

a1 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP1_A2: Temperature sensor analog 2nd polynomial coefficient

a2 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP1_A3: Temperature sensor analog 3rd polynomial coefficient

a3 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP1_A4: Temperature sensor analog 4th polynomial coefficient

a4 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP1_A5: Temperature sensor analog 5th polynomial coefficient

a5 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP2_ Parameters

TEMP2_TYPE: Temperature Sensor Type

Note: Reboot required after change

Enables temperature sensors

Values

Value

Meaning

0

Disabled

1

TSYS01

2

MCP9600

3

MAX31865

4

TSYS03

5

Analog

6

DroneCAN

7

MLX90614

TEMP2_BUS: Temperature sensor bus

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor bus number, typically used to select from multiple I2C buses

Range

0 to 3

TEMP2_ADDR: Temperature sensor address

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor address, typically used for I2C address

Range

0 to 127

TEMP2_SRC: Sensor Source

Sensor Source is used to designate which device's temperature report will be replaced by this temperature sensor's data. If 0 (None) then the data is only available via log. In the future a new Motor temperature report will be created for returning data directly.

Values

Value

Meaning

0

None

1

ESC

2

Motor

3

Battery Index

4

Battery ID/SerialNumber

5

CAN based Pitot tube

6

DroneCAN-out on AP_Periph

TEMP2_SRC_ID: Sensor Source Identification

Sensor Source Identification is used to replace a specific instance of a system component's temperature report with the temp sensor's. Examples: TEMP_SRC = 1 (ESC), TEMP_SRC_ID = 1 will set the temp of ESC1. TEMP_SRC = 3 (BatteryIndex),TEMP_SRC_ID = 2 will set the temp of BATT2. TEMP_SRC = 4 (BatteryId/SerialNum),TEMP_SRC_ID=42 will set the temp of all batteries that have param BATTn_SERIAL = 42.

TEMP2_PIN: Temperature sensor analog voltage sensing pin

Sets the analog input pin that should be used for temprature monitoring. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

TEMP2_A0: Temperature sensor analog 0th polynomial coefficient

a0 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP2_A1: Temperature sensor analog 1st polynomial coefficient

a1 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP2_A2: Temperature sensor analog 2nd polynomial coefficient

a2 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP2_A3: Temperature sensor analog 3rd polynomial coefficient

a3 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP2_A4: Temperature sensor analog 4th polynomial coefficient

a4 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP2_A5: Temperature sensor analog 5th polynomial coefficient

a5 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP3_ Parameters

TEMP3_TYPE: Temperature Sensor Type

Note: Reboot required after change

Enables temperature sensors

Values

Value

Meaning

0

Disabled

1

TSYS01

2

MCP9600

3

MAX31865

4

TSYS03

5

Analog

6

DroneCAN

7

MLX90614

TEMP3_BUS: Temperature sensor bus

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor bus number, typically used to select from multiple I2C buses

Range

0 to 3

TEMP3_ADDR: Temperature sensor address

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor address, typically used for I2C address

Range

0 to 127

TEMP3_SRC: Sensor Source

Sensor Source is used to designate which device's temperature report will be replaced by this temperature sensor's data. If 0 (None) then the data is only available via log. In the future a new Motor temperature report will be created for returning data directly.

Values

Value

Meaning

0

None

1

ESC

2

Motor

3

Battery Index

4

Battery ID/SerialNumber

5

CAN based Pitot tube

6

DroneCAN-out on AP_Periph

TEMP3_SRC_ID: Sensor Source Identification

Sensor Source Identification is used to replace a specific instance of a system component's temperature report with the temp sensor's. Examples: TEMP_SRC = 1 (ESC), TEMP_SRC_ID = 1 will set the temp of ESC1. TEMP_SRC = 3 (BatteryIndex),TEMP_SRC_ID = 2 will set the temp of BATT2. TEMP_SRC = 4 (BatteryId/SerialNum),TEMP_SRC_ID=42 will set the temp of all batteries that have param BATTn_SERIAL = 42.

TEMP3_PIN: Temperature sensor analog voltage sensing pin

Sets the analog input pin that should be used for temprature monitoring. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

TEMP3_A0: Temperature sensor analog 0th polynomial coefficient

a0 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP3_A1: Temperature sensor analog 1st polynomial coefficient

a1 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP3_A2: Temperature sensor analog 2nd polynomial coefficient

a2 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP3_A3: Temperature sensor analog 3rd polynomial coefficient

a3 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP3_A4: Temperature sensor analog 4th polynomial coefficient

a4 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP3_A5: Temperature sensor analog 5th polynomial coefficient

a5 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP4_ Parameters

TEMP4_TYPE: Temperature Sensor Type

Note: Reboot required after change

Enables temperature sensors

Values

Value

Meaning

0

Disabled

1

TSYS01

2

MCP9600

3

MAX31865

4

TSYS03

5

Analog

6

DroneCAN

7

MLX90614

TEMP4_BUS: Temperature sensor bus

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor bus number, typically used to select from multiple I2C buses

Range

0 to 3

TEMP4_ADDR: Temperature sensor address

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor address, typically used for I2C address

Range

0 to 127

TEMP4_SRC: Sensor Source

Sensor Source is used to designate which device's temperature report will be replaced by this temperature sensor's data. If 0 (None) then the data is only available via log. In the future a new Motor temperature report will be created for returning data directly.

Values

Value

Meaning

0

None

1

ESC

2

Motor

3

Battery Index

4

Battery ID/SerialNumber

5

CAN based Pitot tube

6

DroneCAN-out on AP_Periph

TEMP4_SRC_ID: Sensor Source Identification

Sensor Source Identification is used to replace a specific instance of a system component's temperature report with the temp sensor's. Examples: TEMP_SRC = 1 (ESC), TEMP_SRC_ID = 1 will set the temp of ESC1. TEMP_SRC = 3 (BatteryIndex),TEMP_SRC_ID = 2 will set the temp of BATT2. TEMP_SRC = 4 (BatteryId/SerialNum),TEMP_SRC_ID=42 will set the temp of all batteries that have param BATTn_SERIAL = 42.

TEMP4_PIN: Temperature sensor analog voltage sensing pin

Sets the analog input pin that should be used for temprature monitoring. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

TEMP4_A0: Temperature sensor analog 0th polynomial coefficient

a0 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP4_A1: Temperature sensor analog 1st polynomial coefficient

a1 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP4_A2: Temperature sensor analog 2nd polynomial coefficient

a2 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP4_A3: Temperature sensor analog 3rd polynomial coefficient

a3 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP4_A4: Temperature sensor analog 4th polynomial coefficient

a4 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP4_A5: Temperature sensor analog 5th polynomial coefficient

a5 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP5_ Parameters

TEMP5_TYPE: Temperature Sensor Type

Note: Reboot required after change

Enables temperature sensors

Values

Value

Meaning

0

Disabled

1

TSYS01

2

MCP9600

3

MAX31865

4

TSYS03

5

Analog

6

DroneCAN

7

MLX90614

TEMP5_BUS: Temperature sensor bus

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor bus number, typically used to select from multiple I2C buses

Range

0 to 3

TEMP5_ADDR: Temperature sensor address

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor address, typically used for I2C address

Range

0 to 127

TEMP5_SRC: Sensor Source

Sensor Source is used to designate which device's temperature report will be replaced by this temperature sensor's data. If 0 (None) then the data is only available via log. In the future a new Motor temperature report will be created for returning data directly.

Values

Value

Meaning

0

None

1

ESC

2

Motor

3

Battery Index

4

Battery ID/SerialNumber

5

CAN based Pitot tube

6

DroneCAN-out on AP_Periph

TEMP5_SRC_ID: Sensor Source Identification

Sensor Source Identification is used to replace a specific instance of a system component's temperature report with the temp sensor's. Examples: TEMP_SRC = 1 (ESC), TEMP_SRC_ID = 1 will set the temp of ESC1. TEMP_SRC = 3 (BatteryIndex),TEMP_SRC_ID = 2 will set the temp of BATT2. TEMP_SRC = 4 (BatteryId/SerialNum),TEMP_SRC_ID=42 will set the temp of all batteries that have param BATTn_SERIAL = 42.

TEMP5_PIN: Temperature sensor analog voltage sensing pin

Sets the analog input pin that should be used for temprature monitoring. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

TEMP5_A0: Temperature sensor analog 0th polynomial coefficient

a0 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP5_A1: Temperature sensor analog 1st polynomial coefficient

a1 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP5_A2: Temperature sensor analog 2nd polynomial coefficient

a2 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP5_A3: Temperature sensor analog 3rd polynomial coefficient

a3 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP5_A4: Temperature sensor analog 4th polynomial coefficient

a4 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP5_A5: Temperature sensor analog 5th polynomial coefficient

a5 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP6_ Parameters

TEMP6_TYPE: Temperature Sensor Type

Note: Reboot required after change

Enables temperature sensors

Values

Value

Meaning

0

Disabled

1

TSYS01

2

MCP9600

3

MAX31865

4

TSYS03

5

Analog

6

DroneCAN

7

MLX90614

TEMP6_BUS: Temperature sensor bus

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor bus number, typically used to select from multiple I2C buses

Range

0 to 3

TEMP6_ADDR: Temperature sensor address

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor address, typically used for I2C address

Range

0 to 127

TEMP6_SRC: Sensor Source

Sensor Source is used to designate which device's temperature report will be replaced by this temperature sensor's data. If 0 (None) then the data is only available via log. In the future a new Motor temperature report will be created for returning data directly.

Values

Value

Meaning

0

None

1

ESC

2

Motor

3

Battery Index

4

Battery ID/SerialNumber

5

CAN based Pitot tube

6

DroneCAN-out on AP_Periph

TEMP6_SRC_ID: Sensor Source Identification

Sensor Source Identification is used to replace a specific instance of a system component's temperature report with the temp sensor's. Examples: TEMP_SRC = 1 (ESC), TEMP_SRC_ID = 1 will set the temp of ESC1. TEMP_SRC = 3 (BatteryIndex),TEMP_SRC_ID = 2 will set the temp of BATT2. TEMP_SRC = 4 (BatteryId/SerialNum),TEMP_SRC_ID=42 will set the temp of all batteries that have param BATTn_SERIAL = 42.

TEMP6_PIN: Temperature sensor analog voltage sensing pin

Sets the analog input pin that should be used for temprature monitoring. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

TEMP6_A0: Temperature sensor analog 0th polynomial coefficient

a0 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP6_A1: Temperature sensor analog 1st polynomial coefficient

a1 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP6_A2: Temperature sensor analog 2nd polynomial coefficient

a2 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP6_A3: Temperature sensor analog 3rd polynomial coefficient

a3 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP6_A4: Temperature sensor analog 4th polynomial coefficient

a4 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP6_A5: Temperature sensor analog 5th polynomial coefficient

a5 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP7_ Parameters

TEMP7_TYPE: Temperature Sensor Type

Note: Reboot required after change

Enables temperature sensors

Values

Value

Meaning

0

Disabled

1

TSYS01

2

MCP9600

3

MAX31865

4

TSYS03

5

Analog

6

DroneCAN

7

MLX90614

TEMP7_BUS: Temperature sensor bus

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor bus number, typically used to select from multiple I2C buses

Range

0 to 3

TEMP7_ADDR: Temperature sensor address

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor address, typically used for I2C address

Range

0 to 127

TEMP7_SRC: Sensor Source

Sensor Source is used to designate which device's temperature report will be replaced by this temperature sensor's data. If 0 (None) then the data is only available via log. In the future a new Motor temperature report will be created for returning data directly.

Values

Value

Meaning

0

None

1

ESC

2

Motor

3

Battery Index

4

Battery ID/SerialNumber

5

CAN based Pitot tube

6

DroneCAN-out on AP_Periph

TEMP7_SRC_ID: Sensor Source Identification

Sensor Source Identification is used to replace a specific instance of a system component's temperature report with the temp sensor's. Examples: TEMP_SRC = 1 (ESC), TEMP_SRC_ID = 1 will set the temp of ESC1. TEMP_SRC = 3 (BatteryIndex),TEMP_SRC_ID = 2 will set the temp of BATT2. TEMP_SRC = 4 (BatteryId/SerialNum),TEMP_SRC_ID=42 will set the temp of all batteries that have param BATTn_SERIAL = 42.

TEMP7_PIN: Temperature sensor analog voltage sensing pin

Sets the analog input pin that should be used for temprature monitoring. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

TEMP7_A0: Temperature sensor analog 0th polynomial coefficient

a0 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP7_A1: Temperature sensor analog 1st polynomial coefficient

a1 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP7_A2: Temperature sensor analog 2nd polynomial coefficient

a2 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP7_A3: Temperature sensor analog 3rd polynomial coefficient

a3 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP7_A4: Temperature sensor analog 4th polynomial coefficient

a4 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP7_A5: Temperature sensor analog 5th polynomial coefficient

a5 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP8_ Parameters

TEMP8_TYPE: Temperature Sensor Type

Note: Reboot required after change

Enables temperature sensors

Values

Value

Meaning

0

Disabled

1

TSYS01

2

MCP9600

3

MAX31865

4

TSYS03

5

Analog

6

DroneCAN

7

MLX90614

TEMP8_BUS: Temperature sensor bus

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor bus number, typically used to select from multiple I2C buses

Range

0 to 3

TEMP8_ADDR: Temperature sensor address

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor address, typically used for I2C address

Range

0 to 127

TEMP8_SRC: Sensor Source

Sensor Source is used to designate which device's temperature report will be replaced by this temperature sensor's data. If 0 (None) then the data is only available via log. In the future a new Motor temperature report will be created for returning data directly.

Values

Value

Meaning

0

None

1

ESC

2

Motor

3

Battery Index

4

Battery ID/SerialNumber

5

CAN based Pitot tube

6

DroneCAN-out on AP_Periph

TEMP8_SRC_ID: Sensor Source Identification

Sensor Source Identification is used to replace a specific instance of a system component's temperature report with the temp sensor's. Examples: TEMP_SRC = 1 (ESC), TEMP_SRC_ID = 1 will set the temp of ESC1. TEMP_SRC = 3 (BatteryIndex),TEMP_SRC_ID = 2 will set the temp of BATT2. TEMP_SRC = 4 (BatteryId/SerialNum),TEMP_SRC_ID=42 will set the temp of all batteries that have param BATTn_SERIAL = 42.

TEMP8_PIN: Temperature sensor analog voltage sensing pin

Sets the analog input pin that should be used for temprature monitoring. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

TEMP8_A0: Temperature sensor analog 0th polynomial coefficient

a0 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP8_A1: Temperature sensor analog 1st polynomial coefficient

a1 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP8_A2: Temperature sensor analog 2nd polynomial coefficient

a2 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP8_A3: Temperature sensor analog 3rd polynomial coefficient

a3 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP8_A4: Temperature sensor analog 4th polynomial coefficient

a4 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP8_A5: Temperature sensor analog 5th polynomial coefficient

a5 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP9_ Parameters

TEMP9_TYPE: Temperature Sensor Type

Note: Reboot required after change

Enables temperature sensors

Values

Value

Meaning

0

Disabled

1

TSYS01

2

MCP9600

3

MAX31865

4

TSYS03

5

Analog

6

DroneCAN

7

MLX90614

TEMP9_BUS: Temperature sensor bus

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor bus number, typically used to select from multiple I2C buses

Range

0 to 3

TEMP9_ADDR: Temperature sensor address

Note: This parameter is for advanced users
Note: Reboot required after change

Temperature sensor address, typically used for I2C address

Range

0 to 127

TEMP9_SRC: Sensor Source

Sensor Source is used to designate which device's temperature report will be replaced by this temperature sensor's data. If 0 (None) then the data is only available via log. In the future a new Motor temperature report will be created for returning data directly.

Values

Value

Meaning

0

None

1

ESC

2

Motor

3

Battery Index

4

Battery ID/SerialNumber

5

CAN based Pitot tube

6

DroneCAN-out on AP_Periph

TEMP9_SRC_ID: Sensor Source Identification

Sensor Source Identification is used to replace a specific instance of a system component's temperature report with the temp sensor's. Examples: TEMP_SRC = 1 (ESC), TEMP_SRC_ID = 1 will set the temp of ESC1. TEMP_SRC = 3 (BatteryIndex),TEMP_SRC_ID = 2 will set the temp of BATT2. TEMP_SRC = 4 (BatteryId/SerialNum),TEMP_SRC_ID=42 will set the temp of all batteries that have param BATTn_SERIAL = 42.

TEMP9_PIN: Temperature sensor analog voltage sensing pin

Sets the analog input pin that should be used for temprature monitoring. Values for some autopilots are given as examples. Search wiki for "Analog pins".

Values

Value

Meaning

-1

Disabled

2

Pixhawk/Pixracer/Navio2/Pixhawk2_PM1

5

Navigator

13

Pixhawk2_PM2/CubeOrange_PM2

14

CubeOrange

16

Durandal

100

PX4-v1

TEMP9_A0: Temperature sensor analog 0th polynomial coefficient

a0 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP9_A1: Temperature sensor analog 1st polynomial coefficient

a1 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP9_A2: Temperature sensor analog 2nd polynomial coefficient

a2 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP9_A3: Temperature sensor analog 3rd polynomial coefficient

a3 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP9_A4: Temperature sensor analog 4th polynomial coefficient

a4 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TEMP9_A5: Temperature sensor analog 5th polynomial coefficient

a5 in polynomial of form temperature in deg = a0 + a1*voltage + a2*voltage^2 + a3*voltage^3 + a4*voltage^4 + a5*voltage^5

TERRAIN_ Parameters

TERRAIN_ENABLE: Terrain data enable

Note: This parameter is for advanced users

enable terrain data. This enables the vehicle storing a database of terrain data on the SD card. The terrain data is requested from the ground station as needed, and stored for later use on the SD card. To be useful the ground station must support TERRAIN_REQUEST messages and have access to a terrain database, such as the SRTM database.

Values

Value

Meaning

0

Disable

1

Enable

TERRAIN_SPACING: Terrain grid spacing

Note: This parameter is for advanced users

Distance between terrain grid points in meters. This controls the horizontal resolution of the terrain data that is stored on te SD card and requested from the ground station. If your GCS is using the ArduPilot SRTM database like Mission Planner or MAVProxy, then a resolution of 100 meters is appropriate. Grid spacings lower than 100 meters waste SD card space if the GCS cannot provide that resolution. The grid spacing also controls how much data is kept in memory during flight. A larger grid spacing will allow for a larger amount of data in memory. A grid spacing of 100 meters results in the vehicle keeping 12 grid squares in memory with each grid square having a size of 2.7 kilometers by 3.2 kilometers. Any additional grid squares are stored on the SD once they are fetched from the GCS and will be loaded as needed.

Increment

Units

1

meters

TERRAIN_OPTIONS: Terrain options

Note: This parameter is for advanced users

Options to change behaviour of terrain system

Bitmask

Bit

Meaning

0

Disable Download

TERRAIN_MARGIN: Acceptance margin

Note: This parameter is for advanced users

Margin in centi-meters to accept terrain data from the GCS. This can be used to allow older terrain data generated with less accurate latitude/longitude scaling to be used

Range

Units

0.05 to 50000

meters

TERRAIN_OFS_MAX: Terrain reference offset maximum

Note: This parameter is for advanced users

The maximum adjustment of terrain altitude based on the assumption that the vehicle is on the ground when it is armed. When the vehicle is armed the location of the vehicle is recorded, and when terrain data is available for that location a height adjustment for terrain data is calculated that aligns the terrain height at that location with the altitude recorded at arming. This height adjustment is applied to all terrain data. This parameter clamps the amount of adjustment. A value of zero disables the use of terrain height adjustment.

Range

Units

0 to 50

meters

TERRAIN_CACHE_SZ: Terrain cache size

Note: This parameter is for advanced users

The number of 32x28 cache blocks to keep in memory. Each block uses about 1800 bytes of memory

Range

0 to 128

TMODE Parameters

TMODE_ENABLE: tmode enable

Note: This parameter is for advanced users

tmode (or "toy" mode) gives a simplified user interface designed for mass market drones. Version1 is for the SkyViper V2450GPS. Version2 is for the F412 based boards

Values

Value

Meaning

0

Disabled

1

EnableVersion1

2

EnableVersion2

TMODE_MODE1: Tmode first mode

This is the initial mode when the vehicle is first turned on. This mode is assumed to not require GPS

Values

Value

Meaning

0

Stabilize

1

Acro

2

AltHold

3

Auto

4

Guided

5

Loiter

6

RTL

7

Circle

9

Land

11

Drift

13

Sport

14

Flip

15

AutoTune

16

PosHold

17

Brake

18

Throw

19

Avoid_ADSB

20

Guided_NoGPS

21

FlowHold

TMODE_MODE2: Tmode second mode

This is the secondary mode. This mode is assumed to require GPS

Values

Value

Meaning

0

Stabilize

1

Acro

2

AltHold

3

Auto

4

Guided

5

Loiter

6

RTL

7

Circle

9

Land

11

Drift

13

Sport

14

Flip

15

AutoTune

16

PosHold

17

Brake

18

Throw

19

Avoid_ADSB

20

Guided_NoGPS

21

FlowHold

TMODE_ACTION1: Tmode action 1

This is the action taken when the left action button is pressed

Values

Value

Meaning

0

None

1

TakePhoto

2

ToggleVideo

3

ModeAcro

4

ModeAltHold

5

ModeAuto

6

ModeLoiter

7

ModeRTL

8

ModeCircle

9

ModeLand

10

ModeDrift

11

ModeSport

12

ModeAutoTune

13

ModePosHold

14

ModeBrake

15

ModeThrow

16

Flip

17

ModeStabilize

18

Disarm

19

ToggleMode

20

Arm-Land-RTL

21

ToggleSimpleMode

22

ToggleSuperSimpleMode

23

MotorLoadTest

24

ModeFlowHold

TMODE_ACTION2: Tmode action 2

This is the action taken when the right action button is pressed

Values

Value

Meaning

0

None

1

TakePhoto

2

ToggleVideo

3

ModeAcro

4

ModeAltHold

5

ModeAuto

6

ModeLoiter

7

ModeRTL

8

ModeCircle

9

ModeLand

10

ModeDrift

11

ModeSport

12

ModeAutoTune

13

ModePosHold

14

ModeBrake

15

ModeThrow

16

Flip

17

ModeStabilize

18

Disarm

19

ToggleMode

20

Arm-Land-RTL

21

ToggleSimpleMode

22

ToggleSuperSimpleMode

23

MotorLoadTest

24

ModeFlowHold

TMODE_ACTION3: Tmode action 3

This is the action taken when the power button is pressed

Values

Value

Meaning

0

None

1

TakePhoto

2

ToggleVideo

3

ModeAcro

4

ModeAltHold

5

ModeAuto

6

ModeLoiter

7

ModeRTL

8

ModeCircle

9

ModeLand

10

ModeDrift

11

ModeSport

12

ModeAutoTune

13

ModePosHold

14

ModeBrake

15

ModeThrow

16

Flip

17

ModeStabilize

18

Disarm

19

ToggleMode

20

Arm-Land-RTL

21

ToggleSimpleMode

22

ToggleSuperSimpleMode

23

MotorLoadTest

24

ModeFlowHold

TMODE_ACTION4: Tmode action 4

This is the action taken when the left action button is pressed while the left (Mode) button is held down

Values

Value

Meaning

0

None

1

TakePhoto

2

ToggleVideo

3

ModeAcro

4

ModeAltHold

5

ModeAuto

6

ModeLoiter

7

ModeRTL

8

ModeCircle

9

ModeLand

10

ModeDrift

11

ModeSport

12

ModeAutoTune

13

ModePosHold

14

ModeBrake

15

ModeThrow

16

Flip

17

ModeStabilize

18

Disarm

19

ToggleMode

20

Arm-Land-RTL

21

ToggleSimpleMode

22

ToggleSuperSimpleMode

23

MotorLoadTest

24

ModeFlowHold

TMODE_ACTION5: Tmode action 5

This is the action taken when the right action is pressed while the left (Mode) button is held down

Values

Value

Meaning

0

None

1

TakePhoto

2

ToggleVideo

3

ModeAcro

4

ModeAltHold

5

ModeAuto

6

ModeLoiter

7

ModeRTL

8

ModeCircle

9

ModeLand

10

ModeDrift

11

ModeSport

12

ModeAutoTune

13

ModePosHold

14

ModeBrake

15

ModeThrow

16

Flip

17

ModeStabilize

18

Disarm

19

ToggleMode

20

Arm-Land-RTL

21

ToggleSimpleMode

22

ToggleSuperSimpleMode

23

MotorLoadTest

24

ModeFlowHold

TMODE_ACTION6: Tmode action 6

This is the action taken when the power button is pressed while the left (Mode) button is held down

Values

Value

Meaning

0

None

1

TakePhoto

2

ToggleVideo

3

ModeAcro

4

ModeAltHold

5

ModeAuto

6

ModeLoiter

7

ModeRTL

8

ModeCircle

9

ModeLand

10

ModeDrift

11

ModeSport

12

ModeAutoTune

13

ModePosHold

14

ModeBrake

15

ModeThrow

16

Flip

17

ModeStabilize

18

Disarm

19

ToggleMode

20

Arm-Land-RTL

21

ToggleSimpleMode

22

ToggleSuperSimpleMode

23

MotorLoadTest

24

ModeFlowHold

TMODE_LEFT: Tmode left action

This is the action taken when the left (Mode) button is pressed

Values

Value

Meaning

0

None

1

TakePhoto

2

ToggleVideo

3

ModeAcro

4

ModeAltHold

5

ModeAuto

6

ModeLoiter

7

ModeRTL

8

ModeCircle

9

ModeLand

10

ModeDrift

11

ModeSport

12

ModeAutoTune

13

ModePosHold

14

ModeBrake

15

ModeThrow

16

Flip

17

ModeStabilize

18

Disarm

19

ToggleMode

20

Arm-Land-RTL

21

ToggleSimpleMode

22

ToggleSuperSimpleMode

23

MotorLoadTest

24

ModeFlowHold

TMODE_LEFT_LONG: Tmode left long action

This is the action taken when the left (Mode) button is long-pressed

Values

Value

Meaning

0

None

1

TakePhoto

2

ToggleVideo

3

ModeAcro

4

ModeAltHold

5

ModeAuto

6

ModeLoiter

7

ModeRTL

8

ModeCircle

9

ModeLand

10

ModeDrift

11

ModeSport

12

ModeAutoTune

13

ModePosHold

14

ModeBrake

15

ModeThrow

16

Flip

17

ModeStabilize

18

Disarm

19

ToggleMode

20

Arm-Land-RTL

21

ToggleSimpleMode

22

ToggleSuperSimpleMode

23

MotorLoadTest

24

ModeFlowHold

TMODE_TRIM_AUTO: Stick auto trim limit

This is the amount of automatic stick trim that can be applied when disarmed with sticks not moving. It is a PWM limit value away from 1500

Range

0 to 100

TMODE_RIGHT: Tmode right action

This is the action taken when the right (Return) button is pressed

Values

Value

Meaning

0

None

1

TakePhoto

2

ToggleVideo

3

ModeAcro

4

ModeAltHold

5

ModeAuto

6

ModeLoiter

7

ModeRTL

8

ModeCircle

9

ModeLand

10

ModeDrift

11

ModeSport

12

ModeAutoTune

13

ModePosHold

14

ModeBrake

15

ModeThrow

16

Flip

17

ModeStabilize

18

Disarm

19

ToggleMode

20

Arm-Land-RTL

21

ToggleSimpleMode

22

ToggleSuperSimpleMode

23

MotorLoadTest

TMODE_FLAGS: Tmode flags

Bitmask of flags to change the behaviour of tmode. DisarmOnLowThrottle means to disarm if throttle is held down for 1 second when landed. ArmOnHighThrottle means to arm if throttle is above 80% for 1 second. UpgradeToLoiter means to allow takeoff in LOITER mode by switching to ALT_HOLD, then auto-upgrading to LOITER once GPS is available. RTLStickCancel means that on large stick inputs in RTL mode that LOITER mode is engaged

Bitmask

Bit

Meaning

0

DisarmOnLowThrottle

1

ArmOnHighThrottle

2

UpgradeToLoiter

3

RTLStickCancel

TMODE_VMIN: Min voltage for output limiting

Note: This parameter is for advanced users

This is the battery voltage below which no output limiting is done

Increment

Range

0.01

0 to 5

TMODE_VMAX: Max voltage for output limiting

Note: This parameter is for advanced users

This is the battery voltage above which thrust min is used

Increment

Range

0.01

0 to 5

TMODE_TMIN: Min thrust multiplier

Note: This parameter is for advanced users

This sets the thrust multiplier when voltage is high

Increment

Range

0.01

0 to 1

TMODE_TMAX: Max thrust multiplier

Note: This parameter is for advanced users

This sets the thrust multiplier when voltage is low

Increment

Range

0.01

0 to 1

TMODE_LOAD_MUL: Load test multiplier

Note: This parameter is for advanced users

This scales the load test output, as a value between 0 and 1

Increment

Range

0.01

0 to 1

TMODE_LOAD_FILT: Load test filter

Note: This parameter is for advanced users

This filters the load test output. A value of 1 means no filter. 2 means values are repeated once. 3 means values are repeated 3 times, etc

Range

0 to 100

TMODE_LOAD_TYPE: Load test type

Note: This parameter is for advanced users

This sets the type of load test

Values

Value

Meaning

0

ConstantThrust

1

LogReplay1

2

LogReplay2

VISO Parameters

VISO_TYPE: Visual odometry camera connection type

Note: This parameter is for advanced users
Note: Reboot required after change

Visual odometry camera connection type

Values

Value

Meaning

0

None

1

MAVLink

2

IntelT265

3

VOXL(ModalAI)

VISO_POS_X: Visual odometry camera X position offset

Note: This parameter is for advanced users

X position of the camera in body frame. Positive X is forward of the origin.

Increment

Range

Units

0.01

-5 to 5

meters

VISO_POS_Y: Visual odometry camera Y position offset

Note: This parameter is for advanced users

Y position of the camera in body frame. Positive Y is to the right of the origin.

Increment

Range

Units

0.01

-5 to 5

meters

VISO_POS_Z: Visual odometry camera Z position offset

Note: This parameter is for advanced users

Z position of the camera in body frame. Positive Z is down from the origin.

Increment

Range

Units

0.01

-5 to 5

meters

VISO_ORIENT: Visual odometery camera orientation

Note: This parameter is for advanced users

Visual odometery camera orientation

Values

Value

Meaning

0

Forward

2

Right

4

Back

6

Left

24

Up

25

Down

VISO_SCALE: Visual odometry scaling factor

Note: This parameter is for advanced users

Visual odometry scaling factor applied to position estimates from sensor

VISO_DELAY_MS: Visual odometry sensor delay

Note: This parameter is for advanced users

Visual odometry sensor delay relative to inertial measurements

Range

Units

0 to 250

milliseconds

VISO_VEL_M_NSE: Visual odometry velocity measurement noise

Note: This parameter is for advanced users

Visual odometry velocity measurement noise in m/s

Range

Units

0.05 to 5.0

meters per second

VISO_POS_M_NSE: Visual odometry position measurement noise

Note: This parameter is for advanced users

Visual odometry position measurement noise minimum (meters). This value will be used if the sensor provides a lower noise value (or no noise value)

Range

Units

0.1 to 10.0

meters

VISO_YAW_M_NSE: Visual odometry yaw measurement noise

Note: This parameter is for advanced users

Visual odometry yaw measurement noise minimum (radians), This value will be used if the sensor provides a lower noise value (or no noise value)

Range

Units

0.05 to 1.0

radians

VISO_QUAL_MIN: Visual odometry minimum quality

Note: This parameter is for advanced users

Visual odometry will only be sent to EKF if over this value. -1 to always send (even bad values), 0 to send if good or unknown

Range

Units

-1 to 100

percent

VTX_ Parameters

VTX_ENABLE: Is the Video Transmitter enabled or not

Toggles the Video Transmitter on and off

Values

Value

Meaning

0

Disable

1

Enable

VTX_POWER: Video Transmitter Power Level

Video Transmitter Power Level. Different VTXs support different power levels, the power level chosen will be rounded down to the nearest supported power level

Range

1 to 1000

VTX_CHANNEL: Video Transmitter Channel

Video Transmitter Channel

Range

0 to 7

VTX_BAND: Video Transmitter Band

Video Transmitter Band

Values

Value

Meaning

0

Band A

1

Band B

2

Band E

3

Airwave

4

RaceBand

5

Low RaceBand

6

1G3 Band A

7

1G3 Band B

8

Band X

9

3G3 Band A

10

3G3 Band B

VTX_FREQ: Video Transmitter Frequency

Video Transmitter Frequency. The frequency is derived from the setting of BAND and CHANNEL

Range

ReadOnly

1000 to 6000

True

VTX_OPTIONS: Video Transmitter Options

Note: This parameter is for advanced users

Video Transmitter Options. Pitmode puts the VTX in a low power state. Unlocked enables certain restricted frequencies and power levels. Do not enable the Unlocked option unless you have appropriate permissions in your jurisdiction to transmit at high power levels. One stop-bit may be required for VTXs that erroneously mimic iNav behaviour.

Bitmask

Bit

Meaning

0

Pitmode

1

Pitmode until armed

2

Pitmode when disarmed

3

Unlocked

4

Add leading zero byte to requests

5

Use 1 stop-bit in SmartAudio

6

Ignore CRC in SmartAudio

7

Ignore status updates in CRSF and blindly set VTX options

VTX_MAX_POWER: Video Transmitter Max Power Level

Video Transmitter Maximum Power Level. Different VTXs support different power levels, this prevents the power aux switch from requesting too high a power level. The switch supports 6 power levels and the selected power will be a subdivision between 0 and this setting.

Range

25 to 1000

WINCH Parameters

WINCH_TYPE: Winch Type

Winch Type

Values

Value

Meaning

0

None

1

PWM

2

Daiwa

WINCH_RATE_MAX: Winch deploy or retract rate maximum

Winch deploy or retract rate maximum. Set to maximum rate with no load.

Range

Units

0 to 10

meters per second

WINCH_POS_P: Winch control position error P gain

Winch control position error P gain

Range

0.01 to 10.0

WINCH_OPTIONS: Winch options

Winch options

Bitmask

0:Spin freely on startup, 1:Verbose output, 2:Retry if stuck (Daiwa only)

WVANE_ Parameters

WVANE_ENABLE: Enable

Enable weather vaning. When active, the aircraft will automatically yaw into wind when in a VTOL position controlled mode. Pilot yaw commands override the weathervaning action.

Values

Value

Meaning

-1

Only use during takeoffs or landing see weathervane takeoff and land override parameters

0

Disabled

1

Nose into wind

2

Nose or tail into wind

3

Side into wind

4

tail into wind

WVANE_GAIN: Weathervaning gain

This converts the target roll/pitch angle of the aircraft into the correcting (into wind) yaw rate. e.g. Gain = 2, roll = 30 deg, pitch = 0 deg, yaw rate = 60 deg/s.

Increment

Range

0.1

0.5 to 4

WVANE_ANG_MIN: Weathervaning min angle

The minimum target roll/pitch angle before active weathervaning will start. This provides a dead zone that is particularly useful for poorly trimmed quadplanes.

Increment

Range

Units

0.1

0 to 10

degrees

WVANE_HGT_MIN: Weathervaning min height

Above this height weathervaning is permitted. If a range finder is fitted or if terrain is enabled, this parameter sets height AGL. Otherwise, this parameter sets height above home. Set zero to ignore minimum height requirement to activate weathervaning.

Increment

Range

Units

1

0 to 50

meters

WVANE_SPD_MAX: Weathervaning max ground speed

Below this ground speed weathervaning is permitted. Set to 0 to ignore this condition when checking if vehicle should weathervane.

Increment

Range

Units

0.1

0 to 50

meters per second

WVANE_VELZ_MAX: Weathervaning max vertical speed

The maximum climb or descent speed that the vehicle will still attempt to weathervane. Set to 0 to ignore this condition to get the aircraft to weathervane at any climb/descent rate. This is particularly useful for aircraft with low disc loading that struggle with yaw control in decent.

Increment

Range

Units

0.1

0 to 5

meters per second

WVANE_TAKEOFF: Takeoff override

Override the weather vaning behaviour when in takeoffs

Values

Value

Meaning

-1

No override

0

Disabled

1

Nose into wind

2

Nose or tail into wind

3

Side into wind

4

tail into wind

WVANE_LAND: Landing override

Override the weather vaning behaviour when in landing

Values

Value

Meaning

-1

No override

0

Disabled

1

Nose into wind

2

Nose or tail into wind

3

Side into wind

4

tail into wind

WVANE_OPTIONS: Weathervaning options

Options impacting weathervaning behaviour

Bitmask

Bit

Meaning

0

Use pitch when nose or tail-in for faster weathervaning

ZIGZ_ Parameters

ZIGZ_AUTO_ENABLE: ZigZag auto enable/disable

Note: This parameter is for advanced users

Allows you to enable (1) or disable (0) ZigZag auto feature

Values

Value

Meaning

0

Disabled

1

Enabled

ZIGZ_SPRAYER: Auto sprayer in ZigZag

Note: This parameter is for advanced users

Enable the auto sprayer in ZigZag mode. SPRAY_ENABLE = 1 and SERVOx_FUNCTION = 22(SprayerPump) / 23(SprayerSpinner) also must be set. This makes the sprayer on while moving to destination A or B. The sprayer will stop if the vehicle reaches destination or the flight mode is changed from ZigZag to other.

Values

Value

Meaning

0

Disabled

1

Enabled

ZIGZ_WP_DELAY: The delay for zigzag waypoint

Note: This parameter is for advanced users

Waiting time after reached the destination

Range

Units

0 to 127

seconds

ZIGZ_SIDE_DIST: Sideways distance in ZigZag auto

Note: This parameter is for advanced users

The distance to move sideways in ZigZag mode

Range

Units

0.1 to 100

meters

ZIGZ_DIRECTION: Sideways direction in ZigZag auto

Note: This parameter is for advanced users

The direction to move sideways in ZigZag mode

Values

Value

Meaning

0

forward

1

right

2

backward

3

left

ZIGZ_LINE_NUM: Total number of lines

Note: This parameter is for advanced users

Total number of lines for ZigZag auto if 1 or more. -1: Infinity, 0: Just moving to sideways

Range

-1 to 32767